Jungheinrich ETV213 User Manual

õUNGHEINRICH Event Messages
F
Function group
Event Messages
03.151
G
This display units shows a four-digit event message for every
Z
event. Trucks that only use one luminous display (e.g. LED) show the event through a flashing code (see "Display System”). Each event message is also stored in the master logbook. The master logbook describes the event in more detail through the sub index behind the event message (FEXX).
Event numbering display
F E XX S F Function group; E Event group
XX Event number S Sub index
The first two characters “F, E” refer to the category. The middle
Z
two digits “XX” refer to the event. From these two digits the range:
•1 to 50 describes standard events (uniform basic events) which can occur in any function group.
•51 to 99 describes specific events.
The event is described in further detail through the last characters “S” (single digit/multi-digit). This process ensures that a unique number is assigned to each event. Example:
E
XX
S Sub-index
Event group
Event number
Sub-division of function group "F"
System: Overlapping functions that cannot be assigned to any other
0
function group)
Example: seat switch / deadman switch or master controller 1Travel 2Hydraulics (load handling) 3Steering and travel 4Displays/controls, interface 5Charger (either on-board or external charger) 6Reserved 7Reserved 8Reserved
Special functions
9
Example: ISM
ï í ðë ï
õUNGHEINRICH Event Messages
Sub-division of event group “E”
Display system
03.152
G
Fault reset or
0
no fault General fault / additional functions
1
Example: Logic error, e.g. both directions selected simultaneously
Current
2
(input interface, device-internal, output interface) Voltage
3
(input interface, device-internal, output interface)
4Temperature
Hardware
5
Example: Output transformer short circuit, EEPROM not responding, …
Software (internal software, application software, data record /
6
parameters) Example:
7Additional modules
EEPROM data error
The system distinguishes between:
•event messages caused by operator errors.
•event messages caused by truck errors.
For operator errors there are three versions that can be displayed
in the truck depending on the display unit options.
•Event number display (e.g. CANDIS)
•Pictogram display
•Text message display
For truck errors the event number and possibly a fault graphic icon
(e.g. service key) will also be displayed.
Trucks that only use one luminous display (e.g. LED) use the
following flashing code:
•Each character of the four-digit event number is shown with a 2 Hz / 0.5 sec frequency (flashing).
The figure “zero” is displayed by flashing ten times.
Z
•After each character of the four-digit event message there is a pause (LED off) of one second.
•After the complete four-digit event message a 3 second pause (LED off) is set.
8CAN monitoring
External fault
9
Example: ISM
õUNGHEINRICH Event Messages
03.153
Description / cause / action and effects
The following table lists the event message with a description / cause / action and effect.
Z
Each event group (E) with the corresponding event number (XX) can be combined with different function groups (F), hence in the following table the placeholder “F” is used for the first character “F” of the four-digit event number. It also shows the operating status when the event occurred:
Operating status Explanation
Occurs during / directly after truck power up
Bootloader
(basic initialisation of components, possible change to flash mode). Example: Checking the RAM / ROM (memory check)
G
System start
Self test
OperationOccurs during operation
System endOccurs during truck power-down (correct powering down of components, …)
UndefinedCan occur at any time
Occurs during installation of operating software of individual components. Example: correct hardware installed, ...
Occurs during the self-test of each component, as coordinated by the master
The main contactor is then closed
õUNGHEINRICH Event Messages
“Event messages” table
03.154
G
F E XX SOperational
Status
_1011System start
_1
_12Self test
02
_13Self test
_14
1Self test
Self test
Operation
DescriptionCause / Triggering EventAction
Supply via unexpected key switch input
Contact closed instead of open
Contact open instead of closed
Main contactor permanently on
Main contactor feedback input implausible
Evaluation of three key switch inputs. Possible encodings are 1, 2 or 4, otherwise the event message is triggered.
On power-up the capacitor voltage should be one volt (1V) below the battery voltage.
When the main contactor has switched on the capacitor voltage should be the same as the battery voltage (within 500msec.), otherwise the event message is produced.
An attempt is being made to open the main contactor. The event message is triggered if the monitoring system detects that the main contactor has not opened after T > time limit.
