( ) NEW IPSWICH C
INSTALLATION INSTRUCTIONS
CABINET
K-97779T/K-97794T
·
Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based upon the
·
latest product information available at the time of publication. Kohler China. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and
·
warranty information-
consumer.
·
IPSWICH bathroom cabinet adopts E1 grade wood-based panel of high quality, and with further processing, its harmful emissions will be less than 1.5mg/L.
Turn off the water supply.
·
The pluming installation must comply with Water Supply
·
Regulations/Bye-laws, Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers. The installation should be carried out by a plumber. Before installation carefully inspect the new fixture for any
·
signs of damage.
please leave instructions for the
ORDERING INFORMATION
·
·
·
·
·
·
·
E1
1.5mg/L
-
This installation covers the following products in the NEW IPSWICH range:
NEW IPSWICH C Cabinet 600mm ....................K-97779T
NEW IPSWICH C Cabinet 800mm ....................K-97794T
SAFETY: WARNINGS
Kohler products are precision-engineered and should give continued superior and safe performance, provided:
1. They are installed, commissioned, operated and maintained in accordance with the recommendations given in this Manual.
2. Periodic attention is given, as necessary, to maintain the product in good functional order. Recommended guidelines are given in the section.
Carefully inspect the new fixture for any signs of damage.
When installing Kohler Products, manufacturers guidelines for power tool safety should be followed.
MAINTENANCE
600mm...........................K-97779T
800mm...........................
1.
2.
K-97794T
1244199-T01-A
-1-
215500
, 2014
Copyright Kohler China Ltd., 2014
Page 2
ROUGHING-IN
Reference Value
840
775
K-97794T
Cabinet 800mm
800mm
Kohler reserves the right to change marked dimensions without prior notice.
580
840
Fig.1
1
560
K-97779T
Cabinet 600mm
600mm
UNIT : mm
580
INSTALLATION
A. Install Washbasin Cabinet
Install the services. Hot (H) and Cold (C) inlets must be connected to the correct inlet pipes. Install the drain in accordance with the manufacturer's instructions. We suggest using P-trap drain. Connect P-trap pipe with washbasin drain.
CAUTION !
washbasin drain connections.
CAUTION !
connections for future plumbing maintenance.
NOTE
with isolating valves.
The hot and cold water supplies must be installed
Make sure a watertight seal exisits on all
Provide access to the plumbing
A.
(H) (C)
P
1244199-T01-A
Fig.2
2
-2-
Page 3
1. Screw out four adjustable feet (see Fig.3). Place the cabinet at a desired position in the bathroom, and then adjust the four adjustable feet to put the cabinet in place.
1. 4 3
Go up
2. Mark the wall through two holes at the corresponding
positions. As Fig 4.
Go down
Fig.3
3
2. 4
8
3. Dismount the washbasin cabinet and put aside. Drill holes at the marked position.
CAUTION!
Avoid the cables and pipes inner set when
drilling in the wall.
NOTE:
Different types of bolts are required for different decoration boards. Please apply suitable bolts and Plugs.
4. Insert the plugs into the wall.
5. Apply a washer to the screw before tighten it. Make sure
the washbasin cabinet has been fixed firmly on the wall.
1244199-T01-A
Fig.4
4
3.
4.
5. 8
-3-
Page 4
6. As illustrated in Fig.5, open the flap-down door and loosen the screws of the PVC basket . Remove the basket upwards.
6. 5
Fig.5
5
7. Install handle as illustrated in Fig.6.
8. Install the PVC basket as illustrated in Fig.7.
7. 6
Fig.6
6
8. 7
1244199-T01-A
Fig.7
7
-4-
Page 5
9. Adjust position of the adjustable shelf as shown in Fig.8.
9. 8
Loosen the clip.
Lift the shelf to remove it. Adjust position of the shelf support.
abc
Press down the shelf.
d
10. Adjust the hinge cover in 3 direction to make sure the door is level. As shown in Fig.9.
Tighten the clip.
e
Fig.8
8
10. 9
11. Place the hinge cover and plastic cover.
Install the Synthetic Top
Note: Please refer to the installation instructions of synthetic
top for its installation. To protect the cabinet from dampness, please apply silicone sealant where the synthetic top and the cabinet connect.
1244199-T01-A
Fig.9
9
11.
-5-
Page 6
Connect Drainage
1. Inwall drainage (P-Trap) Please install the drain assembly and faucet as shown. Please set the water supply and drainage position according to the suppliers instructions. You can put the pipe into the U Notch.
1. (P )
/U
Faucet
Supply Lines
Shut-off Valve
Drain Assembly
Fig.10
10
2. Floor drainage (S-Trap) Please install the drain assembly and faucet as shown. Please set the water supply and drainage position according to the suppliers instructions. You can put the pipe into the U Notch.
2. S
U
Faucet
Supply Lines
Shut-off Valve
Drain Assembly
Ripple Pipe
Outlet
Fig.11
11
1244199-T01-A
-6-
Page 7
USER MAINTENANCEUSER MAINTENANCE
Warning! Risk of product damage.
Many cleansers contain abrasive and chemical substance
1.
which is not suitable for cleaning stainless steel, enamel, plating or plastic products. You may use mild cleansers or soaps to clean the surfaces. Wipe any splashes of cleaner solutions from the surface with clean soft cloth.
2.
Maintain ventilation in the bathroom, and separate the dry area from the damp one if conditions permit. Try to open the door and windows of the bathroom and maintain good ventilation.
3.
Kohler bathroom cabinet are dealt with strict procedures for damp-proof, whose good damp-proof function ensures good performance even in bathroom of huge humidity. Yet do not splash and pour water directly on the bathroom cabinet. Make sure that the bathroom is not over damp and wipe any splashes from surfaces immediately.
4.
Maintenance of door board: Clean and wipe door board regularly, and wipe the condensation vapor with dry and soft cloth.
5.
Ensure that electrical connections for appliances such as head lamp is insulated wipe mirror surface with chamois regularly to guarantee the persistent excellent performance.
6. Please do not sit, lean or step on the basin cabinet.
1.
2.
3.
4.
5.
6.
7. If any fixtures caused by abnormal reasons, Kohler China can supply paid replacement for service parts caused by abnormal reasons as shown in the Service Parts Page in the limited duration of warranty.