KitchenAid KHMS175MBL, KHMS175MBT, KHMS175MSS, KHMS175MWH Dimension Guide

KitchenAid KHMS175MBL, KHMS175MBT, KHMS175MSS, KHMS175MWH Dimension Guide

® Microwave Hood Combination

PRODUCT MODEL NUMBERS

KHHS179L

KHMS175M

Electrical: A 120-volt, 60-Hz, AC-only, 15or 20amp. electrical supply located in the upper cabinet as close as possible to the microwave oven hood.

A time-delay fuse or circuit breaker and separate circuit is recommended.

OVERALL DIMENSIONS

17-1/4"

15-7/16" 29-7/8"

CABINET OPENING DIMENSIONS

12" to 14" recommended cabinet depth

30"min. cabinetopening width.

 

66" min.

 

 

 

 

30" min. to

NOTE: There must be

from floor to

 

 

cooking surface

top of wall

 

at least one wall stud

 

(or countertop)

mounting

 

within cabinet

 

below microwave

plate.

 

opening.

 

hood.

 

 

 

VENTING REQUIREMENTS

 

 

wall studs

 

 

 

 

 

 

 

 

 

Roof venting

 

roof cap

Wall venting

Recommended vent length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wall cap

Use 3-1/4" x 10" or 6" vent. The total length of the vent

 

 

 

 

 

system including straight vent, elbow, transitions, wall or

 

 

 

 

 

 

 

 

 

 

 

 

roof caps must not exceed the equivalent of 140 feet of

 

 

 

 

 

 

3-1/4" x 10" rectangular or 6" diameter round vent. For best

 

 

 

 

 

3-1/4" x 10"

performance, use no more than three 90° elbows. To

 

 

 

 

 

calculate the length of system you need, add the equivalent

 

 

 

 

 

through-the-wall

feet for each vent piece used in the system. See examples

 

3-1/4" x 10"

 

 

 

 

 

 

 

below.

 

 

 

 

through-the-roof

 

 

 

 

 

 

Recommended standard fittings

 

 

For wall or roof venting methods:

3-1/4" x 10" vent system

 

 

 

 

3-1/4" x 10"

 

 

 

 

 

 

 

 

If the wall exhaust method is chosen, be sure that

 

 

 

 

 

 

 

 

90° elbow

6 ft.

wall cap

 

 

 

 

 

there is proper clearance within the wall for the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exhaust vent.

 

 

 

 

 

 

 

 

 

Wall and roof caps must have back-draft damper.

 

 

 

 

 

 

 

 

 

We recommend:

2 ft.

1 - 3-1/4" x 10"

 

 

 

 

 

 

 

using rigid metal vent.

 

 

3-1/4" x 10"

3-1/4" x 10"

3-1/4" x 10"

 

90° elbow

= 25 ft.

that length of vent and number of elbows should

 

 

 

 

to 6" = 5 ft.

roof cap = 24 ft.

90° elbow = 25 ft.

 

1 - wall cap

= 40 ft.

 

 

 

 

 

be kept to a minimum to provide efficient

 

8 feet straight

=

8 ft.

 

 

 

 

 

performance.

 

Length of

 

 

 

 

 

 

 

that size of vent should be uniform.

 

3-1/4" x 10" system

= 73 ft.

 

 

 

 

 

using duct tape to seal all joints in the vent

 

 

 

 

 

 

6" vent system

 

 

 

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

 

 

 

90° elbow

3-1/4" x 10"

45° elbow

 

3-1/4" x 10"

using caulking compound to seal exterior wall or

90° elbows

6 ft.

 

 

= 10 ft.

wall cap =

= 5 ft.

 

flat elbow =

roof opening around cap.

 

 

 

 

 

 

 

 

40 ft.

 

 

10 ft.

two elbows should not be installed together.

 

 

 

 

 

 

 

 

 

 

 

 

 

If the existing vent is round, a rectangular- to-round adapter must be used and a rectangular 3" extension vent between the damper assembly and the adapter must be installed to prevent sticking of the exhaust damper.

We do NOT recommend:

 

 

 

1

- transition

=

5 ft.

 

 

 

2 ft.

flexible metal vent.

2

- 90° elbows

= 20 ft.

 

 

 

 

 

 

 

 

 

 

 

1

- wall cap

= 40 ft.

NOTE: If flexible metal vent must be used, calculate

 

 

 

 

 

 

8 feet straight

=

8 ft.

each foot of flexible metal vent as two feet of rigid

 

 

 

 

Length of 6" system = 73 ft.

metal vent. Flexible metal elbows count twice as

 

much as standard elbows.

 

 

transition

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8184059

Instructions packed with product. Specifications subject to change without notice.