Feedback signal from main contactor status implausible with main contactor control (error activated after limit time)
-Check key switch input connection against the wiring diagram;
-Replace controller;
-Test the main contactor output of the controller;
-Check wire connection;
-Replace contactor;
-Test the main contactor output of the controller;
-Check wire connection;
-Replace contactor;
-Replace controller;
Lithium-ion battery 24V/110Ah (in the case of repeated faults):
-Check the harness of the lithium-ion battery and replace if necessary;
-Replace battery contactor;
-Replace battery management system (BMS);
-Test the main contactor output of the controller;
-Check wire connection;
-Replace contactor;
_103
1Self test
2Self test
3Self test
Output transformer faulty (phase U)
Output transformer faulty (phase V)
Output transformer faulty (phase W)
The semi-jumpers 1, 2 and 3 are controlled in turned for 50 msec at 25% PWM (pulse width modulation) when the output transformer is closed (“Output transformer deactivated” signal). The event message is issued if at the end of the 50msec period of the respective phase the following applies: V
Phase_X
< (V
capacitor
/ 2) - 25%
-Replace controller;
õUNGHEINRICH Event Messages
03.155
G
F E XX SOperational
DescriptionCause / Triggering EventAction
Status
1Self test
_104
2Self test
3Self test
_1044Operation
Output transformer faulty (phase U)
Output transformer faulty (phase V)
Output transformer faulty (phase W)
Error bit set for power stageID
_1051Self testMotor cutout
Semi-jumpers 1, 2 and 3 are controlled in turn for 50msec at 25% PWM (pulse width modulation). The event message is issued if at the end of the 50msec period of the respective phase the following applies: V
Phase_X
V
Phase_X
> (V < (V
capacitor capacitor
/ 4) 25% or / 4) - 25%
"Error, power stage ID : The power card of the power stage can only obtain faulty information (ID) about the identity and hence suitability of the card for the intended powering of the operating system when the error bit is set"
Semi-jumpers 1, 2 and 3 are controlled in turn for 50msec at 25% PWM (pulse width modulation). The event message is issued if at the end of the 50msec period of at least one of the two non-controlled phases the following applies: V
Phase
V
Phase
> (V < (V
capacitor capacitor
/ 4) 25% or / 4) - 25%
-Replace controller;
-Replace controller;
-Check motor connection wire (wire breakage);
-Replace motor;
_1052Self test
"Combi controller behaviour for non-controlled power stages" logic implausible
Semi-jumpers 1, 2 and 3 of a combi controller power partare controlled in turn for 50msec at 25% PWM (pulsewidth modulation). The event message is issued if at the end of the 50msec period of at least one of the semi-jumpers of the other power part the following applies: V
Phase_X
V
Phase_X
> (V < (V
capacitor capacitor
/ 2) + 15% or / 2) - 15%
-Switch the truck off and on again;
-Check the motor connections;
-Check for a short between two power stages ormotors;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.156
G
F E XX SOperational
Status
_1061Operation
_1062Operation
_1063Operation
DescriptionCause / Triggering EventAction
Safety switch inputs implausible
Deadman switch inputs implausible
Slack-chain switch inputs implausible
The safety switch consists of a NC and a NO contact. When the button is pressed both contacts connect simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation combinations 0/0 and 1/1 (500msec.) trigger the event message. For a valid combination (0/1 or 1/0, 500msec) the event message and the truck response are reset. For an implausible condition the seat switch is considered to beopen (-> the truck brakes with the coasting ramp).
During operation combinations 0/0 and 1/1 trigger the event message. The event message can only be reset by resetting the truck. The activation limit is 2000msec.
During operation combinations 0/0 and 1/1 trigger the event message. For a valid combination (0/1 or 1/0), theevent and the truck response are reset. The activation limit is 1000msec.
-Check safety switch wire connection;
-Check safety switch;
-Replace safety switch;
Safety switches can include:
Z
- Deadman (foot switch),
- Seat switch,
- Tiller switch.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1064Operation
_1065Operation
Cabin gate inputs implausible
Optional cabin gate inputs implausible
During operation combinations 0/0 and 1/1 trigger the event message. For a valid combination (0/1 or 1/0), theevent and the truck response are reset. The activation limit is 2000msec.
During operation combinations 0/0 and 1/1 trigger the event message. For a valid combination (0/1 or 1/0), theevent and the truck response are reset. The activation limit is 2000msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.157
G
F E XX SOperational
Status
_1066Operation
_1067Operation
_1068Operation
_1069Operation
DescriptionCause / Triggering EventAction
Sideshift index inputs implausible
Aisle recognition right inputs implausible
Aisle recognition left inputs implausible
Load handling inputs: no signal
During operation combinations 0/0 and 1/1 trigger the event message after a traverse path of more than 30mm. For a valid combination (0/1 or 1/0), the event and the truck response are reset. The activation limit is 0msec.
During operation combinations 0/1 and 1/0 trigger the event message after the truck has travelled more than 100mm. The event message can only be reset by resetting the truck. The activation limit is 100msec.
During operation combinations 0/1 and 1/0 trigger the event message after the truck has travelled more than 100mm. The event message can only be reset by resetting the truck. The activation limit is 100msec.
During operation combinations 0/0 and 1/1 trigger the event message. The event message can only be reset by resetting the truck. The activation limit is 2000 msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_10610Operation
_10611Operation
Load sensing inputs: no signal
Logic test: signal at working platform raised inputs improbable
If the weight display > 300 kg the load sensors must be applied. The event message can only be reset by resetting the truck. The activation limit is 2000 msec.
