This garage door opener has been designed and tested
to offer safe service provided it is installed, operated,
maintained and tested in strict accordance with the
instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal
Words on the following pages, they will alert you to
the possibility of serious injury or death if you do not
comply with the warnings that accompany them. The
hazard may come from something mechanical or from
electric shock. Read the warnings carefully.
Mechanical
Electrical
When you see this Signal Word on the following pages, it
will alert you to the possibility of damage to your garage
door and/or the garage door opener if you do not comply
with the cautionary statements that accompany it. Read
them carefully.
Unattended Operation
The Timer-to-Close (TTC) feature, the MyQ® Smartphone
Control app, and MyQ® Garage Door and Gate Monitor are
examples of unattended close and are to be used ONLY
with sectional doors. Any device or feature that allows the
door to close without being in the line of sight of the door
is considered unattended close. The Timer-to-Close (TTC)
feature, the MyQ® Smartphone Control, and any other
MyQ® devices are to be used ONLY with sectional doors.
CONTACT INFORMATION
Leave this Users Guide with the homeowner.
The images throughout this manual are for reference and your product may look different.
2
WARNING
WARNING
WARNING
Important Safety Instructions
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
2. Install garage door opener ONLY on properly
balanced and lubricated garage door. An
improperly balanced door may NOT reverse when
required and could result in SEVERE INJURY or
DEATH.
3. ALL repairs to cables, spring assemblies and
other hardware MUST be made by a trained door
systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes
connected to garage door BEFORE installing
opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or
more above fl oor.
6. Mount the emergency release within reach, but at
least 6 feet (1.83 m) above the fl oor and avoiding
contact with vehicles to avoid accidental release.
7. NEVER connect garage door opener to power
source until instructed to do so.
8. NEVER wear watches, rings or loose clothing
while installing or servicing opener. They could
be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
NOTE: For complete installation instructions visit LiftMaster.com to print the entire owner’s manual.
10. Place entrapment warning label on wall next to
garage door control.
11. Place manual release/safety reverse test label in
plain view on inside of garage door.
12. Upon completion of installation, test safety
reversal system. Door MUST reverse on contact
with a 1-1/2" (3.8 cm) high object (or a 2x4 laid
fl at) on the fl oor.
13. To avoid SERIOUS PERSONAL INJURY or
DEATH from electrocution, disconnect ALL
electric and battery power BEFORE performing
ANY service or maintenance.
14. DO NOT install on a one-piece door if using
devices or features providing unattended close.
Unattended devices and features are to be used
ONLY with sectional doors.
15.
SAVE THESE
INSTRUCTIONS.
3
Important Safety Instructions
WARNING
WARNING
WARNING
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of
children. NEVER permit children to operate or
play with garage door control push buttons or
remote controls.
3. ONLY activate garage door when it can be seen
clearly, it is properly adjusted, and there are no
obstructions to door travel.
4. ALWAYS keep garage door in sight and away
from people and objects until completely closed.
NO ONE SHOULD CROSS THE PATH OF THE
MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED,
PARTIALLY OPENED DOOR.
6. If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Use caution when using this release
with the door open. Weak or broken springs or
unbalanced door could result in an open door
falling rapidly and/or unexpectedly and increasing
the risk of SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless
garage doorway is clear of persons and
obstructions.
8. NEVER use handle to pull garage door open or
closed. If rope knot becomes untied, you could
fall.
9. After ANY adjustments are made, the safety
reversal system MUST be tested.
10. Safety reversal system MUST be tested every
month. Garage door MUST reverse on contact
with 1-1/2" high (3.8 cm) object (or a 2x4 laid
fl at) on the fl oor. Failure to adjust the garage
door opener properly increases the risk of
SEVERE INJURY or DEATH.
11. ALWAYS KEEP GARAGE DOOR PROPERLY
BALANCED. An improperly balanced door may
NOT reverse when required and could result in
SEVERE INJURY or DEATH.
12. ALL repairs to cables, spring assemblies
and other hardware, ALL of which are under
EXTREME tension, MUST be made by a trained
door systems technician.
13. ALWAYS disconnect electric power to garage
door opener BEFORE making ANY repairs or
removing covers.
14. This operator system is equipped with an
unattended operation feature. The door could
move unexpectedly. NO ONE SHOULD CROSS
THE PATH OF THE MOVING DOOR.
