Kyocera FS-C5150, FS-C2026, FS-5250, FS-2126MFP ServiceBulletin 2KW-0026-B107 1

was
increased
.
Subject
(Revised issue 1)
Service Bulletin Ref. No.
2KW-0026 (B107)
<Date> March 8, 2012
Improvement of the Opening and Closing Performance of the Toner Container Shutter
(Page.1/3)
Model
This time, the description with (-->) was revised from the previous information.
<Number of changes: 2> The serial numbers of the affected models were added.
FS-C5150DN, FS-C5250DN, FS-C2026MFP, FS-C2126MFP
Topic
The following changes were made in order to secure the margin for opening and closing abilities for the toner container shutter.
Content of Changes
1. Change of the toner container holder section on the main unit side The tension of the SPRING JOINT SHUTTER was increased which is a component of the HOLDER JOINT ASSY in order to increase the fitting force for the joint between the toner container and the HOLDER JOINT on the main unit side.
2. Change of the toner container shutter
The shape of the SHUTTER CONTAINER was changed in order to reduce the backlash at the joint of the
SHUTTER CONTAINER and to secure the margin for opening and closing capabilities for the toner container shutter.
Toner container
A
HOLDER JOINT ASSY
A: Enlarged
SHUTTER CONTAINER
Component of the HOLDER JOINT ASSY: Tension of the SPRING JOINT SHUTTER
Thickened by 0.45 mm
KYOCERA MITA Europe B.V.
(Revised issue 1)
Service Bulletin Ref. No.
3. Distinction
A projection was applied to the SHUTTER CONTAINER so that the improved toner container can be easily recognized. Marking on SHUTTER CONTAINER
T: FS-C5150DN; V: FS-C2026MFP, FS-C2126MFP and FS-C5250DN
KMC’s Classification
Field Measure: Please refer to the service bulletin SB-2KW-0024-B081 for the corrective action in case that
Serial Nos. of the Affected Machines: Please refer to the table below.
Entire Stock Rework In-Field modification at next visit
the message “Toner container is improperly installed” appears after a new toner container was installed.
Projection
*No service part was registered due to this change.
In-Field modification by case No modification necessary
2KW-0026 (B107)
<Date> March 8, 2012
(Page.2/3)
KYOCERA MITA Europe B.V.