Lenovo 7309BAX, 7159-HCP User Manual

0 (0)

Click here to check for updates

Lenovo RackSwitch G7028

Product Guide

The Lenovo RackSwitch™ G7028 is an inexpensive, entry-level Layer 2 1/10 Gb Ethernet switch that is designed for the data center. Data center customers continue to deploy applications by using 1 GbE networking switches while 10 GbE continues to grow for customer solutions that require greater I/O bandwidth. The RackSwitch G7028 is an ideal solution for data center customers who need an economical 1 Gb and 10 Gb connectivity solution.

The RackSwitch G7028 (see the following figure) is a top-of-rack data center switch that delivers excellent non-blocking, wire speed performance at an attractive price point. It supports 24x 10/100/1000BASE-T RJ-45 ports and four 10 Gigabit Ethernet SFP+ ports standard, while typically using only 45 watts of power. The RackSwitch G7028 is also designed with rear-to-front airflow, which allows for flexible mounting of the switch in a rack cabinet and provides convenient cable management and significant savings in cooling costs.

Figure 1. Lenovo RackSwitch G7028

Did you know?

The RackSwitch G7028 is designed with non-blocking, line-rate throughput.

The RackSwitch G7028 supports an optional external redundant power supply with the Lenovo RackSwitch G7000 Redundant Power Supply option.

The RackSwitch G7028 is designed specifically for the data center environment with server-matching airflow, cost-effective Layer 2 switching and ease of configuration management.

Networking Operating System software features deliver seamless, standards-based integration into upstream switches.

Lenovo RackSwitch G7028

1

Key features

The RackSwitch G7028 switch is considered particularly suited for the following customers:

Customers who want to use GbE in their infrastructure (servers and networking) Customers who are implementing a virtualized environment and require multiple GbE ports Customers who require investment protection for 10 GbE ports

Customers who want to reduce total cost of ownership (TCO) and improve performance while maintaining high levels of availability and security

Customers who want to avoid or minimize oversubscription, which can result in congestion and loss of performance

Customers who want to implement a converged infrastructure with NAS or iSCSI

The G7028 switch offers the following key features and benefits:

Increases network performance

The RackSwitch G7028 provides up to 128 Gbps of switching throughput, supports four SFP+ 10 Gb uplink ports for zero oversubscription, and has a port to port latency of 3.3 microseconds.

Lower power and exceptional cooling

The RackSwitch G7028 typically uses only 45 W of power. Unlike side-cooled switches, which can cause heat recirculation and reliability concerns, the RackSwitch G7028 switch's rear-to-front cooling design reduces data center air conditioning costs by matching airflow to the server’s configuration in the rack.

Fault tolerance

These switches learn alternative paths automatically and perform faster convergence if there is a link, switch, or power failure. The switch uses technologies, such as Virtual Link Aggregation, L2 trunk failover, and Hot Links.

Seamless interoperability

RackSwitch switches interoperate seamlessly with other vendors' upstream switches.

The RackSwitch G7028 supports an optional external redundant power supply with the Lenovo RackSwitch G7000 Redundant Power Supply (RPS) option that is shown in the following figure.

Figure 2. Lenovo RackSwitch G7000 Redundant Power Supply

The G7000 RPS option has the following features:

Form factor: 1U rack mount

Power connections: Four DC connections in the rear of the rack to connect to the G7028 and G7052 switches; one AC inlet connector to connect to the power source (rack PDU or wall connector)

Airflow: Rear-to-front cooling

Power: Approximately 55 - 276 W, which varies depending upon operating conditions and number and types of switches connected

Rack installation: Generic rack-mount kit (2-post); optional flexible 4-post mounting option for the server rack and the communications rack

LEDs: System LEDs to indicate status

Lenovo RackSwitch G7028

2

Lenovo 7309BAX, 7159-HCP User Manual

Components and connectors

The front panel of the RackSwitch G7028 is shown in the following figure.

Figure 3. Front panel of the RackSwitch G7028

The front panel of the G7028 contains the following components:

LEDs that display the status of the switch module and the network.

One RJ-45 RS-232 console port that provides another means to configure the switch module. A total of 24 1000BASE-T Ethernet ports for 10/100/1000 Mbps connections.