During operation combinations 0/0 and 1/1 trigger the event message. The event message can only be reset by resetting the truck. The activation limit is 2000 msec.
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.158
G
F E XX SOperational
Status
_10612Operation
_10613Operation
_10614Operation
_10615Operation
DescriptionCause / Triggering EventAction
Logic test: signal at left/right gate lock inputs improbable
Logic test: No signal for gate lock despite gate lock being applied
Logic test: Signal for gate lock present despite gate lock not being applied
Logic test: No signal for gate lock despite the lift mechanism being above the set height
During operation combinations 0/1 and 1/0 trigger the event message. The activation limit is 2000 msec.
During operation no feedback triggers the message when applied. The activation limit is 2000 msec.
During operation a feedback triggers the message without being applied. The activation limit is 2000 msec.
During operation no feedback triggers the message when lift mechanism is above the set height. The activation limit is 2000 msec.
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Test sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1071Operation
Operator protection switch inputs implausible
The body protection switch consists of a NC and a NO contact. When the button is pressed both contacts connect simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation combinations 0/0 and 1/1 (500msec.) trigger the event message. For a valid combination (0/1 or 1/0, 500msec) the event message and the truck response are reset.
-Check wire connections;
-Check operator protection switch;
-Replace operator protection switch;
õUNGHEINRICH Event Messages
03.159
G
F E XX SOperational
Status
_1072Operation
_1081Operation
_1082Operation
DescriptionCause / Triggering EventAction
Acknowledge button inputs implausible
Touch mode switch inputs implausible
"Crawl speed redundant inputs" logic implausible
During operation combinations 0/0 and 1/1 (500 msec.) trigger the event message. For a valid combination (0/1 or 1/0, 500msecs) the event and the truck response are reset.
The touch mode button consists of a NC and a NO contact. When the button is pressed both contacts connect simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation combinations 0/0 and 1/1 (500msec.) trigger the event message. For a valid combination (0/1 or 1/0, 500msec) the event message and the truck response are reset.
The "inching" button consists of a NC and a NO contact. When the button is pressed both contacts switch simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation the combinations 0/0 and 1/1 (switched for 500msec.) activate the event message. For a valid combination (0/1 or 1/0, switched for 500 msec.) the event and truck response are reset. The status is assessed as an actuated status (adjustable inching speed active)
-Check wire connections;
-Check button;
-Replace button;
-Check wire connection;
-Check touch mode button;
-Replace touch mode button;
-Check wire connections;
-Check crawl speed button;
-Replace crawl speed button;
_1083Operation
“Stop" button redundant inputs” logic improbable
The "Stop" button consists of an NC and an NO contact. When the button is pressed both contacts switch simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation the combinations 0/0 and 1/1 (500msec) trigger the event message. For a valid combination (0/1 or 1/0, 500msec) the event message and the truck's response are reset.
-Check parameter reading (side pedestrian mode activated?);
-Check wire connections;
-Press "Stop" button;
-Replace "Stop" button;
õUNGHEINRICH Event Messages
03.1510
G
F E XX SOperational
Status
_1084
_1085
Self test
Operation
Self test
Operation
DescriptionCause / Triggering EventAction
“Handbrake lever redundant inputs” logic implausible
“Parking brake switch redundant inputs” logic implausible
The "handbrake lever" switch consists of a NC and a NO contact. When the button is pressed both contacts switch simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation the combinations 0/0 and 1/1 (switched for 500msec.) activate the event message. For a valid combination (0/1 or 1/0, switched for 500msec) the event message and the truck's response are reset.
The "parking brake" switch consists of a NC and a NO contact. When the button is pressed both contacts switch simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation the combinations 0/0 and 1/1 (switched for 500msec.) activate the event message. For a valid combination (0/1 or 1/0, switched for 500 msec.) the event message and the truck's response are reset.
-Check wire connections;
-Check “handbrake lever” switch;
-Replace “handbrake lever” switch;
-Check wire connections;
-Check options keypad;
-Replace options keypad:
_1091Operation
Weigher button inputs implausible
The weigher button consists of a NC and a NO contact. When the button is pressed both contacts connect simultaneously. As a result, only the 0/1 and 1/0 combinations should occur. During operation combinations 0/0 and 1/1 (500msec.) trigger the event message. For a valid combination (0/1 or 1/0, 500msec) the event message and the truck response are reset.
-Check wire connection;
-Check weigher button;
-Replace weigher button;
õUNGHEINRICH Event Messages
03.1511
G
F E XX SOperational
Status
_1101Operation
_1102Operation
_1111Operation
_1112Operation
DescriptionCause / Triggering EventAction
Lift/lower digital setpoints are invalid
Lift/lower analog setpoints are invalid
Braking setpoint and release contact implausible
Braking setpoint and release contact implausible
During operation the combination 1/1 for both buttons pressed simultaneously for 500 msec triggers the following event message. For a valid combination (0/0, 0/1 or 1/0 [button not pressed / only one button pressed]; 500msec) the event message and the truck response are reset.
