Legrand ADSM703H User Manual [en, fr, es]

adorne
P
GAG
-
W
1-POLE
STRIP GAGE
HOT
DO NOT USE
PLATE INSTALLED
WITHOUT A WALL
TOP
AY
1-POLE
STRIP GAGE
3-WAY WHITE
HOT
TM
SensaDimmer - Auto ON/Auto OFF, 700W, SP/3W
No: 340977 – 07/12 Rev. 1
Catalog Number(s): ADSM703H
Country of Origin: Made in China
Frame
Frame Ground Wire
WARNING To prevent severe shock or electrocution,
1
always disconnect power at the service panel before beginning work.
When replacing existing switches, label wires before disconnecting. Disconnect old switch.
Spacers
Wall Plate
Switch Ground Wire
SensaDimmer
TOP
INSTALLATION INSTRUCTIONS
For more information and helpful how-to videos, visit www.adornemyhome.com/install.
INSTALLATION INSTRUCTIONS Please read these instructions completely before you begin. adorneTM dimmers are designed for installation in standard electrical boxes. However, some of the installa­tion methods vary slightly from traditional methods. If you do not understand these instructions or are unsure of your abilities, seek the assistance of a qualified electrician.
Remove spacers from the frame.
Since this dimmer fills the frame completely, you will not need the spacers. From the back of the frame, pinch the tabs on the spacer to release.
Single Pole
NOTE: NEUTRAL wire is not required for sensor to function properly.
Use only with Legrand adorneTM system.
SPECIFICATIONS Voltage - 120VAC, 60Hz Load (Single Pole or Multi-way) Incandescent, LED and CFL - 15-700 Watt Derating Factor: 2-gang: 600 Watt 3-gang and above: 500 Watt Adjustable Time Delay - 5 sec (test mode), 5 min - 30 min Environment - Residential Indoor Use Only Humidity - 95% RH, non-condensing
Installation Shall Be In Accordance With All Applicable Regulations, Local And NEC Codes.
3-Way
In a 3-Way circuit, Traveler wires are the two insulated wires con­nected to the switch that are NOT the HOT wire that you identified previously.
2
3
Briefly restore power and use a line voltage meter to identify the wires.
HOT or LINE (usually black) - runs from service panel to switch LOAD Runs from switch to fixture NEUTRAL (usually white) The old switch may not have used a NEUTRAL wire, but it is usually available in the box. GROUND - bare copper or Green wire with or without yellow stripe
DISCONNECT power at the service panel once you’ve identified the wires.
If necessary, cut wires and strip insulation using stripping guide on back of switch.
WARNING To Reduce Risk of Electrical Shock, unit shall be properly grounded in accordance with NEC and Local Codes. Failure to connect the ground wire will result in an unsafe installation that could lead to personal injury.
Connect frame ground wire and dim­mer ground wire to bare ground wire in box. Fold ground wires into back of box. Mount frame to wall box with screws provided. Tighten screws just enough to hold frame in place. Do NOT over-tighten.
Ground Neutral Hot/Line Load
Ground Neutral Hot/Line Load Traveler
TIPS
• Pre-fold wires into wall box to make it easier to fit them in the
box when dimmer is connected.
• Use caution to avoid marring wall surface with the metal frame.
3-WAY
WHITE
STRIP
GAGE
HOT
4
Single Pole
Connect dimmer as shown. Make sure the terminal holes are clear. Insert wires into terminals and tighten screws securely.
• Connect LINE wire to HOT terminal on sensor
• Connect LOAD wire to 1-POLE terminal
• Connect NEUTRAL from the circuit and from
lamp (LOAD) to WHITE terminal
NOTE: NEUTRAL wire is not required for dimmer to function properly.
Ground Neutral Hot/Line Load
3-WAY
WHITE
HOT
1-POLE
WARNING: Do not pair different size wires in the same terminal. If you have different size wires, use a wire nut to add a 6-inch pigtail of the same gauge wire to the smaller gauge wire.
