Lg Arnu073sel2, Arnu093sel2, Arnu123sel2, Arnu153sel2 Installation Guide

Page 1
ENGLISH
System
Indoor Unit (2 Series)
INSTALLATION MANUAL
LG
Type: Wall Mounted
IMPORTANT
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
ENGLISH FRANÇAIS ESPAÑOL
Page 2
2 Indoor Unit
IMPORTANT!
CAUTION
: Improper installation, adjustment, alteration, service or maintenance can void the warranty.
The weight of the condensing unit requires caution and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.
Safety Precautions
• Always wear safety eye wear and work gloves when installing equipment.
• Never assume electrical power is disconnected. Check with meter and equipment.
• Keep hands out of fan areas when power is connected to equipment.
• R-410A causes frostbite burns.
• R-410A is toxic when burned.
NOTE TO INSTALLING DEALER: The Owners Instructions and Warranty are to be given to the owner
or prominently displayed near the indoor Furnace/Air Handler Unit.
When wiring:
Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.
• Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.
• Ground the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
When transporting:
Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.
When installing...
... in a wall: Make sure the wall is strong enough to hold the unit's weight.
It may be necessary to construct a strong wood or metal frame to provide added support.
... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause
dripping and water damage to wall and floors.
... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid,
level foundation for the outdoor unit. This prevents water damage and abnormal vibration.
... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is
higher than drifting snow. Provide snow vents.
When connecting refrigerant tubing
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Check carefully for leaks before starting the test run.
When servicing
• Turn the power OFF at the main power box(mains) before opening the unit to check or repair
electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have
been left inside the unit being serviced.
Special warnings
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others. Installation MUST conform with local building codes or, in the absence of local codes, with the National Electrical Code NFPA 70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Please read this instruction sheet completely before installing the product.
This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
Page 3
Installation Manual 3
ENGLISH
Wall Mounted Type Indoor Unit Installation Manual
TABLE OF CONTENTS
Installation guide mapFour type "A" screws & plastic
anchors
Connecting cable
Pipes: Gas side
Liquid side (Refer to Product Data)
Insulation materialsAdditional drain pipe
Two type "B" screws
Level gaugeScrew driverElectric drillHole core drillHorizontal meter
Flaring tool setSpecified torque wrenches
(different depending on model No.)
Spanner.......Half union
A glass of waterScrew driver
Hexagonal wrenchGas-leak detectorVacuum pumpGauge manifold
Owner's manualThermometerHolder Remote Controller
Installation Parts ....................4
Safety Precautions.................5
Installation
Selection the best location ....8
Piping Method........................9
Drain Piping .........................14
Wiring Connection ...............14
Installation of wirelss
remote controller..................16
Installation of Wired
Remote Controller ...............17
Optional Operation of Wired
Remote Controller ...............19
Group Control Setting .........20
Installation Requirements
Required Parts Required Tools
Page 4
4 Indoor Unit
Installation Parts
Type "A" screw (6 EA) Type "B" screw (2 EA)
Conduit mounting plate(1EA) Conduit mounting plate(1EA)
SE S5
Installation plate(1EA) Installation plate(1EA)
Type "A" screw (6 EA) Type "B" screw (2 EA)
Installation Parts
Page 5
Installation Manual 5
ENGLISH
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Be sure to read before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the
following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
Installation
Do not use a defective or under­rated circuit breaker. Use this appliance on a dedicated circuit.
• There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electri­cian, or an Authorized Service Center.
• Do not disassemble or repair the product. There is risk of fire or elec­tric shock.
Always ground the product.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Always install a dedicated cir­cuit and breaker.
• Improper wiring or installation may cause fire or electric shock
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Page 6
6 Indoor Unit
Safety Precautions
Operation
Do not modify or extend the power cable.
• There is risk of fire or electric shock.
Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage furniture.
Be cautious when unpacking and installing the product.
• Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always contact the dealer or an Authorized Service Center.
• There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
• It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
• If the base collapses, the air condi­tioner could fall with it, causing prop­erty damage, product failure, and personal injury.
Do not store or use flammable gas or combustibles near the product.
• There is risk of fire or failure of product.
Gasolin
Page 7
Installation Manual 7
ENGLISH
Safety Precautions
Always check for gas (refriger­ant) leakage after installation or repair of product.
• Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away prop­erly.
• A bad connection may cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the product where the noise or hot air from the out­door unit could damage the neighborhoods.
• It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
• Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product. Corrosion, particularly on the con­denser and evaporator fins, could cause product malfunction or inefficient operation.
Installation
If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
90˚
Page 8
8 Indoor Unit
Installation
Read completely, then follow step by step.
Installation
Selection of the best location
There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into con­sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles.
The mounting wall should be strong and solid enough to protect it from the vibration.
Front
Right Rear right
Rear left
Down right
Left
Fixing Installation Plate
The wall you select should be strong and solid enough to prevent vibration
1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a con­crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also important to use caution concerning the loca­tion of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely.
Chassis
Hook
Installation Plate
Type A
Chassis
Hook
Installation Plate
Type A
Installation plate
Left rear piping
Right rear piping
Ø70mm
(Ø2-9/16 inch)
Ø70mm (Ø2-9/16 inch)
D
B
A
C
Installation plate
Left rear piping Right rear piping
Ø70mm
(Ø2-9/16 inch)
133mm
Ø70mm (Ø2-9/16 inch)
100mm
<S5>
<SE>
<S5>
<SE>
ABCD
SE
70(2-9/16) 110(4-5/15) 90(3-7/13) 110(4-5/15)
S5
100(3-15/16) 122(4-4/15) 240(9-7/16) 122(4-4/5)
CHASSIS
Distance [mm(inch)]
More than
100 mm
Higher than eye-level
Lower than 2.3m More than 200 mm
More than
100 mm
Page 9
Installation Manual 9
ENGLISH
Installation
Piping Method
CAUTION : When
install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable.
Preparing the indoor unit's piping and drain hose for
installation through the wall.
Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away from chassis.
Replace the plastic tubing holder in the original position.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy connection
later.
Drill a hole in the wall
• Drill the piping hole with a ø70mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.
3. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.
: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that drip­ping from "sweating"(condensation) will not damage furni­ture or floors.
*Foamed polyethylene or equivalent is recommended.
4. Indoor unit installation
Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).
5. Connecting the pipings to the indoor unit and drain hose to drain pipe.
Align the center of the pipings and sufficiently tighten the flare nut by hand.
NOTICE
For left rear piping
Tubing holder
To remove the holder, press the bottom of chassis near the holder upward and pull the tab out of its hole.
1
Press
2
Pull
Loop
Connecting cable
Drain hose
Gas side piping
Liquid side piping
Connecting
cable
Drain hose
Indoor
WALL
Outdoor
5-7mm
(3/16"~5/16")
Drain hose
Indoor unit tubing
Flare nut Pipings
Page 10
10 Indoor Unit
Installation
Tighten the flare nut with a wrench.
When extending the drain hose at the indoor unit,
install the drain pipe.
6. Wrap the insulation material around the connect­ing portion.
Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap.
Wrap the area which accommodates the rear pip­ing housing section with vinyl tape.
Bundle the piping and drain hose together by wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec­tion.
1. Route the indoor tubing and the drain hose to the required piping hole position.
2. Insert the piping, drain hose and the connecting cable into the piping hole.
For right rear piping
Spanner (fixed)
Flare nut
Torque wrench
Indoor unit tubing
Drain pipe
Vinyl tape(narrow)
Adhesive
Connection pipe
Indoor unit drain hose
Connection pipe
Vinyl tape (wide)
Wrap with vinyl tape
Connecting cable
Vinyl tape(narrow)
Indoor unit pipe
Pipe
Pipe
Drain hose
Wrap with vinyl tape
Vinyl tape(wide)
Plastic bands
Insulation material
Connecting cable
Drain pipe
Page 11
Installation Manual 11
ENGLISH
Installation
3. Insert the connecting cable into the indoor unit.
Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cable.
• Connecting cable
5. Indoor unit installation
Hang the indoor unit from the hooks at the top of the installation plate.
Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of
the indoor unit from the wall.
6. Connecting the pipings to the indoor unit and the drain hose to drain pipe.
Align the center of the pipings and sufficiently
tighten the flare nut by hand.
Tighten the flare nut with a wrench.
When extending the drain hose at the indoor unit,
install the drain pipe.
7. Wrap the insulation material around the connect­ing portion.
Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no gap.
