Installation Guide
Bath Media Module
K-175
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de M corresponden a México
(Ej. K-12345M)
Français, page ″Français-1″
Español, página ″Español-1″
1093174-2-C
JOBNAME: No Job Name PAGE: 2 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
IMPORTANT INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Connect only to circuits protected by a Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Grounding is required. The unit
should be installed and grounded by a qualified service representative.
WARNING: Risk of electric shock. A licensed electrician should route all electrical wiring.
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
CAUTION: Risk of electric shock or product damage. Make sure the power cord is unplugged
before removing the access covers.
CAUTION: Risk of product damage. The media module is rated to operate in temperatures up to
104°F (40°C). Do not install in any location where the temperature may exceed 104°F (40°C).
NOTICE: Follow all plumbing, electrical, and building codes.
NOTICE: Provide generous, unrestricted service access to the media module. Provide access for
servicing. This access must be located immediately next to the media module. Refer to the roughing in
information.
FCC and IC Compliance
The term ″IC:″ before the certification/registration number only signifies that the Industry Canada
technical specifications were met.
Contains:
Kohler Company
Model #: 1070734
IC: 4554A-KOHLER044
FCC ID: N82-KOHLER004
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the
device.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired
operation.
NOTE:
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC and IC Radiation Exposure Statement for Mobile Devices
This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled
1093174-2-C2Kohler Co.
JOBNAME: No Job Name PAGE: 3 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
FCC and IC Compliance (cont.)
environment. This equipment should be installed and operated with a minimum distance of 7-7/8″ (20 cm)
between the radiator and your body. The transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Kohler Co.31093174-2-C
JOBNAME: No Job Name PAGE: 4 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
Specifications
Interface
Ambient TemperatureMax 125°F (52°C)
Maximum Relative Humidity100% condensing (External surface only)
Digital Interface Cable Length (supplied
with digital interface)
Media Module
Ambient TemperatureMax 104°F (40°C)
Maximum Relative Humidity95% non-condensing
Electrical Service100-240 V, 50/60 Hz, 2.0-0.83 A
Media Module100-240 V, 50/60 Hz, 2.0-0.83 A
Valve Cable Length (supplied)30 ft (9.14 m)
Line-in Cable Length5.6 ft (1.71 m)
Ethernet Cable Length30 ft (9.14 m)
30 ft (9.14 m)
Tools and Materials
LevelPencil
ScrewdriversHammerDrill
Plus:
• 1" Hole Saw
Measuring
Tape
1093174-2-C4Kohler Co.
JOBNAME: No Job Name PAGE: 5 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
30' (9.1 m)
Valve Cable
(Included)
10-11/16"
(27.1 cm)
5' 7" (1.7 m)
Line In Cable
30' (9.1 m)
Ethernet Cable
K-10609-D Accessory Cable Kit
Available Separately
19-3/16"
(48.7 cm)
36-1/4"
(92.1 cm)
20-1/2"
(52.1 cm)
21-5/8" (54.9 cm)
11/16"
(1.7 cm)
13" (33 cm) to
19" (48.3 cm)
2-5/16"
(5.9 cm)
2-3/4"
(7 cm)
7/16"
(1.1 cm)
Roughing-In
Before You Begin
Observe all local plumbing, building, and electrical codes.
Read these instructions and determine all required components along with their installation
locations before beginning this installation.
This manual covers horizontal installation under the bath surround. An access panel must be
provided for servicing.
The media module may also be mounted horizontally under the floor joists. If mounting under the
floor, the unit must not be enclosed.
A licensed electrician should install a 15 A 120 V GFCI electrical outlet, within the stud framing, in
close proximity to the media module.
If possible, install the electrical outlet prior to installing the media box.
This media module complies with UL, CSA, and FCC.
To play your personal music files, you must have one of the following music servers on your
personal computer: Microsoft
Musicmatch®Jukebox, or Firefly Media Server. For information regarding configuring your music
server, refer to the User Interface User Manual.
