LG SP092CN Owner's Manual

ESPAÑOL
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating your set and retain it for future reference.
TYPE:WALL MOUNTED
MODELS:
NY0
SP091CN
P/NO:MFL68070401
SP091CN SP092CNSP092CN
UY0
UY0
SP091CN SP092CN
US1
US0NY0
www.lg.com
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
A. Safety Precautions ..............................3
B. Electrical Safety...................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
C. Product Introduction...........................7
Indoor Units ...........................................7
Operation Indication Lamps ..................8
Outdoor Unit ..........................................8
D. Operating Instructions........................9
How to insert the Batteries ....................9
Wireless Remote Controller
Maintenance..........................................9
Operating Method..................................9
Wireless Remote Controller
Cooling Only Model ..........................10
Wireless Remote Controller
Heat Pump Model .............................11
Operation Mode...................................12
Auto Operation.....................................13
Healthy Dehumidification Operation
Air Circulation Operation
.....13
.....................14
Auto Clean Operation..........................14
Display Luminosity(Optional) ..............14
Setting the Current Time......................14
Timer Setting Operation
......................15
To Cancle The Timer Setting...............15
Sleep Mode .........................................15
Airflow Direction Control Jet Cool
...............................................17
......................
16
Forced Operation.................................17
E. Maintenance and Service..................18
Indoor Unit...........................................18
Outdoor Unit ........................................20
Operation Tips!....................................20
Self-Diagnosis Function ......................20
Troubleshooting Tips!
Save time and money!.........................21
Call the service immediately in the
following situations ..............................21
Spec sheet...........................................22
FOR YOUR RECORDS
Write the model and serial numbers here:
Model # Serial #
You can find them on a label on the side of each unit.
Dealer's Name Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You’ll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips
for service at all.
first, you may not need to call
PRECAUTION
Contact the authorized service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by authorized personnel only using only genuine replacement parts.
This appliance is not intended for use by persons (including children) with reduced physical,sen­sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING: Before accessing the terminals, all
WARNING: Fixed installations will incorporate
WARNING: This device will not be accessible to
WARNING: The appliance must be installed in
power circuits must be disconnected.
disconnect means in accordance with installation rules.
public.
accordance with national regulations for electrical installations.
2 Room Air Conditioner
Plug in the power plug properly.
Otherwise, it will cause electric shock or fire due to heat generation or electric shock.
Do not operate or stop the unit by inserting or pulling out the power plug.
It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
It will cause electric shock or fire. In the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly quallfied order to avoid a hazard.(Y Attachment)
Do not modify power cord length or share the outlet with other appliances.
It will cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not direct airflow at room occupants only.
This could damage your health.
Always perform grounding work.
No grounding may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Always install air leakage breaker and a dedicated switching board.
No installation may cause fire and electric shock accident.
Unplug the unit if strange sounds,smell,or smoke comes from it.
It may cause fire and electric shock accident.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not open the entrance during operation.
It may cause electric shock.
Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.
Improper or loose connections can cause heat generation or fire. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags.
Children may play with them and cause injury. Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the
plug completely.
Dirty, loose or broken power plug can cause electric shock or fire. Be sure to check the refrigerant to the used. Please read the label on the product.
Incorrect refrigerant used can prevent the normal operation of the unit. Don’t use a power cord, a plug or a loose socket which is damaged.
Otherwise it may cause a fire or electrical shock. Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out.
There is risk of electric shock or fire. Do not place a heater or other heating appliances near the power cable.
There is risk of fire and electric shock. Do not allow water to run into electric parts.Install the unit away from water sources.
There is risk of fire, failure of the product, or electric shock. Do not store or use or even allow flammable gas or combustibles near the product.
There is risk of fire. Do not use the product in a tightly closed space for a long time. Perform ventilaion regularly.
Oxygen deficiency could occur and hence harm your health. Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure. If strange sounds, smell or smoke comes from product. Immediately turn the breaker off or disconnect the power supply cable.
There is risk of electric shock or fire.
Ventilate the product room from time to time when operating it together with a stove, or heating
element etc.
Oxygen deficiency can occur and hence harm your health. Turn the main power off and unplug the unit when cleaning or repairing the product.
There is risk of electric shock. When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker.
There is risk of product damage or failure, or unintended operation. Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
This could result in personal injury and product damage. Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock. Do not place ANYTHING on the power cable.
There is risk of fire or electric shock. Do not plug or unplug the power supply plug to turn the unit ON/OFF.
There is risk of fire or electric shock. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire. For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of product, fire, or electronic shock.
Two or more peopie must lift and transport the product.
Avoid personal injury. Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Install the drain hose to ensure that the condensed water is drained away properly.
A bad connection may cause water leakage.
Keep level even when installing the product.
To avoid vibration or noise. Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.
It may cause a problem for your neighbors and hence dispute. Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product. Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a
consumer air conditioner, not a precision refrigeration system.
There is risk of damage or loss of property. Do not block the inlet or outlet of air flow.
It may cause product failure. Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product. Do not touch the metal parts of the product when removing the air filter.
