Kenmore 153.330280, 153.330290 User Manual

0 (0)

Use & Care Guide

Model No.

153.330280 40 Gallon Tall

153.330290 50 Gallon Tall

Kenmore®

Gas Water Heater

LOW LEAD COMPLIANT

For potable water heating only.

Not suitable for space heating.

Not for use in mobile homes.

INSTALLER: A x these instructions to or near the water heater.

OWNER: Retain these instructions for future reference.

FOR YOUR SAFETY: An odorant is added to the gas used by this water heater.

ADVERTENCIA

Si no puede leer o entender el inglés y necesita el manual de instrucciones en español, puede solicitarlo al 1-800-821-2017. NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES. No hacer caso de esta advertencia podría originar lesiones graves o mortales.

P/N 319590-002 (1010)

Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A.

www.kenmore.com

www.sears.com

1

SAFE INSTALLATION, USE AND SERVICE

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards.

Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low-level exposure to some of the substances included in the act.

IMPORTANT DEFINITIONS

Qualified Technician: A qualified technician must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be familiar with the design features and use of flammable vapor ignition resistant water heaters, and have a thorough understanding of this instruction manual.

Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The service agency must also have a thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.

Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.

 

SAFETY PRECAUTIONS

 

 

WARNING

 

 

FIRE AND EXPLOSION HAZARD

 

 

Can result in serious injury or death

 

 

Do not store or use gasoline or other

 

 

flammable vapors and liquids in the vicinity of this

 

 

or any other appliance. Storage of or use of

FLAMMABLES

Flammable Vapors

gasoline or other flammable vapors or liquids in the

vicinity of this or any other appliance can result in

 

 

serious injury or death.

Read and follow water heater warnings and instructions.

© Sears Brands Management Corporation

2

3

TABLE OF CONTENTS

SAFE INSTALLATION, USE AND SERVICE......................................................................................................................

2

SAFETY PRECAUTIONS...........................................................................................................................

2-3

TABLE OF CONTENTS.................................................................................................................................

4

WARRANTY...................................................................................................................................................................................

5

CUSTOMER RESPONSIBILITIES.........................................................................................................................................

6

PRODUCT SPECIFICATIONS ................................................................................................................................................

6

MATERIALS AND BASIC TOOLS NEEDED.......................................................................................................................

7

Materials Needed .....................................................................................................................................................

7

Basic Tools................................................................................................................................................................

7

TYPICAL INSTALLATION..........................................................................................................................................................

8

INSTALLATION INSTRUCTIONS.....................................................................................................................................

9-18

Removing the Old Water Heater...............................................................................................................................

9

Facts to Consider About the Location................................................................................................................

10-11

Insulation Blankets ............................................................................................................................................

11-12

Combustion Air and Ventilation Appliances in Unconfined Spaces ........................................................................

12

Combustion Air and Ventilation Appliances in Confined Spaces .......................................................................

12-13

Water Piping ......................................................................................................................................................

13-14

T & P Valve and Pipe Insulation .............................................................................................................................

14

Temperature Pressure Relief Valve ...................................................................................................................

15,16

Filling the Water Heater ..........................................................................................................................................

16

Venting...............................................................................................................................................................

16-17

Gas Piping .........................................................................................................................................................

17,18

Sediment Trap ........................................................................................................................................................

18

OPERATING INSTRUCTIONS........................................................................................................................................

19-21

Lighting & Operating Label .....................................................................................................................................

19

Temperature Regulation .........................................................................................................................................

20

Operating the Temperature Control System ...........................................................................................................

21

SERVICE AND ADJUSTMENT .......................................................................................................................................

22-27

Venting System Inspection .....................................................................................................................................

22

Burner Inspection ...................................................................................................................................................

22

Removing the Burner Door Assembly ....................................................................................................................

23

Ultra Low NOx Natural Gas Burner ........................................................................................................................

23

Replacing the Pilot/Thermopile Assembly ..............................................................................................................

23

External Inspection & Cleaning of the Flame Trap .................................................................................................

24

Cleaning the Combustion Chamber and Flame Trap .............................................................................................

24

Replacing the Burner Door Assembly.....................................................................................................................

25

Piezoelectric Igniter System ...................................................................................................................................

25

Testing the Igniter System ......................................................................................................................................

25

Removing and Replacing the Gas Control Valve/Thermostat ................................................................................