For best internet music performance, your computer must have a high speed internet connection.
Kohler Co. reserves the right to make revisions in the design of our products without notice, as
specified in the Price Book.
JOBNAME: No Job Name PAGE: 6 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
Digital Interface
False Wall
24" (61 cm) Min
36" (91.4 cm) Max
Fill Spout
Rear Access
Panel
Transducers
Overflow Location (LH Shown)
Media Module
Installation Overview
34" (86.4 cm)
to Knob
Outlet
4" (10.2 cm)
10"
(25.4 cm)
34" (86.4 cm)
to Knob
Front Access Panel
Digital Mixing Valve
3/4" (1.9 cm)
For best results, follow the recommended installation sequence below. Refer to content in this guide as well
as the Installation Guides packed with each component of your bathing system.
NOTE: Illustration above shows a typical installation with the preferred installation locations for the
digital interface, media module and the digital mixing valve (optional).
Recommended Installation Sequence
Determine the installation location for the media module, and digital mixing valve (if used).
Frame the island for the bath. Provide a properly dimensioned stud pocket for the media module
(required) and the digital mixing valve (optional).
Determine the location for the access panels (required) for servicing the bath transducers, media
module, and digital mixing valve (if used). Plan the island construction accordingly.
Install the island deck. Use the cut-out templates supplied with the bath when preparing the deck.
Frame the false wall for the digital interface.
Route all plumbing to include: supply lines (spout and handshower), drain line, and valve (if
applicable).
Install the electrical outlet(s) in close proximity to the media module and valve (optional)
installation location(s).
Route the Ethernet cable to a router, if applicable.
Route the digital interface cable to the media module.
Finish the false wall.
Install the digital interface and media module. Follow the installation instructions packed with each
product.
Install the bath and drain.
Connect all cables.
Finish the island walls and install the front and rear access panels.
1093174-2-C6Kohler Co.
JOBNAME: No Job Name PAGE: 7 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
Digital Mixing Valve
(Optional)
AC Power
Audio
Source
Line In Cable
Media Module
AC Power
ComputerInternet
Router
Ethernet Cable
Below Water
Transducer Cables
Above Water
Transducer Cable
Level Sensor
Digital
Interface
Cable
Chromatherapy
Lighting Cables
Bath
1. Determine Components
The media module controls the digital mixing valve, transducers, ″Smart Fill″ level sensor, chroma lighting,
and music via the digital interface.
Cables are available for connecting audio (line in) and Ethernet to the media module.
Note: Wireless Ethernet is an option with the media module. However, a wired Ethernet connection is
recommended.
Determine all required components along with their installation locations before beginning the
media module installation.
Refer to the installation guides packed with each product for specific installation needs.
Kohler Co.71093174-2-C
JOBNAME: No Job Name PAGE: 8 SESS: 17 OUTPUT: Thu Jul 17 13:54:19 2008
20-1/2"
(52.1 cm)
2. Prepare the Site
CAUTION: Risk of product damage. The media module is rated to operate in temperatures up to
104°F (40°C). Do not install in any location where the temperature may exceed 104°F (40°C).
2-5/8" (6.7 cm) to
2-7/8" (7.3 cm)
Pencil
13" (33 cm) to
19" (48.3 cm)
Outlet
Media Module
(not installed)
Drip Loop
The media module is designed to fit within a 13” (33 cm) to 19” (48.3 cm) wide 2x4 stud cavity. The
cavity should be free of cross bracing and insulation.
Brackets should be positioned 20-1/2″ (52.1 cm) apart. Allow enough room to one side of the media
module to accommodate the electrical outlet installation and power cord connection.
Measure 2-5/8″ (6.7 cm) to 2-7/8″ (7.3 cm) in from the stud face to determine the bracket placement.
Mark the bracket locations with a pencil.
Install a 15 A 120 V GFCI electrical outlet within the stud framing, in close proximity to the media
module.
If used, run the Ethernet cable to the media module installation site.
1093174-2-C8Kohler Co.