15. DO NOT install on a one-piece door if using
devices or features providing unattended close.
Unattended devices and features are to be used
ONLY with sectional doors.
16.
SAVE THESE
INSTRUCTIONS.
4
Operation
Your garage door opener is equipped with features to
provide you with greater control over your garage door
operation.
ALERT2CLOSE
The Alert2Close feature provides a visual and an audible
alert that an unattended door is closing.
TIMER-TO-CLOSE (TTC)
The Timer-to-Close feature automatically closes the door
after a specifi ed time period that can be adjusted using a
TTC enabled door control (Models 881LMW or 880LM).
Prior to and during the door closing the garage door
opener lights will fl ash and the garage door opener will
beep.
®
MyQ
MyQ® technology uses a 900MHz signal to provide twoway communication between the garage door opener and
MyQ® enabled accessories. Your garage door opener is
compatible with up to 16 MyQ® accessories.
SECURITY+ 2.0
®
REMOTE CONTROLS AND DOOR
CONTROLS
Your garage door opener has already been programmed
at the factory to operate with your remote control, which
changes with each use, randomly accessing over 100
billion new codes. Compatible with MyQ
®
and
Security+ 2.0® accessories, see page 17.
NOTE: Older LiftMaster remote controls, door controls,
and third party products are not compatible.
Security+ 2.0
Accessories
®
MEMORY CAPACITY
Remote Controls Up to 12
Door ControlsUp to 2 Smart Control Panels or 4
of any other Security+ 2.0
®
door
controls
Keyless EntriesUp to 1
®
THE PROTECTOR SYSTEM
(SAFETY REVERSING
SENSORS)
When properly connected and aligned, the safety
reversing sensors will detect an obstruction in the path
of the infrared beam. If an obstruction breaks the infrared
beam while the door is closing, the door will stop and
reverse to full open position, and the opener lights will
fl ash 10 times. If the door is fully open, and the safety
reversing sensors are not installed, or are misaligned,
the door will not close from a remote control. However,
you can close the door if you hold the button on the door
control or keyless entry until the door is fully closed. The
safety reversing sensors do not affect the opening cycle.
ENERGY CONSERVATION
For energy effi ciency the garage door opener will enter
sleep mode when the door is fully closed. The sleep mode
shuts the garage door opener down until activated. The
sleep mode is sequenced with the garage door opener
light bulb; as the light bulb turns off the sensor LEDs will
turn off and whenever the garage door opener lights turn
on the sensor LEDs will light. The garage door opener will
not go into the sleep mode until the garage door opener
has completed 5 cycles upon power up.
LIGHTS
The garage door opener light bulbs will turn on when
the opener is initially plugged in; power is restored after
interruption, or when the garage door opener is activated.
The lights will turn off automatically after 4-1/2 minutes.
An incandescent A19 light bulb (100 watt maximum) or
for maximum energy effi ciency a 26W (100W equivalent)
compact fl uorescent light (CFL) bulb may be used.
Light Feature
The garage door opener is equipped with an added
feature; the lights will turn on when someone enters
through the open garage door and the safety reversing
sensor infrared beam is broken. For added control over
the light bulbs on your garage door opener.
USING YOUR GARAGE DOOR OPENER
The garage door opener can be activated through a
wall-mounted door control, remote control, or wireless
keyless entry. When the door is closed and the garage
door opener is activated the door will open. If the door
senses an obstruction or is interrupted while opening the
door will stop. When the door is in any position other
than closed and the garage door opener is activated the
door will close. If the garage door opener senses an
obstruction while closing, the door will reverse. If the
obstruction interrupts the sensor beam the garage door
opener lights will blink 10 times. However, you can close
the door if you hold the button on the door control or
keyless entry until the door is fully closed. The safety
reversing sensors do not affect the opening cycle. The
safety reversing sensor must be connected and aligned
correctly before the garage door opener will move in the
down direction.
5
Operation
Using the Door Control
SYNCHRONIZE THE DOOR CONTROL
To synchronize the door control to the garage door
opener, press the push bar or push button until the
garage door opener activates (it may take up to 3
presses). Test the door control by pressing the push
bar or push button, each press of the push bar or push
button will activate the garage door opener.
