Keating Of Chicago Filter System Thermostat User Manual

www.keatingofchicago.com 1-800-KEATING
SERVICE INSTRUCTIONS
7/98
VkngRbltPmp
VIKING REBUILT PUMP KIT
A. To Replace “O” Rings (refer to exploded view)
1. Remove 4 bolts #8. The housing will come apart. Replace “O” rings making sure the “O” ring is in the groove in the housing.
1. The lip seal is located in the bracket Item #1. Using a flat blade screwdriver, knock out the old lip seal. CAUTION: Be careful not to damage the bearings.
2. Using an Arbor Press, press the new lip seal into the bracket #1.
3. Replace all sections of the pump making sure none of the “O” rings are pinched between the sections.
4. Tighten down the 4 bolts by alternating between them.
ITEM DESCRIPTION
1 Bracket, lipseal & bearing section 2 Match ground casing & (2) gears, driver & driven shafts 3 Separation plate & bearing assembly 4 Head and alignment sleeve assembly 6 Lipseal 7 O-ring 8 Assembly capscrews
Typical SG-07
Exploded View
Loading...