La Crosse Technology WS-9060U-IT User Manual

1
LCD
Display
Function key
Function keys
WS-9060U-IT FORECAST STATION
Battery compartment
Hanging hole
2
3
+ key
MIN/MAX key
SET key
4
New Moon
Waning Crescent
First Quarter
Waxing Gibbous
Waxing Crescent
Last Quarter
Full Moon
Waning Gibbous
Bar segment (moon phase indicator)
INTRODUCTION: Congratulations on purchasing this state-of-the-art weather station as an example of innovative design and quality piece of engineering. Providing time, calendar, weather forecast, moon phase, indoor and outdoor temperature, indoor and outdoor relative humidity. This unit will never keep you guessing on current and future weather conditions.
The Weather Station
FEATURES:
x 12/24 hour time display x Calendar display (year shows only in set mode) x Display 8 Moon phases throughout the year x Weather forecasting with weather tendency indicator x Indoor and outdoor temperature display with
MIN/MAX records
x Temperature display in ºC/ ºF x Indoor and outdoor humidity display x Humidity data display as RH% x Low battery indicator
Quick Setup Guide
INITIAL SETUP:
Do not mix old and new batteries. Do not mix alkaline, standard, or rechargeable batteries
1. Install batteries (2-AAA LR3, 1.5V) into the Thermo­hygro Transmitter according to polarity.
2. Install batteries (2-AAA LR3, 1.5V) into the Weather Station according to polarity.
3. Place the transmitter and weather station 5-10 feet apart. When the batteries are inserted, the weather station will start receiving data signal from the transmitter. The outdoor temperature and humidity data should be displayed on the weather station.
4. If this does not happen after 2 minutes, the batteries will need to be removed from both units and reset from step 1.
5. If the outdoor temperature and humidity are displayed for 15 minutes, the transmitter can be placed outside.
Note:
When changing batteries in the units, ensure the batteries do not spring free from the contacts. Always wait at least 15 minutes after removing the batteries before reinserting, otherwise start up and transmission problems may occur.
TO INSTALL AND REPLACE BATTERIES IN THE THERMO-HYGRO TRANSMITTER
The outdoor thermo-hygro transmitter uses 2 x AAA, IEC LR3, 1.5V batteries. To install and replace the batteries, please follow the steps below:
setting up procedures. This is due to a random security code assigned by the transmitter at start-up. This code must be received and stored by the weather station in the first 3 minutes of power being supplied to the transmitter.
1. Remove the battery cover.
2. Insert the batteries, observing the correct polarity (see battery compartment marking).
3. Replace the battery cover on the unit.
Note:
When changing batteries in any of the units, all units need to be reset by following the
TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION
The weather station uses 2 x AAA, IEC LR3, 1.5V batteries. To install and replace the batteries, please follow the steps below:
BATTERY CHANGE:
It is recommended to replace the batteries in all units on an annual basis to ensure optimum accuracy of these units.
FUNCTION KEYS:
Weather Station:
The Weather Station has 3 easy to use function keys: 1 key on the front, and 2 keys on the back
Please participate in the preservation of the environment. Return used batteries to an authorized depot.
1. Insert finger or other solid object in the space at the bottom center of the battery compartment and lift up to remove the cover.
2. Insert batteries observing the correct polarity (see marking).
3. Replace compartment cover.
MANUAL SETTINGS: The SET key will move you through the program menu. The + key will change a value.
12/24-HOUR TIME: Hold the SET key and 12h or 24h will flash. Use the + key to select 12-hour or 24-hour time. Press and release the SET key to confirm and continue. HOUR: The Hour will flash. Use the + key to select the Hour. Press and release the SET key to confirm and continue. MINUTES: The Minutes will flash. Use the + key to select the Minutes. Press and release the SET key to confirm and continue. YEAR: The Year will flash. Use the + key to select the Year (the year will not display on the weather station). Press and release the SET key to confirm and continue. MONTH: The Month will flash. Use the + key to select the Month. Press and release the SET key to confirm and continue. DATE: The Date will flash. Use the + key to select the Date. Press and release the SET key to confirm and continue. °F/°C TEMPERATURE: °F/°C will flash. Use the + key to select the °F or °C . Press and release the SET key to confirm and exit the manual settings.
MOON PHASES SYMBOL
The moon icon of the weather station will also display all 8 moon phases throughout the year according to the set calendar. A bar segment above the moon phase will indicate current moon phase.
