This document provides general product information and
specifications. Please visit www.lacrossealerts.com for
Login to your account at www.lacrossealerts.com and
choose model TX71U-IT on the website to begin the set up
process with step-by-step inst ructions. Enter the k ey fr om the
ACTIVATION KEY CARD (included in the package) when
Use your smartphone, tablet or computer to monitor for water
leaks that could lead to frozen pipes and mold growth.* Water
damage can originate in almost any room: frozen pipes, broken
pipes, broken dishwasher hose or leakage, washing machine
overflow, leaking roof, basement leaks, foundation cracks,
plumbing leaks, sump pump overflow and leaks from bad
weather such as snow, rain or floods.* The good news is that
water damage is a costly problem that you can prevent: Simply
connect the gateway to your network router to enable remote
monit or ing w i th t ext and e-mail alerts from an ywhere with
Internet access.*
Wall-mount the water detector , or use tabletop bracket/stand,
and place the H2O sensor on the floor to monitor the area for
water.* Alerts are sent if water is detected, if the batteries are
low or if t he connection is l ost. *
MONITORING OPTIONS
• Hom e, second home, off ice or ren tal prop erty
• Kitchens, baths, laundry & pool rooms
• Uti l it y s inks, sumps & w ater heaters
• Basements, garages & attics
• Near aqu ariums & t errar iums
• Greenhouses & farms
PRODUCT OVERVIEW GUIDE
WIRELESS REMOTE WATER DETECTOR
Model: D013.105.M3
IMPORTANT:
complete product set up and activation instructions.
prompted by t he website.
Need help? Visit:
www.lacrossetechnology.com/support/alerts
GENERAL USE AND APPLICATIONS
PACKAGE CONTENTS
HARDWARE CONTENTS:
1. Wireless remote water
detector with mounting
bracket (TX71U-IT)
2. H20 (water) sensor on 6 Ft.
detachable cable (D000.105)
that detects WET (H20) or DRY
(DRY) conditions.
3. Screws and drywall anchors
PRINTED MATERIALS CONTENTS:
4. Printed Product Overview Guide (this document)
IMPORTANT: Product set up and activation
instructions are on li ne: www.lacrossealerts.com
5. IMPORTANT: Activation Key Cardrequired for
set up and activation. Do not throw away.
ADDITIONAL EQUIPMENT (NOT INCLUDED)
• Two fresh AAA, IEC LR03, 1.5V Alkaline batteries
• Two-sided tape as need ed
• Browser with high s peed Int ernet
• Network router
• Existing La Crosse Alerts Internet Gateway with mounting
bracket, AC adapter and LAN cable (sold separ atel y )
FEATURES AND MEASUREMENTS (Diagram 1)
water sensor.
into it.
LED
with 6-foot
wire to plug
(A) W ireles s Remote Water Detector:
• LCD displays water s t atus: WET (H20) or DRY
• Transmits collected data to your Internet Gateway
(not included) within a 200 Ft. wireless range.
•Weather res ist ant case (not water proof)
Note: The case with LCD cannot get wet and may
be affected by high humidity conditions.
• Wall hanging or free standing
(B) H20 Water Sensor on 6 Ft. Detachable Cable:
• H20 sensor detects the presence or absence of water
• ** At tach it to the water detector case a nd place t he
sensor on the floor or other area you wish to monitor
for WET/DRY conditions.
•**The offic ial D 000.105 H20 Sensor can be plugged
into the sensor at any time without resetting.
HOW IT WORKS
•The wir eless sensor transmits data to the Internet
Gateway (not included) withi n a 200 Ft. (60.96m) range.*
•The Internet Gateway (not included) connects to your
existing network router and uses your high-speed Internet
connection to upload collected measurements to your own
account at www.lacrossealerts.com.*
•Once the sensor is activated with the Internet Gateway
(not included), you monitor sensor(s) from a smartphone,
tablet or computer on www.lacrossealerts.com, and set
up c ustom e-mail/text alerts* .
•Add up to 5 sensors (sold separately) per Internet gateway
(not included) to monitor additional areas.
Page 2
PREPARE FORSETUP
1. Begin set up near your existing network router and a
computer with high-speed Internet ac cess.
2. Unpack package contents and insert the H2O sensor cord
into the TX71U-IT water d etector (see d iagram 1) .
SETUP AND ACTIVATION
1. Locate the Activation Key Card in the package for setup
instructions and the Activation Key. The Activation Key i s
necessary to activate your sensor with Internet Gateway
(sold separately). Keep yo ur Ac t ivat ion C ard f or reference.
2. Visit www.lacrossealerts.com with your Activation Key
Card to create your account and activate the product.
ACTIVATION INFORMATION:
THE INCLUDED ACT IVATION K EY is good for
3 Months of ENHANCED SERVICE with ear ly warni ng
text & e-mail alerts, plus 4 more years of BASIC
SERVICE for standard remote monitoring.
