Kenwood DPX-301, DPXMP-2090, DPXMP-2090-S Service manual

CD RECEIVER
DPX301 DPX-MP2090/MP2090S
© 2005-12 PRINTED IN JAPAN
DPX301
(K type)
EXTERNAL MEDIA CONTROL
B53-0370-00 (N) 724
SCRL
FM
DPX-MP2090 DPX-MP2090S
(M type)
DPX-MP2090/MP2090S
Remote controller assy (A70-2069-15)
SIZE AA BATTERY (Not supplied)
AUTO
VOL
AUD SET UP
ATT
s
AUTO
VOL
AUD SET UP
ATT
MENUAME
EXTERNAL MEDIA CONTROL
MENUAME
REPRDMSCAN
REPRDMSCAN
F.SEL
F.S EL
OFF
M.RDM
OFF
M.RDM
DC cord DPX-MP2090/MP2090S: (E30-6408-05)
System
SW
AM
C.S.
EX
SCRL
FM
SW
AM
Panel assy (A64-3785-12)
Panel assy (A64-3811-12) : DPX-MP2090 (A64-3812-12) : DPX-MP2090S
Escutcheon assy (B07-3046-04)
DPX301: (E30-6428-05)
Screw set (N99-1779-05)
DPX301
RC-517
Escutcheon (B07-3172-12)
Escutcheon (B07-3165-02)
Mounting hardware assy (J22-0429-03)
Lever (D10-4589-04) x2
Adhesive double­coated tape (H30-0595-04)
This product uses Lead Free solder.
DPX301 DPX-MP2090/MP2090S
ELECTRIC UNIT (X34- )

BLOCK DIAGRAM

BU5V
OPEL DISP MARINE DISP
ONLY CN
A1
FRONT-END
TUN8V
SW5
AM+B
LX-BUS
3
713
IC1
IC7
RESET
BU5
CN
SW5
ROTAR Y ENCODER
SW5
Q6,7
RESET
IC1
REMOTE SW5V
A8V
PRE+B
PREF
BU
SYSTEM u-COM
2
PAN5
IC2
MUTE DC-DET
Q13
PAN5V
BU5
SERVO+B
E-VOL
MUTE
38
5
A8V
1
ILLUMI+B
D5V
CD
2
1
10
FL+B D5V
ED1
KEY ILLUMI
SWITCH UNIT (X16- )
COLOR SELECT
BU5
1 1
2
9
FL DRIVER & KEY MATRIX
BU
IC4
POWER SP-OUT
3
IC
1
Q400-403
MUTE
IC6
MUTE LOGIC
BU5
DC-CN etc
PHONE DIMMER / ACC DET BU DET / ANT CON P CON / PON PON CD / PON ILLUMI EX AMP
KEY MATRIX
BU DET
RST
SERVO+B
ILLUMI+B
FRONT L/R REAR L/R NF L/R
PRE-OUT
FRONT/REAR
SW5
P.ON
BU5
D5
A8V
AM+B
AM+B
TUN8V
SW5
PON ILL
Q3
Q300
Q302
Q305
ACC DET
ANT CON
SW5V
AM+B
TUNER 8V
SW ILL+B
PHONE
DIMMER
BU DET
EX AMP
P CON
PHONE
Q108
DIMMER
Q112
ACC-DET
Q109
SURGE­DET
Q111
BU-DET
Q107
EXT­AMP-CON
Q101
ANT-CON
Q103
PCON-SW
Q1
BU5V
IC12
CD5V
IC3,Q5
A8V
Q7
CD SERVO
Q4 SW14V
IC5
ILLUMI +B
BU5
BU5
BU5
PON CD
P ON
P ON
P ON
DC-CN
PHONE ILLUMI ACC B.U. EXT-CONT
P-ANT P-CON
DPU1
ACB
EF
FO COIL TR COIL
DM1
SPINDLE MOTOR
DM2
LOADING & SLED MOTOR
CD PLAYER UNIT (X32-586x-xx)
IC7
1.6V REG
RF AMP
+
SERVO
Q4
APC
IC3
MOTOR DRIVER
S.GND
PROCESSOR
+
MP3 DECODER
+
WMA DECODER
+
AAC DECODER
+
1Mbit SRAM
VREF
X2
CLOCK
16.934MHz
IC10
DRAM
4Mbit
D.GND
D.GND
DMUTE
IC4
MECHA u-COM
X1
CLOCK
16.00MHz
IC1
A3.3V REG
P-ON2 P-ON1
D.GND
IC2
IC6
D3.3V REG
LPF
IC5
BU3.3V REG
D.GND
D.GND
D.GND
Q7,8
SW
D.GND
0-01 ONLY
S.GND
MOTHER BOARD (X34- )
A8V
L-ch R-ch
A.GND D.OUT
MRST MSTOP CLK DAT A MUTE L MUTE R
BU5V D.GND
D5.0V
S3
LOE/LIM-SW
S4
8EJE-SW
S2
12EJE-SW
S1
LOS-SW S.GND
S7.5V LO/EJ MOTOR
2
DPX-MP2090/MP2090S