During operation the limits for 1/1 [both buttons pressed simultaneously] for 500 msec have been exceeded. For a valid combination (0/0, 0/1 or 1/0 [button not pressed / only one button pressed]; 500msec) the event message and the truck response are reset.
The event message is triggered if the following applies for T = 250msec: V
brake pedal
Logic signal release contact = 1 The event message is triggered if the following applies
for T = 250msec: V
brake pedal
Logic signal release contact = 0
< 12.5% and
> 25% and
-Check wire connection;
-Check button;
-Replace button;
-Check wire connection;
-Check button;
-Replace button;
-Check wire connection;
-Check pedal power supply;
-Replace pedal;
-Replace signal-evaluating controller;
-Check wire connection;
-Check pedal power supply;
-Replace pedal;
-Replace signal-evaluating controller;
_1113Operation
_1114Operation
Braking setpoint and full brake contact implausible
Braking setpoint and full brake contact implausible
The event message is triggered if the following applies for T = 250msec: V
brake pedal
Logic signal full brake contact = 1 The event message is triggered if the following applies
for T = 250msec: V
brake pedal
Logic signal full brake contact = 0
< 65% and
> 80% and
-Check wire connection;
-Check pedal power supply;
-Replace pedal;
-Replace signal-evaluating controller;
-Check wire connection;
-Check pedal power supply;
-Replace pedal;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.1512
G
F E XX SOperational
Status
_1115Operation
_1116Operation
_1117Operation
_1121Operation
_1122Operation
DescriptionCause / Triggering EventAction
Combination "brake setpoint" against brake pressure invalid (movement without brake pressure)
Combination "brake setpoint" against brake pressure invalid (brake pressure without movement)
Sum of the voltages "Braking 1 setpoint" to "Braking 2 setpoint" invalid
Travel setpoint and release contact invalid
Travel setpoint and release contact invalid
The event message is triggered if for T = 250 ms the following applies:
•V
brake pedal
> 80% and brake pressure < 40bar
The event message is triggered if for T = 250 ms the following applies:
•V
brake pedal
< 20% (> 7 volt ) and brake pressure
>20bar
The event message is triggered if for T = 250 ms the following applies:
•V
brake pedal
•V
brake pedal
1 + V 1 + V
brake pedal brake pedal
2 > 5.5V or 2 < 4.5V
The event message is triggered if the following applies for T = 250msec: V
accelerator pedal
< 12.5% and
Logic signal release contact = 1 The event message is triggered if the following applies
for T = 250msec: V
accelerator pedal
> 25 % and
Logic signal release contact = 0
-Check brake fluid level;
-Check proximity sensor;
-Check pressure sensors;
-Check brake fluid level;
-Check proximity sensor;
-Check pressure sensors;
-Check the cable connection;
-check accelerator-pedal power supply / tiller head power supply;
-replace accelerator pedal / tiller arm;
-replace the controller that is evaluating the signal;
-Check wire connection;
-Check accelerator pedal/tiller arm power supply;
-Replace accelerator pedal / tiller arm;
-Replace signal-evaluating controller;
-Check wire connection;
-Check accelerator pedal/tiller arm power supply;
-Replace accelerator pedal / tiller arm;
-Replace signal-evaluating controller;
_1123Operation
Total voltage "Travel1 setpoint" to "Travel2 setpoint" invalid
The event message is triggered if for T = 250 ms the following applies:
•V
brake pedal
V
brake pedal
1 + V
brake pedal
2 < 4.5V
2 > 5.5V or V
brake pedal
1 +
-Check wire connection;
-Check accelerator pedal/tiller arm power supply;
-Replace accelerator pedal / tiller arm;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.1513
G
F E XX SOperational
Status
_1131Operation
_1132Operation
_1141Self test
DescriptionCause / Triggering EventAction
Travel direction 1 and travel direction 2 invalid
Direction setting signal improbable (direction sensor)
Motor speed signal implausible
During operation the combination 1/1 [both travel direction switch / button / twin pedal pressed] for 500 msec triggers the following event message. For a valid combination (0/0, 0/1 or 1/0 [travel direction switch/button/twin pedal not pressed or only one travel direction switch/button/twin pedal pressed]; 500msec) the event message and the truck response are reset.