Wrap the area which accommodates the rear pip­ing housing section with vinyl tape.
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
Plastic bands
Insulation material
Vinyl tape (narrow)
Connection pipe
Connecting cable
Indoor unit piping
Pipe
Vinyl tape (wide)
Wrap with vinyl tape
Installation plate
Spacer
Indoor unit
8cm
Indoor unit tubing
Flare nut Pipings
Torque wrench
Indoor unit tubing
Spanner (fixed)
Connection pipe
Flare nut
Page 12
12 Indoor Unit
Installation
Bundle the piping and drain hose together by wrapping them with cloth tape over the range
within which they fit into the rear piping housing section.
8. Reroute the pipings and the drain hose across the back of the chassis.
9. Set the pipings and the drain hose to the back of the chassis with the tubing holder.
Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be
engaged at the bottom of chassis.
10. Indoor unit installation
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).
Drain hose
Vinyl tape (narrow)
Pipe
Wrap with vinyl tape(wide)
Drain hose
Connecting
cable
Piping for passage through piping hole
Tubing holder
Hook
Push
2
1
Page 13
Installation Manual 13
ENGLISH
Installation
Installation Information. For left piping. Follow the instruction below.
Good case
• Press on the upper side of clamp and unfold the tubing to downward slowly.
Bad case
• Following bending type from right to left may cause damage to the tubing.
Make the space between the tubing and the rear panel
Page 14
14 Indoor Unit
Terminal Block Indoor
INDOOR POWER INPUT
IDU IDU
Outdoor unit
Indoor unit
Central controller
SODU SODU
DRY1
DRY2
GND
INTERNET
12V
Outdoor unit
1(L1) 2(L2) 3(A) 4(B)
Installation
Drain Piping
Wiring Connection
1. To remove the front panel from the indoor unit, remove the front panel from the indoor unit cabinet.
Set the air direction louvers up-and-down to the position(horizontally) by hand.
Remove the securing screws that retain the front panel. Pull the lower left and right sides of the
grille toward you and lift it off. (2.1/7, 2.6/9, 3.5/12 kW/Btu models: 2EA,
3.5/18 kW/Btu models: 3EA)
2. To check the drainage.
Pour a glass of water on the evaporator.
Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out the drain exit.
1) Connect the wires to the terminals on the
control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
Screw
Pull the right and the left side.
Connecting cable
Remote control cordRemote control cordRemote control cord
Page 15
Installation Manual 15
ENGLISH
Installation
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification. (Particularly note the relation between cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors.
2) Attach the Grille onto the cabinet.
• Grasp lower the left and right side of the Grille and engage four tabs on the top inside edge of the chassis.
• Press the Grille toward the chassis until it will be back into place.
WARNING : Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazzard may also exist. Therefore, be sure all wiring is tightly connected.
Connection method of the connecting cable(Example)
Lock nut
Conduit
Conduit mounting plate
1(L1) 2(L2)
Power Supply
High Voltage
(208/230V)
4(B)
3(A)
Transmission
Conduit
Lock nut
Conduit mounting plate
Page 16
16 Indoor Unit
Installation
How to mount onto a wall
How to insert the batteries
Installation of wirelss remote controller
1. Remove the battery cover by pulling it according to the arrow direction.
2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the batteries to save their working life.
3. If the display screen of remote controller starts, fading replace both of the batteries.
NOTICE
Page 17
Installation Manual 17
ENGLISH
Installation
Installation of Wired Remote Controller
1. Connect the wired remote controller cable to the wired remote controller installation board as shown in the right picture.
2. After fixing the cable to the guide slot, attach the wired remote controller installa­tion board at the desired location.
• Before fixing the wired remote controller cable
to the guide slot, remove any clogged part of the case in the direction to install before the installation.
3. After locating the wired remote controller installation board at the desired location, screw the unit firmly. (When there is a buried box, install the wired remote con-
troller board to fit the buried box.)
• Use the screw provided.
4. After fixing the top part of the wired remote controller to the installation board as shown in beside picture, press the bottom part to assemble the con­troller to its board.
When disassemble the wired remote controller from the installation board, use the driver as shown in the right picture and insert it into the hole with the arrow. And when you pull the driver in the front direction, the wired remote controller will be separated.
12V Red wire
SIG Yellow wire
GND Black wire
The wired remote controller cable is connected as factory default.
