Service Bulletin Ref. No.
Subject
Model
(Installation target models of PF-470 and PF-471: FS-C8020MFP, FS-C8025MFP, FS-6025MFP, FS-6025MFP/B,
(Page.1/2)
2K3-0028 (C022)
<Date> January 24, 2012
(Permanent Measures) Measures against the Standard
Cassette Withdrawing Failure
FS-C8020MFP, FS-C8025MFP, FS-6025FP, FS-6025MFP/B,
FS-6030MFP, PF-470, PF-471
FS-6030MFP)
Topic
It was informed by the service bulletin SB-2K3-0024-B432 that the guide (No.5) was added as the measures against
the standard cassette withdrawing failure due to the stiffness.
This time, the following changes were made as the permanent measures.
Content of Changes
1) The shape of the cassette backside was changed so that the paper width cursor support point will not contact the
base edge protection material.
2) The guide (No.5) for the cassette CT-475/476(No.1 to 4) was abolished due to the change above.
<Backside of cassette>
cursor s
point boss
302K393171
1
2K393171
302K39K171
2
2K39K171
303NN93011
3
3NN93011
303NN9K011
4
3NN9K011
302K394900
5
2K394900
Old Part
No.
“+” at the head of the part name indicates that it is a component part.
*1: Standard cassette for main unit, first cassette of PF-471 and PF-470; *2: Second cassette of PF-470
Arm
New Part
No.
302K393172
2K393172
302K39K172
2K39K172
303NN93012
3NN93012
303NN9K012
3NN9K012
No.
----------
Ribs added
Ribs added
Description
CT-475 1 1
CT-475 (KR) 1 1
CT-476 1 1
CT-476 (KR) 1 1
+ PARTS GUIDE BOTTOM
CASSETTE ASSY SP
guide (No.5) >
ty
Old New Old New
O O
O O
O O
O O
1 -
X -
lity
Guide (No.5)
abolished
Remarks
*1
*1
*2
*2
Set of the guide,
screw and leaflet
European Service & Development Center (ESDC)
KYOCERA MITA Europe B.V.
Service Bulletin Ref. No.
KMC’s Classification Entire Stock Rework In-Field modification at next visit
Field Measure:
Please install the guide (No.5) if it is hard to withdraw the old type cassette.
(For more details on the phenomenon, please refer to the service bulletin SB-2K3-0024-B432.)
Serial Nos. of the Affected Machines:
PF-470/PF-471: Planned from the January 2012* production
Others: After using up the old stock
(Page.2/2)
2K3-0028 (C022)
<Date> January 24, 2012
In-Field modification by case No modification necessary
*The above is the plan at the present moment. Please note that this information is subject to change.