26

Housekeeping.........................................................................................................................................................

26

Anode Rod Inspection .......................................................................................................................................

26-27

Temperature-Pressure Relief Valve Operation .......................................................................................................

27

Draining ..................................................................................................................................................................

27

Drain Valve Washer Replacement..........................................................................................................................

27

Service....................................................................................................................................................................

27

TROUBLESHOOTING GUIDE ........................................................................................................................................

28-34

Start Up Conditions ................................................................................................................................................

28

Thermal Expansion ...........................................................................................................................................

28

Strange Sounds ................................................................................................................................................

28

Draft Hood Operation ........................................................................................................................................

28

Condensation ....................................................................................................................................................

29

Smoke/Odor ......................................................................................................................................................

29

Operational Conditions ......................................................................................................................................

29-30

Smelly Odor ......................................................................................................................................................

29

Water Temperature Stacking.............................................................................................................................

29

Air in Hot Water Faucets ...................................................................................................................................

29

Safety Shut-Off.............................................................................................................................................

29,30

Troubleshooting Items .......................................................................................................................................

30-34

PARTS ORDER LIST................................................................................................................................................................

35

4

PRODUCT WARRANTY

12 - YEAR LIMITED WARRANTY ON WATER HEATER

For twelve years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner’s manual instructions and all local applicable plumbing codes, Sears will:

1.Supply free water heater parts for those that are defective in material or workmanship.

2.Supply a free water heater for one that develops a tank leak. See notes below also.

For the second through twelfth year from the purchase date, you must pay the labor cost for installation of parts or water heater.

For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years. During the second year you must pay the labor cost for parts or water heater installation.

If governmental regulations prohibit Sears from furnishing a comparable model replacement water heater under this warranty, Sears will furnish a new water heater of comparable output as permitted by such governmental regulations; however, the Owner will be charged for the additional cost associated with the changes made to comply with such governmental regulations.

Replacements furnished under this warranty do not carry a new warranty and are only covered by the unexpired portion of the original warranty.

1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTY

For the first year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones or a new water heater for one that develops a leak.

WARRANTY SERVICE

To obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663).

This warranty applies only while this product is in use in the United States.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

SEARS BRANDS MANAGEMENT CORPORATION, Hoffman Estates, IL 60179

The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears warrants the installation.

A charge will be made on service calls due to poor or incomplete installation. These include:

a. Adjusting thermostat

b. Condensation

c. Leaks in pipes or fittings

 

 

 

Master Protection Agreements

Congratulations on making a smart purchase. Your new Kenmore® product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation.

The Master Protection Agreement also helps extend the life of your new product. Here’s what the Agreement* includes:

Parts and labor needed to help keep products operating properly under normal use, not just defects. Our coverage goes well beyond the product warranty. No deductibles, no functional failure excluded from coverage— real protection.

Expert service by a force of more than 10,000 authorized Sears service technicians, which means someone you can trust will be working on your product.

Unlimited service calls and nationwide service, as often as you want us, whenever you want us.

“No-lemon” guarantee – replacement of your covered product if four or more product failures occur within twelve months.

Product replacement if your covered product can’t be fixed.

Annual Preventive Maintenance Check at your request – no extra charge.

Fast help by phone – we call it Rapid Resolution – phone support from a Sears representative on all products. Think of us as a “talking owner’s manual.”

$250 Food Loss Protection annually for any food spoilage that is the result of mechanical failure of any covered refrigerator or freezer.

Rental reimbursement if repair of your covered product takes longer than promised.

10% discount off the regular price of any non-covered repair service and related installed parts.

Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online.

The Master Protection Agreement is a risk free purchase. If you cancel for any reason during the product warranty period, we will provide a full refund. Or, a prorated refund anytime after the product warranty period expires. Purchase your Master Protection Agreement today!

Some limitations and exclusions apply. For prices and additional information in the U.S.A. call 1-800-827-6655.

* Coverage in Canada varies on some items. For full details, call Sears Canada at 1-800-361-6665.

Sears Installation Service

For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A. or Canada call 1-800-4-MY-HOME®.

Power surge protection against electrical damage due to power fluctuations.

5

CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears, call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the “Safety Precautions” section first (pages 2 and 3 of this manual) and then read the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE

ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the current edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from the California Office of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA 95811. Instructions can also be downloaded to your computer at WWW.dsa.dgs.ca.gov/Pubs.