If more than one direction sensor is installed: While the truck is travelling, the system monitors if by mistake more than one direction sensor (travel direction switch on pilot, external direction sensor or twin pedal) is installed. If this is the case, the event is triggered
Logic test: after a short period of motor control, the speed sensor does not supply any signals
-Check wire connection;
-Check travel direction switch/button/twin pedal;
-Check travel direction switch/button/twin pedal;
-Replace signal-evaluating controller;
-Check parameter settings;
-Check installed accelerator (hardware);
-Check installed Pilots (hardware);
-Check travel direction switch / button / twin pedal;
-Replace travel direction switch / button / twin pedal;
-Rectify mechanical blockage of drive system;
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
_1151Operation
_1152Operation
_1161OperationIrregular speed signal
Motor powers without setpoint
Motor powers without setpoint
Motor powered for 500 msec without setpoint. Logic: implausible status in controller
Convergence problem in monitor for the motor speed Logic: implausible status in monitor
Jump from n_motor > 10% to n_motor < 1% and for T = 80 msec. the following applies: n_motor < 1%
-Check motor connections;
-Check motor model, replace if necessary;
-Check motor connections;
-Check motor model, replace if necessary;
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.1514
G
F E XX SOperational
Status
_1162Operation
DescriptionCause / Triggering EventAction
Irregular speed signal (large jump in evaluated speed signal)
Incrementer damaged The AC-3 Power Control (U8) has identified the sensor bearing as being damaged. The AC-3 Power Control (U8) monitors sensor to ensure the impulse wires are single-channel, and to check for sudden changes in the pulse rate and for constant power supply. Sensor is damaged (broken wire, short circuit, incorrect pulses); Operating system wrongly flags a fault; AC-3 Power Control component (sensor bearing control) is faulty Jump from n_Motor> 10 % to n_Motor< 1 % and For T = 80 msec.: n_motor< 1%
No signals from incremental transmitter 1B5.
-Check incrementer signals with multimeter;
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
-Manually move the shuttle to the channel start, remove any blockage (use recovery vehicle);
-Reduce load on shuttle;
-Drive: check setpoint specification, motor controller 9U19 and drive motor including carbon brushes and incremental transmitter 1B5;
-Check wire connection;
-If the shuttle is overloaded, increase the travel speed;
_1163Operation
_1171Operation
Implausible value for the engine-speed signal
A speed sensor channel does not pulse
Engine control unit is sending an incorrect value for the engine-speed signal.
Both speed sensor tracks are counted. When the first deviation limit is reached the system waits for a feasible signal from the suspected broken track. When the second limit is reached the event message is generated.
-Check speed-sensor power supply;
-Check the wiring;
-Replace speed sensor;
-Replace the controller that is evaluating the signal;
-Check speed sensor incrementer channels;
-Replace speed sensor;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.1515
G
F E XX SOperational
Status
_1172Operation
_1173Operation
DescriptionCause / Triggering EventAction
A speed sensor channel does not pulse
No speed signal from the travel impulse sensor although travel sensor indicates greater than
0.5km/h.
Incrementer damaged The AC-3 Power Control (U8) has identified the sensor bearing as being damaged. The AC-3 Power Control (U8) monitors sensor to ensure the impulse wires are single-channel, and to check for sudden changes in the pulse rate and for constant power supply. Sensor is damaged (broken wire, short circuit, incorrect pulses); Operating system wrongly flags a fault; AC-3 Power Control component (sensor bearing control) is faulty Both sensor tracks are counted. When the first deviation limit is reached the system waits for a feasible signal from the suspected broken track. When the second limit is reached the event is generated.
The counts for both incrementers are compared. Ifthetravel incrementer supplies a speed signal of >0.05km/h and the travel pulse contact controller incrementer a speed signal of 0 km/h, the event is triggered. The activation limit is 100msec.
-Check incrementer signals with multimeter;
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
_1174Operation
_1175Operation
No speed signal from travel sensor although travel impulse sensor indicates greater than 0.5 km/h.
Deviation of more than
0.25km/h between travel impulse sensor and travel sensor
The counts for both incrementers are compared. If the travel incrementer supplies a speed signal of 0 km/h and the travel pulse contact controller incrementer a speed signal of > 0.05 km/h, the event is triggered. The activation limit is 100msec.
The counts for both incrementers are compared. If the speed signals of both incrementers differ by more than
0.025 km/h, the event is triggered. The activation limit is 100msec.
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
õUNGHEINRICH Event Messages
03.1516
G
F E XX SOperational
Status
_1176Operation
_1177Operation
_1178Operation
_1179Operation
_11710Operation
DescriptionCause / Triggering EventAction
Directions obtained from travel sensor and travel impulse sensor are contradictory
One incremental track height measurement of the proportional lift pulses, the other does not
One incremental track height measurement of the free lift pulses, the other does not
One incremental track height measurement of the auxiliary lift pulses, the other does not
Main lift does not lower despite the hydraulic motor turning
The counts for both incrementers are compared. If the speed of both incrementers > 0.01 km/h and the directions of the speed signals for both incrementers are contradictory, the event is triggered. The activation limit is 100msec.
Both sensor tracks are counted. When the first deviation limit is reached the system waits for a feasible signal from the suspected broken track. When the second limit is reached the event is generated.
Both sensor tracks are counted. When the first deviation limit is reached the system waits for a feasible signal from the suspected broken track. When the second limit is reached the event is generated.
