Karcher HD1-8-13C User Manual [en, es, fr]

HD 1.8/13 C Ed
English 3
Français 14
Español 27
Register and win!
www.kaercher.com
59659360 03/13
2
IMPORTANT SAFETY IN-
STRUCTIONS
WARNING
When using this product basic precau­tions should always be followed, in­cluding the following:
1 Read all the instructions before us-
ing the product.
2 High pressure jets can be danger-
ous if misused. The jet must not be directed at persons, animals, elec­trical devices, or the unit itself.
3 To reduce the risk of injury, close
supervision is necessary when a product is used near children.
4 Know how to stop the product and
bleed pressures quickly. Be thor­oughly familiar with the controls.
5 Stay alert – watch what you are do-
ing. 6 Wear safety goggles. 7 Do not use acids, alkaline, solvents,
or any flammable material in this
product. These products can cause
physical injuries to the operator and
irreversible damage to the ma-
chine. 8 Do not operate the product when fa-
tigued or under the influence of al-
cohol or drugs. 9 Do not overreach or stand on unsta-
ble support. Keep good footing and
balance at all times. 10 To reduce the risk of electrocution,
keep all connections dry and off the
ground. Do not touch plug with wet
hands. 11 The Trigger Gun Safety Lock pre-
vents the trigger from accidentally
being engaged. This safety feature
DOES NOT lock trigger in the ON
position.
12 Keep operating area clear of all per-
sons.
13 Follow the maintenance instruc-
tions specified in the manual.
14 This product is provided with a
Ground Fault Circuit Interrupter built into the power cord plug. If re­placement of the plug or cord is needed, use only identical replace­ment parts.
15 Risk of Injection or Injury – Do Not
Direct Discharge Stream At Per­sons.
16 Do not use extension cord with this
product.
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least re­sistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and or­dinances.
DANGER
Improper connection of the equipment­grounding conductor can result in a risk of electrocution. Check with a qual­ified electrician or service personnel if you are in doubt as to whether the out­let is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper out­let installed by a qualified electrician. Do not use any type of adapter with this product.
3EN
GROUND FAULT CIRCUIT IN-
TERRUPTER PROTECTION
This Product is supplied with a Ground Fault Circuit Interrupter (GFCI) built into the power cord plug. This device provides additional protection from the risk of electric shock. If power is inter­rupted in the line, the GFCI will auto­matically re-close the circuit to the load after power is restored. Depending on the GFCI model, it may be necessary to manually operate the reset button to restore power to the GFCI load circuit. If the replacement of the plug or cord is needed use identical replacement parts.
WATER SUPPLY
(Cold Water Only)
CAUTION
When connecting the water inlet to the water supply mains, local regulations of your water company must be ob­served. In some areas the unit must not be connected directly to the public drinking water supply. This is to ensure that there is no feedback of chemicals into the water supply. Direct connec­tion via a receiver tank or backflow pre­venter, for example, is permitted. Dirt in the feed water will damage the unit. To avoid this risk, we recommend fitting a water filter.
Garden hose must be at least 3/4
inch in diameter.
Flow rate of water supply must not
fall below 2.5 GPM (gallons per
minute).
Flow rate can be determined by
running the water for one minute
into an empty 5-gallon container.
The water supply temperature must
not exceed 140°F/60°C.
Never use the pressure washer to
draw in water contaminated with solvents, e.g. paint thinners, gaso­line, oil, etc.
Always prevent debris from being
drawn into the unit by using a clean water source. Use additional water filter.
CANADA
WARNING
Do not spray electrical apparatus and wiring.
Do not use with flammable liquids and toxic chemicals. Injection hazard: equipment can cause serious injury if the spray penetrates the skin. do not point the gun at anyone or any part of the body. In case of pen­etration seek medical aid immediately.
This system is capable of producing 9000 kPa/1300 PSI. To avoid rupture and injury, do not operate this pump with components rated less than 9000 kPa/1300 PSI working pressure (in­cluding but not limited to spray guns, hose and hose connections).
Before servicing, cleaning or removing any parts, shut off power and relieve pressure.
EXTENSION CORDS
Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from the product. Use only ex­tension cords that are intended for out­door use. These extension cords are identified by a marking "Acceptable for use with out-door appliances: store in­doors while not in use." Use only ex­tension cords having an electrical rating not less than the rating of the product. Do not use damaged exten-
4 EN
sion cords. Examine extension cord before using and replace if damaged. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat and sharp edges. Always disconnect the exten­sion cord from the receptacle before disconnecting the product from the ex­tension cord. If you are using an extension cord, it should always be completely unwound from the cable drum. Up to 100 ft = 12/3 AWG.
WARNING
To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands.
SAVE THESE INSTRUCTIONS!
Please read and comply with
these original instructions prior to the initial operation of your ap­pliance and store them for later use or subsequent owners.
