La Crosse Technology WS-9002U, WS-9002CAMO, WS-9002U User Manual

WS-9002U
Wireless 433 MHz
Temperature Station
Instruction Manual
1
Topic Page
Inventory of Contents 3 Quick Setup 4-6 Detailed Setup Guide
Battery Installation 7-8
Features
Minimum and Maximum Temperatures
Resetting Minimum and
Maximum Temperatures Additional remote temperature sensors (optional) Mounting 12-14 Troubleshooting 14-16 Maintenance and Care 16 Specifications 17-18 Warranty Information 19-23
9
9
10-12
2
INVENTORY OF CONTENTS
1.
The indoor temperature station (Figure
1)
2.
The remote temperature sensor (TX6U) and mounting bracket. (Figure 2)
3.
3 each, 1/2” Philips screws.
4.
One strip of double sided adhesive tape.
5.
Instruction Manual and Warranty Card.
Figure 1
ADDITIONAL EQUIPMENT
(not included)
1.
1 Philips screwdriver.
2.
2 Fresh AAA 1.5V batteries.
3.
2 Fresh AA 1.5V batteries.
Figure 2
3
QUICK SETUP
Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries.
1. Have the indoor
temperature station and remote temperature sensor 3 to 5 feet apart.
2. Batteries should be out of
both units for 10 minutes.
3. Place the batteries into the
remote temperature sensor first then into the
indoor temperature station. (All remote temperature sensors must be started before the indoor temperature station)
4. DO NOT PRESS ANY
BUTTONS FOR 15
MINUTES.
4
In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature. If the indoor temperature station does not display both temperatures after the 15 minutes please retry the set up as stated above. After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoors and set your time.
The remote temperature sensor should be placed in a dry, shaded area. The remote temperature sensor has a range of 80 feet. Any walls that the signal will have to pass through will reduce distance. An outdoor wall or window will have up to 20 feet of resistance and an interior wall will have up to 10 feet
5
of resistance. Your distance plus resistance should not exceed 80 ft. in a straight line. NOTE: Fog and mist will not harm your remote temperature sensor but direct rain must be avoided.
6
DETAILED SETUP GUIDE
I.
BATTERY INSTALLATION
A.
REMOTE TEMPERATURE
SENSOR
1.
Remove the mounting bracket.
2.
Remove battery cover
3.
Observing the correct polarity, install 2 AA batteries—make sure they do not spring free, or start-up problems may occur. Replace cover.