Once the sensor is acti vated and buildi ng a mea suremen t l og,
you can download the data as a comma separated values
(CSV) file. You must use an application such as Microsoft
Excel® or Google Docs® that supports comma separated
values ( CSV) form att ed files to view the t able d ata.
SELECT A LOCATION TO MOUNT WATER DETECTOR
• Select a location protec ted f rom w ater and ot her
precipit at ion. Th e case is wat er resistant , not wat er proo f.
• Place the sensor in a dry, shaded area. Avoid locations with
direct sun, to prevent in accurat e r eading s.
• Fog and mist will not harm the sensor but direct precipit atio n
must be avoided.
•Note: Exposing the sensor case to extreme humidity may
tem por arily dis rupt dat a. The water detector with L CD should
not be submerged in water.
• Attach the H2 0 cable sen sor to the R emote Water D etector
case and place it on the floor for w ater monitori ng. Secure
the Remote Water Det ector case in a n area that is pr otected
from water. Once activated, the H2O/Dry readings will
display on the LCD.
• The H20 sensor on 6 ft. cable is not for use in a pool or hot
tub where chemicals may cause malfunction.
• Select a location within range of the Internet Gateway
(see “IMPORTANT SETUP & OPERATION NOTES”).
CONFIRM CONNECTION BEFORE MOUNTING
•IMPORTANT: Before permanently mounting…Test sensor
in the desired mounting location for at least 1 hour to
confirm good reception. Confirm consistent readings on your
account at www.lacrossealerts.com before permanently
mounting. Move the sensor closer to the Internet Gateway if the signal is lost or not received.
•Mount the sensor after the activation process
(see “SETUP AND ACTIVATION”).
MOUNT TO WALL WITH SCREWS
1. Remove the mounting bracket
2. Place bracket over the desired
location.
3. Mar k mounting surfac e wit h a pencil
through the 2 holes of the bracket.
4. Screw brack et onto surface and
tight en screws t o bra cket.
5. Insert t he sensor back into the bracket.
FREE STANDING
Attach the mounting bracket to the bottom or
top of the sensor and place it o n any fl at surface.
PLACEMENT OF THE H2O SENSOR
The H2O sensor should be placed on the dry floor or against
the wall near your foundation, water heater, sump, plumbing,
was her a quar ium, or di sh washer etc. t o m onitor f or lea ks.
FLOOR:
Place the H2O sensor (circuit board down) on
the dry floor within range of the remote water
detector case that is mounted on the wall or
standing on a table. Note: The water det ector
wil l sit 1/8 i nch from t he fl oor i n t his posit ion.
WALL:
Place the H2O sensor against the wall with the
edge touching the floor within range of the
remote water detector case that is mounted on
the wall or standing on a table.
• The H2O sensor can b e secu red to the floor or wall with t he
included screws & anchors or with two-sided tape (not
included).
• Secu re the 6 ft. H2O s enso r cable to avoid tripping hazards:
Loosely coil and secure the extra cable with a twist tie.
CLEANING THE H2O SENSOR
Routine cleaning of the H2O sensor
is recom mend ed to ensure proper
operation.
Use clean water and a soft cloth to clean dirt and debris from
the cir cuit boar d of th e H 2O sensor . Note: When using twosided tape, replace the tape after cleaning the H2O sensor to
mai ntain adhesi venes s.
Page 3
IMPORTANT SETUP & OPERATION NOTES
6 ft. detachable water sensor cable
• The s enso r has a wireless range of 200 feet (60.96 m). The
200 ft. range equates to open air with no obstructions, and
that radio waves DO NOT curve around objects. Actual
transmission range will vary depending on what is in the path
of the signal. Each obstruction (roof, walls, floors, ceilings,
etc.) wi ll effecti vely cut signal range in half.
• Metal, stucco, and some ty pes of glass ca n redu ce signal
range by as much as ¾ or more, compared t o t he ½
reduction typical of most obstructions. It is possible to
receive a signal through these materials, however maximum
range will be reduced due to their tendency to absorb or
reflect a much larger portion of the sensor’s signal.
• The Wir eless Rem ote Water Detector updates the water
status on the LCD every 6 seconds.
Note: The new measurement is reported to your account at
intervals that you select using your online account.
BATTERY REPLACEMENT
1. Remove the battery cover by sliding the c over d own.
2. Observing the correct polarity install 2-AAA batteries.
Batteries will fit tightly. Avoid start -up problems by
making sure t he batteries do not spring free.
3. Do not m ix ol d and n ew batteri es.
4. Do not mix alkaline, lithium, standard or rechargeable
batteries.
5. Replace the battery cover by sliding upwards and check that
it is securely fitted.
LOW BATTERY INDICATOR
• Low batt ery icon appears on LCD when batteries are low.
• You will receive an e-mail or mobile text message alert when
the battery power of the sens or is low. Change the bat teries
immediately.
Note: The LED light turns ON briefly after changing batteries.
The LED light turns OFF when not needed to save battery
power. The previously stored information in the sensor will not
be affected or cancelled while you change the batteries.