COMPONENTS DESCRIPTION

SWITCH UNIT (X16-3530-xx)

Ref. No. Application / Function Operation / Condition / Compatibility
IC1 Remote Control IC Q1~3 GRID_DRIVER Each Transister’s base is “L” then GRID is On Q6,7 SW5V The power supply of IC1 is turned on when Q6’s base level goes “L” Q9 RED SW RED LED is turned on when Q9’s base level goes “H” Q12 VFD RESTART Key scan start at Q12’s Base goes “H” when the SET’s Power is On

ELECTRIC UNIT (X34-4140-xx)

Ref. No. Application / Function Operation / Condition / Compatibility
IC1 System µ-COM Controls FM/AM tuner, the changer, CD mechanism, Panel, volume and tone IC2 E. Vol Controls the source, volume, tone IC3 A8V Ref Power Supply Output 1.27V IC4 Power IC Amplifies the front L/R and the rear L/R to 50W maximum. IC5 ILL+B Power Supply Output 1.225V IC6 Muting logic IC Controls logic for muting IC7 Reset IC “L” when detection voltage goes below 3.6V or less IC12 SW Regulator Power Supply for mp3 and VFD Q1,2 B.U.5V AVR While BU is applied, BU5V AVR outputs +5V Q3,11 SW5V When Q11’base goes Hi, SW5V outputs +5V Q4,9 SW14V When Q9’base goes Hi, SW14V outputs 14V Q5,6,10 AUDIO8V AVR When Q10’base goes Hi, A8V AVR outputs 8.0V Q7,8 SERVO+B AVR When Q8’base goes Hi, S+B AVR outputs 7.5V Q12 SW for IC12 When Q12’base gose Lo, IC7 is turned on Q13 PANEL 5V When Q13’base gose Lo, PANEL5V outputs 5V Q101,102 P-ANT SW When Q102’base goes Hi, P-ANT SW outputs 14V Q103,106 P-CON SW When Q106’base goes Hi, AVR outputs 14V Q104,105 P-CON Protection Protect Q103 by turning on when P-CON output is grounded Q107 EXT-AMP-CON When Q107’base goes Lo, Q107 is turned on Q108 Small lamp det SW When Q108’base goes Hi, Q108 is turned on Q109 SERGE Det. When Q109’base goes Hi, IC4 is changed into a standby state Q111 BU det When Q111’base gose Hi, Q111 is turned on Q112 ACC det When Q112’base gose Hi, Q112 is turned on Q113 Mute-Driver When a base gose Hi, Pre-out mute driver is turned on Q114 Mute-Driver Q114 turned on by RST Q115,116 Pre-out mute driver When a base gose Lo, mute driver is turned on Q298,299 Tuner8V SW When Q299’base goes Hi, Tuner8V output 8V Q300,301 AM+B When Q301’base goes Hi, AM+B is out Q302,303 Tuner8V When Q303’base goes Hi, Tuner8V outputs 8V Q305,306 SW ILL+B When Q306’base goes Hi, SW ILL+B outputs 11V Q400~403
Pre-out mute SW When a base goes Hi, Pre-out is muted
DPX301
3
DPX301 DPX-MP2090/MP2090S
COMPONENTS DESCRIPTION

CD PLAYER UNIT (X32-5860-00)

