IMPORTANT! When using this unit, basic precautions should always be followed.
WARNING: Risk of personal injury. If you become uncomfortable while taking a steam bath, you
should turn off the steam, cool off with the shower, open the door, or exit the unit. WARNING: Risk of personal injury. A steam bath can put undue stress on the body, as does any
hot bath, shower, or sauna. Therefore, the steam bath may not be suitable for use if you are pregnant, have a heart condition, have high blood pressure, have circulatory problems, are under the influence of alcohol, are taking drugs or are under the care of a physician.
WARNING: Risk of personal injury. DO NOT consume alcoholic beverages or take medications or drugs prior to or when using the steam bath. Alcohol and drugs affect mental judgement and inhibit bodily functions such as heartbeat and respiration, resulting in potentially dangerous effects.
WARNING: Risk of injury to children. Do not allow children to use this unit unless they are closely supervised at all times. The steam generator is not designed to be used by children.
WARNING: Risk of scalding. Do not touch the steam head during operation. The steam head is hot during operation.
WARNING: Risk of personal injury or property damage. Avoid coming in contact with the water tank and/or steam discharge line while the generator is operating or shortly after shutdown. Wear eye protection and protective clothing when servicing the steam generator. The steam generator operates at high temperatures, which may result in personal injury or property damage.
NOTICE: Use this unit only for its intended use as denoted in this manual. DO NOT use attachments not recommended by Kohler Co.
1069332-5-C 2 Kohler Co.
Operating Your Steam Generator
NOTE: Refer to the instructions packed with your digital user interface and media module.
Normal Operation
GEN TESTLED is blinking green once every second (one second ON and one second OFF).TEMP SENSORLED is blinking green once every second (one second ON and one second OFF).DATA LINK″ LED is blinking green once every second (one second ON and one second OFF).
Abnormal Operation (see the Troubleshooting Procedures for more information)
GEN TESTLED is OFF, ON flashing red, ON solid green, or ON solid red.TEMP SENSORLED is OFF, ON flashing red, ON solid green, or ON solid red.DATA LINK″ LED is OFF, ON flashing red, ON solid green, or ON solid red.
The Power Clean Function
WARNING: Risk of personal injury. Stay out of the showering area when the power clean function is activated.
NOTICE: Users will be automatically reminded to use power clean after 600 minutes of steam generator use. The steam generator may be run three times before the power clean function must be run. Failure to initiate power clean after the third reminder will result in the system locking. Power clean must then be run in order to resume steam operation.
NOTE: When the power clean function is activated, water will typically discharge from the steam head.
Care and Cleaning
For best results, keep the following in mind when caring for your KOHLER product:
Always test your cleaning solution on an inconspicuous area before applying to the entire surface.
Wipe surfaces clean and rinse completely with water immediately after applying cleaner. Rinse and dry any overspray that lands on nearby surfaces.
Do not allow cleaners to soak on surfaces.
Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring pad to clean surfaces.
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care & Cleaning information, call 1-800-456-4537.
Kohler Co. 3 1069332-5-C
Warranty
KOHLER Steam Generator THREE-YEAR LIMITED WARRANTY
Kohler steam generator units manufactured after September 15, 2001, are warranted to the original consumer purchaser to be free of manufacturing defects in material and workmanship during normal residential usage for three (3) years from the date of installation. This warranty only applies to KOHLER steam generator units installed in the United States of America, Canada or Mexico (North America).
If a defect is found in normal residential usage, Kohler Co. will, at its election, repair or replace the unit, or make appropriate adjustment. Damage caused by accident, misuse or abuse is not covered by this warranty. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, removal charges, installation, or other consequential costs. In no event shall the liability of Kohler Co. exceed the purchase price of the unit.
If this unit is used commercially or installed outside of North America, Kohler Co. warrants the unit to be free from defects in material and workmanship for one (1) year from the date of installation with all other terms of this warranty applying except duration.
To obtain warranty service contact Kohler Co., either through your Dealer, Plumbing Contractor, Home Center or E-tailer or by writing Kohler Co., Attn: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico.
KOHLER CO. AND/OR SELLER ARE PROVIDING THESE WARRANTIES IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights, which vary from state/providence to state/providence.
