Leica DMI Series, DMI3000 B, DMI4000 B, DMI6000 B Instructions Manual

Leica DMI3000B, DMI4000B, DMI6000B
Instructions · Bedienungsanleitung · Mode d’emploi
Revision 1.1, published 30. August 2012 by:
Revision 1.1, herausgegeben 30. August 2012 von:
Révision 1.1, publiée le 30 août 2012 par :
Leica Microsystems CMS GmbH
Ernst-Leitz-Straße 17-37
http://www.leica-microsystems.com
Responsible for contents:
Verantwortlich für den Inhalt:
Responsable du contenu rédactionnel :
Marketing CMS, Product Management
Marketing CMS, Produktmanagement
Marketing CMS , Product Management
Leica DMI3000B, DMI4000B, DMI6000B
Instructions
Copyrights
Copyrights
All rights to this documentation are held by Lei­ca Microsystems CMS GmbH. Reproduction of text or illustrations (in whole or in part) by print, photocopy, microfi lm or other method (including electronic systems) is not allowed without ex­press written permission from Leica Microsys­tems CMS GmbH.
The term „Windows“ may appear in the following text without further identifi cation. It is, however, a registered trademark of Microsoft Corpora­tion. The names of companies and products used herein may be trademarks of their respective owners.
The instructions contained in the following docu­mentation refl ect state-of-the-art technology standards. We have compiled the texts and illus­trations as accurately as possible. Still, we are always grateful for comments and suggestions regarding potential mistakes within this docu­mentation.
The information in this manual is subject to modi­fi cation at any time and without notifi cation.
4
Contents
Contents
1. Important Notes about this Manual ............7
1.1 Text symbols, pictograms and
their meanings .................................................7
2. Intended Purpose of the Microscope ......... 9
3. Safety Notes ..................................................10
3.1 General Safety Notes....................................10
3.2 Electrical Safety.............................................11
3.3 Transport and storage ..................................13
3.4 Safety Instructions
for Handling the Light Sources ...................13
3.5 Notes on handling laser devices ................13
3.6 Notes on handling immersion oil ................13
3.7 Safety Instructions
for Handling Acids and Bases .....................14
3.8 Disposal...........................................................14
3.9 Type labels ......................................................14
4. Overview of the Leica DMI Series ............15
5. Unpacking the Microscope .......................28
6. Assembling the Microscope ......................31
6.1 Assembly Tools ..............................................31
6.2 Installation of the Transmitted Light
Illumination Carrier (TL) ................................32
6.3 Installation of the DIC Module ...................33
and DIC Objective Prisms.............................33
6.4 Installation of Specimen Stages .................34
6.5 Installation of Condensers ...........................39
6.6 Installation of Eyepieces ..............................44
6.7 Installation of Objectives..............................44
6.8 Installation of Filters
in the Illumination Arm..................................45
6.9 Installing the transmitted Light Lamp
Housing ...........................................................45
6.10 Installation and Replacement of the transmitted Light Lamps:
107 or 107/2 Lamp Housing...........................46
6.11 Installing the Lamp Housing Mount and
Mirror Housing (Leica DMI4000 B and
DMI6000 B) .....................................................47
6.12 Installation and Replacement
of Incident Light Lamps ................................49
6.13 Equipping the Incident Light Turret Disk ....53
6.14 Inserting the Front Module Slider ...............56
6.15 Installation of the Polarizer
and Analyzer...................................................56
6.16 Optional Accessories....................................58
6.17 Connection to the Electronics Box CTR4000, CTR5000, CTR5500, CTR6000, CTR6500,
CTR7000, CTR6500 HS, CTR7000 HS ............59
6.18 Connection to the Computer ........................60
6.19 Connection to the Power Supply ................60
7. Start-up ..........................................................61
7.1 Functional Principle (Leica DMI4000 B
and Leica DMI6000 B) ...................................61
7.2 Switching on the Microscope .....................65
7.3 The LeicaDisplay
(Leica DMI4000 B and DMI6000 B) .............66
7.4 The Function Buttons on the Stand ............67