Contents
Device elements . . . . . . . . . EN . . 3
Safety instructions . . . . . . . . EN . . 4
Proper use. . . . . . . . . . . . . . EN . . 4
Safety Devices . . . . . . . . . . EN . . 4
Environmental protection. . . EN . . 5
Before Startup . . . . . . . . . . . EN . . 5
Start up . . . . . . . . . . . . . . . . EN . . 5
Operation. . . . . . . . . . . . . . . EN . . 7
Transport . . . . . . . . . . . . . . . EN . . 8
Storage . . . . . . . . . . . . . . . . EN . . 8
Maintenance and care. . . . . EN . . 9
Troubleshooting. . . . . . . . . . EN . . 9
Accessories and Spare Parts EN . 10
Warranty . . . . . . . . . . . . . . . EN . 10
Technical specifications. . . . EN . 11
Device elements
Please unfold the front picture side 1 Storage compartment for nozzles
2 Handle 3 High pressure connection 4 Water connection 5 Oil level indicator 6 Oil tank 7 Cover 8 Power switch 9 Fastening screw for device hood 10 Storage compartment for hoses 11 Trigger gun storage clip 12 Nozzle 13 Marking of the nozzle 14 Spray lance 15 Hand blowing gun 16 Safety lever 17 Lever for hand spray gun 18 High pressure hose
5EN
19 Push handle 20 Cable clamp 21 Clamping screw for pushing handle 22 Detergent suction hose with filter 23 Dosage valve for detergent 24 Accessory compartment
Safety instructions
Before first start-up it is definitely
necessary to read the operating in­structions and safety indications Nr.
5.951-949!
Please follow the national rules and
regulations for fuel spray jets of the respective country.
Please follow the national rules and
regulations for accident prevention of the respective country. Fuel spray jets must be tested regularly and the results of these tests must be documented in writing.
Symbols in the operating in-
structions
Danger
Immediate danger that can cause se­vere injury or even death.
Warning
Possible hazardous situation that could lead to severe injury or even death.
Caution
Possible hazardous situation that could lead to mild injury to persons or damage to property.
Symbols on the machine
High-pressure jets can be dangerous if improperly
used. The jet may not be di­rected at persons, animals, live electri­cal equipment or at the appliance itself.
According to the applicable regulations, the appliance
must never be used on the drinking water net without a system separator. Use a suitable system sep­arator manufactured by Kärcher; or, as an alternative, a system separator as per EN 12729 Type BA. Water flowing through a system sepa­rator is considered non-drinkable.
Proper use
Use this high pressure cleaner exclu­sively for
Cleaning using low pressure jet and
detergent (for e.g. for cleaning ma­chines, cars, buildings, tools),
For cleaning using high pressure jet
without detergent (for e.g. for clean­ing facades, terraces, garden appli­ances).
For stubborn dirt, we recommend the use of the dirt blaster as a special ac­cessory.
Safety Devices
Safety devices serve for the protection of the user and must not be put out of operation or bypassed with respect to their function.
Pressure switch
If the lever on the trigger gun is re­leased the pressure switch turns off the pump, the high-pressure jet is stopped. If the lever is pulled the pump is turned on again. The overflow valve and pressure switch are set and sealed at the facto­ry. Setting only by customer service.
6 EN
Environmental protection
The packaging material can be recycled. Please do not throw the packaging materi­al into household waste; please send it for recycling.
Old appliances contain valuable materials that can be recycled; these should be sent for recycling. Batter­ies, oil, and similar sub­stances must not enter the environment. Please dis­pose of your old appliances using appropriate collection systems.
Please do not release engine oil, fuel oil, diesel and petrol into the environ­ment Protect the ground and dispose of used oil in an environmentally­clean manner.
Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH
Before Startup
Check oil level
Read the oil level display when the
device is not running. The oil level must be above the two pointers.
Activate deaeration of oil con-
tainer
Unscrew the fastening screws of
the device hood; remove the device hood.
Cut off tip of oil container coverFasten the device hood.
Attaching the Accessories
Mount the nozzle on the spray pipe
(markings on the adjustment ring at the top).
Connect ray tube to hand spray gunLever out the safety clip of the
handspray gun using a screw-driver (Picture A).
Place the hand-spray gun upside
down and insert the end of the high pressure hose till the end. Ensure that the lose disc falls right below on the hose end (Picture B).
Press the safety clip back into the
hand-spray gun. The hose can be pulled out max. 1 mm if it has been installed correctly. Otherwise, it means the disc has been installed wrongly (picture C).
Loosen the clamps of the pushing
handle.
Adjust the handle to the desired
height.
Tighten the clamps of the pushing
handle.
Fasten the high pressure hose to
the high pressure connection.
