Kohler VIA Series, K-20629T-BW, K-25254T-BW, K-20630T-BW, K-20649T-BW Installation Instructions Manual

...
ORDERING INFORMATION
VIA WH Toilet (HT100 TL IWT).........................K-20629T-BW
Includes Bowl.................................................K-19720T-W
Includes HYDRO-TOWER 100
Touchless In-Wall Tank..............K-6281T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet (HT200 PNE IWT) .....................K-20630T-BW
Includes Bowl.................................................K-19720T-W
In-Wall Tank .............................K-20007T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet ( HT300 PNE IWT) ....................K-20645T-BW
Includes Bowl.................................................K-19720T-W
In-Wall Tank .............................K-20010T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet (HT300 MEC IWT).....................K-20648T-BW
Includes Bowl.................................................K-19720T-W
Includes HYDRO-TOWER 300
In-Wall Tank W/ Frame ..............K-4179T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet (HT100 MEC IWT).....................K-20649T-BW
Includes Bowl.................................................K-19720T-W
Includes HYDRO-TOWER 100
In-Wall Tank W/ Frame ..............K-6284T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet (HT100 TL IWT).........................K-25254T-BW
Includes Bowl.................................................K-19720T-W
Includes HYDRO-TOWER 100
Touchless IWT W/ Bevel FP ....K-21298T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
VIA WH Toilet (HT100 PNE IWT) .....................K-25255T-BW
Includes Bowl.................................................K-19720T-W
In-Wall Tank With Frame .........K-22524T-VABW
Includes Quiet-Close Toilet Seat ....................K-4141T-2P
( 100 ) .....K-20629T-BW
............................................................K-19720T-W
100
......................K-6281T-VABW
.........................K-4141T-2P
( 200 ) ............K-20630T-BW
............................................................K-19720T-W
200
...........................K-20007T-VABW
.........................K-4141T-2P
( 300 ) ............K-20645T-BW
............................................................K-19720T-W
300
...........................K-20010T-VABW
.........................K-4141T-2P
( 300 ) ............K-20648T-BW
............................................................K-19720T-W
300
....................................K-4179T-VABW
.........................K-4141T-2P
( 100 ) ............K-20649T-BW
............................................................K-19720T-W
100
....................................K-6284T-VABW
.........................K-4141T-2P
( 100 ) .....K-25254T-BW
............................................................K-19720T-W
100
....................K-21298T-VABW
.........................K-4141T-2P
( 100 ) ............K-25255T-BW
............................................................K-19720T-W
100
...........................K-22524T-VABW
.........................K-4141T-2P
BEFORE YOU BEGIN
·
·
·
Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based upon the latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information-please leave instructions for the
consumer.
VIA
INSTALLATION INSTRUCTIONS
VITREOUS CHINA WALL-HUNG P-TRAP TOILET
K-20629T-BW/K-20630T-BW/K-20645T-BW/K-20648T-BW
K-20649T-BW/K-25254T-BW/K-25255T-BW
·
·
·
-
-1-
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
2 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410
8 256410
©©Copyright Kohler China Investment Co., Ltd. 2018
2018
1132463-T01-D
NOTES
·
·
·
·
·
·
·
·
Observe all local plumbing and building codes. Shut off the water supply. Seat post holes are on 140mm centers. Passageways is longer than 50mm. Ensure have the correct roughing-in dimensions.
. Be very careful while working with vitreous china products. Vitreous china can break or chip if the bolts or nuts are overtightened, or if carelessly handled. Carefully inspect the new bowl for any sign of damage.
See
Fig.#1
Fixture dimensions are nominal and conform to tolerances established by ASME Standards (A112.19.2-2013). This product complies with GB 25502-2017. Water Efficiency Grade 1.
·
·
·
·
·
·
·
·
140mm
50mm
1
·
·
ASME (A112.19.2-
2013) GB 25502-2017 1
TOOLS AND MATERIALS REQUIRED (Not supplied)
· 254mm adjustable wrench
Metal file (file cut) Tape measure Tubing cutter Level Hacksaw Putty knife Screwdriver Straight pipe coupling Connection packing
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
254mm
ROUGHING-IN
Unit: mm
:
Reference Value
Fig.#1
1
Kohler reserves the right to change marked dimensions without prior notice.
140
295
590
475
360
400
375
360
292
353
322
218
90
55
102
-2-
1132463-T01-D
-3-
1. INSTALL THE TANK
1) Turn the water supply off before installing the new toilet.
2) Install the concealed tank system in wall before decorating the wall.
3) Install the tank system per tank's installation instructions.
Note: Refer to installation instructions of in-wall tank for SKU of faceplate.
INSTALLATION
Fig.#2
2
1.