7.5 The SmartMove Remote Control Module ..70
7.6 Illumination .....................................................70
7.6.1 Transmitted light ................................70
7.6.2 Incident Light - Fluorescence .........73
7.7 Checking Phase Contrast Rings ..................74
7.8 Checking modulation contrast slit
diaphragms .....................................................78
7.9 Setting the Motorized Polarizer ..................78
7.10 Adjusting the Light Sources ........................79
5
Contents
8. Operation ....................................................... 82
8.1 Switching on...................................................82
8.2 Contrast Methods ..........................................84
8.2.1 Bright Field (TL) .................................84
8.2.2 Phase Contrast (TL) ........................86
8.2.3 Dark Field (TL) ....................................87
8.2.4 Polarization (TL) ................................88
8.2.5 Differential Interference
Contrast (TL) .....................................89
8.2.6 Integrated Phase Contrast (TL) ......90
8.2.7 Integrated Modulation
Contrast (TL) ......................................91
8.3 Fluorescence..................................................92
8.4 Combination Methods .................................94
8.5 Focusing ..........................................................95
8.6 Tubes ..............................................................97
8.7 Port selection ................................................97
8.8 Eyepieces........................................................98
8.9 Objectives .......................................................99
8.10 Stages and Object Displacement .............102
8.11 Magnifi cation Changer ...............................103
8.12 Light sources ................................................104
8.13 Aperture and Field Diaphragm .................105
9. Trouble Shooting ........................................106
10. Care of the Microscope ............................110
10.1 Dust Cover ....................................................110
10.2 Cleaning ........................................................110
10.3 Handling Acids and Bases .........................111
11. Major Consumable and Replacement
Parts ............................................................ 112
12. Dimensions..................................................113
13. Abbreviations and Pictograms ................ 114
14. Index ............................................................116
15. EU Declaration of Conformity ..................118
6
1. Important Notes about this Manual
1. Important Notes about this Manual
Caution!
This operating manual is an essential com­ponent of the microscope, and must be read carefully before the microscope is assem­bled, put into operation or used.
1.1 Text symbols, pictograms and their mean­ings
This operating manual contains important in­structions and information for the operational safety and maintenance of the microscope and accessories. It must therefore be kept safely for future reference. A separate manual is available on CD-ROM cov­ering the operation of the Leica Application Suite (LAS).
(1.2)
p. 20
*
IVD
MM/YYYY
Numbers in parentheses, such as „(1.2)“, corre­spond to illustrations (in the example, Figure 1, Item 2).
Numbers with pointer arrows (for example p. 20), point to a certain page of this manual.
Explanatory note.
Item not contained in all confi gurations.
Notes on the disposal of the microscope, ac­cessories and consumable materials.
Device for in vitro diagnostics.
IVD manufacturing date, example 11 / 2011 for November 2011.
7
1. Important Notes about this Manual
!
Caution! Special safety instructions within this manual are indicated with the triangle symbol shown here, and have a gray background.
Caution! The microscope and accessories can be damaged when operated incorrectly.
Warning of hot surface!
Ground/Earth terminal!
Caution - High voltage! Risk of electrical shock!!
Warning: Before opening disconnect mains.
China RoHS 50 years EFUP (Environmentally friendly use period)
8
2. Intended Purpose of the Microscope
2. Intended Purpose of the Microscope
The Leica DMI Series microscopes covered in this manual are designed for biological, routine, and research applications. This includes the ex­amination of samples taken from the human body in order to provide information on physiological or pathological states or congenital abnormali­ties; to determine the safety and compatibility with potential recipients; or to monitor therapeu­tic measures.