Four SFP+ ports to attach SFP/SFP+ transceivers for 1 Gb or 10 Gb connections or DAC cables for 10 Gb Ethernet connections.

One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.

The rear panel of the RackSwitch G7028 is shown in the following figure.

Figure 4. Rear panel of the RackSwitch G7028

The rear panel of the G7028 contains the following components:

One AC power connector (IEC 320-C14)

Three fans with N+1 redundancy

One DC power connector for power supply redundancy

The rear panel of the RackSwitch G7000 RPS option is shown in the following figure.

Figure 5. Rear panel of the RackSwitch G7000 RPS option

The rear panel of the G7000 RPS option contains the following components:

One AC power connector (IEC-320 C14)

Four DC power connectors

Lenovo RackSwitch G7028

3

System specifications

The following table lists the RackSwitch G7028 system specifications.

Table 1. System specifications

Component

Specification

Form factor

1U rack mount

Ports

24x Gigabit Ethernet (GbE) RJ-45 fixed ports

 

4x SFP/SFP+ ports

SFP/SFP+ media

10 Gb Ethernet SFP+:

types

10 GbE short-range (SR) SFP+ transceivers

 

10 GbE long-range (LR) SFP+ transceivers

 

10 GbE RJ-45 SFP+ transceivers

 

10 GbE SFP+ active optical cables (AOCs)

 

10 GbE SFP+ direct attach copper (DAC) cables

 

1/10 Gb Ethernet SFP+:

 

1/10 GbE SX/SR SFP+ transceivers

 

1 Gb Ethernet SFP:

 

1 GbE short-wavelength (SX) SFP transceivers

 

1 GbE long-wavelength (LX) SFP transceivers

 

1 GbE RJ-45 SFP transceivers

Port speeds

1 GbE RJ-45 fixed ports: 10/100/1000 Mbps autosensing

 

10 GbE SFP+ transceivers, DAC cables and AOCs: 10 Gbps

 

1/10 GbE SFP+ transceivers: 1 Gbps or 10 Gbps

 

1 GbE SFP transceivers: 1 Gbps

Switching method

Cut-through.

Data traffic types

Unicast, multicast, broadcast.

Software features

Lenovo Networking OS:

 

Layer 2 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol

 

(STP), link aggregation (trunk) groups (LAGs), virtual LAGs (vLAGs), Hot Links, Layer 2 failover,

 

quality of service (QoS), IP v4 management, IP v6 management.

Performance

Non-blocking architecture with wire-speed forwarding of traffic:

 

Up to 128 Gbps aggregated throughput

 

As low as 3.3 microseconds switching latency

 

Up to 96 Million packets per second (Mpps)

 

Up to 12,288-byte jumbo frames

Scalability

MAC address forwarding database entries: 8,000

 

VLANs: 4,095 (512 active VLANs)

 

Per VLAN Rapid Spanning Tree (PVRST) instances: 128

 

Multiple STP (MSTP) instances: 32

 

Link aggregation groups: 16

 

Ports in a link aggregation group: 8

Cooling

Three 2+1 redundant fixed fans. Rear (non-port side) to front (port side) airflow.

Power supply

One fixed 90 W AC (100 - 240 V) power supply (IEC 320-C14 connector). Optional external

 

power supply unit (PSU) is available for redundancy (one PSU with 4x 90 W DC output for up

 

to four G7028 or G7052 switches).

Hot-swap parts

SFP/SFP+ transceivers, SFP+ DAC cables.

Management

1x 10/100/1000 Mb Ethernet port (RJ-45); 1x RS-232 port (RJ-45); 1x USB port (for additional

ports

firmware, log, and configuration files storage).

Lenovo RackSwitch G7028

4

Component

Specification

Management

Industry standard command line interface (isCLI); SNMP v1 and v3. Optional Lenovo XClarity

interfaces

for discovery, inventory, monitoring and events.

Security features

Secure Shell (SSH); Secure Copy (SCP); Secure FTP (sFTP); user level security, Role-based

 

Access Control (RBAC); LDAP/LDAPS, RADIUS, and TACACS+ authentication; access

 

control lists (ACLs); port-based network access control (IEEE 802.1x).

Hardware

Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day

warranty

terms. Optional warranty service upgrades are available through Lenovo: 24x7 coverage, 2-

 

hour or 4-hour response time, 1-year or 2-year warranty extensions, 1-year or 3-year Remote

 

Technical Support (RTS).