Ref. No. Application / Function Operation / Condition / Compatibility
IC1 A3.3V regulator Power supply for audio 3.3V IC2 Ope amp for low-pass filter IC3 4ch BTL driver Driving spindle motor and loading/ejection operation IC4 Mechanism µ-com IC5 BU 3.3V regulator Power supply for backup 3.3V IC6 D3.3V regulator Digital 3.3V power supply IC7 Audio DAC built-in servo DSP MP3, WMA, and AAC compatible IC11 Buffer IC Level shift Q1 A3.3V discharge circuit Q4 Current amp Adjusts current to be sent to laser Q5,6 SW 5V Q7,8 SW 8V D1 For current amp
4
DPX-MP2090/MP2090S

MICROCOMPUTER’S TERMINAL DESCRIPTION

SYSTEM MICROCOMPUTER: 30624MGPA76GP (X34: IC1)

Pin No. Pin Name Module I/O Application
1 REMO EXTRA I Remote control signal input Detect pulse width 2 LX_MUTE LX_M I MUTE request from slave unit H: Mute ON, L: Mute OFF 3AUD_SDA AUDIO O E-VOL data output terminal 4AUD_SEL AUDIO O E-VOL control terminal 5AUD_SCL AUDIO O E-VOL clock output terminal 6 BYTE µCOM ­7 CNVSS µCOM ­8 XCIN µCOM I 9 XCOUT µCOM I 10 RESET µCOM ­11 XOUT µCOM ­12 VSS µCOM ­13 XIN µCOM - 12.0MHz 14 VCC1 µCOM ­15 NMI µCOM I Not used 16 CN_DET EXTRA I Panel communication detection (FLIP) H: PANEL detached, L: PANEL attached 16 NC O Not used (2DIN) Fixed to L
17 RDS_CLK TUNER I
17 NC O Not used (except RDS model) Output L fixed 18 LX_REQ_S LX_M I Communication request from slave unit 19 PON_AM 20 LX_REQ_M LX_M O Communication request to the slave unit 21 TUN_IFC_OUT TUNER I F/E IFC OUT input terminal H: Station found, L: Station not found 22 NC O Not used Output L fixed
23 RDS_AFS_M TUNER I/O
23 NC O
24 RDS_QUAL TUNER I
24 NC O Not used (except RDS model) Output L fixed
25 RDS_DATA TUNER I
25 NC O Not used (except RDS model) Output L fixed 26 PWIC_BEEP PWIC O Beep output 27 TUN_SCL TUNER I/O F/E I2C clock input/output terminal 28 TUN_SDA TUNER I/O F/E I2C data input/output terminal
Power supply
RDS decoder CLK input terminal (RDS model only)
I/O AM power supply control H: When AM, Hi-z: When not AM
Constant number switching when noise detected (in RDS and RBDS models) Not used (except RDS and RBDS models) RDS decoder QUAL input terminal (RDS model only)
RDS decoder DATA input terminal (RDS model only)
Truth
value table
w Refer to the truth value table
Processing Operation Description
Output L fixed
DPX301
5
DPX301 DPX-MP2090/MP2090S
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No. Pin Name Module I/O Application
29 VFD_DATA to PANEL I/O VFD data input/output terminal Data input/output 30 VFD_INT to PANEL I VFDINT input terminal INT input terminal
31 VFD_CLK to PANEL O VFD clock output terminal
32 VFD_RST to PANEL O VFD driver reset terminal L: Momentary power down, when panel
33 SDA/CD_SDA CD I/O
33
34 SCL/CD_SCL CD I/O
34
35 PON_PANEL
36 DSI EXTRA I/O
36 NC O Not used (2DIN) Output L fixed 37,38 NC O Not used Output L fixed 39 EPM µCOM I FLASH EPM input terminal 40 PANEL_DET EXTRA I Panel detection (FLIP only) L: PANEL detached, H: PANEL attached 40 NC O Not used (2DIN) Output L fixed 41 NC O Not used Output L fixed 42 ROMCOR_DET EXTRA I E2PROM writing-in request H: Writing-in 43 NC O Not used (no USB model) Output L fixed 43 PON_FL 44 VFD_CS to PANEL O VFD chip select control terminal 45 ROTARY_CW to PANEL I VOL key input Detect pulse width 46 ROTARY_CCW to PANEL I VOL key input Detect pulse width 47 CD_DISC12_SW CD I CD disc detection terminal (12cm) 48 CD_LOS_SW CD I CD loading detection terminal