The Leica DMI Series is an additional develop­ment of Leica’s proven inverted research mi­croscopes, designed for cellular and tissue examination, micromanipulation and microinjec­tion techniques, microdissection, and confocal microscopy. The Leica DMI Series is suitable for universal deployment. All contrast methods such as dark fi eld, bright fi eld, phase contrast, DIC, fl uorescence, and modulation contrast are integral to the microscope and can be adapted or changed quickly and easily. Variable illumi­nation and imaging beam paths, as well as HCS optics, modular accessories, and a comprehen­sive range of peripherals complement the Leica Microsystems inverted research stand.
IVD
The above-named microscopes comply with the Council Directive 98/79/EEC concerning in vitro diagnostics.
Caution!
The manufacturer assumes no liability for damage caused by, or any risks arising from, using the microscopes for purposes other than those for which they are intended or not using them within the specifi cations of Leica Microsystems CMS GmbH. In such cases the declaration of conformity shall cease to be valid.
Caution!
These (IVD) devices are not intended for use in the patient environment defi ned by DIN VDE 0100-710. Neither are they intended for combining with medical instruments accord­ing to EN 60601-1. If a microscope is electri­cally connected to a medical instrument according to EN 60601-1, the requirements defi ned in EN 60601-1-1 shall apply. Not suitable for examining potentially infec­tious specimens. Only trained personnel may operate this type of device.
9
9
3. Safety Notes
3. Safety Notes
3.1 General Safety Notes
These safety class 1 instruments were built and tested in accordance with the harmonized standards EN 61010-1:2002-08, EN 61326-1:2006, IEC 61010-1:2001-02, UL 61010-1:2004, Safety regulations for electrical measuring, con­trol, and laboratory devices and EN 61010-2-101:2002-11, IEC 61010-2-101:2002-01 Safety regulations for electrical measuring, con­trol, and laboratory devices, part 2 special re­quirements concerning in vitro diagnostics (IVD) medical instruments.
Caution!
In order to maintain this condition and to en­sure safe operation, the user must follow the instructions and warnings contained in this operating manual.
Caution!
The devices and accessories described in this operating manual have been tested for safety and potential hazards. The responsible Leica affi liate or the main plant in Wetzlar must be consulted whenever the device is altered, modifi ed or used in con­junction with non-Leica components that are outside of the scope of this manual.
Unauthorized alterations to the device or noncompliant use shall void all rights to any warranty claims and product liability!
10
10
3. Safety Notes
3.2 Electrical Safety
General Specifi cations
Leica CTR4000, CTR5000, CTR5500, CTR6000, CTR6500, CTR7000, CTR6500 HS, CTR7000 HS Electronics Boxes
For indoor use only Supply voltage: Frequency: Power input: Fuses:
.
100–240 V AC 50/60 Hz max. 290 W T6.3 A
(IEC 60127-2/3) Ambient temperature: Relative humidity:
Over voltage category: Pollution degree:
15–35°C
max. 80% to 30°C
non-condensing
II
2
Microscope
For indoor use only. Supply voltage: Frequency: Power input: Fuses: Ambient temperature: Relative humidity:
100–240 V AC 50/60 Hz See CTR4000–7000 HS See CTR4000–7000 HS 15–35°C max. 80% to 30°C
non-condensing Over voltage category: Pollution degree:
II
2
ebq 100 supply unit*
For indoor use only. Supply voltage: Frequency: Power input: Fuses: Ambient temperature: Relative humidity:
100–240 V AC 50/60 Hz max. 155 W 2xT2A (IEC 127)10– 36°C max. 80% to 30°C
non-condensing Over voltage category: Pollution degree:
II
2 (see enclosed manual)
Leica EL6000*
For indoor use only. Supply voltage: Frequency: Power input: Fuses:
100–240 V AC 50/60 Hz max. 200 W 5x20, 2.5 A, slow,
breaking capacity H Ambient temperature: Relative humidity:
0°–40°C
10–90%
non-condensing Overvoltage category: Pollution degree:
II
2 (see enclosed manual)
11
3. Safety Notes
Caution!