WEATHER FORECASTING ICONS:
The weather icons in the second section of LCD can be displayed in any of the following combinations:
5
For every sudden or significant change in the air pressure,
6
Moon
phase
icon
Weather tendency indicator
Calendar
Indoor relative humidity in RH%
Indoor
temperature
in ºC/ºF
Weather
forecast icon
Outdoor data signal reception indicator*
Outdoor
temperature
in ºC/ºF
Outdoor relative humidity in RH%
Time
Low battery indicator (weather station)
Low battery indicator (transmitter)
7
Mounting at a sheltered place. Avoid
hygro transmitter can be
8
the weather icons will update accordingly to represent the change in weather. If the icons do not change, then it means either the air pressure has not changed or the change has been too slow for the Weather station to register
The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates. All reading should be disregarded for the first 48 hours after set up.
WEATHER TENDENCY INDICATOR
Working together with the weather icons is the weather tendency indicators (located on the left and right sides of the weather icons). When the indicator points upwards, it means that the air-pressure is increasing and the weather is expected to improve, but when indicator points downwards, the air-pressure is dropping and the weather is expected to become worse.
MIN/MAX DATA
VIEW THE MIN/MAX DATA
Press the MIN/MAX key several times to view the MIN/MAX indoor temperature, and MIN/MAX outdoor temperature sequentially.
RESET THE MIN/MAX DATA Press and hold MIN/MAX key for 3 seconds to reset all the indoor and outdoor temperature to current temperatures.
LOW BATTERY INDICATOR
Low battery indicator is displayed on the LCD by the time when the batteries require changing in the display. The low battery indicator is displayed in the outdoor temperature area when the batteries in the transmitter require changing.
LCD SCREEN
The LCD screen is split into 5 sections displaying the information for time/calendar, weather forecast, moon phase, indoor data, and outdoor data.
* When the signal is successfully received by the weather station, the outdoor transmission icon will be switched on. (If not successful, the icon will not be shown on LCD). The user can then easily see whether the last reception was successful (icon on) or not (icon off).
THERMO-HYGRO TRANSMITTER
The temperature may affect the range of the thermo-hygro transmitter. At cold temperatures the transmitting distance may be decreased. Please bear this in mind when positioning the transmitters. Also the batteries may be reduced in power for the thermo-hygro transmitter.
POSITIONING THE THERMO-HYGRO TRANSMITTER
and humidity readings are receivable. In event that the signal is not received, relocate the thermo-hygro transmitter or the weather station slightly as this may help the signal reception.
POSITIONING THE WEATHER STATION
The weather station provides the option of table standing or wall mounting the unit. Before wall mounting, please check that the outdoor data can be received from the desired locations.
direct rain and sunshine.
The thermo­placed onto any flat surface or wall mount using the bracket which doubles as a stand or wall mount base.
To wall mount:
1. Secure the bracket onto a desired wall using the screws and plastic anchors.
2. Clip the transmitter onto the bracket.
Note: Before permanently fixing the thermo-hygro to the wall base, pace all units in the desired locations to check that the outdoor temperature
To wall mount:
1. Fix a screw (not supplied) into the desired wall, leaving the head extended out by about 5mm.
2. Place the weather station onto the screw, using the hanging hole on the backside. Gently pull the weather station down to lock the screw into place.
Foldout table stand:
The foldout table stand leg is located on the backside. Pull the stand out from the bottom center edge of the weather station, below the battery compartment. Once the foldout table stand is extended, place the weather
CARE AND MAINTENANCE:
x Extreme temperatures, vibration and shock should
be avoided as these may cause damage to the units and give inaccurate forecasts and readings.
x When cleaning the display and casings, use a soft
damp cloth only. Do not use solvents or scouring agents as they may mark the LCD and casings.
x Do not submerge the units in water. x Immediately remove all low powered batteries to
avoid leakage and damage. Replace only with new batteries of the recommended type.
x Do not make any repair attempts to the units. Return
it to their original point of purchase for repair by a qualified engineer. Opening and tampering with the units may invalidate their guarantee.
x Do not expose the units to extreme and sudden
temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy.
SPECIFICATIONS: Temperature measuring range:
Indoor : 14.2°F to +139.8°F with 0.2°F resolution
-9.9ºC to +59.9ºC with 0.1°C resolution (“OF.L” displayed if outside this range) Outdoor : -39.8°F to +139.8°F with 0.2°F resolution
-39.9ºC to +59.9ºC with 0.1°C resolution (“OF.L” displayed if outside this range) Indoor humidity range : 20% to 95% with 1% resolution
(Display “- -“ if temperature is OF.L; display “19%“ if < 20% and “96%” if > 95%)
Outdoor humidity range : 1% to 99% with 1% resolution (Display “- -“ if outside temperature is OF.L; display 1% if < 1% and 99% if > 99%)
Data checking intervals
station in an appropriate location.
Loading...
+ 1 hidden pages