Push Bar
SERVICE
LED
LEARN
Button
LOCK
Button
COMMAND
LED
LIGHT
Button
Push
Button
Light
Button
LOCK
The LOCK feature is designed to prevent activation of
the garage door opener from remote controls while still
allowing activation from the door control and keyless
entry. This feature is useful for added peace of mind
when the home is empty (i.e. vacation).
AUTOMATIC LIGHT
Light Feature
The lights will turn on when someone enters through
the open garage door and the safety reversing sensor
infrared beam is broken.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the
garage door opener system stays in good working
condition. When the garage door opener needs to be
serviced (approximately 4500 garage door opener cycles)
the command (yellow) and service (red) LEDs will begin
to alternately fl ash back and forth. The factory setting for
the MAS feature is off and can be activated at time of
installation. Contact your installing dealer for service.
Programming - Push Button Door
Control
Push
Button
Light
Button
PUSH BAR OR PUSH BUTTON
Press the push bar or push button to open or close the
door.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener
lights on or off. When the lights are turned on they will
stay on until the LIGHT button is pressed again, or until
the garage door opener is activated. Once the garage
door opener is activated the lights will turn off after the
specifi ed period of time (the factory setting is 4-1/2
minutes). The LIGHT button will not control the lights
when the door is in motion.
The following features are accessible by lifting the
push bar (multi-function door control only):
LEARN A DEVICE
Any compatible remote controls or wireless keyless
entries can be programmed to the garage door opener by
pressing the LEARN button on the Multi-Function Control
Panel.
Feature
To Program
a Remote
Control or
Keyless
Entry
6
1. Press and hold the Light button and
the Push button until the Push button
LED begins to blink.
2. Remote Control: Press the button on
the remote control that you wish to
operate your garage door.
Keyless Entry: Enter a 4-digit personal
identifi cation number (PIN) of your
choice on the keyless entry keypad.
Then press the ENTER button.
The garage door opener lights will fl ash
(or two clicks will be heard) when the
code has been programmed.
Operation
Programming - Multi-Function Control Panel
Service
LED
LEARN
Button
LOCK
Button
Features
LockNOTE: Your remote controls will NOT work when LOCK mode is active however your keyless entry will
LightTo change the amount of time the garage door opener lights will stay on (default time is 4-1/2
To Program
a Remote
Control or
Keyless Entry
Maintenance
Alert System
(MAS)
still allow access to your garage.
Activate: Press and hold the LOCK button for 2 seconds. The command LED will fl ash as long as the
lock feature is activated and your handheld remote control will not operate your door at this time.
Deactivate: Press and hold the LOCK button again for 2 seconds. The command LED will stop
fl ashing and normal operation will resume.
Minutes):
Press and hold the LOCK button until the garage door opener lights fl ash.* The garage door opener
lights will then indicate the current light duration by fl ashing up to 4 times (see table below).
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH1234
TIME THE GARAGE DOOR OPENER LIGHT STAYS ON1½ Minutes 2½ Minutes 3½ Minutes 4½ Minutes
To change the light duration time repeat the steps above until the lights fl ashes indicate your desired
time frame.
NOTE: Factory setting is on.
This feature will turn on the garage door opener lights when the safety reversing sensors beam has
been broken.
Deactivate: Start with the garage door opener lights off. Press and hold the LIGHT button to turn on
the light, continue to hold until the light turns off.*
Activate: Start with the garage door opener lights on. Press and hold the LIGHT button to turn off
the light, continue to hold until the light turns on.*
* Approximately 10 seconds
1. Press the LEARN button on the door control twice. The Command LED will blink.
2. Remote Control: Press and release the button on the remote control that you wish to operate your
garage door.
Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) on the keypad. Then press the
ENTER button.
The garage door opener lights will fl ash (or two clicks will be heard) and the Command LED will stop
blinking when the code has been programmed.
Activate/Deactivate
NOTE: Factory setting is on.
Press and hold the LEARN button. Then press the LIGHT button. The service LED will fl ash the
status; Activated is 2 fl ashes and deactivated is 3 fl ashes.