1)
2)
3)
2. SET THE SPACING OF THE BOWL After you install the tank, be careful to set the spacing of set aside the length for carrier studs and tighten nut. The bowl on wall according to the dimensions as shown. See Fig. #3.
2.
3
Fig.#3
3
355
320
Unit: mm
:
178
215
35
Nut
10
Carrier Stud
NOTE: Please reserve 10mm space for
the nut strictly according to the picture. Otherwise, it will greatly affect the loading capacity of the toilet.
10mm
1132463-T01-D
-4-
3. ATTACH CONNECTION PIPE
1) Attach inlet pipe which set aside the length to the
concealed tank.
2) Attach outlet pipe to the toilet.
3) You may apply some lubricant to help connect smoothly.
4) Please tilt the outlet pipe a little after it is installed to prevent water storage.
See Fig. #4.
See Fig.#5.
3.
1)
2)
3) 4
4) 5
Fig.#4
4
Fig.#5
5
Inlet
Outlet
1
4. INSTALL THE NEW TOILET
1) Install the accessory kit into the installing hole.
2) Place the new toilet on the wall through the carrier.
3) Use wrench to tighten accessories and level the toilet. Then finish fixation.
4) Insert the cap into installing hole. See Fig. #6.
4.
1)
2)
3)
4) 6
10
Fig.#6
6
1132463-T01-D
-5-
5. Apply sealant to make sure the bowl,s edge seals to the wall. See Fig. #7.
5. 7
Fig.#7
7
6. Install the toilet seat according to its installation instructions. 6.
0C
o
CONSUMER RESPONSIBILITIES
If you live in a hard water area, make certain that the holes in the toilet rim are kept clean to ensure proper bowl flushing. Toilet bowl cleaners should be used at least once a week. Use a long-handled brush to clean the rim holes, and to clean as far into the trap as possible to prevent mineral deposits from forming.
Most toilet bowl cleaners are not harmful to the vitreous china surface of the toilet bowl. Please follow the bowl cleaner manufacturers instructions carefully.
Do not use abrasive cleaners or solvents.
Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This damage can cause leakage and property damage.
Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine (calcium hypochlorite).
WARNING: Risk of property or product damage.
'
Please do not use hard materials (like scouring pad) to clean product surface, especially the product logo.
CAUTION:
CAUTION: Don t use any cement while installing the toilet.
WARNING: Risk of product damage.
Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement.
Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel. Do not bump the vitreous china with great force to prevent it from damaging and leaking. Do not use the product in the water below 0 C.
o
1132463-T01-D
-1-
HYDRO-TOWER 300 300
INSTALLATION INSTRUCTIONS
IN-WALL TANK
N
K-20009T-PNE/K-20009K-PNE/K-20010T-PNE/K-20010K-PNE
K-20010T-VLS/K-20010T-DNSW/K-20010T-DNW/K-20010T-VABW/K-20010T-RES
K-20011T-PNE/K-20011K-PNE/K-78076T-PNE/K-78076K-PNE
K-78077T-PNE/K-78077K-PNE/K-78077T-RES/K-78077T-ESS/K-78077T-VLS
K-78077T-VLSL/K-78077T-VL130/K-78077T-VL150/K-78078T-PNE/K-78078K-PNE
K-20341T-PNE/K-75890T-PNE/K-23055T-P E/K-23056T/K-23056TW
!
!
!
!
!
Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid product damage and installation inconvenience caused by inappropriate operation. All data contained is based upon the last product information available at the time of publication. Kohler Company reserves the right to implement changes of product characteristics, packaging and availability at any time without further notice. Do not apply erosive cleanser and solvent in the tank, which will damage tank spares and result in leakage in the tank. Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used. Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares. Kohler will not be responsible for any damage related to installation with spares not provided by Kohler. This product complies with GB26730-2011.
!
!
!
!
!