Power plugs may only be plugged into an out­let equipped with a grounding contact.
Do not interfere with the grounding function by using an extension cord without a ground wire. Any interruption of the ground wire in­side or outside of the device, or release of the ground wire connection, can cause the device to become hazardous. Intentional ground interruption is not permitted!
Caution!
Peripheral devices with their own or sepa­rate power supplies that are connected to the microscope can have the same protec­tive conductor potential by connecting them to the ground screw on the back of the Leica CTR4000, CTR6000, CTR6500 and CTR7000 electronics boxes. For connections without a ground connector, Leica Service must be consulted.
Caution!
The microscope’s electrical accessory com­ponents are not protected against water. Wa­ter can cause electric shock.
Caution!
Protect the microscope from excessive tem­perature fl uctuations. Such fl uctuations can lead to the accumulation of condensation, which can damage the electrical and optical components. Ambient temperature: 15–35°C.
Caution!
Before exchanging the fuses or lamps, be ab­solutely certain to switch off the main power switch and remove the power cable.
Caution!
Never use any fuses as replacements other than those of the types and the current rat­ings listed here. Using patched fuses or bridging the fuse holder is not permitted. The use of incorrect fuses may result in a fi re haz­ard.
12
Caution!
Per defi nition, the connection between power supply cable and appliance inlet is the power separator of this device. Thus, the user is responsible for suffi cient clearance and accessibility of this area at all times.
Caution!
Do not use the microscope in altitudes ex­ceeding 2000 m ASL/NL.
3.3 Transport and storage
Caution!
Fully equipped, the microscope weighs more than 18 kg. For transportation, the user has to take care of the corresponding actions. See also p. 30.
3. Safety Notes
Caution!
Lamps and lamp housings may be hot! They must be placed at least 10 cm away from the wall and away from fl ammable sub­stances. Particulary, supply and data lines must not encounter lamp housings!
Caution!
Transport and storage in a range of -25°C –+70°C and at a humidity not exceeding 80% (non-condensing).
3.4 Safety Instructions for Handling the Light Sources
Caution!
Light sources pose a potential irradiation risk (glare, UV-radiation, IR-radiation). Therefore, lamps have to be operated in closed hous­ings and only after being mounted. Never look directly into the beam path (blind­ing hazard).
Connect the light guide to the microscope fi rst to prevent exposing the user to the high­energy light output of the Leica EL6000 com­pact light source. Never look directly into the light emitted by the light guide.
3.5 Notes on handling laser devices
The microscope is not suitable for coupling laser devices into the camera ports (refer to Chapter
4), as this creates a danger to the user from laser radiation.
For use of the microscope with lasers, Leica Microsystems offers special microscopes with additional safety devices.
For further information, please contact your au­thorized Leica Microsystems representative.
3.6 Notes on handling immersion oil
Caution!
When using immersion oil, take care to avoid skin contact! Ask the supplier for a safety data sheet!
13
3. Safety Notes
3.7 Safety Instructions for Handling Acids and Bases
For examinations using acids or other aggressive chemicals, particular caution must be taken.
Caution!
Be absolutely certain to prevent coming into contact with these chemicals.
3.8 Disposal
To dispose of the product at the end of its service life, please contact Leica Service or Sales.
Please observe national laws and regulations, such as those implementing and enforcing the WEEE EU Directive.
Note!
3.9 Type labels
Type label Leica DMI3000 B
Type label Leica DMI4000 B
Like other electronic devices, the micro­scope, its accessories and consumable ma­terials must not be disposed of as regular household waste.