49 CD_MUTE_R CD I CD MUTE (Rch) request terminal
50 CD_MUTE_L CD I CD MUTE (Lch) request terminal
51 CD_MRST CD O CD mechanism µ-com RST terminal H: Normal, L: RESET
52 CD_MSTOP CD O CD mechanism µ-com stop terminal
SDA/ROMCOR_SDA
SCL/ROMCOR_SCL
EXTRA I/O
EXTRA I/O
Power supply
Power supply
CD mechanism I2C data input/output terminal E2PROM I2C data input/output terminal for ROM correction CD mechanism I2C clock output terminal E2PROM I2C clock output terminal for ROM correction
I/O Panel 5V control terminal (FLIP model)
DSI/EJECT_LED (FLIP only) control terminal H: ILL_ON and OPEN (when Power_ON)
O FL+B control (USB model) H: FL+B ON, L: FL+B OFF
Truth
value table
Processing Operation Description
Normal: 125kHz Low consumption mode: 62.5kHz H: Clear RESET, L: RESET
detached and 11 minutes after ACC_OFF
L: ON, Hi-Z: Momentary power down, when panel detached and 11 minutes after ACC_OFF Hi-z: OFF, Pulse drive: When PANEL detached
H: Normal, L: Rch mute request (valid only when in CD mode) H: Normal, L: Lch mute request (valid only when in CD mode)
H: Mechanism µ-com in operation L: Mechanism µ-com stop
6
DPX-MP2090/MP2090S
MICROCOMPUTER’S TERMINAL DESCRIPTION
DPX301
Pin No. Pin Name Module I/O Application
53 CD_DISC8_SW CD I 53 NC CD O Not used (except J) Output L fixed 54 55 CD_LOEJ CD I/O CD motor control terminal q Refer to the truth value table 56 CD_MOTOR CD O CD motor control terminal q Refer to the truth value table 57 PON_ILLUMI
58
58 PON_CD
59 PON 60 VCC2 µCOM ­61 EXT_AMP_CON EXTRA I/O EXTERNAL AMP control
61 NC O
62 VSS µCOM - 63 TYPE_1 TYPE I Destination switching r Refer to the truth value table 64 TYPE_2 TYPE I Destination switching r Refer to the truth value table 65 TYPE_3 TYPE I Destination switching r Refer to the truth value table 66 TUN_TYPE1 TYPE I Destination setting 1 e Refer to the truth value table 67 TUN_TYPE2 TYPE I Destination setting 2 e Refer to the truth value table 68 68 NC O Not used (M, J destinations only) Output L fixed 69 OEM_DISP_CLK EXTRA I/O External display CLK External display 69 NC O Not used (M, J destinations only) Output L fixed 70 OEM_DISP_CE EXTRA I/O External display control request External display 70 NC O Not used (M, J destinations only) Output L fixed 71 EJECT to PANEL I Eject key input (FLIP model only) L: EJECT 71 NC O Not used (2DIN) Output L fixed
72 P_CON
73 VFD_KEY_REQ toPANEL I Communication request from VFD driver Connect to INT 74 ANT_CON EXTRA O Power antenna control TUNER ON: H 75 ILLUMI_DET EXTRA I Dimmer illumi detection L: ON, H: OFF
76 BU_DET EXTRA I Momentary power down detection
77 ACC_DET EXTRA I ACC power supply detection L: ACC ON, H: ACC OFF
78 (PWIC_SVR) PWIC O SVR discharging circuit
CD_LOE_LIM_SW
PON_PANEL_CD
OEM_DISP_DATA
CD I CD detection terminal (chucking SW) H: Loading completed, L: No disc
Power supply
Power supply
Power supply
Power supply
EXTRA I/O External display DATA External display
Power supply
CD disc detection terminal (8cm) (J only)
I/O Key illumi power supply control ON: H, OFF: Hi-Z
