Kyocera FS-C5150, FS-5250 SERVICEBULLETINS 2KT 0009 B411

s changed
from 2microA to 8microA.
579797
environment.
579336
implemented.
579995
Service Bulletin Ref. No.
Subject
(Page.1/1)
2KT-0009 (B411)
<Date> November 18, 2011
Firmware Upgrade (Engine: Ver. 006.002)
FS-C5150DN_FS-C5250DN_03.00.0020_(2011-11-04)
Model
FS-C5150DN, FS-C5250DN
Topic
The firmware was upgraded as follows.
Content of Changes
No. Item Details
Measures against the
1
color shift due to cleaning failure during calibration
Review of the drum
2
protection control
Due to the change of the drum protection control table above, conductive
Program No.
ENGINE 2KT_1000006002 9734 006.002 2011/9/16 005.002 FS-C5150DN
The color shift might occur if a cleaning failure occurred with the color adjustment reference pattern on the primary transfer belt. Therefore, this was corrected.
[Change] The cleaning bias to the cleaning fur brush during calibration wa
The drum protection control was reviewed and its control table was
changed in order to optimize the toner disposal at the normal operating
compound may adhere around the gap between the main charger roller and the drum, which causes white streaks in the drum circle interval if the machine was left for two hours or longer at high temperature and high humidity. Therefore, preventive control for the white streaks was
Check
SUM
Ver.
Status
Date
Current
Ver.
Remark
CTL FW
ENGINE
ENGINE
ENGINE
←←←← New upgrade
ENGINE 2KV_1000006002 A0FF 006.002 2011/9/16 005.002 FS-C5250DN
MAIN 2KV_3F00002005
Optional language KR 2KV_81KR001014
Optional language CN 2KV_81CN001012
Optional language
For the KM sales companies, it is possible to download the firmware at the download center on the ESDC.net. When upgrading the firmware or replacing a board, please upgrade all kinds of the firmware to the latest version at the same time.
2KV_81TW001012
- 002.005 2011/1/27 001.072
- 001.014
- 001.012
- 001.012
- - For KMKR
- - For KTST
- - For KMTW
FS-C5150DN FS-C5250DN
←←←← New upgrade
KMC’s Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure: Please upgrade the firmware when the problem described above arises.
Serial Nos. of the Affected Machines: Planned from the November 2011* production
*The above is the plan at the present moment. Please note that this information is subject to change.
European Service & Development Center (ESDC)