This is Kohler Co.’s exclusive written warranty.
Troubleshooting
This troubleshooting guide is for general aid only. For service and installation issues and concerns, call 1-800-4-KOHLER.
Symptoms Probable Causes Recommended Action
1. Error 0140 is displayed. A. Tank water level is too low
(green status light on generator is on).
B. Tank temperature limit has been
exceeded (green status light on generator is off).
C. Internal generator components
are not functioning properly.
2. Error 0120 is displayed. A. The temperature in the steam
room has exceeded the maximum allowable level.
A. Inspect the water inlet screen and
clean if necessary. Ensure the water supply valve is on and that water is being supplied to the generator.
B. Call the Customer Care Center
using the information provided on the back page of this manual.
C. Call the Customer Care Center
using the information provided on the back page of this manual.
A1. Reset power to the generator and
ventilate the steam room to remove excess heat.
A2. Relocate the temperature sensor
away from steamhead or other heat source.
A3. Call the Customer Care Center
using the information provided on the back page of this manual.
1069332-5-C 4 Kohler Co.
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
3. Error 0104 is displayed. A. Temperature sensor not
A. Connect the temperature sensor.
connected.
B. Temperature sensor is damaged. B. Call the Customer Care Center
using the information provided on the back page of this manual.
4. Error 0408 is displayed. A. A communication error has
occurred.
5. Lights on the adapter are
off.
A. Inadequate power is supplied to
the generator (green status light on generator is off).
A. Perform a system reset on the user
interface.
A. Provide proper power to the
generator. If necessary use the provided test kit to ensure the generator is working properly.
B. The user interface is not
receiving power from the generator (green status light on
B. Use the provided test kit and
instructions to identify the source of the problem.
the generator is on).
6. ″GEN TESTlight is
blinking red.
C. The user interface is damaged
(green status light on the generator is on).
A. An error has occurred with the
steam generator.
C. Call the Customer Care Center
using the information provided on the back page of this manual.
A. Check the error code on the user
interface. See the corresponding error code in this document.
7. ″TEMP SENSORlight is
blinking red.
A. The temperature sensor is not
connected.
B. The temperature sensor is
damaged.
A. Connect the temperature sensor.
B. Call the Customer Care Center
using the information provided on the back page of this manual.
8. ″DATA LINKlight is
blinking red.
A. A connection to the media
module has not yet been
A. Wait for the connection to be made.
established.
B. A connection to the media
module cannot be established.
B. Remove and reattach the cable that
connects the adapter to the media module. Inspect cable for damage and replace if necessary.
C. An error has occurred. C1. Check the error code on the user
interface. See the corresponding error code in this document.
C2. Reset power to the generator and
media module.
C3. Perform a system reset on the user
interface.
9. Steam menu disappears
after requesting steam.
A. Cables between the generator(s)
and adapter are installed incorrectly.
A1. Reinstall the black and/or silver
cable(s) between the steam generator(s) and adapter per the instructions in the installation guide.
A2. Call the Customer Care Center
using the information provided on the back page of this manual.
10. Display does not show
steam function.
A. Inadequate power is supplied to
the generator (green status light on generator is off).
A1. Provide proper power to the
generator. Use the provided test kit, if necessary, to ensure the generator is working properly.
A2. Call the Customer Care Center
using the information provided on the back page of this manual.
Kohler Co. 5 1069332-5-C
Troubleshooting (cont.)
Symptoms Probable Causes Recommended Action
B. The adaptor is damaged (green
status light on generator is on).
B1. Use the provided test kit and
instructions to identify the source of the problem.
B2. Call the Customer Care Center
using the information provided on the back page of this manual.
11. Water from steam head. A. Normal operation. A1. A small amount of water
discharged from the steamhead just before, during, and just after steam use is normal.
A2. Water discharge from the steam
head during the Power Clean cycle is normal.
B. Water supply lines are
connected incorrectly.
B. Review the generator installation
guide and reinstall the lines at the proper locations.
C. Internal generator components
are not functioning properly.
C. Turn off water supply to the
generator. If possible, drain the tank. Slowly open the water supply valve to refill the generator.
