INSTRUCTION/INSTALLATION SHEET
lyriQ™ Studio Local Source Input
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
1. Introduction
The lyriQ™ Studio Local Source Input, PN AU5008-xx, is part of the lyriQ™
Multi-Room Audio System. It is a component which, when combined with other
lyriQ™ components and your source equipment (receiver, CD player, etc.),
helps create a flexible whole-house audio system that will fill your rooms with
high-quality sound for years to come. Category 5 technology is an innovative
method of providing high quality audio to remote locations with a single 8conductor cable such as Cat 5e. This technology provides many advantages
over other conventional methods of audio distribution such as simple, single
Category 5 wiring scheme and infrared control of system components.
IMPORTANT: Read the manuals that are included with all associated
lyriQ™ Audio products before installation of any single component! If you
are unsure of any of the following installation procedures contact OnQ/Legrand Technical Support @ 1-800-321-2343 option 1 or contact an OnQ/Legrand installer.
2. Description
The lyriQ™ Studio Local Source Input allows the lyriQ™ Multi-Room Audio System
to use “local” source inputs (up to 2 maximum) associated with any one volume
control or audio zone. When used in conjunction with Studio Keypads, the lyriQ™
Studio Local Source Input can be chosen from the Keypad just as main sources
are chosen. It is connected in series with the Keypad by simply connecting a run of
Category 5 cable from a lyriQ™ Distribution Module zone to the “INPUT” RJ45
input jack on the rear of the Studio Local Source Input (see Figure 2), and
connecting the “OUTPUT” RJ45 jack over Category 5 cable to the volume control.
If two Local Sources are used, simply daisy-chain them OUTPUT to INPUT using
the RJ45 jacks (see Figure 3). The Studio Local Source Input senses audio signals
on its front side input RCA jacks. When a line level audio source is sensed (MP3
player, TV, or other), the local audio source can then be heard within the zone.
NOTE: Although Studio Keypads are able to select Studio Local Source Input
#1 or #2 or any Main Source from the keypad and are also able to override an
active local source, an active local source is initially sensed and switched to
automatically.
NOTE: When using an MP3 player as the local source, insure its volume is
turned up past 50% to make sure its output is detected by the lyriQ™ Studio
Local Source Input.
The LED on the front lights green to indicate that the Studio Local Source Input has switched over to the local
audio source and that the source is active. It lights amber to indicate that it has switched over to the local
audio source, but that the source is not active. It lights red to indicate that a main audio source has been
switched through as an override to a connected local audio source regardless whether that main audio source
is present or not. There is also a gain control on the front to allow attenuation/gain of the local audio signal.
There are two potentiometers on the rear which are used to determine the sensitivity of the audio detect
circuit that causes the Studio Local Source Input to switch to a local audio source, and to determine the time
IS-0421 REV. O
AU5008-WH (White)
AU5008-LA (Lt. Almond)
AU5008-TI (Titanium)
AU5008-GB (Gloss Black)
Figure 1
Figure 2
Page 1 of 4
©Copyright 2008 by On-Q/Legrand All Rights Reserved.
INSTRUCTION/INSTALLATION SHEET
lyriQ™ Studio Local Source Input
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
delay for switching back to the main audio source after the local audio source is no longer present.
NOTE: Clockwise rotation increases sensitivity and time delay, while Counter Clockwise rotation
decreases sensitivity and time delay.
There is a jumper on the rear that determines whether the lyriQ™ Studio Local Source Input works in Knob
mode or Keypad mode (see NOTE after Installation step B3).
NOTE: The lyriQ™ Studio Local Source Input, like other On-Q/Legrand lyriQ™ Audio system
components, is powered by the On-Q/Legrand lyriQ™ Audio Distribution Module.
3. Installation
Installation of the On-Q lyriQ™ Studio Local Source Input is best accomplished in two steps during new
construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and
painted.
NOTE: The On-Q/Legrand lyriQ™ Studio Local Source Input is typically mounted at electrical outlet
height. Measure the height of the nearest box on the same wall that the lyriQ™ Studio Local Source Input
will be installed and place the electrical back box at the same height. Position the cabling to maintain
separation of any low voltage cable such as Category 5 from AC power wiring. Special applications, such
as audio from a TV, entertainment center, or a computer, may require different heights including those
above the chair rail, such as in the kitchen.
A. “Rough-in” steps:
1. Run Category 5 cable from the lyriQ™ Audio Distribution Module located in the Enclosure to the single
gang box at the location that will contain the lyriQ™ Studio Local Source Input. Also run Category 5
cable from the single gang box that will contain the lyriQ™ Studio Local Source Input to the volume
control location (or to the second lyriQ™ Studio Local Source Input and then to the volume control
location).
NOTE: If optional 16/4 speaker cable is run with the Category 5 cable for potential upgrade to high
performance keypads in the future (see Figure 3 and 4), it can be run directly from the enclosure to the
volume control.
B. “Trim-out” steps:
NOTE: Always follow TIA-570-B and T568A wiring standards for installing and terminating Category 5
cable. Failure to follow the correct wiring standard could result in damaged equipment and/or electrical
interference issues.
NOTE: Maintain a minimum 12” separation between Category 5 cable and any 120VAC cabling.
1. At the intended Studio Local Source Input location, pull the prewired Category 5 cable from the
lyriQ™ Audio Distribution Module out of the single gang box and terminate it with an RJ45 plug and
snap it into the RJ45 jack labeled “INPUT” on the rear (see Figure 2).
2. Pull the prewired Category 5 cable from the lyriQ™ Volume Control (or next Studio Local Source
IS-0421 REV. O
Page 2 of 4
©Copyright 2008 by On-Q/Legrand All Rights Reserved.