Kyocera FS-C8600DN, FS-C8650DN SERVICEBULLETINS 2MN 0004 C223

(Page.1/2)
Notes on Replacement of the Parts (Unification of the Operation Wire)
Model l:
FS-C8650DN, FS-C8600DN
No.
Old Part
No.
New Part
No.
Description
Q’
ty
Com
bi
pati­lity
Remarks
Old
New
Old
New
1
302MN46030
2MN46030
302MN46031
2MN46031
WIRE PANEL
1
1
X O *1
2
302MN94050
2MN94050
302MN94051
2MN94051
PARTS OPERATION UNIT SP
1
1
O
(*2) O (*2)
3
302MN46110
2MN46110
------------
+WIRE PANEL JOINT
1
-
X
-
Unified with the new No.1
Connect
Connect with the connector (YC1) on the operation panel PWB.
(Connecting part of the old wires (No.1 and No.3)
Connector YC1 on the panel PWB
Old WIRE PANEL (No.1)
Old WIRE PANEL JOINT (No.3)
Connect with the connector (YC1) on the operation panel PWB.
Service Bulletin Ref. No. 2MN-0004 (C223)
<Date> August 30, 2012
Topic
The WIRE PANEL JOINT (No.3) was abolished and unified into the new WIRE PANEL (No.1) for the easy wire alignment. Accordingly, some attention is required when installing the new operation unit (No.2) for service to the machine before this change. Therefore, please refer to [Field Measures] below.
<WIRE PANEL JOINT (No.3): Wire length is 85 mm> <Old WIRE PANEL (No.1): Wire length is 900 mm>
<New WIRE PANEL (No.1): Wire length is 1000 mm>
[Machine without the right upper cover]
"+" mark at the beginning of the part name indicates that it is a component part.
*1: If replacing the old WIRE PANEL (No.1) with the new WIRE (No.1) in the machine before the changes, please remove the
WIREPANEL JOINT (No.3). *2: If installing the old operation unit to the machine after the changes, please remove the unnecessary WIRE PANEL JOINT (No.3). If installing the new operation unit to the machine before the changes, please remove the WIRE PANEL JOINT (No.3) from the operation unit in the machine and reconnect it with the panel PWB (Connector YC1) in the new operation unit.
KYOCERA Document Solutions Europe
Technical Customer Service Division (TCSD)
(Page.2/2)
KMC’s Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure:
Please remove the WIRE PANEL JOINT (No.3) from the current operation unit attached in the machine and reconnect it with the panel PWB (Connector YC1) in the new operation unit when replacing the operation unit in the machine before this change.
FS-C8650DN
KDA
KDA 220VI
KDE
UTAX
KDAU
KDAS
KDKR
1102MN2US0
1102MN4US0
1102MN3NL0
1102MN3UT0
1102MN3AS0
1102MN3AX0
1102MN3KR0
NXW2700034
NXZ Next
NXX2700178
L4F Next
NXY2700010
L462800001
L47 Next
FS-C8600DN
KDE
UTAX
1102N13NL0
1102N13UT0
NY22700186
L4G2700001
Service Bulletin Ref. No. 2MN-0004 (C223)
<Date> August 30, 2012
Serial Nos. of the Affected Machines
KYOCERA Document Solutions Europe
Technical Customer Service Division (TCSD)
Loading...