C2. Call the Customer Care Center
using the information provided on the back page of this manual.
12. No steam after 5 minutes
of pressing power.
A. An error has occurred. A. Check the User Interface for error
messages. If an error message appears, see the appropriate error message troubleshooting.
B. The temperature setpoint has
already been reached.
B. Confirm the temperature setpoint is
greater than the current steam room temperature. Increase the temperature setpoint if desired.
C. Inadequate power is supplied to
the generator (green status light on generator is off).
C1. Provide proper power to the
generator. If necessary use the provided test kit to ensure the generator is working properly.
C2. Call the Customer Care Center
using the information provided on the back page of this manual.
D. Cables between the generator(s)
and adapter are installed incorrectly.
D. Reinstall the black and/or silver
cable(s) between the steam generator(s) and adapter per the instructions in the installation guide.
E. Steam line or steam head is
blocked.
E. Check the steam head and steam
line for blockages. Repair as necessary.
F. Generator is damaged. F1. Use the provided test kit to check
generator function.
F2. Call the Customer Care Center
using the information provided on the back page of this manual.
13. Steam stopped. A. An error has occurred. A. Check the User Interface for error
messages. If an error message appears, see the appropriate error message troubleshooting.
B. The session time limit was met
or the temperature setpoint was met.
B. Restart the session timer or increase
the temperature setpoint to restart steam.
1069332-5-C 6 Kohler Co.
1070455
Adapter
1047578
Gasket
1124237**
Housing
97222
O-Ring
97222
O-Ring
1128106**
Steam Head
1124220
Cable, Straight-Through [72" (182.9 cm)]
1068289
Harness
1124218
Coupler
1064359
Sensor
1124221
Data Cable, Crossover [10" (25.4 cm)]
1124219
Cable, Straight-Through [10" (25.4 cm)]
**Finish/color code must be specified when ordering
Service Parts
1069332-5-C 7 Kohler Co.
Guide du propriétaire
Générateur de vapeur et kit de contrôle
Information importante de sécurité
IMPORTANT! Des précautions de base devraient toujours être observées lors de l’utilisation de cette unité.
AVERTISSEMENT: Risque de blessures corporelles. Si un malaise survient lors du bain de vapeur,
arrêter la vapeur, se refroidir, ouvrir la porte ou sortir de l’unité. AVERTISSEMENT: Risque de blessures corporelles. Le bain de vapeur peut infliger de la fatigue
au corps, de même façon que tout bain chaud, douche, ou sauna. Par conséquent, la bain de vapeur n’est pas conseillé aux femmes enceintes, aux personnes souffrant de maladies cardiaques, d’hypertension, de problèmes de circulation, ou sous l’emprise d’alcool, de drogues ou sous traitement médical.
AVERTISSEMENT: Risque de blessures corporelles. NE PAS consommer d’alcool ou de médicaments ni de drogues, avant ou pendant l’utilisation du bain de vapeur. L’alcool et les drogues peuvent affecter les facultés mentales et inhiber certaines fonctions corporelles telles que le battement de coeur et la respiration, entraînant des effets potentiellement dangeureux.
AVERTISSEMENT: Risque de blessure aux enfants. Ne pas permettre aux enfants d’utiliser l’unité sans surveillance à tout moment. Le générateur de vapeur n’est pas conçu pour les enfants.
AVERTISSEMENT: Risque de brûlures. Ne pas toucher la tête de vapeur pendant le fonctionnement. La tête de vapeur est chaude durant l’opération.
AVERTISSEMENT: Risque de blessures ou d’endommagement du produit. Éviter de toucher le réservoir d’eau et/ou le tuyau d’évacuation de vapeur pendant l’opération du générateur ou juste après son arrêt. Utiliser des lunettes et des vêtements de protection pendant l’entretien du générateur de vapeur. Le générateur de vapeur opère à hautes températures, ce qui pourrait résulter en blessures ou endommagement de propriété.
AVIS: N’utiliser cette unité que pour l’usage destiné tel qu’indiqué dans ce manuel. NE PAS utiliser des dispositifs de fixation non recommandés par la Kohler Co.