Kyocera FS-6025, FS-6030MFP Service Bulletin 2K3 018

Service Bulletin
SB Number:
Subject:
SB 2K3-018
Abnormal scan image (Added Spacer to adjust the ISU base
Creation Date: 07/03/2012
Phenomenon 1. Focus related abnormal images may appear when scanning. (See the images below)
2. An error may occur, when performing Maintenance mode U411 [Adjusting the scanner automatically] after installing the Service part ISU.
Details The height and warpage of the Base of the ISU, varies slightly depending on the Main body. In
this case the optical axis may shift and may be interrupted by the Reector. Under this condition, the LED light may be shifted to the Optical guide plate.
Solution Please install the Spacer to adjust the height of the Base of the ISU according to the procedure
on the following pages or the Leaet. The Spacer and Leaet are bundled with the Service part ISU.
White image at the leading edge
Vertical streaks at the leading edge
White image at the leading edge
Vertical streaks at the leading edge
Background at the middle of the image
Lateral white streaks at the middle of the image
KMIS Service Department, Kyocera Mita Europe B440 / SB 2K3-018
Page 1 of 6
Service Bulletin
Classication
Field measure 1. Please perform image adjustment with maintenance mode U411 [Adjusting the scanner
Parts
No. Old Parts
No.
1 302K993031
2K993031
2 302LK93081
2LK93081
Parts notes: The latest Parts image scanner, contains the following parts (Together with the leaet describing the image check and installation procedure of the spacers).
Poly slider washer_5.1X12X0.2T (2 pcs). Poly slider washer_5.2X16X0.5T (2 pcs).
Entire stock rework
automatically], after replacing the ISU with the latest type.
2. If the abnormal image occurs when scanning, after replacing the ISU with the latest type, please add the spacer (Poly slider washer) to the screw holes of the ISU.
New Parts No.
302K993032 2K993032
302LK93082 2LK93082
In-eld modication at next visit
Description Q’TY Interchange-
PARTS IMAGE SCANNER H ASSY SP
PARTS IMAGE SCANNER L SP1 1 X O FS-C8020MFP/
In-eld modication by case
X
ability
Old New Old New
1 1 X O FS-6025MFP/
No modication necessary
Applicable model(s)
6025MFP(B)/ 6030MFP
8025MFP
Connecting the Flat cable to replace the ISU
The Caution Leaet 2 (Containing installation instructions of the Spacers) has been bundled with the ISU Service part. PREVENT DAMAGE DUE TO STATIC ELECTRICITY, BY USING ANTI-STATIC BAND BEFORE PROCEEDING.
1. Hold the Flat cable at point (A) to insert it (This prevents pressure the the CCD unit).
2. Fasten the Screw after inserting the Flat cable.
Flat cable CCD unit
A
A
KMIS Service Department, Kyocera Mita Europe B440 / SB 2K3-018
Page 2 of 6
Loading...
+ 4 hidden pages