Power supply control terminal for L: POWER ON, H: POWER OFF
O
panel 5V/CD WMA (no USB model) L: When resetting before M-STOP Power supply control terminal for L: POWER ON, H: POWER OFF
O
CD WMA (USB model) H: When resetting before M-STOP
OPower supply control POWER ON: H, POWER OFF: L
Not used (for destination without EXTERNAL AMP CON)
O External amplifier control terminal
Truth
value table
Processing Operation Description
Output L fixed
H: POWER ON, L: POWER OFF L: STANDBY source
L: BU found H: BU not found, momentary power down
H: For 5 seconds after POWER OFF momentary power down, L: Thereafter
7
DPX301 DPX-MP2090/MP2090S
MICROCOMPUTER’S TERMINAL DESCRIPTION
Pin No. Pin Name Module I/O Application
79 PWIC_MUTE PWIC O Power IC MUTE terminal
80 PWIC_STBY PWIC O Power IC standby control POWER ON: H, POWER OFF: L 81 LX_CON LX_M O Start-up request to slave unit H: Slave unit ON, L: Slave unit OFF
82 MUTE_PRE_R AUDIO O PRE_OUT MUTE Rch H: When momentary power down
83 MUTE_PRE_L AUDIO O PRE_OUT MUTE Lch H: When momentary power down
84 MUTE_0 AUDIO I/O E-VOL FRONT MUTE terminal L: MUTE ON, Hi-Z: MUTE OFF 85 MUTE_1 AUDIO I/O E-VOL REAR MUTE terminal L: MUTE ON, Hi-Z: MUTE OFF 86 MUTE_2 AUDIO I/O E-VOL OTHER MUTE terminal L: MUTE ON, Hi-Z: MUTE OFF
87 LINE_MUTE EXTRA I Line mute detection
PRE_OUT MUTE NF
88 MUTE_PRE_SW AUDIO I/O When REAR is selected for REAR/SUB L: MUTE ON, Hi-Z: MUTE OFF
switching, do not port-process (FMC) 88 NC O Not used (MMC) Output L fixed 89 PWIC_DC_DET PWIC I DC offset detection terminal 90 LX_RST LX_M O Hardware-reset to slave unit H: Reset, L: Normal
91 MUTE_AFS AUDIO I/O
91 MUTE_C AUDIO I/O
91 NC O
92 NC O Not used Output L fixed 93 RDS_NOISE TUNER I FM noise detection terminal 94 AVSS µCOM ­95 TUN_SMETER TUNER I S meter input 96 VREF µCOM - Connect to P_ON 97 AVCC µCOM - Connect to VCC 98 LX_DATA_S LX_M I Data from slave unit 99 LX_DATA_M LX_M I/O Data to slave unit 100 LX_CLK LX_M I/O LX-BUS clock
TUNER output MUTE terminal (for AFS)
(models with USB and RDS)
E-VOL MUTE terminal (for AFS)
(models without USB, with RDS)
Not used (no RDS model,
including no RBDS model)
Truth
value table
Processing Operation Description
L: When in STANDBY source, at momentary power down, L: While TEL MUTE
H: When CD MUTE R is L (while playing CD)
Fixed to L: Only when 2 zone or NAVI interruption H: When CD MUTE L is L (while playing CD)
Fixed to L: Only when 2 zone or NAVI interruption
TEL MUTE: 1V or lower NAVI MUTE: 2.5V or higher In J-TYPE, NAVI MUTE: 1V or less, or 2.5V or higher
L: MUTE ON, Hi-Z: MUTE OFF
L: MUTE ON, Hi-Z: MUTE OFF
Output L fixed
8
MICROCOMPUTER’S TERMINAL DESCRIPTION
Truth value table
q CD_MOTOR, CD_LOEJ
CD_MOTOR CD_LOEJ
Stop L L Load H L Eject H H
Brake H Hi-z
e TUNER TYPE
TUN_TYPE1 (66PIN) TUN_TYPE2 (67PIN)
Kenwood brand model L L
OEM model 1 L H OEM model 2 H L OEM model 3 H H
DPX301
DPX-MP2090/MP2090S
w AFS control
RDS_AFS_M RDS_AFS_L Status
AFS LOW L Not used No sound output in AF search
AFS MID L Not used Sound output in AF search
AFS HIGH Hi-Z Not used Normal reception
r 06 FLIP/2DIN, no USB model (MID)
TYPE3 TYPE2 TYPE1 Destination X34-414 (2DIN)
110DPX301 0-10 111DPX-MP2090/S 0-21
9
DPX301 DPX-MP2090/MP2090S
MICROCOMPUTER’S TERMINAL DESCRIPTION