MAINTENANCE AND CARE
• Avo id ext reme temperatures, vibration and shock.
• Clean t he sen sor with a soft, damp cloth.
Do not use solvents or scouring agents.
• Do not submerge the sensor case in water.
• Do not kink the 6 ft. sensor cable.
• Secu re the 6 ft . cable to avoid tripping hazards.
• Immediately remove all low powered batteries to avoid
leakage and damage.
• Opening the casings invalidates the warranty. Do not try to
repair the unit. Contact La Crosse Technology® for repairs.
SPECIFICATIONS
Transmission range: 200 feet (60.96 m) in open space
Water status (H20/DRY):
detects wet (H20) and dry (DRY)
conditions. Displays last rea ding on
LCD if probe is not connected.
Sensor battery power 2 x AAA Alkaline, IEC LR03, 1.5V
Battery life cycle: Approximately 24 months
TX71U-IT size: 5.23" H x 0.76" W x 1.44" D
D000.105 H20 Sensor size .26” H x 1.77" W x 1.17" D
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty
on this product against manufacturing defects in materials and
workmanship.
This limited warranty begins on the original date of purchase, is
valid only on products purchased and used in North America
and only to the original purchaser of this product. To receive
warranty service, the purchaser must contact La Crosse
Technology, Ltd for problem determination and service
proced ures . W arranty service can only be performed b y a La
Crosse Technology, Ltd authorized service center. The
origi nal dated b ill of sale must be presented upon request as
proof of purchase to La Crosse Technology, Ltd or La Crosse
Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product,
at our option and at no charge as stipulated herein, with new or
reconditioned parts or products if found to be defective during
the limited warranty period specified above. All replaced parts
and products become the property of La Crosse Technology,
Ltd and must be returned to La Crosse Technology, Ltd.
Replacement parts and products assume the remaining
original warranty, or ninety (90) days, whichever is longer. La
Crosse Technology, Ltd will pay all expenses for labor and
materials for all repairs covered by this warranty. If necessary
repairs are not covered by this warranty, or if a product is
examined which is not in need or repair, you will be charged for
the repairs or examination. The owner must pay any shipping
charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service
center. La Crosse Techno logy, Ltd will pay ground r eturn
shipping charges to the owner of the product to a USA address
only.
Your La Crosse Technology, Ltd warranty covers all defects in
material and workmanship with the follow ing spec i f ied
exceptions: (1) damage caused by accident, unreasonable use
or neglect (including the lack of reasonable and necessary
maintenance); (2) damage occurring during shipment (claims
must be presen ted to the car r ier ) ; (3 ) dama ge to, or
deteri oration of, any ac cess ory or dec orat ive surface; (4)
damage resulting from failure to follow instructions containe d in
your owner’s manual; (5) damage resulting from the
performance of repairs or alterations by someone other than
an authorized La Crosse Techn ology, Ltd authorized ser vice
center; (6) units used for other than home use (7) applications
and uses that this product was not intended or (8) the products
inability to receive a signal due to any source of interference..
This warranty covers only actual defects within the product
itself, and does not cover the cost of installation or removal
fr om a fixed installati on, nor mal set-up or adjustments, cl ai ms
based on misrepresentation by the seller or performance
variations resulting from installation-related circumstances.
Page 4
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME
LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE,
OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE
OPERATION OR MALFUNCTION OF THIS PRODUCT.
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL
PURPOSES OR FOR PUBLIC INFORM A T ION. TH IS
PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S
REACH.
This warranty gives you specific legal rights. You may also
have other rights specific to your State. Some States do not
allow the exclusion of consequential or incidental damages
therefore the a bove exc lusion of l i mitation may not apply to
you. For warranty work, technical support, or information,
This dev ice compl ies w ith part 15 of t he FCC rules. Operation
is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interfer ence r eceived,
including inter fer ence t hat m ay cau se undesired o peration.
Printed in China
LA CROSSE ALERTS™ PRODUCTS
For online product information:
www.lacrossetechnology.com/alerts
DISCLAIMERS
* Disclaimers: La Crosse Technology, LTD. (“La Crosse”)
provides various alert and monitoring services to aid users.
(1) Serv ice providers may char ge us ers f or alert s ervi ces.
Standard messaging and data rates apply and will be billed to
the custom er’s wireless acco unt. Customers may be unable to
receive text messaging or data ser v ice i n some area s due t o
unavailability of service. (2) La Crosse shall not be liable for
accuracy, usefulness or availability of data transmitted via the
service. Users are solely responsible for damages to persons
or prop erty by service use.
All rights reserved. This handbook must not be reproduced in
any form, even in excerpts, or duplicated or processed using
electronic, mechanical or chemical procedures without written
permission of the publisher.
This handbook may contain mistakes and printing errors. The
information in this handbook is regularly checked and
corrections made in the next issue.
We accept no liability for technical mistakes or printing errors,
or their consequences. All trademarks and patents are
acknowledged.