Command LED
LIGHT
Button
7
Operation
Programming - Remote Controls
Your garage door opener has been programmed at the factory to operate with your remote control. Older LiftMaster
remote controls are NOT compatible. Programming can be done through the door control or the Learn button on the
garage door opener. To program additional remote controls refer to the instructions provided with the additional remote
controls or visit LiftMaster.com. If your vehicle is equipped with HomeLink®, a Compatability BridgeTM (not included)
may be necessary for certain vehicles. Visit bridge.LiftMaster.com to fi nd out if a Bridge is needed.
NOTE: The products illustrated in the instructions are for reference. Your product may look different.
PROGRAM A REMOTE USING THE LEARN BUTTON ON THE GARAGE DOOR OPENER
1 Locate the Learn button.
3 Press and hold the button on the remote control that
you wish to use.
Release the button when the garage door opener
lights blink or two clicks are heard.
If programming to other products, press the button a
second time to activate products.
ERASE ALL DEVICES (INCLUDING MYQ® ENABLED ACCESSORIES)
2 Press and immediately release the Learn button.
The Learn LED will glow steady for 30 seconds.
Within 30 seconds...
“click”
“click”
1 Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds).
2 Immediately press and hold the learn button again until the learn LED goes out. All codes are now erased.
Reprogram any accessory you wish to use.
8
Operation
To Open the Door Manually
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
• NEVER use emergency release handle unless
garage doorway is clear of persons and
obstructions.
• NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
DISCONNECT THE TROLLEY
1 The door should be fully
closed if possible.
2 Pull down on the emergency
release handle.
RECONNECT THE TROLLEY
The lockout feature prevents
the trolley from reconnecting
automatically.
1 Pull the emergency release
handle down and back
(toward the opener). The
door can then be raised and
lowered manually as often as
necessary.
2 To disengage the lockout feature, pull the handle
straight down.
The trolley will reconnect on the next UP or DOWN
operation, either manually or by using the door control or
remote control.
9
Adjustment
Introduction
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
• Incorrect adjustment of garage door travel limits
will interfere with proper operation of safety
reversal system.
• After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" (3.8 cm) high object
(or 2x4 laid fl at) on fl oor.
To prevent damage to vehicles, be sure fully open
door provides adequate clearance.
Your garage door opener is designed with electronic
controls to make setup and adjustments easy. The
adjustments allow you to program where the door will
stop in the open (UP) and close (DOWN) position. The
electronic controls sense the amount of force required to
open and close the door.
NOTE: If anything interferes with the door’s upward
travel it will stop. If anything interferes with the door’s
downward travel, it will reverse.
To watch a short instructional video on programming
your new garage door opener use your smartphone to
read the QR Code below:
UP (Open)
PROGRAMMING BUTTONS
The programming buttons are located on the left side panel of the garage door opener and are used to program the travel.
PROGRAMMING BUTTONS
10
DOWN (Close)
UP Button
Adjustment Button
DOWN Button
Adjustment
Program the Travel
1
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY
INJURED or KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with
1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
1.1 Press and hold the
Adjustment Button
until the UP Button
begins to fl ash and/or
a beep is heard.
1.3 Once the door is in the
desired UP position press
and release the Adjustment
Button. The garage door
opener lights will fl ash
twice and the DOWN
Button will begin to fl ash.
1.5 Once the door is in the
desired DOWN position
press and release the
Adjustment Button. The
garage door opener lights
will fl ash twice and the UP
Button will begin to fl ash.
1.2 Press and hold the UP Button until the door is
in the desired UP position.
NOTE: The UP and DOWN Buttons can be used to
move the door up and down as needed.
1.4 Press and hold the DOWN Button until the door
is in the desired DOWN position.
NOTE: The UP and DOWN Buttons can be used to
move the door up and down as needed.
1.6 Press and release the UP Button. When the door
travels to the programmed UP position, the
DOWN Button will begin to fl ash.
1.7 Press and release the DOWN Button. The door
will travel to the programmed DOWN position.
Programming is complete.
If the garage door opener lights are fl ashing 5
times during the steps for Program the Travel, the
programming has timed out. If the garage door opener
lights are fl ashing 10 times during the steps for Program
the Travel, the safety reversing sensors are misaligned
or obstructed. When the sensors are aligned and
unobstructed, cycle the door through a complete up
and down cycle using the remote control or the UP and
DOWN buttons. Programming is complete. If you are
unable to operate the door up and down, repeat the steps
for Program the Travel.