Both sensor tracks are counted. When the first deviation limit is reached the system waits for a feasible signal from the suspected broken track. When the second limit is reached the event is generated.
The counts for both incrementers are compared. If the lift controller incrementer supplies a speed signal, but the lift height measurement incrementer does not supply a signal after one second, the event is triggered. The activation limit is 20msec.
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
_11711Operation
Main lift lowers despite the hydraulic motor not turning
The counts for both incrementers are compared. If the lift height measurement incrementer supplies a speed signal, but the lift controller incrementer does not supply a signal after one second, the event is triggered. The activation limit is 20msec.
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
õUNGHEINRICH Event Messages
03.1517
G
F E XX SOperational
Status
_11712Operation
_11713Operation
_11714Operation
_11715Operation
_11716Operation
_11717Operation
DescriptionCause / Triggering EventAction
Excessive deviation between lift speed and pump speed
Proportional lift incrementer 1: One channel defective
Proportional lift incrementer 2: One channel defective
Free lift incrementer 1: Onechannel defective
Free lift incrementer 2: Onechannel defective
Aux. lift incrementer 1: Onechannel defective
The counts for both incrementers are compared. If the incrementers for the lift control and lift height measurement are not synchronised within three seconds, the event is triggered. The activation limit is 100msec.
Channel A or channel B are defective on the incrementer
Channel A or channel B are defective on the incrementer
Channel A or channel B are defective on the incrementer
Channel A or channel B are defective on the incrementer
Channel A or channel B are defective on the incrementer
-Check the hydraulic system for leaks;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
_11718Operation
_11719Operation
_11720Operation
Logic test: Main lift does not lower despite pump rotating
LH load wheel sensor incrementer deviation
RH load wheel sensor incrementer deviation
The counts for both incrementers are compared. If the lift controller incrementer supplies a speed signal, but the lift height measurement incrementer does not supply a signal after one second, the event is triggered. The activation limit is 20 msec.
Incorrect counting detected between ChA and ChB.
Incorrect counting detected between ChA and ChB.
-Check incrementer signals with multimeter;
-Check wiring with multimeter;
-Replace speed sensor;
-Check mounting position of sensor to magnet;
-Replace sensor;
-Check mounting position of sensor to magnet;
-Replace sensor;
õUNGHEINRICH Event Messages
03.1518
G
F E XX SOperational
Status
LH load wheel sensor
_11721Operation
_11722Operation
_11723Operation
_1181Undefined
_1191OperationCabin position implausible
excessive deviation from reading to drive wheel
RH load wheel sensor excessive deviation from reading to drive wheel
Three channel incrementer comparison with sensor bearing incrementer
Speed sensor in load wheel sensor damaged
DescriptionCause / Triggering EventAction
Incorrect counting detected between LH load wheel sensor and drive wheel incrementer.
Incorrect counting detected between RH load wheel sensor and drive wheel incrementer.
The sensor bearing and three channel incrementer are synchronised with respect to each other every 120 mm. The error is generated if the sensor bearing deviates from the three channel sensor by >= 5 mm.
This event message is not currently used.
The event message is triggered if for T >= time limit the following applies:
•A change in status of the platform lower-limit sensor from the neutral position into the "Platform raised" position is detected while driving
-Check mounting position of sensor to magnet;
-Check tyre quality;
-Replace sensor;
-Check mounting position of sensor to magnet;
-Check tyre quality;
-Replace sensor;
-Test the electrical function of the sensor bearing
-Test the mechanical function of the sensor bearing
-Check speed sensor power supply;
-Check wire connection;
-Replace speed sensor;
-Replace signal-evaluating controller;
-Check wiring from controller to platform lower limit sensor;
-Check / replace lower limit sensor;
-Check lift motor power cables;
- Replace the signal-generating controller;
õUNGHEINRICH Event Messages
03.1519
G
F E XX SOperational
Status
_1201OperationDrive wheel slip excessive
_1211Self testOutput stage faulty
_1221
“Digital signal” logic/signal shape implausible
DescriptionCause / Triggering EventAction
Excessive slip / drive has probably been tipped The AC-3 Power Control (U8) has detected excessive deviation (slip) between the phase current frequency and the speed. The activation limit is 20msec. More torque is required from / placed on the motor than it can provide / accept; Field current is reduced excessively; Error accompanying sensor bearing control or output stage protection; Operating system does not allow enough slip for the driven motor; AC-3 Power Control component is damaged
The lift actuator jumper is controlled for max. 40 msec at 100 % PWM (pulse width modulation). The event message is triggered if the pump voltage drops within this time below 10% of the capacitor voltage: V
This event message is triggered if the signal shape or modulation of a digital signal is implausible.
pump
> V
capacitor
/ 10.