14
Type label Leica DMI6000 B
4. Overview of the Instruments
4. Overview of the Leica DMI Series
4.1 Specifi cations
Contrast Methods
Transmitted Light Axis
Leica DMI Series
• transmitted light (TL): BF, DF, PH, DIC, Pol
• intermediate pupil: IPH (Integrated phase contrast)
• incident light (IL): Fluo
Leica DMI4000 B and DMI6000 B
• combination (TL/IL): Fluo/DIC, Fluo/PH
Leica DMI Series
• Manual and coded transmitted light illumination arm with inte­grated mechanical tilt mechanism to provide adequate space for specimens and micromanipulators, integrated fi eld dia phragm, fi lter magazine for 2 replaceable fi lters, condenser quick-chang­er Illumination Manager (aperture diaphragm, fi eld diaphragm, light in-
• tensity)
• manual shutter
• lamp housing mount for interchangeable lamp housings.
• with integrated cable channel
Leica DMI4000 B and Leica DMI6000 B
• Motorized or manual/coded transmitted light illumination arm with integrated mechanical tilt mechanism to provide adequate space for specimens and micromanipulators, integrated motor­ized fi eld diaphragm, motorized fi lter magazine for 2 replace able fi lters, condenser quick-changer
• with integrated cable channel
• automatic Illumination Manager
(aperture, fi eld diaphragm, intensity, process switching)
• manual or motorized shutter
• lamp housing mount for interchangeable lamp housings.
• automatic, electronic condenser identifi cation
IMC (integrated modulation contrast)
15
4. Overview of the Instruments
Incident Light Axis
Tube
Leica DMI3000 B
• manual shutter
• lamp housing mount for up to 3 interchangeable light sources
• manual 5-place fi lter turret
• Fluorescence Intensity Manager (FIM) (reduction of incident illumination intensity)
Leica DMI4000 B and Leica DMI6000 B
• automatic Illumination Manager
(aperture, fi eld diaphragm*, intensity, process switching)
• motorized shutter (switching speed < 50 ms)
• lamp housing mount for up to 3 interchangeable light sources
• motorized 6-place fi lter turret
• Fluorescence Intensity Manager (FIM)
(reduction of incident illumination intensity)
• Optional: Interface for structured illumination
• Leica DMI6000 B:
mechanical booster lens for central boosting of fl uorescence or uniform distribution
• motorized Excitation Manager* to monitor fl uorescence emission when using double and triple fi lter cubes
• ultra fast fi lter wheel for 3 excitation wavelengths (switching speed < 50 ms)
Leica DMI Series
• ergonomic with or without camera port at left
• 2 switching positions: 100%VIS and 50%VIS / 50%CAM or
• 2 switching positions: 100%VIS and 0%VIS / 100%CAM
• optional Bertrand lens
• eye spacing adjustment
• height and angle adjustment (30° - 45°)
Magnifi cation Changer
Leica DMI4000 B and Leica DMI6000 B
• motorized
• 3 switching positions
(choice of magnifi cations: 1x; 1.5x; 1.6x or 2.0x)
• effective on all camera ports and eyepieces
or Leica DMI Series
• manual
• 2 switching positions
(choice of magnifi cations: 1x; 1.5x; 1.6x or 2.0x)
• effective on tube port and eyepieces
* not in combination with structured Illumination
16
4. Overview of the Instruments
Objective Turret
Stages
Leica DMI6000 B
• motorized and coded
• 6x for objectives with M25 thread and 45 mm parfocal distance
• for DIC: motorized or manual/coded Wollaston prism carousel
• anti-vibration locking Leica DMI4000 B
• manual and coded
• 6x for objectives with M25 thread and 45 mm parfocal distance
• for DIC: motorized or manual/coded Wollaston prism carousel Leica DMI3000 B
• manual
• 6x for objectives with M25 thread and 45 mm parfocal distance
• for DIC: manual Wollaston prism carousel