Software

Three-year software support and subscription is included in the base warranty. Optional 1-

maintenance

year and 2-year warranty extensions include software support and subscription.

Mean Time

128,407 hours with ambient operating temperature of 40° C

Between Failures

 

Dimensions

Height: 44 mm (1.7 in.); width: 439 mm (17.3 in.); depth: 382 mm (15.0 in.)

Weight

5.3 kg (11.7 lb).

Models

The following table lists the G7028 switch models.

Table 2. G7028 switch models

Description

Part

Machine

Feature

number

Type-Model

code

Lenovo RackSwitch G7028 (Rear-to-Front)

7159BAX

7159-HCP

AT09

The part number for the G7028 switch includes the following items:

One Lenovo RackSwitch G7028

Generic Rack Mount Kit (2-post)

Power Cord Retention Clip

Console Cable Kit:

RJ-45 (plug) to RJ-45 (plug) cable (1 m)

Mini-USB to RJ-45 (jack) cable (0.2 m)

DB-9 to RJ-45 (jack) adapter

Warranty Flyer

Important Notices Flyer

Documentation CD-ROM

Configuration notes:

Power cables are not included and must be ordered together with the switch (see "Power supplies and cables" for details).

SFP/SFP+ transceivers and cables are not included and should be ordered together with the switch, if required (see "Transceivers and cables" for details).

Lenovo RackSwitch G7028

5

Transceivers and cables

With the flexibility of the G7028 switch, customers can choose the following connectivity technologies:

For 1 GbE links, customers can use RJ-45 UTP cables up to 100 meters. Customers that need longer distances can use the 1000BASE-SX transceivers in the SFP/SFP+ ports, which can drive distances up to 220 meters with 62.5 µ multi-mode fiber (OM1) and up to 550 meters with 50 µ multi-mode fiber (OM2), or the 1000BASE-LX transceivers that support distances up to 10 kilometers with single-mode fiber (1310 nm).

For 10 GbE links (supported on SFP+ ports), customers can use direct-attached copper (DAC) SFP+ cables for in-rack cabling for distances up to 7 meters or SFP+ active optical cables (AOCs) for distances up to 20 meters. These cables have SFP+ connectors on each end, and they do not need separate transceivers. For distances up to 30 meters, the 10GBASE-T SFP+ transceiver can be used with Category 6a or 7 RJ-45 UTP cables.

For longer distances, the 10GBASE-SR transceiver can support distances up to 300 meters over OM3 multimode fiber or up to 400 meters over OM4 multimode fiber. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single mode fiber.

The supported SFP/SFP+ and DAC cable options are listed in the following table.

Table 3. Supported SFP/SFP+ transceivers and DAC cables

 

Part

Feature

Maximum

Description

quantity

number

code

supported

SFP transceivers - 1 GbE

 

 

 

Lenovo 1000BASE-T (RJ-45) SFP Transceiver (no 10/100 Mbps support)

00FE333

A5DL

4

Lenovo 1000BASE-SX SFP Transceiver

81Y1622

3269

4

Lenovo 1000BASE-LX SFP Transceiver

90Y9424

A1PN

4

SFP+ transceivers - 10 GbE

 

 

 

Lenovo Dual Rate 1/10Gb SX/SR SFP+ Transceiver

00MY034

ATTJ

4

Lenovo 10GBASE-SR SFP+ Transceiver

46C3447

5053

4

Lenovo 10GBASE-LR SFP+ Transceiver

90Y9412

A1PM

4

Lenovo 10GBASE-T SFP+ Transceiver

7G17A03130

AVV1

4

Optical cables for 1 GbE SFP SX and 10 GbE SFP+ SR transceivers

 

 

 

Lenovo 0.5m LC-LC OM3 MMF Cable

00MN499

ASR5

4

Lenovo 1m LC-LC OM3 MMF Cable

00MN502

ASR6

4

Lenovo 3m LC-LC OM3 MMF Cable

00MN505

ASR7

4

Lenovo 5m LC-LC OM3 MMF Cable

00MN508

ASR8

4

Lenovo 10m LC-LC OM3 MMF Cable

00MN511

ASR9

4

Lenovo 15m LC-LC OM3 MMF Cable

00MN514

ASRA

4

Lenovo 25m LC-LC OM3 MMF Cable

00MN517

ASRB

4

Lenovo 30m LC-LC OM3 MMF Cable

00MN520

ASRC

4

SFP+ active optical cables - 10 GbE

 