CD MECHANISM MICROCOMPUTER: 703030BYGCJ21A (X32: IC4)

Pin No. Pin Name I/O Application
1NC-Not used Low-fixed 2 E2P SCL I/O Rom correction E2P I2C clock 3~5 NC - Not used Low-fixed 6 VDD - 5V electric potential 7 GND - GND electric potential 8,9 NC - Not used Low-fixed 10,11 PON1,PON2 O Po wer ON/OFF control H : ON, L : OFF 12 LOE/LIM SW I Down-limit SW detection L : Lim detection
13 DAC MUTE O DAC MUTE control H : MUTE ON, L : MUTE OFF With DXM-6580W (X32-574), open
14 DAC RST O DAC RESET H : NORMAL, L : RESET With DXM-6580W (X32-574), open
15 EMPH O External DAC Emphasis control
16,17 NC - Not used Low-fixed
18 IC/Vpp - Write voltage (FLASH)
19 MUTE L O Lch audio MUTE control L : MUTE ON, H : MUTE OFF 20 MUTE R O Rch audio MUTE control L : MUTE ON, H : MUTE OFF
21 TYPE I DAC switching
22 TEST O 1 O TEST MODE O 1 (Not used) 23 TEST O 2 O TEST MODE O 2 (Not used) 24 TEST O 3 O TEST MODE O 3 (Not used) 25 TEST O 4 O TEST MODE O 4 (Not used) 26 NC - Not used Low-fixed 27 WAIT I Wait control signal detection 28~30 NC - Not used Low-fixed 31 RESET I Reset detection H : NORMAL, L : RESET 32 XT1 I Not used 33 XT2 - Not used 34 REGC ­35 X2 ­36 X1 I 37 Vss - GND electric potential 38 VDD - 5V electric potential 39 NC - NC Output stopped in standby 3.3V driven 40 WRL I Multiplex WRITE signal 3.3V driven
Processing Operation
Description
H : Emphasis ON L : Emphasis OFF
L : Normal operation H : In writing
H : DSP built-in DAC used L : DSP built-in DAC Not used
Remarks
Used with DXM-6680W (X32-586).
and L-fixed. Used with DXM-6680W (X32-586).
and L-fixed. Used with DXM-6680W (X32-586). With DXM-6580W (X32-574), open and L-fixed.
H : DXM-6580W (X32-574) L : DXM-6680W (X32-586)
10
DPX-MP2090/MP2090S
MICROCOMPUTER’S TERMINAL DESCRIPTION
DPX301
Pin No. Pin Name I/O Application
41,42 NC - Not used Low-fixed 3.3V driven 43 RD O Multiplex RD signal 3.3V driven 44 ASTB O Multiplex ASTB signal 3.3V driven 45 NC - Not used Low-fixed 3.3V driven 46 NC - Not used Low-fixed 3.3V driven 47~54 AD0~AD7 I/O Multiplex address/data 3.3V driven 55 BVdd - BUS interface power supply 56 BVss - BUS interface GND 57~61 AB8~AB12 I/O Multiplex data/address 3.3V driven 62~65 NC - Not used Low-fixed 3.3V driven 66 CS O Chip select control H : OFF, L : ON 3.3V driven 67 DSP RESET O DSP reset control H : NORMAL, L : RESET 3.3V driven 68~70 NC - Not used Low-fixed 3.3V driven 71 Avdd ­72 Avss ­73 Avref I A/D port reference voltage input 74 NC - Not used Low-fixed
75 RAMSEL I
76 RZM I 0bit MUTE detection H : 1.7V, L : <1.7V 77 LZM I 0bit MUTE detection H : 1.7V, L : <1.7V
78 AAC I AAC compatibility switching
79 ASEL I Audio output polarity switching
80 E2P WR I E2PROM write switching
81 TEST I 0 I TEST MODE I 0 (Not used) 82 TEST I 1 I TEST MODE I 1 (Not used) 83 TEST I 2 I TEST MODE I 2 (Not used) 84 TEST I 3 I TEST MODE I 3 (Not used) 85,86 NC - Not used Low-fixed 87 MSTOP I Standby restart interruption H : STOP release, L : STOP 88 INTSV I Interruption from servo IC H : Interruption 89~92 NC - Not used Low-fixed 93 D-MUTE O Driver MUTE H : OFF, L : ON 94 SYS SDA I/O System µ-com I2C data Flash write port (SI0) 95 NC - Not used Low-fixed Flash write port (SO0) 96 SYS SCL I/O System µ-com I2C clock Flash write port (SCK0) 97~99 NC - Not used Low-fixed 100 E2P SDA I/O ROM correction E2P I2C data
With DRAM/No DRAM switching for different models
Processing Operation
Description
H : With DRAM, L : No DRAM
H : AAC non-compatible AAC non-compatible mode has priority L : AAC compatible for both hardware and software. H : Reverse output L : Non-reverse output H : E2PROM WRITE L : NORMAL
Remarks
11
DPX301 DPX-MP2090/MP2090S