Complies with 10 ng/J SCAQMD rule #1121 and districts having equivalent NOx requirements.

PRODUCT SPECIFICATIONS

 

 

 

 

RECOVERY

MINIMUM

 

DIMENSIONS IN

 

TANK

 

INPUT

RATE GALS.

VENT PIPE

DIAMETER

INCHES (mm)

 

CAPACITY IN

TYPE OF

RATE

PER HOUR @

INCHES

INCHES

HEIGHT TO

MODEL NUMBER

GALS (LTRS)

GAS

(Btu/hr)

90°F RISE

(mm)

(mm)

JACKET TOP

153.330280

40 (151)

NATURAL

40,000

41

3” (76) OR 4” (102)

20 (508)

58-3/8 (1483)

153.330290

50 (189)

NATURAL

40,000

41

3” (76) OR 4” (102)

22 (559)

57-3/8 (1457)

6

MATERIALS AND BASIC TOOLS NEEDED

MATERIALS NEEDED

To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.

EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS

(7.6 LITERS) AND

5 GALLONS (18.9 LITERS) CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER.

WAT E R H E AT E R I N S TA L L AT I O N K I T WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) COPPER PLUMBING AND FLEXIBLE GAS CONNECTOR WITH FITTINGS.

METAL DRAIN PANS AVAILABLE IN 20” (508 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 18” (457 mm) OR

LESS, 24” (610mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 22” (559 mm)

OR LESS AND AVAILABLE IN 28” (711 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 26” (660 mm) OR LESS.

BASIC TOOLS

You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local Sears Store.

Pipe Wrenches (2) 14” (356 mm)

Screwdriver

Tin Snips

6’ (1.82 m) Tape or Folding Ruler

Garden Hose

Drill

Pipe Dope or Teflon Tape

SLOT-HEAD SCREWDRIVER

PHILLIPS SCREWDRIVER

ROLL OF TEFLON

TAPE (USE ONLY ON

WATER CONNECTIONS)

DRILL

TIN SNIPS

PIPE DOPE

(SQUEEZE TUBE)

USE FOR WATER AND GAS

CONNECTIONS

GARDEN HOSE

6 FOOT TAPE

PIPE WRENCH

ADDITIONAL TOOLS NEEDED

WHEN SWEAT SOLDERING

Tubing Cutters or Hacksaw

Propane Torch

Soft Solder

Solder Flux

Emery Cloth

Wire Brushes

 

PROPANE

TUBING CUTTER

TORCH

 

ROLL OF

HACKSAW

EMERY CLOTH

3/4” (19 mm) WIRE BRUSH

 

 

 

ROLL OF LEAD-FREE

SOLDER

1/2” (13 mm) WIRE BRUSH

SOFT SOLDER

FLUX

7

Kenmore 153.330280, 153.330290 User Manual

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A

Vent Pipe

J

Drip Leg (Sediment Trap)

S

Flue Baffle

B

Draft Hood

K

Inner Door

T

Gas Control Valve/Thermostat

C

Anode

L

Outer Door

U

Drain Valve

D

Hot Water Outlet

M

Union

V

Pilot and Burner Door Assemblies

E

Outlet

N

Inlet Water Shut-off Valve

W

Flue

F

Flexible Water Connections

O

Cold Water Inlet

X

Metal Drain Pan

G

Gas Supply

P

Inlet Dip Tube

 

 

H

Manual Gas Shut-off Valve

Q

Temperature-Pressure Relief Valve

 

 

I

Ground Joint Union

R

Rating Plate

 

 

* INSTALLINACCORDANCE WITH LOCAL CODES.

* DRIP LEG AS REQUIRED BY LOCAL CODES.

TO VENT

 

 

TERMINATION ON

 

 

ROOF

INSTALL THERMAL EXPANSION

 

 

TANK IF WATER HEATER IS

A

INSTALLED IN A CLOSED

WATER SYSTEM

 

N

O

 

M

 

 

F

 

 

B

 

F

P

VACUUM RELIEF

 

 

D

 

VALVE

 

*INSTALL PER

 

 

LOCAL CODES

E

 

Q

 

 

S

C

R

DISCHARGE PIPE (Do not cap or plug)

G

 

 

 

T

H

V

W

 

 

 

 

 

 

I

 

 

U

6” MAXIMUM

 

 

 

 

 

 

AIR GAP

 

 

 

 

J

 

 

 

 

X

 

K

L

 

 

 

 

 

*ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.