There is risk of personal injury. Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product. Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if
necessary.
A dirty filter reduces the efficiency.
Do not insert hands or other objects through the air inlet or outlet while the product is operating.
There are sharp and moving parts that could cause personal injury. Be cautious when unpacking and installing the product.
Sharp edges could cause injury. If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.
The refrigernat gas can cause frostbite (cold burn) Do not tilt the unit when removing or uninstalling it.
The condensed water inside can spill. Do not mix air or gas other than the specified refrigerant used in the system.
If air enters the refrigerant system, an excessiveiy high pressure results, causing equipment damage or injury. If the refrigerant gas leaks during the installation, ventilate the area immediately.
Otherwise it can be harmfull for your health. Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in
accordance with local and national standards. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and
new batteries or different types of batteries.
There is risk of fire or product failure. Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire.
There may bum or explode. If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other health hazards. Do not let the air conditioner run for a long time when the humidity is very high and a door or a
window is left open.
Moisture may condense and wet or damage furniture. Do not expose your skin or kids or plants to the cool or hot air draft.
This could harm to your health. Do not drink the water drained from the product.
It is not sanitary and could cause serious health issues. Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
Be careful and avoid personal injury.
WARNING: Before accessing the terminals, all power circuits must be disconnected.
WARNING: This device will not be accessible to public.
WARNING: The appliance must be installed in accordance with national regulations for electrical
installations.
6 Room Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards.
Temporary Use of an Adapter
Temporary Use of an Extension Cord
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
Product Introduction
Product Introduction
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.
Indoor Units
Standard Split Type
Display panel LED indicators
Air Inlet
Front Panel
ON/OFF Button
Art Cool Type Wide
Art Cool Deluxe(Type 1) Display panel LED indicators
Air discharge
Front panel
Signal receiver
Air Filter
Air inlet
Plasma filter
Air filter
Power cord
ON/OFF button
Signal Receptor
Art Cool Deluxe(Type 2) Display panel LCD indicators
Air discharge
Front panel
Signal receiver
Air inlet Air filter
Plasma filter
Power cord ON/OFF button
Owner's Manual 7
Product Introduction
Operation Indication Lamps
On/Off
: Lights up during the system operation, error code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation.(non-Inverter Model)
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
: Lights up during timer operation.(non-Inverter Model) Lights up during timer operation or sleep mode auto operation (Inverter Model only)
: Lights up during defrost mode or hot start operation (Heat pump model only) : Lights up during outdoor unit operation. (Cooling model only)
OUT
DOOR
Timer
Defrost mode Outdoor unit
operation
Power Display : Indicates the setting temperature and operation mode.
Operation
mode
Shape of
display
Cooling, heating, Dehumidification
temperature
Standard Too hot Hot Cold Too cold
Mode
Setting
Auto operation mode
Comfortable
Jet
Cool/Heat
Energy-saving cooling mode
Test
operation
Auto
clean
! Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out
from unit. ! In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency.
Outdoor Unit
Air intake vents
Connecting wires
Air outlet vents
Base plate
8 Room Air Conditioner
Refrigerant pipes
Drain hose
Operating Instructions
Operating Instructions
How to insert the Batteries
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3. Reattach the cover by sliding it back into position.
NOTE
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
4. Use 2 AAA(1.5 volt) batteries.
Wireless Remote Controller Maintenance
1. Choose a suitable place where its safe & easy to reach.
2. Fix the holder to wall etc with the supplied screws firmly.
3. Slide the remote controller inside the holder.
NOTE
1. Remote controller should never be exposed to direct sunlight.
2. Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.
Operating Method
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it. There should not be any blockage in between.
Owner's Manual 9
Operating Instructions
Wireless Remote Controller (Cooling Only Model)
The controls will look like the following.
ON/OFF BUTTON
Used to turn off/on the unit.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTION BUTTON
Used to select fan speed in four steps low, medium, high and natural wind.
HORIZONTAL VANE CONTROL BUTTON
Used to set the desired vertical airflow direction.
AUTO CLEAN
AUTO CLEAN BUTTON
Used to set auto clean.
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
ON/OFF TIMER BUTTONS
ON
Used to set the time of starting and stopping operation.
OFF
TIME SETTING BUTTONS
Used to adjust the time.
CANCEL
TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
SET
RESET BUTTON
Used prior to resetting time.
LED LUMINOSITY BUTTON (OPTIONAL)
Used to adjust LED luminosity.
SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating.
JET COOL BUTTON
Used to start or stop the speed cooling. The Jet Cool operates fan in super high speed in cooling mode.
2nd F BUTTON
Used prior to using modes printed in blue at the bottom of buttons.
15
5
4
2 8
14
ON
OFF
AUTO CLEAN
9
11
Operation Mode
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Signal transmitter
CANCEL
SET
Flip-up door (opened)
13 10
1
16
1
3
7
6 2
NOTE
To use the functions printed in blue at the bottom of the buttons press 2ndF button first and then the required function button. Pressing the 2 press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.