Same size. Different size.Different size with pigtail.
TOP
5
STRIP
GAGE
AY
W
-W
3-W
3
WHITE
1-POLE
STRIP
3-WAY
WHITE
HOT
AY
1-POLE
STRIP GAGE
3-WAY WHITE
HOT
1-POLE
STRIP GAGE
3-WAY WHITE
HOT
1-POLE
STRIP GAGE
3-WAY WHITE
HOT
TOP
TOP
TOP
3-Way
The term master designates the dimmer that connects to the load. The term auxiliary refers to the dimmer that does not connect to the load.
3-Way Master
3-Way Auxiliary
6
Master
• Connect NEUTRAL wire from the circuit and from the
lamp (LOAD) to WHITE terminal
• Connect LINE wire to HOT terminal
• Connect LOAD wire to 1-POLE terminal
• Connect TRAVELER wire to the 3-WAY terminal
NOTE: NEUTRAL wire is not required for dimmer to function properly.
Auxiliary
• Connect NEUTRAL wire from circuit in the other wiring
box to WHITE terminal
• Connect LINE wire to HOT terminal
• Connect TRAVELER wire to the 3-WAY terminal
• 1-POLE terminal on auxiliary is not used.
NOTES: A light can be controlled by one master and up to four auxiliary dimmers.
If you are installing multiple devices in the frame, wire all devices before snapping them into the frame.
Carefully fold wires into box. Snap sensor into frame.
1
3
2
4
7
3-WAY
WHITE
HOT
1-POLE
Snap wall plate to frame. There are three click-stops to adjust the fit of the wall plate to the dimmer and the wall.
Ground Neutral Hot/Line Load Traveler
3-WAY
WHITE
STRIP
HOT
1-POLE
Ground Neutral Hot/Line Load Traveler
For multi-gang installations the dimmer needs to be derated per the chart.
Multi-Gang Derating
Installation Single 2-Gang 3 or more-Gang Maximum Load 700W 600W 500W
NOTE – If you need to remove dimmer after snapping into frame, first remove frame from wall box to access the four locking tabs on the back of the sensor. Insert a flat screwdriver to depress tabs as you apply pressure to push switch out.
OPERATION
On/Off Button
Dimming Paddle
Light Level LEDs
Locator LED
Lens
Never apply cleaner directly to the dimmer or wall plate. Apply to a soft cloth and use cloth to remove any smudges from the product.
Coverage Area
The ADSM703H has a maximum coverage range of 180 degrees and a coverage area of 600 sq. ft. The sensor must have a clear and unobstructed view of the coverage area. Objects blocking the sensor’s lens may prevent detection thereby causing the light to turn off even though someone is in the area. Windows, glass doors, and other transparent barriers will obstruct the sensor’s view and prevent detection.
Major Motion 35’ (10.6 m)
Minor Motion 20’ (6 m)
7.5’ (2.2 m) 15’ (4.5 m)
Technical Assistance:
(877) 295-3472 www.adornemyhome.com/install
LIMITED LIFETIME WARRANTY
Limited lifetime warranty information for adorneTM products is available at www.adornemyhome.com/ warranty. Limited warranty information for adorne products may also be obtained free of charge by sending a written request, along with your proof of purchase (including purchase date), to: Legrand Attn: adorne Customer Service/Warranty Department 50 Boyd Avenue Syracuse, NY 13209
No: 340977 – 07/12 Rev. 1
© Copyright 2012 Legrand All Rights Reserved.
The ADSM703H is designed to replace a standard single pole or multi-way switch or dimmer. The dimmer uses passive infrared technology to sense human motion in a space and turn the lights ON when occupancy is detected and OFF when the room is vacant. It is ideal for applications in a home where there is a direct line of sight from the dimmer to the room and where dimming control is desirable such as bedrooms or family/living rooms.
