Models Affected:
Linea – ALL
TECHNICAL REFERENCE 021503/28
FB-70 – ALL
_____________________________________________________________________________________________
INTRODUCTION OF NEW PRESSURE SWITCH
La Marzocco will be replacing the existing pressure switch (L270) with a new pressure switch (L271-see below) on
all espresso machines. This change will be applied on the following serial numbers:
UL Listed Machines
• B04236, B04237, B04241-B04243, B04279-B04290, B04294-B04296, and B04298 and greater.
• 21400, 21454 and greater
CE Listed Machines
• 21926 and greater
With this application an electrical contactor is also added to handle the power switching requirements of the steam
boiler heating element.
NOTE: This pressure switch requires a short break in period of approximately 20 days (this will vary upon use of
the machine). The Pressure switch should be set to 1.2 – 1.3 bar upon installation. After the break-in period, the
pressure switch will achieve approximately 1.5 bar pressure.
TECHNICAL BULLETIN #28
February 15, 2003
P/N – L271
L27 1- P res su r e Switch
___________________________________________________________________________________________________________________________________________________________________________________________
Page 1 of 1