Room Air Conditioner10
nd
F button activates the blue printed function of the respective button. To cancel the function
Wireless Remote Controller (Heat Pump Model)
ENGLISH
Operating Instructions
The controls will look like the following.
Signal transmitter
15
5
4 2
8
ON
14
OFF
CANCEL
SET
AUTO CLEAN
9
13 11
Flip-up door (opened)
Operation Mode
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Heating Operation
13 10
12
16
ON/OFF BUTTON
Used to turn off/on the unit.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTION BUTTON
Used to select fan speed in four steps low, medium, high and natural wind.
1
3
7 6
HORIZONTAL VANE CONTROL BUTTON
Used to set the desired vertical airflow direction.
AUTO CLEAN
AUTO CLEAN BUTTON
Used to set auto clean.
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
ON/OFF TIMER BUTTONS
ON
Used to set the time of starting and stopping operation.
OFF
TIME SETTING BUTTONS
Used to adjust the time.
CANCEL
TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
SET
RESET BUTTON
Used prior to resetting time.
LED LUMINOSITY BUTTON (OPTIONAL)
Used to adjust LED luminosity.
SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating.
JET COOL BUTTON
Used to start or stop the speed cooling. The Jet Cool operates fan in super high speed in cooling mode.
2nd F BUTTON
Used prior to using modes printed in blue at the bottom of buttons.
ENGLISH
ENGLISH
NOTE
To use the functions printed in blue at the bottom of the buttons press 2ndF button first and then the required function button. Pressing the 2 press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.
nd
F button activates the blue printed function of the respective button. To cancel the function
Owner's Manual 11
Operating Instructions
Operation Mode
Press the ON/OFF BUTTON to Turn on the unit
1
The unit will respond with a beep.
Open the cover of the remote controller and press the operation mode button. Each time
2
the button is pressed, the operation mode is shifted in the direction of the arrow. (For Heating Model)
Cooling Auto Operation
Open the cover of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
(For Cooling Model)
Cooling
For cooling or heating operation set the desired indoor
3
temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18°C~30°C and for heating the temperature range is 16°C~30°C.
Set the fan speed with the remote controller.
4
You can select the fan speed in four steps : low, medium, high and natural wind by pressing the INDOOR FAN SPEED SELECTION BUTTON Each time the button is pressed, the fan speed mode is shifted in the direction of the arrow.
Auto Operation
Healthy
Dehumidification
Healthy
Dehumidification
Heating
(Heat pump model only)
Step1(Low) Step2(Medium) Step3(High)Natural Wind
Natural wind
For fresher feeling, press the INDOOR FAN SPEED SELECTION BUTTON and set to Natural wind mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed.
Room Air Conditioner12
Auto Operation
ENGLISH
Operating Instructions
<For Cooling Model>
The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect. You cannot switch the indoor fan speed. It has already been set by the Auto Operation Mode rule.
Please select the code
as per your requirement.
Code Feel Cold Slightly cool Neutral Slightly warm Warm
<For Heating Model>
You can set desired temperature and indoor fan speed. Setting Temp. Range : 18~30°C.
NOTE
: You can not set the actual setting temperature and the fan
speed in this operation mode. But you can use the Auto swing in this operation. If the system is not operating as desired, switch manually to another mode
Healthy Dehumidification Operation
ENGLISH
During Healthy Dehumidification Operation
If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification
function. It automatically sets the room temperature and airflow volume to the best
condition for dehumidification, based on the sensed current room temperature. In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either.
During the healthy dehumidification function, the fan speed is automatically set
according to the optimization algorithm responding to the current room
temperature status, so that the room condition is kept healthy and comfortable
even in the very humid season.
13Owner’s Manual
Operating Instructions
NOTE
Air Circulation Operation
This operation circulates the air without cooling or heating. It can be activated by pressing the AIR CIRCULATION BUTTON. Once the air circulation is activated you can select the fan speed by pressing the INDOOR FAN SPEED SELECTION BUTTON.
Auto Clean Operation
During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed.
Select Auto Clean Operation by the function setting button( ).
Now whenever the unit is turned off, the indoor fan is still running for
about 30 minutes internally without cooling or dehumidification
operation. This function dries up any remains of moisture & cleans
the unit internally. If you push the Auto Clean button again, this function is
cancelled.
During Auto Clean fuction, only ON/OFF button, Plasma button, Auto Clean button is used. During this operation, 'Cooling Lamp' lights up.
Display LuminosityOptional
AUTO CLEAN
AUTO CLEAN
The unit display luminosity can be adjusted by using the remote controller. Open the cover of the remote controller and press the LED LUMINOSITY BUTTON. Display LED will be off. Press the button again to set bright display.
Setting the Current Time
Time can be set only when you press the RESET BUTTON.
1
Having replacing the batteries, you should press the RESET BUTTON to reset the time. Press the ON/OFF BUTTON.
Press 2ndF button and check if icon is on.
2
Press the TIME SETTING BUTTONS until the desired time is set.
3
Press the TIMER SET/CANCEL BUTTON.
4
NOTE
Room Air Conditioner14
Check the indicator for a.m. and p.m.
CANCEL
SET
Loading...