TEST MODE

How to enter the test mode
Press and hold the [1] and [3] keys and reset. (While ”– – – –“ is being displayed, power can be ON for 30 minutes.)
How to clear the test mode
Reset, momentary power down, Acc OFF, Power OFF.
Test mode default condition
• Source is STANDBY.
• Display lights are all turned on.
• The volume is at -10dB (The display is 30).
• LOUD is OFF.
• CRSC is off regardless of the av ailability of switching func­tion.
• SYSTEM Q is NATURAL (=FLAT).
• BEEP is always activated by briefly pressing a button.
• AUX is ON.
• SWPRE is SUB WOOFER (2PREOUT model).
Special display in tuner mode
Error is found in front-end, etc. if indications below are dis­played while in tuner mode. “TNE2P_NG”: Front-end E2PROM values are still default (not determined). “TNCON_NG”: Cannot communicate with the front-end.
K3I forced switching
Every time when [6] key is pressed in tuner FM mode, switched in the following order: AUTO → Forced WIDE Forced MIDDLE Forced NARROW AUTO. Default status is AUTO, and displayed as shown below. AUTO: FM1_98.1A Forced WIDE: FM1_98.1W Forced MIDDLE: FM1_98.1M Forced NARROW: FM1_98.1N
CD receiver test mode specification
• Display mode default setting shall be P-TIME.
• Jumps to the following tracks by pressing the [ No. 9 No. 15 No. 10 No. 11 No. 12 No. 13 No. 22 No. 14 No. 9 (recursive) Note that when playing an MP3/WMA/AAC disc with 8 files or less, the disc is played from the 1st track in the normal order.
] key.
• Pressing the [ being played.
• When playing an MP3/WMA/AAC disc, display the file for­mat before starting to play each file. (“MP3”, “WMA”, “AA C”)
• When CD is the source, press the [1] k ey briefly to jump to No. 28.
• When CD is the source, press the [2] k ey briefly to jump to No. 14.
• When CD is the source, press the [3] key briefly to display CD mechanism model name and the version. Press the [3] key briefly again to go back to the normal screen. (time code display)
] key goes back by 1 track from the track
6680:0123
Model name Version
• When CD is the source, press the [6] k e y to jump to No . 15. At this time, the volume value is set to 25 (2V PRE).
AUDIO adjust mode
• Press [A UD] k ey briefly to enter the audio adjustment mode.
• Press the remote control [] key and [AUD] key to go into the audio adjustment mode.
• Both AUDIO FUNCTION MODE and SETUP MODE ad­justment items are included.
• By pressing [AUD] or [FM] key briefly , switch the item to be adjusted in the following order. (only in forward rotation) The default item shall be Fader, and then the item is for­warded in the following order: Balance Bass Level Middle Level → T reble Level HPF Front HPF Rear LPF Sub Woofer (thereafter arbitrary).
• Continuous forwarding by remote control is prohibited.
• Fader is adjusted by the VOL knob and [ ] / [ ] keys in 3 steps: R15 0 F15. (Default value: 0)
• Balance is adjusted by the VOL knob and [ ] / [ ] keys in 3 steps: L15 0 R15. (Default value: 0)
• Bass/Middle/Treble Le vel are adjusted b y the V OL knob and [
] / [ ] keys in 3 steps: -8 ↔ 0 +8. (Def ault value: 0)
• HPF Front / Rear is adjusted by the VOL knob and [ [
] keys in 2 steps: Through 180Hz (or 220Hz). (De-
fault value: Through)