Upon detection of occupancy the dimmer will turn the light ON. Pressing and holding the top of the dimming paddle will brighten the connected light. Pressing and holding the bottom of the dimming paddle will dim the connected light. The light level LEDs indicate the brightness of the connected light. See ‘Tap Input’ section for more details on dimmer operation. The dimmer will keep the connected light on until no motion is detected for the selected time delay. If the controlled load is turned off manually by pressing the on/off button (e.g. to keep the lights off while watching a movie) the dimmer will keep the connected load off as long as it is detecting motion. The dimmer will automatically switch back to automatic-on operation when no motion is detected for 5 minutes. If motion is detected within 30 seconds after it automatically turns OFF, the ADSM703H automatically turns the load back ON. The dimmer will automatically turn the lights on to the last light level.
The dimmer is factory preset to function with automatic-on operation. It can be adjusted to function in manual-on mode. See ‘Adjusting the operating mode’ section.
LED functionality
The dimmer has one locator LED on the ON/OFF button in addition to 7 light level LEDs. When the connected light is off the locator LED will be on and the light level LEDs will be off. When the connected light is on, the locator LED will be off and the light level LEDs will be on indicating the brightness of the light.
Note: The LEDs will only function when the neutral wire is connected. When the neu­tral wire is not connected the dimmer will function properly, but the locator LED and light level LEDs will never be illuminated.
See Step 4 above for details on how to wire the dimmer.
Initial Power Up Supply
There is an initial warm-up and calibration period the first time power is applied to the dimmer, after a power failure lasting more than 5 minutes and after the load is replaced.
DIMMER ADJUSTMENT & PROGRAMMING Adjusting the time delay
The factory setting for the time delay dial is 15 minutes. To increase the amount of time the load remains ON after the last motion detection, turn the dial clockwise (maximum = 30 minutes). To reduce the amount of time the load remains ON after the last motion detec­tion, turn the dial counterclockwise (minimum = 5 minutes). The unit will enter test mode if the trimpot is turned fully counter-clockwise. Stop just before turning the trimpot completely counter-clockwise to avoid entering test mode. See Test Mode section for further details.
CAUTION Do not overturn the time delay adjustment dial.
Adjusting the light level
Adjust the light level setting to prevent the dimmer from automatically turning on the lights when there is enough ambient light present in the space. This feature’s default setting is disabled so that even the brightest light will not prevent the dimmer from turning the connected load on when it detects occupancy. Follow these steps to enable the light level:
• The light level must be set when the lights would normally be turned off because there is
enough ambient light
• Wait until the time of day when the space is bright enough with the ambient light and
does not need additional electric light
• Flip the dip switch labeled “light level” to the on position
• Any time the ambient light gets to the current level or brighter the dimmer will not turn the
lights on automatically
• To disable this feature, turn the “light level” dip switch to the off position
Adjusting the operating mode
The dimmer has two operating modes – automatic-on and manual-on. The dimmer’s default setting is automatic-on and will turn the lights on automatically when occupancy is detected. Lights will turn off automatically once motion is no longer detected and the time
delay expires. If manual-on operation is preferred, flip the dip switch labeled “On Mode” to
the on position. Now the lights will no longer automatically turn on. The on/off button must be pressed in order to turn the lights on. Lights will turn off automatically once motion is no longer detected and the time delay expires. To switch back to automatic-on operation, flip
the dip switch labeled “On Mode” to the off position.
Disabling the locator LED
The locator LED can be disabled by pressing and holding the on/off button for 10 seconds. After 10 seconds the locator LED will flash to indicate that the locator LED has been
Dip Switch Settings
Time Delay Trimpot
TM
TOP
Light Level Dip Switch
On Mode Dip Switch
NOTE – To remove wall plate, insert a small, flat screwdriver in notches on wall plate and twist gently to pry from frame.
disabled. To enable the LED, press and hold the on/off button for 12 seconds. The locator LED will flash at 10 seconds, continue to keep holding down the on/off button until the locator LED flashes twice at 12 seconds indicating that the LED has been enabled.
