![](/html/a9/a9f9/a9f954099a5818a3f39f55f44ee066858d7617dbf857fb325d1da0d3b5834ed2/bg1.png)
PMP 800
PMP S
PMP S
YSTEM
YSTEM
A
PPLICATIONS
A
PPLICATIONS
PMP 900
The PMP Series peristaltic metering pump system is designed to
dispense a variety of cleaning and sanitizing chemicals.
Positive, accurate metering of liquids can be triggered manually
or by a process control signal. The PMP Series offer variable
speed output or fixed speed output with a choice of
programmable limit-timer or repeating cycle timer.
PMP is built with Knight’s field proven, long-life peristaltic
pumps. Moisture sensitive motor and controllers are enclosed in
a corrosion resistant, watertight, powder coated case that stands
up well for indoor and outdoor applications.
KEY FEATURES/BENEFITS:
Auto-Start or Optional Manual Button Activation NEW!
•
• Watertight, Secure Locking Enclosure NEW!
• Single or Multi-Product Remote Activator (Optional) NEW!
Long-Life Peristaltic Pumps
•
Water Resistant Case w/“D” Shaped Silicone Gasket NEW!
•
Long Lasting Squeeze Tube
•
Fixed or Variable Pump Speed
•
Wide Range of Flow Rates
•
Microprocessor, Push Button Programming Available NEW!
•
Pumps Up to 30 PSI
•
Self Priming, Easy to Service
•
Pump Lockout Option NEW!
•
FOOD & BEVERAGE
PROCESSING PLANTS
• CIP/COP
• Grease Traps
• Sewage Treatment
INDUSTRIAL
• General Cleaning
• Machinery Lubrication
• Cooling Towers
• Boilers
DAIRY
• Pipeline Cleaning/Sanitizing
• Teat Dip Chemical
• Wash Pen Chemical Injection
TRANSPORTATION
• Car Wash Stations
![](/html/a9/a9f9/a9f954099a5818a3f39f55f44ee066858d7617dbf857fb325d1da0d3b5834ed2/bg2.png)
PMP SPECIFICATIONS
Enclosure: Powder coated #304 stainless steel.
Pump Drive: Shaded pole AC or variable DC.
Squeeze Tube: Material available for most chemical applications.
Control: Limiting timer or repeating cycle timer.
Power Supply: 115VAC/60HZ, 230VAC/60HZ, 230VAC/50HZ
Dimensions: PMP-500: 9.3”H x 5.8”W x 5”D (23.6cm x 14.7cm x 12.7cm)
PMP-800: 9.3”H x 5.8”W x 5”D (23.6cm x 14.7cm x 12.7cm)
PMP-900: 13.6”H x 8”W x 7.5”D (34.5cm x 20.3cm x 19.1cm)
PMP AC FIXED SPEED
PMP AC FIXED SPEED
Snap-on Mounting Clips And
Plug-On Barrier Strips Provide
Quick And Easy Service of
Circuit Board
Secure Locking Enclosure
“D” Shaped Silicon
Gasket Provides Water
Resistant Seal
PMP 800
Electronic Control Options
KTM-600
lectronic variable limiting timer, standard on
E
time, 0-12 minutes. Pump activates by a
momentary switch or an electrical signal.
Pump lock-out feature prevents abuse and
over use of products. NEW!
Add -21 to Part # for 115/60 HZ
Add -22 to Part # for 230/60 HZ
Add -23 to Part # for 230/50 HZ
CT-200
Electronic Repeating Cycle Timer. Selectable off
period from 0-90 minutes. Pump on time
adjustable from 0-2 minutes.
Add -31 to Part # for 115/60 HZ
Add -32 to Part # for 230/60 HZ
Add -33 to Part # for 230/50 HZ
PMP w/o Control.
