DISTRIBUTED BY:
WORLD WIDE DISTRIBUTION SINCE
1972
KNIGHT, INC• A UNIT OF IDEX CORPORATION
20531 C
RESCENTBAYDRIVE
, L
AKEFOREST
, CA 92630 USA
T
OLLFREE
(800)854-3764 • (949)595-4800
FAX
(949) 595-4801
8111
TECHNOLOGY DR
., N.E.,
COVINGTON, GEORGIA
30014
USA
PHONE
(800)241-7789
FAX
(770) 787-1155
2880
ARGENTIA RD
UNIT
6.
MISSISSAUGA, ONTARIO
L
5N7X8
CANADA
PHONE
(905)542-2333
FAX
(905) 542-1536
15
BRUNEL CENTRE
,
NEWTON RD
.
CRAWLEY, WEST SUSSEX
RH
10 2
UB ENGLAND
PHONE
(44)1293-615570
FAX
(44)1293-615585
UNIT
28, 317-321
WOODPARK RD
.
SMITHFIELD, N.S.W
.
2164
AUSTRALIA
PHONE
61.2.9725.2588
FAX
61.2.9725.2025
68
MARSSTEDEN
7547
TD ENSCHEDE
,
THE NETHERLANDS
PHONE
+31 53 428 5800
FAX
+31 53 428 5809
KNIGHT LIMITED WARRANTY
All Knight controls and pump systems are warranted against defects in material and workmanship for a period of ONE YEAR. All Electronic Control Boards have a TWO YEAR warranty. Warranty applies only to the replacement or
repair of such parts when returned to the factory with a KRA number, freight prepaid and found to be defective upon factory inspection. Rubber and synthetic rubber parts such as "O" rings, diaphragms, squeeze tubing and gaskets
are considered expendable and are not covered under warranty. Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment. Product abuse or misuse voids warranty.
For information on the complete line of Knight equipment call the sales office nearest you.
MICRO PRO II — 5 /99 KNIGHT, INC.
Micro Pro II
MPII CONCENTRATION CURVE
Model Part No. Description
MPII-200L 7162700 Liquid Detergent and Rinse
Control
MPII-200D 7162705 Dry Detergent and Rinse
Control System with (1)
KP-500 Pump for Rinse
and (1) S-24 Solenoid for
Detergent
MPII-300L 7162710 Liquid Detergent, Rinse and
Sanitizer Control with (3)
KP-500 Pumps
MPII-300D 7162715 Dry Detergent, Rinse and
Sanitizer Control with (2)
KP-500 Pumps and (1)
S-24 Solenoid
The Micro Pro II warewash systems provide the ultimate in versatility and convenience. The tilt front and cover
makes setting and servicing the unit quick and easy. Having choices of probe/probeless operation, high and low
range concentration settings, rinse delay, rinse limit, dry detergent, liquid detergent, and sanitizer pumps makes the
Micro Pro II the universal dispenser. Mount it on the wall or on top of the machine by rotating the pumps and adding
the two suction cup feet provided.
SLIDE SWITCH SETTINGS
• Probe/Probeless Switch: Allows you to select operation
with or without a probe.
• Door/Conveyor Switch: Used if operating in probeless
mode.
• Low/High Range Switch: Used if operating in probe
mode. Selects concentration ranges.
• Low/High Audio Switch: Sets the alarm volume.
• Sani w/detergent / Sani w/rinse: used to activate the
Sani Pump with the detergent or rinse pump.
• On/Off Rinse Limit Switch: When on, stops the rinse
pump after 30 seconds.
• Delay Off/3 Sec.: Selects rinse delay of 3 seconds
when on.
• Delay Off/6 Sec.: Selects rinse delay of 6 seconds
when on.
POTENTIOMETER SETTINGS
• Rinse Control: Adjusts the rinse pump speed.
• Sani Control: Adjusts the sanitizer pump speed.
• Concentration or Recharge Pot: In “probe mode” sets
detergent concentration strength. In “probeless mode”
sets the pump time necessary to recharge the
detergent concentration.
• Alarm Delay or Initial Charge Pot: In “probe mode”
sets the time before the alarm sounds if the probe
senses low detergent concentration. In “probeless
mode” sets the pump time for detergent initial charge.
Knight’s unique probe life enhancement circuitry, first introduced in 1994, samples the washtank solution in short bursts of 1/100 th of a second
long. This rapid, short sampling greatly enhances probe life while holding the tightest concentration levels possible. The Dual Range Concentration
setting provides broad, linear adjustment ranges for easy setup in all types of water conditions. Knight’s PWM (Pulse Width Modulation) variable
speed circuitry ensures linear rinse motor speed adjustment and maximum brush life.
Adjustment Potentiometers