• LPF Sub Woofer is adjusted by the VOL knob and [ ] /
] keys in 2 steps: 60Hz (or 50Hz) ↔ Through. (Default
[ value: Through)
] /
12
TEST MODE
DPX301
DPX-MP2090/MP2090S
• Sub Woofer Phase is adjusted by the VOL knob and [ ] / [
] keys in 2 steps: Reverse Normal.(Default value:
Normal)
•Volume Offset is adjusted by the VOL knob and [ ] / [ ] keys in 2 steps: -8 0. (Default value: 0)
• Loudness ON/OFF is adjusted by the VOL knob and [ ] /
] keys in 2 steps: OFF ON. (Default value: OFF)
[
• Bass f / Bass Q / Bass EXT / Middle f / Middle Q / Treble f are not displayed on the audio adjustment mode.
MENU
• Press the [Q] key to enter the MENU.
• Press the remote control [DNPP/SBF] ke y or the [DIRECT] key to enter the MENU.
• Continuous forwarding by remote control is prohibited.
Backup current measurement
If reset while in Acc OFF (Back Up ON) condition, MUTE terminal goes off 2 seconds later, rather than 15 seconds. (During this time, the CD mechanism does not function.)
Special displays while all lights are on
When all lights are on with STANDBY source, if the follow­ing keys are pressed, the f ollowing messages are display ed.
[1] Version is displayed (forwarding).
key (Display) TYPE : x_ _ _
530K–1.02 → (“development ID” – “version”)
all lights on TYPE indicates µ-com destination, and shows real-time condition of the destination terminal.
[2] Serial No. is displayed (8 digits).
key (Display) xxxxxxxx
[3] Key pressed briefly: Power ON time is displayed.
key While Power ON time is displayed, press and hold for 2
seconds to clear the Power ON time. (Display) PON_0Hxx (00~50 is displayed for “xx”.
xxxxx
(“x" is displayed in hexadecimals)
When less than 1 hour, display by increment of 10 minutes)
(00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[4] Key pressed briefly: CD operation time is displayed.
key While CD operation time is displayed, press and hold for
2 seconds to clear the CD operation time. (Display) CDT_0Hxx (00~50 is displayed for “xx”.
When less than 1 hour, display by increment of 10 minutes)
xxxxx
Key pressed briefly: Number of CD EJECT time is displayed.
[5]
key While the CD EJECT times is displayed, press and hold
for 2 seconds to clear the CD EJECT time. (Display) EJCxxxxx MAX 65535 (times)
[6] Not used.
key
[FM] ROM correction version is displayed.
key (Display) ROM_R123
When E2PROM is not installed: ROM_ERR_
When not written in: ROM_R– – –
When data not matching: ROM_R∗∗∗
[ ]AUDIO data initialization
key (Display) AUD_INIT
[ ]Key pressed briefly: Forced Power OFF data displayed.
key While the forced power OFF data is displayed, press and
hold for 2 seconds to clear the data. (Display) POFF_ – – –
[ ]
Key pressed briefly: CD information display mode ON/OFF.
key While in CD information display mode, press and hold for
2 seconds to clear all CD information. Please refer to the next table.
CD information display mode
I2C communication condition display (Display) I2C_OK_ _
NG
[AM] CD mechanism error log display
key(switched by [ ] / [ ] keys)
(Display) MCERR1: xx MCERR2: xx MCERR3: xx
MCERR1: xx
(“– –” or the error code is displayed for “xx”)
(00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
(No Forced Power OFF) Fixed display
13
Loading...