12V SIG GND
Red Yellow Black
Remote Controller Cable
Guide slot
Fixate the remote controller cable to the guide slot.
Use the screws for fixate the unit firmly on the wall.
Installation board
<Front side of
installation board>
<Rear side of
installation board>
Top
Bottom
Wall Side
Wall Side
Wall Side
Wall Side
Wall
Side
Page 18
18 Indoor Unit
Installation
5. Use the connecting cable to connect the indoor unit and the wired remote controller.
6. When the distance between the wired remote controller and the indoor unit is 10m and above, use the extension cable.
When installing the wired remote controller, do not bury it in the wall. (It can cause damage in the temperature sensor.) Do not install the cable to be 50m or above. (It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be connected.
• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.
Check whether the connector is connected correctly.
Connecting cable
Indoor unit side
Page 19
Installation Manual 19
ENGLISH
Installation
Optional Operation of Wired Remote Controller
Function Code
04:01
Thermistor setting
1. Press button for 4 seconds to enter the installer setting mode until timer segment display “01:01”.
2. Repeat pressing button to select Function code 04.
3. Set Thermistor mode by pressing
button (01: Remote Controller, 02: Indoor, 03: 2TH)
4. Press button to save or release
5. Press button to exit or system will automatically exit after 25 seconds without any input.
Therefore system will use value that sensed from indoor unit or remote controller
If you want to know more Optional Operation, please refer to Wired Remote Controller Manual.
Two Thermistor System
Temperature sensor location Function
01 Remote controller Operation in remote controller Temperature sensor 02 Indoor unit Operation in indoor unit temperature sensor
03 2-Thermistor
Operation in lower temperature after comparing the temperature between the indoor unit and remote controller
Page 20
20 Indoor Unit
Installation
Group Control Setting
1. Group Control 1
Wired remote controller 1 + Indoor units
1. It is possible to 16 indoor units(Max) by one wired remote controller.
Set only one indoor unit to Master, set the others to Slave.
2. It is possible to connect with every type of indoor units.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
The Master indoor unit is possible to recognize Dry Contact and Central controller only.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
Exception of the error indoor unit, an individual indoor unit control possibility.
6. In case of Group Control, be limited additional functions of indoor unit.
- Selection of operation options (stop/mode/temperature)
- Control of flow rate (strong/middle/weak)
- Time reservation function
- Elevation grille
All kind of indoor units be set possible using a wireless remote controller, except cassette and duct types.
Refer to wireless remote controller manual for setting group control.
It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
GND Signal 12 V
Master
Slave
Slave
Slave
Master
Display Error Message
Only connect serial signal and GND lines
between slave indoor unit
LGAP Network System
Page 21
Installation Manual 21
Installation
ENGLISH
2. Group Control 2
Wired remote controllers + Indoor units
1. It is possible to control N indoor units by wired remote controller M units. (M+N17 Units)
Set only one indoor unit to Master, set the others to Slave. Set only one wired remote controller to Master, set the others to Slave. Other than those, it is same with the Group Control 1.
2. It is possible to connect with every type of indoor units.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
The Master indoor unit is possible to recognize Dry Contact and Central controller only.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
Exception of the error indoor unit, an individual indoor unit control possibility.
6. In case of Group Control, be limited additional functions of indoor unit.
- Selection of operation options (stop/mode/temperature)
- Control of flow rate (strong/middle/weak)
- Time reservation function
- Elevation grille
All kind of indoor units be set possible using a wireless remote controller, except cassette and duct types.
Refer to wireless remote controller manual for setting group control.
It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
GND Signal 12 V
SlaveSlaveSlave
Slave
Master
Display Error Message
Don’t connect serial 12V line
Master
LGAP Network System
Page 22
22 Indoor Unit
Installation
3. 2 Remote Control
Wired remote controller 2 + Indoor unit 1
1. It is possible to connect two wired remote controllers with one indoor unit.
2. Every types of indoor unit is possible to connect two remote controller.
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
5. In case of any error occurs at indoor unit, display on the wired remote controller.
6. There isnt limits of indoor unit function.
GND Signal 12 V
LGAP Network System
Display Error Message
Master
Master
Slave
Page 23
P/No.: MFL42803117
Printed in Korea
After reading this manual, keep it in a place easily accessible to the user for future reference.