Leica DMI Series Fixed regular stages
• Ceramic-coated stage plate (248 mm x 204 mm)
heating stage plate (3°C above room temperature to 60°C)
(248 x 212 mm)
temperature-controlled stage plate (0°C to 60°C) (248 mm x 212 mm)
• fi xed micromanipulation stages
ceramic-coated stage plate (248 mm x 204/122 mm)
heated stage plate (from 3°C above room temperature
to 60°C) (248 mm x 204/122 mm)
temperature-controlled stage plate (0°C to 60°C)
(248 mm x 204/122 mm)
• regular manual and motorized 3-plate cross-stage
positioning range: 83 mm x 127 mm
20 optional inserts (standard, heating, cooling) for a variety
of applications, size of inserts:160 mm x 110 mm (compatible with scanning stages)
• narrow manual and motorized micromanipulation 3-plate cross-stage
positioning range: 40 mm x 40 mm
3 optional inserts for a variety of applications
• Scanning stage 120 x 100 (motors on bottom)
1 mm, 2 mm, 4 mm spindle pitch (higher resolution vs. higher speed)
20 optional inserts (standard, heating, cooling) for a variety
of applications, size of inserts:160 mm x 110 mm
17
4. Overview of the Instruments
Condensers
Z Focus
Leica DMI4000 B and Leica DMI6000 B (identical for Leica DMI3000 B, but manual)
• motorized and coded or manual and coded
• motorized or manual aperture diaphragm
• contrast methods: BF, DF, PH, DIC, Pol, IMC, IPH
• automatic method switching
• condenser turret with 7 positions for contrast methods
• 2 condenser housings (S1-S28 and S40,S70)
• condenser heads: S1/1.4 oil, S1/0.9 dry, S23/0.53, S28/0.55
• condenser heads can be swung out
• condenser S40/S70 with additional lens for low magnifi cations
• all condensers suitable for magnifi cations from 1.25x to 100x
• with or without motorized or manual polarizer
• with or without motorized or coded Wollaston prism disk
Leica DMI6000 B
• motorized and coded
• 9 mm travel (1 mm below, 8 mm above the stage)
• maximum travel speed: 5 mm/s
• 5 focus steps: 0.05 μm; 0.1 μm; 0.7 μm; 1.5 μm; 5.0 μm
• electronic focus repositioning
• automatic lowering prior to objective change
• electronic parfocality
• Optional: Adaptive Focus Control (AFC)
Leica DMI3000 B and Leica DMI4000 B
• manual
• 9 mm travel (1 mm below, 8 mm above the stage)
Observation Ports
18
Leica DMI6000 B
• motorized and coded
• left side ports (100%, 80% or 50% transmission)
• left side port dichroic splitting at 680 nm
• right side ports (100%, 80% or 50% transmission)
• bottom port
optional
• top port with 2 switching positions
• 100% to eyepieces
• 50% to eyepieces/ 50% to port
Leica DMI4000 B
left side port, manual (100% or 80% transmission)
4. Overview of the Instruments
Observation Ports
Controls
Electronics Box
Leica DMI3000 B (a manual side port is a standard feature of the Leica DMI3000 B stand)
• manual
• left side port (80% or 100% transmission)
Leica DMI4000 B and Leica DMI6000 B
• 7 fi xed control buttons for illumination and apertures
• 7 variable function buttons behind the focus controls
• 3 fi xed control buttons for focus stops (Leica DMI6000 B only)
• 2 focus hand wheels
• 7 buttons for fl uorescence cubes and shutters
• 4 buttons for magnifi cation changer and ports
• SmartMove: ergonomic remote control module for x,y,z control and four additional variable function buttons
• STP6000
Leica DMI3000 B
• 2 focus hand wheels
• 1 illumination hand wheel
• 2 turning knobs for fi eld diaphragm and FIM adjustment
• 1 On/Off switch
• separate control unit for all motorized and electronic elements of
the microscope such as:
For CTR6500 (HS)/CTR7000 (HS) only
• scanning stages
For CTR6000 only
• motorized 3-plate cross-stages
For CTR6000/7000
• objective turret