-Check motor connection wire (wire breakage);
-Check motor model, replace if necessary;
-Check motor and replace if necessary;
-Check motor connection wire (wire breakage);
-Check motor model, replace if necessary;
-Replace controller;
-Replace tiller head;
_1231Operation
_1232Operation
Brake response switch signal implausible (in idle)
Brake response switch signal implausible (in idle)
The event message is triggered if after the brake applies the feedback switch does not report this status (after 1sec.).
The event message is triggered if after the brake is released the feedback switch does not report this status (after 300msec.).
-Remove physical blockage from the brake;
-Check wire connection;
-Check switch and replace if necessary;
-Replace signal-evaluating controller;
-Remove physical blockage from the brake;
-Check wire connection;
-Check switch and replace if necessary;
-Replace signal-evaluating controller;
õUNGHEINRICH Event Messages
03.1520
G
F E XX SOperational
Status
_1233Operation
_1234Operation
_1235System start
_1236Operation
DescriptionCause / Triggering EventAction
Brake response switch signal implausible (speed > 1km/h)
Brake does not hold on a ramp (failsafe brake)
Failsafe brake does not hold (on system start or motor start)
Left load wheel brake not controlled but feedback signal present
This event message is triggered if the response switch signals applied status during travel.
The event message is triggered if for T > 250 ms the drive system
•reports an actual rotational speed > 20rpm when the brake is applied.
On system start or engine start, the traction drives are subjected to a travel request for a test time. If a truck actual speed is detected, this event will be triggered.
Left load wheel brake not controlled but feedback signal is still present The activation limit is 1000msec.
-Remove physical blockage from the brake;
-Check wire connection;
-Check switch and replace if necessary;
-Replace signal-evaluating controller;
-Check brake wear, replace wear parts / brake if necessary.
-Measure current through the magnetic coil (you should not be able to measure any current when the brake is applied).
-Replace signal-issuing controller;
-Check brake wear, replace wear parts / brake if necessary.
-Measure current through the magnetic coil (you should not be able to measure any current when the brake is applied).
-Replace signal-issuing controller;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1237Operation
_1238Operation
Left load wheel brake controlled although feedback signal missing
Right load wheel brake not controlled but feedback signal present
Left load wheel brake controlled but feedback signal is not present The activation limit is 1000 msec.
Right load wheel brake not controlled but feedback signal is still present The activation limit is 1000 msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.1521
G
F E XX SOperational
Status
Right load wheel brake
_1239Operation
_12310System start
_12311Operation
_1241OperationLift height signal implausible
controlled although feedback signal missing
hydraulic fail-safe brake cannot be released
Parking brake feedback contacts implausible
DescriptionCause / Triggering EventAction
Right load wheel brake controlled but feedback signal is not present. The activation limit is 1000 msec.
for 500 msec.: brake energised and pressure on emergency stop mechanism > 3 bar
If the combinations 0/0 and 1/1 appear for longer than the limit time, a message is activated.
The lift height sensor sequence is implausible. This event message is triggered if the following applies for T=> 500msec: Sequence of 2 lift height signals is implausible, e.g. Toplift height signal without Bottom lift height signal
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Listen to check if emergency stop mechanism switches:
-If so, check the pressure sensor and replace if necessary;
-If not, check the relay and replace if necessary;
-Check brake wear, replace wear parts / brake if necessary;
-Check wire connection;
-Check switch and replace if necessary;
-Replace signal-evaluating controller;
-Check wire connection;
-Check sensor and replace if necessary;
-Replace signal-evaluating controller;
_1242Operation
_1243Operation
“Stacking height redundant inputs” logic implausible
“Free lift sensor redundant inputs” logic implausible
The event message is triggered if for T = 100 ms the following applies:
•NC and NO contacts have the same status The event message is triggered
if for T = 250 ms the following applies:
•NC and NO contacts have the same status When the event occurs, the master assumes that the truck is in the mast lift stage.
-Check wire connection;
-Check sensor and replace if necessary;
-Replace signal-evaluating controller;
-Check wire connection;
-Check sensor and replace if necessary;
õUNGHEINRICH Event Messages
03.1522
G
F E XX SOperational
Status
_1244Operation
_1245Operation
_1246Operation
_1247Operation
DescriptionCause / Triggering EventAction
Lifting stroke greater than 2x free lift, however mast lift has not been detected
“Lift limit switch redundant inputs” logic implausible
“Initial lowering limit redundant inputs” logic implausible
Logic: lift system limit switchfaulty.
Integrated lift stroke is greater than 2x the set free lift height, however sensor indicates free lift. When the event occurs, the master assumes that the truck is in the mast lift stage.
The event message is triggered if for T = 100 ms the following applies:
•NC and NO contacts have the same status The event message is triggered
if for T = 100 ms the following applies:
•NC and NO contacts have the same status
No positive signal at 7B38.1 - 7B38.4 during lifting or lowering.
