Kyocera FS-C5100, FS-5200, FS-5300, FS-5400 SERVICEBULLETINS 2HG 011

Service Bulletin
SB Number:
Subject:
SB 2HG-011
False toner empty detection
Creation Date: 23/06/2010
Phenomenon The message “Replace toner” may be displayed, while the toner container is not empty.
Cause Improper toner distribution to the developing unit.
Solution The following changes have been made:
1. The diameter of the spring wire has been changed from 0.3mm to 0.4mm.
2. The shape of the spring toner feed has been changed from compressed curling to circular cone type.
DV-570 (K, Y, M or C). Spring toner feed. Spring toner feed.
Old condition
Toner feed entrance.
Parts
No. Old Parts
No.
1 302HG93023
2HG93023
2 302HG93033
2HG93033
3 302HG93043
2HG93043
4 302HG93053
2HG93053
New Parts No.
302HG93024 2HG93024
302HG93034 2HG93034
302HG93044 2HG93044
302HG93054 2HG93054
New condition
Description Q’TY Interchange-
ability
Old New Old New
DV-570(K) 1 1 O O O
DV-570(Y) 1 1 O O O
DV-570(M) 1 1 O O O
DV-570(C) 1 1 O O O
SP
Classication
Field measure When the above mentioned phenomenon occurs, please replace the DV-570 (K, Y, M or C) with
KMIS Service Department, Kyocera Mita Europe A192 / SB 2HG-011
Entire stock rework
the latest type.
In-eld modication at next visit
Page 1 of 2
In-eld modication by case
X
No modication necessary
Service Bulletin
Serial numbers of affected machines
Type Serial number
FS-C5400DN June 2010 production/XAC0602151
The above mentioned changes have been applied to machines produced after the above mentioned production date/ serial number.
Serial numbers of affected units
Type Item number Serial number
DV-570(K) 302HG93024 WWR0608779
DV-570(Y) 302HG93034 WWS0608779
DV-570(M) 302HG93044 WWT0608785
DV-570(C) 302HG93054 WWV0608791
The above mentioned changes have been applied to units produced after the above mentioned serial numbers.