• focus
• ports
• magnifi cation changer
• fl uorescence
• condenser
• power supply for SmartMove
For all CTR boxes with
• power supply for 100W halogen lamps
19
4. Overview of the Instruments
Interfaces
Software Tools
Leica DMI4000 B and Leica DMI6000 B
• 2 x RS232C
• 2 x USB
• 4 x external/internal peripherals
• CTR boxes
• SmartMove
• STP6000
Leica DMI4000 B and Leica DMI6000 B
• Leica Application Suite (LAS) for Windows with plug-ins for:
• microscope and camera confi guration
• microscope and camera control
• image acquisition
TM
20
4. Overview of the Instruments
18
17
1
14
19
Fig. 1 Left side, Leica DMI4000 B and DMI6000 B 1 Eyepiece 2 Eyepiece tube 3 Top port 4 Intermediate pupil interface 5 LeicaScreen 6 Light intensity 7 Field diaphragm 8 TL/IL switching 9 Aperture diaphragm 10 Focus wheel (motorized Leica DMI6000 B,
manual (fi ne and coarse) Leica DMI4000 B)
16
2
15
3
4
5
678910111213
11 Variable function buttons 12 Left side port 13 Booster lens
(Leica DMI6000 B fl uorescence microscopes only)
14 Lamp mount (fl uorescence microscopes only) 15 Condenser head 16 Condenser base 17 Field diaphragm 18 Transmitted light lamp housing 19 DIC objective prism disk
21
4. Overview of the Instruments
11
4
5
12 3
Fig. 2 R 1 E-Focus buttons (Leica DMI6000 B only) 2 Focus wheel (motorized Leica DMI6000 B,
manual (fi ne) Leica DMI4000 B)
3 Variable function buttons 4 Opener for drawer (fl uorescence microscopes only) 5 Drawer (fl uorescence microscopes only) 6 Right side port 7 Analyzer slot
ight side Leica DMI4000 B and DMI6000 B
22
67812910
8 Centering window (fl uorescence microscopes only) 9 Field diaphragm centering
(fl uorescence microscopes only) 10
Incident light lamp housing (fl uorescence microscopes
only)
11 Objective turret 12 Stage with attachable mechanical stage
4. Overview of the Instruments
5
4
6
3
2
1
Fig. 3 Front view Leica DMI4000 B and Leica DMI6000 B 1 LeicaScreen 2 Front control panel 3 Port switching 4 Top port 5 Manual transmitted light fi lters 6 Bertrand lens centering
23
4. Overview of the Instruments
Fig. 3a Front control panel 1 Fluorescence cube 2 Shutter 3 100% light to all eyepieces 4 Port selection 5 Magnifi cation selection 6 1x tube lens
2
543
Fig. 3b SmartMove remote control module 1 Travel in x 2 Travel in y 3 Focus 4 Variable function buttons
(pre assigned at factory)
3
11
Fig. 4 General view Leica DMI4000 B and Leica DMI6000 B with SmartMove remote control module
1
2
4
24
4. Overview of the Instruments
16
1
15
14
13
12
2
3
4
Fig. 5a Leica DMI3000 B left view 1 Eyepiece 2 Eyepiece tube 3 Top port 4 Intermediate pupil interface 5 Light intensity 6 Focus wheel 7 Left side port with camera 8 Objective turret
8
91011
9 Filter slider 10 Adjustment FIM 11 Adjustment fi eld diaphragm 12 Drawer (fl uorescence microscopes only) 13 DIC objective prism disk 14 Condenser head 15 Condenser base 16 Integrated 30W transmitted light lamp housing
567
25
4. Overview of the Instruments
8
9
10
7
1
Fig. 5b 1 Focus wheel 2 Analyzer slot 3 Centering window (fl uorescence microscopes only) 4 Port switching 5 On/Off switch 6 Incident light lamp housing (fl uorescence microscopes only) 7 Field diaphragm centering 8 Transmitted light lamp housing 9 Field diaphragm 10 Stage with attachable mechanical stage
Leica DMI3000 B right view
26
2
35
4
6
4. Overview of the Instruments
3
2
4
1
5
Fig. 6 Leica DMI3000 B front view 1 Port switching and Bertrand lens 2 Top port 3 Manual transmitted light fi lters 4 Bertrand lens centering 5 Manual magnifi cation changer
27
5. Unpacking the Microscope
5. Unpacking the Microscope
The microscope is delivered in several packages.