Add -01 to Part # for 115/60 HZ
Add -02 to Part # for 230/60 HZ
Add -03 to Part # for 230/50 HZ
PMP 500 SERIES (UP TO 4.4 GPH)
Model
PMP-530 8452134 T-50E 30 2.4 70 1.1
PMP-5100 8453142 T-50E 30 9.3 275 4.4
PMP 800 SERIES (UP TO 19 GPH)
Model
PMP-8120A 8457143 T-50E 30 23 670 11
PMP-8120B 8457830 T-66E 30 40 1180 19
PMP 900 SERIES (UP TO 105 GPH)
Model Part # Tube Max PSI Oz/Min mL/Min GPH
PMP-9130 8457760 T-86E 30 149 4400 70
MP-9270 8457765 T-86E 30 223 6600 105
Part # Tube Max PSI Oz/Min mL/Min GPH
Part # Tube Max PSI Oz/Min mL/Min GPH
PUMP ACTIVATOR OPTIONS
PUMP ACTIVATOR OPTIONS
rogrammable Pump
P
tart Buttons
S
Case Mounted Manual
Start Button
P/N 1900452
Pump On
Indicator LEDs
Multi-Product Remote Activator
P/N 7655140
PMP DC VARIABLE SPEED
PMP DC VARIABLE SPEED
Power Options
Add -01 to Part # for 115/60 HZ
Add -02 to Part # for 230/60 HZ
Add -03 to Part # for 230/50 HZ
PMP 500 SERIES (UP TO 5.3 GPH)
Model
PMP-515-3VS 8453405 T-53E 30 .88 26 .41
PMP-515VS 8453410 T-50E 30 1.45 43 .68
PMP-560VS 8453415 T-50E 30 5.10 152 2.65
PMP-5110VS 8453425 T-50E 30 11.2 332 5.3
PMP 800 SERIES (UP TO 16.8 GPH)
Model
PMP-8110VS 8453440 T-50E 30 21 614 9.7
PMP-8120B 8453445 T-66E 30 36 1081 16.8
PMP 900 SERIES (UP TO 63.4 GPH)
Model
PMP-9100VS 8450170 T-86E 30 135 4000 63.4
Part # Tube Max PSI Oz/Min mL/Min GPH
Part # Tube Max PSI Oz/Min mL/Min GPH
Part # Tube Max PSI Oz/Min mL/Min GPH
Single Product Remote Activator
P/N 7111460
KNIGHT LIMITED WARRANTY
KNIGHT LIMITED WARRANTY
Knightcontrolsand pump systems are warrantedagainstdefectsin material and workmanshipfor a periodof ONE YEAR. All ElectronicControlBoardshave a TWOYEAR warranty.
Warranty applies only to the replacement or repairof such parts when returned to thefactorywith a KRAnumber, freight prepaidand found to be defectiveupon factory inspection.
Rubberand syntheticrubberparts such as "O"rings, diaphragms, squeeze tubing and gaskets are consideredexpendable and arenot coveredunder warranty. Warrantydoes not
coverliabilityresulting from performanceof this equipmentnor the labor to replace this equipment.Productabuseor misuse voids warranty. Knight products are not foruse in
potentially explosiveenvironments. Any useof our equipmentin such anenvironment is atthe risk ofthe user. Knight does not accept any liability in such circumstances.
Knight Headquarters Knight Canada Knight Europe Knight Australia Knight N. Asia Knight S. Asia
Toll Free (800)854-3764 Tel (905)542-2333 Tel +44(1323)514.855 Tel +61(02)4223.7450 Tel +82(2)3481.6683 Tel +65.9170.0984
Tel (949) 595-4800 Fax (905)542-1536 Fax +44(1323)514.828 Fax +61(02)4271.8136 Fax +82(2)3482.5742 Fax +65.6489.6723
Fax (949)595-4801
www.knightequip.com
KNIGHT DISCLAIMER
The informationand specificationsincludedin this publication were in effect at the time of approval for printing. Knight,
LLC. reservesthe right, however,to discontinueor change
specificationsor design at anytime without notice and without
incurring any obligationwhatsoever.
ENBR_PMP_0909