LG ARNU053TRD4 INSTALLATION MANUAL

INSTALLATION MANUAL

AIR CONDITIONER

<![if ! IE]>

<![endif]>ESPAÑOL FRANÇAIS ENGLISH

Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

Ceiling Cassette - 4Way

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

http://www.lghvac.com

P/NO : MFL42803130

 

 

 

 

 

 

 

 

 

 

 

 

www.lg.com

Rev.07_040318

 

 

 

 

 

 

Copyright © 2013 - 2018 LG Electronics Inc. All Rights Reserved.

IMPORTANT!

Please read this instruction sheet completely before installing the product.

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

WARNING

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Caution: Improper installation, adjustment, alteration, service or maintenance can void the warranty.The weight of the condensing unit requires caution and proper handling procedures when lifting or moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.

Safety Precautions

Always wear safety eye wear and work gloves when installing equipment.

Never assume electrical power is disconnected. Check with meter and equipment.

Keep hands out of fan areas when power is connected to equipment.

R-410A causes frostbite burns.

R-410A is toxic when burned.

Note to installing dealer: The Owners Instructions and Warranty are to be given to the owner or prominently displayed near the indoor Furnace/Air Handler Unit.

WARNING

When wiring:

Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician should attempt to wire this system.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When transporting:

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger.

When installing...

... in a wall: Make sure the wall is strong enough to hold the unit's weight. It may be necessary to construct a strong wood or metal frame to provide added support.

... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to wall and floors.

... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When connecting refrigerant tubing:

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Check carefully for leaks before starting the test run.

When servicing:

Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

2 Indoor Unit

TABLE OF CONTENTS

4 INSTALLATION PARTS

5SAFETY PRECAUTIONS

7INSTALLATION

7Selection of the best location

8 Ceiling dimension and hanging bolt location

9Wiring Connection

12Plumbing materials and storage methods

13Flaring Work

14Installation of Decoration Panel

15Drain Piping

16Ceiling Height Selection

17DIP Switch Setting

18Group Control Setting

22 Model Designation

22 Airborne Noise Emission

22 Limiting concentration

Table of contents

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 3

LG ARNU053TRD4 INSTALLATION MANUAL

Installation Parts

Installation Parts

Anti-bacteria filter

Air

Intake

Air Outlet

Wired Remote Controller(Accessory)

Installation Tool

Name

Drain hose

Clamp metal

Washer for

Plastic band

Insulation for

Conduit

(Other)

hanging backet

fitting

mounting plate

 

 

 

 

 

Quantity

1 EA

2 EA

8 EA

4 EA

1 SET

1 EA

• Paper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pattern for

 

 

 

 

 

 

 

installation

 

 

 

 

 

 

 

• Owner's

Shape

 

 

 

 

 

 

manual

 

 

 

 

for gas pipe

 

• Installation

 

 

 

 

 

 

 

manual

 

 

 

 

 

for liquid pipe

 

 

• Screws for fixing panels are attached to decoration panel.

4 Indoor Unit

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

νBe sure to read before installing the air conditioner.

νBe sure to observe the cautions specified here as they include important items related to safety.

νIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

ν Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

-There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

-Do not disassemble or repair the product. There is risk of fire or electric shock.

Always ground the product.

-There is risk of fire or electric shock.

Install the panel and the cover of control box securely.

-There is risk of fire or electric shock.

Always install a dedicated circuit and breaker.

-Improper wiring or installation may cause fire or electric shock.

Use the correctly rated breaker or fuse.

-There is risk of fire or electric shock.

Do not modify or extend the power cable.

-There is risk of fire or electric shock.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

-Moisture may condense and wet or damage furniture.

Be cautious when unpacking and installing the product.

-Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 5

Safety Precautions

For installation, always contact the dealer or an Authorized Service Center.

-There is risk of fire, electric shock, explosion, or injury.

Do not install the product on a defective installation stand.

-It may cause injury, accident, or damage to the product.

Be sure the installation area does not deteriorate with age.

-If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and Do not use Flammable gases.

Otherwise, it may cause fire or explosion.

-There is the risk of death, injury, fire or explosion.

Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover are removed or opened.

-Otherwise, it may cause fire, electric shock, explosion or death.

Operation

Do not store or use flammable gas or combustibles near the product. - There is risk of fire or failure of product.

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

-Low refrigerant levels may cause failure of product.

Install the drain hose to ensure that water is drained away properly.

-A bad connection may cause water leakage.

Keep level even when installing the product.

-To avoid vibration or water leakage.

Use two or more people to lift and transport the product.

-Avoid personal injury.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

-It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

6 Indoor Unit

Installation

Installation

Read completely, then follow step by step.

Selection of the best location

• There should not be any heat source or steam near the unit.

 

• There should not be any obstacles to the air circulation.

 

• A place where air circulation in the room will be good.

 

 

• A place where drainage can be easily obtained.

 

 

 

• A place where noise prevention is taken into consideration.

 

• Do not install the unit near the door way.

 

 

 

 

• Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

 

• The indoor unit must have the maintenance space.

 

 

 

* Case of the size

 

 

 

 

 

[Width : 570(22-7/16)] x [Depth : 570(22-7/16)]

 

 

 

 

 

30(1-3/16)

Ceiling

 

<![if ! IE]>

<![endif]>10(13/32)

<![if ! IE]>

<![endif]>ormore

 

±3(1/8)

 

 

Ceiling Board

 

* Case of the size

Ceiling Board

 

 

 

<![if ! IE]>

<![endif]>less

 

 

 

 

[Width : 840(33-1/16)] x [Depth : 840(33-1/16)]

 

 

 

 

 

 

<![if ! IE]>

<![endif]>000(39-3/8) moreor

 

 

<![if ! IE]>

<![endif]>) or

 

500(19-11/16)

 

500(19-11/16)

<![if ! IE]>

<![endif]>300(11-13/16

 

or more

 

 

or more

 

15(19/32) ±3(1/8)

 

<![if ! IE]>

<![endif]>1

 

<![if ! IE]>

<![endif]>“A”

 

 

 

 

 

 

“A”

 

 

 

 

 

Below 36 kBtu/h(10.6 kW) At least 1 800(70-7/8),

 

 

 

Floor

 

3 600(141-23/32) or less

 

 

 

Unit:mm(inch)

Over 36 kBtu/h(10.6 kW) At least 1 800(70-7/8),

 

 

 

 

4 200(165-11/32) or less

 

 

 

 

 

CAUTION : In case that the unit is installed near the sea, the installation parts may be corroded by salt. The installation parts (and the unit) should be taken appropriate anti-corrosion measures.

CAUTION : Don't install additional ventilation products on the cabinet of cassette type air conditioner.

η Please use an annexed sheet or the corrugated

η When using the bottom sheet, please use it

cardboard on the bottom of packing as installa-

after separating the installation sheet from

tion sheet.

 

packing of the product floor by using a knife etc

 

 

as a picture below.

 

Or

 

Annexed sheet

Packing corrugated

 

 

cardboard on the

 

 

bottom

 

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 7

Loading...
+ 16 hidden pages