The stand package contains the following com­ponents:
• Stand with integrated incident light axis, objective turret, and tube
• Illumination arm
• Specimen stage
• CD with Leica Application Suite (LAS) software package
• Instructions and list of microscope presets (identifi cation sheet)
The system package contains the microscope‘s accessories:
• Eyepieces
• Objectives
• Condenser
• Lamp housings with accessories
• Assembly tools
• Additional accessories such as fi lter cubes, etc. depending on feature set
The Leica CTR4000, CTR5000, CTR5500, CTR6000, CTR6500, CTR7000, CTR6500 HS, CTR7000 HS electronics box, the SmartMove, STP6000 remote control module,
sories,
the external ebq 100 supply unit and the compact light source Leica EL6000 are provided in separate packages.
movable stages, stage acces-
28
5. Unpacking the Microscope
Please carefully compare the contents of the de­livery to the packing slip, delivery note or invoice. We strongly recommend storing a copy of these documents with the manual to ensure that you have information on the date and scope of deliv­ery handy for subsequent orders or service work. Please ensure that no small parts remain in the packing material. Parts of the packing material are marked by symbols to simplify recycling.
First, carefully remove all components from the transportation and packaging materials.
Caution!
Do not put the instrument into operation in the event of visible damage to the components or packing material.
Note:
If at all possible, avoid touching the lens surfaces of the objectives. If fi ngerprints do appear on the glass surfaces, remove them with a soft leather or linen cloth. Even small traces of fi nger perspi­ration can damage the surfaces in a short time. See the chapter „Care of the Microscope“ p. 110, for additional instructions.
Installation Location
Work with the microscope should be performed in a dust-free room, which is free of oil vapor and other chemical vapor, as well as extreme humid­ity. At the workplace, large temperature fl uc­tuations, direct sunlight, and vibration should be avoided. These may adversely affect measure­ments and long-term observations.
Allowable ambient conditions Temperature 15–35°C Relative humidity maximum 80% up to 30°C non-condensing
Microscopes in warm and warm-damp climatic zones require special care in order to prevent the build up of fungus. See the chapter „Care of the Microscope“ p. 110, for additional instructions.
Caution!
Electrical components must be placed at least 10 cm from the wall and away from fl ammable substances.
Caution!
Caution!
Do not connect the microscope or peripher­als to an AC power source at this time under any circumstances!
When installing the microscope, make sure the power inlet is freely accessible so that the instrument can be quickly disconnected from the mains if necessary.
29
5. Unpacking the Microscope
Transport
For shipping or transporting the microscope and its accessory components, the original packag­ing should be used.
As a precaution to prevent damage from vibra­tions, the following components should be disas­sembled and packaged separately:
• Unscrew the objectives.
• Remove the eyepieces.
• Remove the condenser.
• Remove the specimen stage.
• Remove the transmitted-light arm.
• Remove the lamp housings.
• Remove the lamp housing mount.
• Disassemble the burner of 106 z lamp housing.
Weight
The weight of the microscope depends on the particular equipment. Fully equipped, the microscope weighs more than 18 kg. For transportation, the user has to take care of the corresponding actions.
Caution!
For transporting it is essential to remove all components listed under “Transport”!
• Remove the fi lter cube.
• Remove all moving or loose parts.
30