FIGURE 1.

(T) GAS CONTROL VALVE/

THERMOSTAT

VAC

(V) PILOT AND BUNER DOOR ASSEMBLIES

SENSOR WIRES

 

IGNITER

 

WIRE

 

MANIFOLD TUBE

 

PILOT TUBE

THERMOPILE

 

MAIN BURNER

CONNECTORS

 

 

RETAINER

 

CLIP

PILOT

MANIFOLD

COMPONENT

ASSEMBLY

BLOCK

(SEE BELOW)

 

BURNER DOOR

FRONT VIEW

PILOT

ASSEMBLY

TOP VIEW

8

INSTALLATION INSTRUCTIONS

Removing the Old Water Heater

4.

Attach a hose to the water heater

 

 

 

drain valve and put the other end

 

 

 

in a floor drain or outdoors. (See

 

5

 

Figures 2 and 5.) Open the water

 

2

heater drain valve.

 

6

 

 

1

 

 

 

MANUAL GAS

5.

Disconnect the vent pipe from

 

SHUT-OFF VALVE

 

 

 

the draft hood where it connects

 

GROUND

 

to the water heater. In most

 

 

installations the vent pipe can be

FIGURE 5.

JOINT

 

UNION

 

lifted off after any screw or other

 

CHECK WITH

DISCHARGE PIPE

attached devices are removed. Dispose of the draft hood.

The new water heater has a draft hood which must be used

LOCAL UTILITY

(DO NOT CAP

for proper operation.

 

FOR MINIMUM HEIGHT

OR PLUG)

 

 

 

 

3

6.

If you have copper piping to the water heater, the two copper

3” MINIMUM

4

 

water pipes can be cut with a hacksaw approximately four

6” MAXIMUM

 

inches away from where they connect to the water heater.

 

 

 

 

See Figure 6. This will avoid cutting off pipes too short.

 

AIR GAP

 

DRIP LEG

SUITABLE

 

Additional cuts can be made later if necessary. Disconnect the

 

DRAIN

 

temperature-pressure relief valve drain line. When the water

 

 

 

heater is drained, disconnect the hose from the drain valve.

 

FIGURE 2.

 

Close the drain valve. The water heater is now completely

 

 

disconnected and ready to be removed.

1.Turn “OFF” the gas supply to the water heater.

If the main gas line shutoff valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leaveallgasappliances

shut “OFF” until the water heater

installation is completed. See FIGURE 3. Figures 2 and 3.

2.

Open a nearby hot water faucet

 

 

 

until the water is no longer hot.

 

 

When the water has cooled, turn

 

 

“OFF”thewatersupplytothewater

 

 

heater at the water shut off valve

 

 

or water meter. Some installations

 

 

require that the water be turned off

FIGURE 4.

 

to the entire house. See Figures 2

 

 

 

and 4.

 

3.Check again to make sure the gas supply is “OFF” to the water heater. Then disconnect the gas supply connection from the gas control valve.

FIGURE 6.

If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater. See Figure 7. These pieces should be saved since they may be needed when reconnecting the new water heater. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.

FIGURE 7.

9

Facts to Consider About the Location

Carefully choose an indoor location for the new water heater. The placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation.

Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:

Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible.

Selected location must provide adequate clearances for servicing and proper operation of the water heater.

Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable metal drain pan should be installed under the water heater. Metal drain pans are available at your local Sears or hardware store. Such a drain pan must have a minimum length and width of at least 2 inches (51 mm) greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow.

Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a metal drain pan piped to a drain. Unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped metal drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

Sensors mounted in the metal drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.

Sensors mounted in the metal drain pan that turn off the water supply to the entire home when water is detected in the metal drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGEAND UTILITYAREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water heater’s pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area. Even though this water heater is a flammable vapor ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.

Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.

This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

10

Minimum clearances between the water heater and combustible surfaces are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe. See Figure 8. Clearance from the top of the jacket is 8 inches (203 mm) on most models. Note that a lesser dimension may be allowed on some models. Refer to the label attached adjacent to the gas control valve on the water heater.

FIGURE 8.

A gas water heater cannot operate properly without the correct amount of air for combustion. See Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.

FIGURE 9.

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken directly from outdoors (direct vent).

Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.

Insulation Blankets

Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.