Start up
Electrical connection
Danger
Danger of injury by electric shock. The appliance may only be connected to an electrical supply which has been installed in accordance with IEC
60364. The voltage indicated on the type plate must correspond to the voltage of the electrical source. The minimum fuse rating required at the socket outlet is (see technical specifications). The appliance should always be con­nected to the electrical mains using a
7EN
plug. It is forbidden to permanently connect the appliance to the power supply. The plug is only for mains sep­aration. Check the power cord with mains plug for damage before every use. If the power cord is damaged, please ar­range immediately for the exchange by an authorized customer service or a skilled electrician. The plug and coupling of the extension cable used must be watertight. Use the extension cord that has an ad­equate cross-section (see "Technical Data") and unwind it fully from the ca­ble drum. Unsuitable extension cables can be hazardous. Only use extension cables outdoors which have been approved for this purpose and labelled with a suf­ficient cable cross section:
For connection values, see type plate/ technical data.
GFCI INSTRUCTIONS
STEP 1: Plug the Ground Fault Cir-
cuit Interrupter (GFCI) into a work­ing outlet.
STEP 2: Press ’’TEST’’, then press
’’RESET’’ to assure proper connec­tion to power.
Note: The actual appearance of the GFCI may be different from this illus­tration.
Water connection
Connection to the water supply
Warning
Observe regulations of water supplier. According to the applicable regulations, the appliance must never be used on the drinking water supply without a system separator. Use a suitable system sep­arator manufactured by KÄRCHER; or, as an alternative, a system separator as per EN 12729 Type BA. Water flow­ing through a system separator is con­sidered non-drinkable.
Caution
Always connect the system separator to the water supply, never directly to the appliance!
For connection values refer to techni­cal specifications
Connect the supply hose (max
length 7.5 m, minimum diameter 1/ 2“) to the water connection point of the machine and at the water sup­ply point (for e.g. a tap).
Note
The supply hose is not included.
Open the water supply.
Drawing in water from open reservoirs
Screw the suction hose with filter
(order no. 4.440-238.0) to the water connection.
Deaerate the appliance:
Unscrew the nozzle. Switch on the appliance and let it
run until the water exiting is bubble­free.
At the end let the appliance run for approx. 10 seconds - then switch off. Repeat the procedure for a cou­ple of times.
Switch off the appliance and fit the
nozzle again.
8 EN
Operation
Danger
Risk of explosion! Do not spray flammable liquids. If the appliance is used in hazardous areas (e.g. filling stations) the corre­sponding safety provisions must be ob­served.
Danger
Long hours of using the appliance can cause circulation problems in the hands on account of vibrations.
It is not possible to specify a generally valid operation time, since this de­pends on several factors:
Proneness to blood circulation defi-
ciencies (cold, numb fingers).
Low ambient temperature. Wear
warm gloves to protect hands.
A firm grip impedes blood circula-
tion.
Continuous operation is worse than
an operation interrupted by pauses.
In case of regular, long-term operation of the device and in case of repeated occurrence of the symptoms (e.g. cold, numb fingers) please consult a physi­cian.
Caution
Clean engines only at places with cor­responding oil separators (environ­mental safety). Risk of blocking. Place the nozzles in the accessory compartment with their joint pointing upward.
High pressure operation
Note
The appliance is equipped with a pres­sure switch. The motor starts up only when the lever of the pistol is pulled.
Set the appliance switch to "I".
Unlock the hand-spray gun and pull
the lever of the gun.
Select spray type
Close the hand spray gun. Turn the casing of the nozzle till the
desired symbol matches the mark­ing.
High pressure circular spray (0°) for specially stubborn dirt
Flat low pressure spray (CHEM) for operating us­ing detergents or cleaning at low pressure.
High pressure flat spray (25°) for large dirt areas
Operation with detergent
Warning
Unsuitable detergents can cause dam­age to the appliance and to the object to be cleaned. Use only those deter­gents that have been approved by Kärcher. Observe the dosage and oth­er instructions provided with these de­tergents. For considerate treatment of the environment use detergent eco­nomically. Follow the safety instructions for using detergents.
Kärcher detergents ensure smooth functioning. Please consult us or ask for our catalogue or our detergent in­formation sheets.
Take out detergent suck hose.Suspend end of suction hose in a
container filled with detergent.
Set nozzle to "CHEM". Set dosing value for detergent to
the desired concentration.
9EN
Recommended cleaning method
Spray the detergent sparingly on the dry surface and allow it to react, but not to dry.
Spray off loosened dirt with the
high-pressure ray.
After operations, dip the filter in
clear water. Turn the dosing valve to the highest detergent concentra­tion. Start the appliance and rinse for one minute.
Interrupting operation
Release the lever of the hand-spray
gun; the device will switch off.
Release again the lever of the
hand-spray gun; the device will switch on again.