GB26730-2011
Ordering Information
HYDRO-TOWER 300 PNE IWT 2.6/4.0L ..................................................................................................................K-20009T-PNE
HYDRO-TOWER 300 PNE IWT 2.6/4.0L..................................................................................................................K-20009K-PNE
HYDRO-TOWER 300 PNE IWT 3/4.5.0L ..................................................................................................................K-20010T-PNE
HYDRO-TOWER 300 PNE IWT 3/4.5.0L..................................................................................................................K-20010K-PNE
HYDRO-TOWER 300 PN IWT W/ FRAME 3.5/5.0L(VEIL WH).................................................................................K-20010T-VLS
HYDRO-TOWER 300 PN IWT W/ FRAME 3.5/5.0L(ODEON WH) .......................................................................K-20010T-DNSW
HYDRO-TOWER 300 PN IWT W/ FRAME 3.5/5.0L(ODEON WH)..........................................................................K-20010T-DNW
HYDRO-TOWER 300 PN IWT W/ FRAME 3.5/5.0L(VIA WH) ...............................................................................K-20010T-VABW
HYDRO-TOWER 300 PN IWT W/ FRAME 3.5/5.0L(REVE WH) ..............................................................................K-20010T-RES
HYDRO-TOWER 300 PNE IWT 3.0/6.0L ..................................................................................................................K-20011T-PNE
HYDRO-TOWER 300 PNE IWT 3.0/6.0L..................................................................................................................K-20011K-PNE
HYDRO-TOWER 300 PNE IWT W/O FRAME 2.6/4.0L ............................................................................................K-78076T-PNE
HYDRO-TOWER 300 PNE IWT W/O FRAME 2.6/4.0L ............................................................................................K-78076K-PNE
HYDRO-TOWER 300 PNE IWT W/O FRAME 3 /4.5L ............................................................................................K-78077T-PNE
HYDRO-TOWER 300 PNE IWT W/O FRAME 3 /4.5L ............................................................................................K-78077K-PNE
3.5/5.0L HYDRO-TOWER 300 PNE IWT W/O FRAME(REVE WF)..........................................................................K-78077T-RES
3.5/5.0L HYDRO-TOWER 300 PNE IWT W/O FRAME (ESCALE WF) ....................................................................K-78077T-ESS
3.0/4.5L HYDRO-TOWER 300 PNE IWT W/O FRAME(VEIL WF) ............................................................................K-78077T-VLS
3.0/4.5L HYDRO-TOWER 300 PNE IWT W/O FRAME(VEIL WF) ..........................................................................K-78077T-VLSL
HYDRO-TOWER 300 PNE IWT W/O FRAME 3.0/4.5L(VEIL WF HC130) ............................................................K-78077T-VL130
HYDRO-TOWER 300 PNE IWT W/O FRAME 3.0/4.5L(VEIL WF HC150) ............................................................K-78077T-VL150
HYDRO-TOWER 300 PNE IWT W/O FRAME 3.0/6.0L ............................................................................................K-78078T-PNE
HYDRO-TOWER 300 PNE IWT W/O FRAME 3.0/6.0L ............................................................................................K-78078K-PNE
PEBBLE Pneumatic In-Wall Tank Faceplate (Not Supplied).....................................................................................K-20341T-PNE
LYNK Pneumatic Faceplate (Not Supplied) ..............................................................................................................K-75890T-PNE
Modern Life Small Faceplate (Not Supplied).............................................................................................................K-23055T-PNE
BEAM Sensor Faceplate (Not Supplied)............................................................................................................................K-23056T
BEAM Sensor Faceplate (Not Supplied) ........................................................................................................................K-23056TW
.0 .0
BEFORE YOU BEGINBEFORE YOU BEGIN
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,
JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
( ) 158 200436
©©Copyright Kohler China Investment Co., Ltd. 2018
2018
1288805-T01-B
-2-
!
!
Design And Installation Concept Of In-wall Tank
!
!
Installation of in-wall tank is much easier and nice-looking comparative to that of traditional tank. Meanwhile, the space layout will be more reasonable due to the application of in-wall tank pipes and connectors. The most remarkable advantage of in-wall tank is that the installation will never be limited to certain area, and can be installed wherever as you wish, which will make the bathroom layout more reasonable and nice-looking, and make good use of every inch of the bathroom space.
!
!
!
!
!
Function Explanation
!
!
!
!
!
Anti flow-backwards Adjustment of inlet water level Adjustment of flushing volume Single/double gear Assemble, disassemble and maintenance can be done without tools.
flushing
300 ,2.6/4.0L ...................................................................................................................K-20009T-PNE
300 ,2.6/4.0L ...................................................................................................................K-20009K-PNE
300 ,3.0/4.5L ...................................................................................................................K-20010T-PNE
300 ,3.0/4.5L ...................................................................................................................K-20010K-PNE
300 ,3.5/5.0L( ) ...................................................................................................K-20010T-VLS
300 ,3.5/5.0L( )............................................................................................K-20010T-DNSW
300 ,3.5/5.0L( )..............................................................................................K-20010T-DNW
300 ,3.5/5.0L( ) ...............................................................................................K-20010T-VABW
300 ,3.5/5.0L( )...................................................................................................K-20010T-RES
300 ,3.0/6.0L ...................................................................................................................K-20011T-PNE
300 ,3.0/6.0L ...................................................................................................................K-20011K-PNE
300 ,2.6/4.0L( ) ...........................................................................................K-78076T-PNE
300 ,2.6/4.0L( ) ...........................................................................................K-78076K-PNE
300 ,3.0/4.5L( ) ...........................................................................................K-78077T-PNE
300 ,3.0/4.5L( ) ...........................................................................................K-78077K-PNE
3.5/5.0 300 ( ) .....................................................................................K-78077T-RES
3.5/5.0 300 ( ) ..............................................................................K-78077T-ESS
3.0/4.5 300 ( )......................................................................................K-78077T-VLS
3.0/4.5 300 ( )....................................................................................K-78077T-VLSL
3.0/4.5 300 ( HC130) .......................................................................K-78077T-VL130
3.0/4.5 300 ( HC150) .......................................................................K-78077T-VL150
300 ,3.0/6.0L( ) ...........................................................................................K-78078T-PNE
300 ,3.0/6.0L( ) ...........................................................................................K-78078K-PNE
( )( )........................................................................................................................K-20341T-PNE
( )..................................................................................................................................K-75890T-PNE
( ).........................................................................................................................................K-23055T-PNE
( )...................................................................................................................................K-23056T
( )................................................................................................................................K-23056TW
Advantages Of In-wall Tank
!