Changing the dimming curve
The dimmer’s default setting is to control incandescent lamps. If the connected load is a fluorescent lamp (e.g. CFL) the dimming curve must be changed so that the device will function properly. To change the dimming curve:
• Press and hold the on/off button and bottom of the dimming paddle simultaneously for 10
seconds. The locator LED will flash indicating that the dimming curve has been set.
• To change the dimming curve back to its default setting of controlling incandescent loads
press and hold the on/off button and the top of the dimming paddle for 10 seconds. The locator LED will flash indicating that the dimming curve has been set.
Test Mode
Activate test mode in order to test the detection coverage. If the neutral wire is connected, the locator LED will blink indicating that the unit is in test mode. During test mode the controlled load turns on for 5 seconds each time the dimmer detects occupancy. Follow these steps:
• Turn the time delay trimpot fully counter-clockwise.
• Move out of the coverage area or stand very still. The controlled load turns off after
5 seconds if no motion is detected.
• Move into the coverage area. The controlled load turns on for 5 seconds each time the
dimmer detects motion. After 5 seconds expires without motion detection, the load turns OFF. The controlled load turns on automatically with the next motion detection and stays on for 5 seconds.
• Repeat as necessary to ensure that the desired coverage area is within detection range.
• The device will remain in test mode for 5 minutes before automatically converting back to
normal operation. If additional time is needed, turn the trimpot away from the minimum setting, and then turn back to its minimum setting, resetting the 5 minutes.
• Turn the trimpot back to the desired time delay once the coverage area has been verified.
TAP INPUT On/Off button
• Momentary push with Load Off turns Load On to LDL (last dim level).
• Momentary push with Load On turns Load Off.
• Push and hold approximately 2 sec with Load On fades Load Off over approximately 30 sec (“go to bed” feature). During the slow fade-off interval the top-most lit LED in the bargraph will ash.
• Double-tap with Load Off turns Load On to maximum brightness.
• Double-tap with Load On turns Load On to maximum brightness.
Top of Dimming Paddle
• Momentary push with Load Off turns Load On to LDL (last dim level).
• Momentary push with Load On increases brightness 1 increment (approx 5% of max
brightness).
• Push and hold with Load On ramps brightness up (approx 5 sec from min to max).
• Double-tap with Load Off turns Load On to maximum brightness.
Bottom of Dimming Paddle
• Momentary push with Load Off turns Load On to LDL (last dim level).
• Momentary push with Load On decreases brightness 1 increment (approx 5% of max
brightness).
• Push and hold with Load On ramps brightness down (approx 5 sec from max to min).
• Double-tap with Load Off turns Load On to maximum brightness.
TROUBLESHOOTING Status LED is enabled but the load will not turn ON:
• Check the lamp to make sure that it has not burned out.
• Check the circuit breaker to be sure it is functioning.
No status LED:
• Check the ground and neutral connections (note: neutral is not required for product to
function properly).
Load will not turn ON:
Press the ON/OFF button. The load should turn ON. If not:
• When power is applied, there is up to a 20-second delay before the device is operational.
Wait 20 seconds and try again to turn on the load.
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn off power to the circuit then check wire connections.
Load will not turn OFF:
Make sure there is a solid ground connection. The device requires the ground connection to operate. Note: The time delay can be set from 5 minutes to 30 minutes. Ensure that the time delay is set to the desired delay and that there is no movement within the dimmer’s view for that time period.
• To quickly test the unit for proper operation, turn the time delay to minimum and move out
of the dimmer’s view. Lights should turn off after 5 seconds.
• Press the ON/OFF button. If load does not turn off, turn off power to the circuit then check wire connections.
Factory reset
To change the operating mode back to the default settings press and hold the on/off button for 15 seconds. The locator LED will flash once at 10 seconds, continue to press and hold the on/off button. The locator LED will flash twice at 12 seconds, continue to press and hold the on/off button. The locator LED will flash 3 times at 15 seconds signaling that the device has been reset.
60 Woodlawn Street West Hartford, CT 06110