 

 

Lenovo 1m SFP+ to SFP+ Active Optical Cable

00YL634

ATYX

4

Lenovo 3m SFP+ to SFP+ Active Optical Cable

00YL637

ATYY

4

Lenovo 5m SFP+ to SFP+ Active Optical Cable

00YL640

ATYZ

4

Lenovo 7m SFP+ to SFP+ Active Optical Cable

00YL643

ATZ0

4

Lenovo RackSwitch G7028

6

 

Part

Feature

Maximum

Description

quantity

number

code

supported

Lenovo 15m SFP+ to SFP+ Active Optical Cable

00YL646

ATZ1

4

Lenovo 20m SFP+ to SFP+ Active Optical Cable

00YL649

ATZ2

4

SFP+ passive direct-attach cables - 10 GbE

 

 

 

Lenovo 0.5m Passive SFP+ DAC Cable

00D6288

A3RG

4

Lenovo 1m Passive SFP+ DAC Cable

90Y9427

A1PH

4

Lenovo 1.5m Passive SFP+ DAC Cable

00AY764

A51N

4

Lenovo 2m Passive SFP+ DAC Cable

00AY765

A51P

4

Lenovo 3m Passive SFP+ DAC Cable

90Y9430

A1PJ

4

Lenovo 5m Passive SFP+ DAC Cable

90Y9433

A1PK

4

Lenovo 7m Passive SFP+ DAC Cable

00D6151

A3RH

4

SFP+ active direct-attach cables - 10 GbE

 

 

 

Lenovo 1m Active DAC SFP+ Cable

00VX111

AT2R

4

Lenovo 3m Active DAC SFP+ Cable

00VX114

AT2S

4

Lenovo 5m Active DAC SFP+ Cable

00VX117

AT2T

4

Spare console cables

 

 

 

Console Cable Kit Spare (RJ45/DB9)

90Y9462

A2MG

1

The network cables that can be used with the switch are listed in the following table.

Table 4. G7028 network cabling requirements

Transceiver

Standard

Cable

Connector

10 Gb Ethernet

 

 

 

10Gb SR SFP+ (46C3447)

10GBASE-SR

Up to 30 m with fiber optic cables supplied by Lenovo

LC

1/10Gb SFP+ (00MY034)

 

(see Table 3); up to 300 m with OM3 multimode fiber or

 

 

 

up to 400 m with OM4 multimode fiber

 

10Gb LR SFP+ (90Y9412)

10GBASE-LR

1310 nm single-mode fiber cable up to 10 km

LC

10Gb RJ-45 SFP+

10GBASE-T

UTP Category 6a or 7 up to 30 meters

RJ-45

(7G17A03130)

 

 

 

Active optical cable

10GBASE-SR

SFP+ active optical cables up to 20 m (see Table 3)

SFP+

Direct attach copper cable

10GSFP+Cu

SFP+ DAC cables up to 7 m (see Table 3)

SFP+

1 Gb Ethernet

 

 

 

RJ-45 ports (fixed)

1000BASE-T

UTP Category 5, 5E, and 6 up to 100 meters

RJ-45

1Gb RJ-45 SFP (00FE333)

1000BASE-T

UTP Category 5, 5E, and 6 up to 100 meters

RJ-45

1Gb SX SFP (81Y1622)

1000BASE-SX

Up to 30 m with fiber optic cables supplied by Lenovo

LC

1/10Gb SFP+ (00MY034)

 

(see Table 3); 850 nm multimode fiber cable 50 µ (OM2)

 

 

 

up to 550 m or 62.5 µ (OM1) up to 220 m

 

1Gb LX SFP (90Y9424)

1000BASE-LX

1310 nm single-mode fiber cable up to 10 km

LC

Management ports

 

 

 

Ethernet management port

1000BASE-T

UTP Category 5, 5E, and 6 up to 100 meters

RJ-45

RS-232 serial console port

RS-232

DB-9/RJ-45-to-RJ-45 (comes with the switch)

RJ-45

Lenovo RackSwitch G7028

7

Loading...