Turn off the appliance
Set the appliance switch to "0".Disconnect the mains plug from the
socket.
Shut off water supply.Activate hand spray gun until de-
vice is pressure-less.
Press the safety lever of the hand-
spray gun to secure the lever of the pistol against being released acci­dentally.
Storing the Appliance
Insert the hand-spray gun in the
holder.
Wind up the high-pressure hose
and hang it over the hose storage.
Wind the connection cable around
the cable holder.
Fasten the plug with the mounted
clip.
Frost protection
Warning
Frost will destroy the not completely water drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free place:
Drain water. Pump in conventional frost protec-
tion agents through the appliance.
Note
Use normal glycol-based anti-freezing agents for automobiles. Observe handling instructions of the anti-freeze agent manufacturer.
Operate device for max. 1 minute
until the pump and conduits are empty.
Transport
Caution
Risk of injury and damage! Observe the weight of the appliance when you transport it.
Pull the device behind you at the
handle for transporting it over lon­ger distances.
Push the handle downward to carry
the appliance. To carry, hold the ap­pliance at the handles and not at the pushing handle.
When transporting in vehicles, secure the appliance according to the guide­lines from slipping and tipping over.
Storage
Caution
Risk of injury and damage! Note the weight of the appliance in case of stor­age.
This appliance must only be stored in interior rooms.
10 EN
Maintenance and care
Danger
Risk of injury by inadvertent startup of appliance and electrical shock. First pull out the plug from the mains before carrying out any tasks on the machine.
Note
Please dispose off used oil only in the collection points provided for them. Please hand over old oil, if any, only at such places. Polluting the environ­ment with used oil is a punishable of­fence.
Safety inspection/ maintenance
contract
You can sign with your dealer a con­tract for regular safety inspection or even sign a maintenance contract. Please take advice on this matter.
Before each use
Check connection cable for damag-
es (risk of electrical shock); get the damaged connection cable re­placed immediately by an autho­rised customer service person/ electrician.
Check the high pressure hose for
damages (risk of bursting). Please arrange for the immediate
exchange of a damaged high-pres­sure hose.
Check appliance (pump) for leaks.
3 drops per minute are permitted and can come out from the lower side of the appliance. Call Custom­er Service if there is heavy leakage.
Weekly
Check oil level Please contact Cus-
tomer Service immediately if the oil is milky (water in oil).
Clean the sieve in the water con-
nection.
Clean filter at the detergent suck
hose.
monthly or after 500 operating
hours
Oil change.
Oil change
Note
See "Technical Details" for details of oil quantity and type.
Unscrew the fastening screws of
the device hood; remove the device hood.
Remove the lid of the oil container.Tilt the appliance forward.Drain the oil in a collection basin. Fill in new oil slowly; air bubbles
should go out.
Attach the lid of the oil container.Fasten the device hood.
Troubleshooting
Danger
Risk of injury by inadvertent startup of appliance and electrical shock. First pull out the plug from the mains before carrying out any tasks on the machine. Get the electrical components checked and repaired only by authorised cus­tomer service persons. Contact an authorised customer ser­vice person in case of problems not mentioned in this chapter or if you are in doubt or when you have been explic­itly asked to do so.
11EN
Appliance is not running
Check connection cable for damag­es.
Check the supply voltage.Call Customer Service in case of
electrical defects.
Pressure does not build up in the
appliance
Set nozzle to "High pressure". Clean the nozzle.Replace the nozzle.Deaerate the appliance (see "Start-
up")
Check water supply level (refer to
technical data).
Clean the sieve in the water con-
nection.
Check all inlet pipes to the pump. Contact Customer Service if need-
ed.
Pump leaky
3 drops per minute are permitted and can come out from the lower side of the appliance. Call Customer Service if there is heavy leakage.
With stronger leak, have device
checked by customer service.
Pump is vibrating
Check suction pipes for water and
detergent and ensure that they are leak-proof.
Close dosing valve for detergent to
operate the machine without deter­gent.
Deaerate the appliance (see "Start-
up")
Contact Customer Service if need-
ed.
Detergent is not getting sucked
in
Set nozzle to "CHEM". Check/ clean detergent suction
hose with filter.
Open or check/clean detergent
dosing valve.
Contact Customer Service if need-
ed.
Accessories and Spare Parts
Only use accessories and spare
parts which have been approved by the manufacturer. The exclusive use of original accessories and original spare parts ensures that the appliance can be operated safely and trouble free.
At the end of the operating instruc-
tions you will find a selected list of spare parts that are often required.
For additional information about
spare parts, please go to the Ser­vice section at www.kaercher.com.
Warranty
The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provid­ed that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest au­thorized Customer Service centre. Please submit the proof of purchase.
12 EN
– 10
Loading...
+ 28 hidden pages