KVS-2025 Automatic
Fire Sensing System
A UTC Fire & Security Company
Effective: February 2007
K-83-102
FEATURES
• Vehicle Fire System Control Panel |
• |
Alarm Silence Switch |
|
• |
Expandable, modular |
• LED annunciation of alarm, trouble, fire, operation |
|
• |
Programmable Time Delay |
• |
Low Maintenance |
• Multiple system discharge capability |
• 12V or 24V electrical systems |
||
• |
Battery Backup Module |
• FM approved, including heavy-duty off-road vehicle |
|
|
|
|
approvals |
DESCRIPTION
The Kidde® KVS detection system uses a fast response, infrared fire sensor, spot heat detection and/or Linear Heat Sensing Cable, all of which continually monitor the hazard area for a fire condition. Once a fire is detected, a signal is immediately sent to the control panel located in the operator’s area where a “FIRE” lamp is illuminated and an audible alarm is sounded. The control unit supplies engine shutdown and extinguisher discharge timing and activation. The dry chemical and/or foam system discharges suppressant routed through distribution hoses to nozzles located in the engine compartment, hydraulic network and other identified potential fire areas. The vehicle engine can be automatically shutdown to maximize effectiveness of the suppressant and to prevent reignition of the fire.
The Kidde KVS Automatic Fire Sensing and Suppression Systen is designed to detect and automatically suppress vehicle fires. The system responds to fires fueled by: diesel, gasoline, hydraulic fluid, and other fuels, including hydrogen.
Areas where fires can occur include:
•Engine Compartment:
–Fuel Tanks and Lines
–Hydraulic Reservoirs
–Lines and Accumulators
•Heaters
•Transmissions
•Battery Compartment
•Electrical Distribution and Raceways
TECHNICAL DATA
•Power Requirement: 12 Vdc or 24 Vdc (9 to 32 Vdc)
•Quiescent (Fire Only): 2.4 W
•Extinguisher Valve Drive Requires 15 A for 30 ms
•Temperature Rating: -40ºF (-40ºC) to 158ºF (70ºC)
•Automatic Interface
•Normally-Open 3 Amp Contact Shorts to Ground when in Alarm
•Engine Shutdown
•Fuel Pump and/or Fuel Valve Shutdown
•Fan Shutdown
•Delay System/Engine-Shutdown Button (15 sec. delay per activation)
•Alarm Silence, Reset, Indicator Test Button
•Manual Discharge Input