!
!
!
!
!
!
!
Made of macromolecular materials that prevents corrison and leaking.
Will not affect the structure of the wall and provides excellent sound insulation. Easy installation and time efficient.
.
.
Clean, garbage free, and space .
Advanced water tank fitting, which makes possible the adjustment of the water discharge and double flush.
Extra-thin shell of the tank helps to save a lot of space and fit for any walls.
Do not need to prepare any other spareparts Easy maintenance and servicing
saving
1288805-T01-B
-3-
SPECIFICATIONS
Liter per flushing
Temperature
Water Supply
Environmental temperature: 1 ~55 Water temperature: 1 ~45
°C °C,
°C °C
°C °C
°C °C
1 ~55
1 ~45
Min water supply: 0.02MPa (dynamic pressure) Max
water supply: 0.74MPa (static pressure)
0.02MPa ( )
0.74MPa ( )
Full flushing volume: Half flushing volume:
6.0L
3.0L
6.0L
3.0L
Full flushing volume: 5.0 Half flushing volume:
5.0L
3.5L
L
3.5L
K-20010T-PNE K-20010K-PNE K-78077T-PNE K-78077K-PNE K-78077T-VLS K-78077T-VLSL K-78077T-VL130 K-78077T-VL150
K-20011T-PNE K-20011K-PNE K-78078T-PNE K-78078K-PNE
K-20010T-VLS K-20010T-DNSW K-20010T-DNW K-20010T-VABW K-20010T-RES K-78077T-RES K-78077T-ESS
Full flushing volume: 4.5L Half flushing volume: 3.0L
4.5L
3.0L
K-20009T-PNE K-20009K-PNE K-78076T-PNE K-78076K-PNE
Full flushing volume: 4.0L Half flushing volume: 2.6L
4.0L
2.6L
RECOMMENDES TOOLS AND MATERIALSRECOMMENDES TOOLS AND MATERIALS
!
!
!
!
!
!
!
!
!
!
!
!
!
Open end/adjustable wrenches Allen wrench Knife File Hacksaw Masonry Level Screw driver Insulation tape Tape measure Seal tape Bushing Lubricant
!
!
!
!
!
!
!
!
!
!
!
!
!
/
!
!
!
!
!
!
!
!
1288805-T01-B
ROUGHING-IN
UNIT: mm
Reference Value
K-20009T-PNE/K-20009K-PNE/K-20010T-PNE/K-20010K-PNE/K-20010T-VLS/
K-20010T-DNSW/K-20010T-DNW/K-20010T-VABW/K-20010T-RES/K-20011T-PNE/K-20011K-PNE
-4-
478 3
1098 4
Height Suggested / 1150
100 3
52~230
205 3
681 4
230 3
180 3
90 0.5
45~95
35 2
269 5
1066 4
1048 4
88 2
438 3
90~142
Air hose
Finished Floor
18~62
Air hose
Air hose
Pinch plate
Suggested faceplate
installation area
R1000mm
Suggested faceplate
installation area
R1000mm
Installed with
K-20341T-PNE
K-20341T-PNE
Method one:
Press from front
Method two:
Remote plate installation
Method three:
Remote installation of mask
K-78078T-PNE/K-78078K-PNE
722~792
604~674
(195~265)
373 2
88 2
478 3
440 3
18~62
Installed with K-20341T-PNE
K-20341T-PNE
Method one:
Press from front
Method two:
Remote plate installation
Method three:
Remote installation of mask
60 1
Air hose
Air hose
Air hose
Pinch plate
Suggested faceplate
installation area
R1000mm
Suggested faceplate
installation area
R1000mm
Finished Floor
Height to floor is decided by bowl.