-Check wire connection;
-Check sensor and replace if necessary;
-Check wire connection;
-Check sensor and replace if necessary;
-Replace signal-evaluating controller;
-Check wire connection;
-Check sensor and replace if necessary;
-Replace signal-evaluating controller;
-If possible, do not use the lift system, as the lift limit is deactivated. The lift mechanism could move too far and be damaged;
-If absolutely necessary, carefully lower the platform manually. Note that lowering must end as soon as the shuttle can move freely underneath the pallets;
-Check limit switches 7B38.1–7B38.4; check signal feedback at inputs R3–R6 of the main controller 8U37;
-Check the wiring;
_1248Operation
_1251Operation
Lift stroke greater than 1.5x free lift, however mast lift has not been detected
Signal on load sensing inputs is implausible
Integrated lift stroke is greater than 1.5x the set free lift height, however sensor indicates free lift. When the event occurs, the master assumes that the truck is in the mast lift stage. Event is reset when mast lift is detected.
During operation combinations 0/0 and 1/1 trigger the event message. The event message can only be reset by resetting the truck. The activation limit is 2000msec.
-Check free-lift sensor (position, contamination);
-Check free-lift height setting (JUDIT);
-Check pump drive (e.g. worn pump?);
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.1523
G
F E XX SOperational
Status
_1252Operation
_1261Operation
_1262Operation
_1263Operation
Description Cause / Triggering Event Action
No load sensing signal when weight > 300 kg
Feedback from a main contactor contact or the emergency stop relay although the Emergency Disconnect switch is not activated.
Feedback from the Emergency Disconnect switch at channel 1 of the Safe computer although the Emergency Disconnect switch has not been activated
Feedback from the main contactor level 1 control at channel 1 of the Safe computer although contactor level 1 has not been activated.
Plausibility test: If the weight display >300kg the load sensors must be applied. The event message can only be reset by resetting the truck. The activation limit is 2000msec.
Feedback from a main contactor contact or the emergency stop relay although the Emergency Disconnect switch is not activated. The event message can only be reset by resetting the truck. The activation limit is 100msec.
Feedback from the Emergency Disconnect switch at channel 1 of the Safe computer although the Emergency Disconnect switch has not been activated. The event message can only be reset by resetting the truck. The activation limit is 100msec.
Feedback from the main contactor level 1 control at channel 1 of the Safe computer although contactor level 1 has not been activated. The event message can only be reset by resetting the truck. The activation limit is 100msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1264Operation
Feedback from the main contactor level 2 control at channel 1 of the Safe computer although contactor level 1 has not been activated.
Feedback from the main contactor level 2 control at channel 1 of the Safe computer although contactor level 1 has not been activated. The event message can only be reset by resetting the truck. The activation limit is 100msec.
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.1524
G
F E XX SOperational
Status
_1265Operation
_1266Operation
_1267Operation
DescriptionCause / Triggering EventAction
Feedback from the Emergency Disconnect switch at channel 2 of the Safe computer although the Emergency Disconnect switch has not been activated
Feedback from the main contactor level 1 control at channel 2 of the Safe computer although contactor level 1 has not been activated.
No feedback from the Emergency Disconnect switch at channel 1/2 of the Safe computer although the Emergency Disconnect switch has been activated
Feedback from the Emergency Disconnect switch at channel 2 of the Safe computer although the Emergency Disconnect switch has not been activated. The event message can only be reset by resetting the truck. The activation limit is 100msec.
Feedback from the main contactor level 1 control at channel 2 of the Safe computer although contactor level 1 has not been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
No feedback from the Emergency Disconnect switch at channel 1/2 of the Safe computer, although activated The event message can only be reset by resetting the truck. The activation limit is 200msec.
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1268Operation
_1269Operation
_12610Operation
No feedback from relay K1 despite Safe computer activation
No feedback from relay K2 despite Safe computer activation
No feedback from relay K3 despite Safe computer activation
No feedback from relay K1 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
No feedback from relay K2 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
No feedback from relay K3 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.1525
G
F E XX SOperational
Status
_12611Operation
_12612Operation
_12613Operation
_12614System start
_12615Operation
DescriptionCause / Triggering EventAction
No feedback from relay K4 despite Safe computer activation
No feedback from main contactor 1 despite "main contactor 1" signal activation
No feedback from main contactor 2 despite "main contactor 2" signal activation
Test routine for emergency stop circuit by the Safe computer has failed
Different input statuses between the two Safe computers
No feedback from relay K4 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
No feedback from main contactor 1 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
No feedback from main contactor 2 although the Safe computer has been activated. The event message can only be reset by resetting the truck. The activation limit is 200msec.
Power up test for emergency stop circuit by the Safe computer has failed The event message can only be reset by resetting the truck. The activation limit is 20msec.
Redundant controllers of the Safe computer have detected different input statuses. The event message can only be reset by resetting the truck. The activation limit is 100msec.
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_12616System start
_12617System start
Comparison of channel A / channel B of external Emergency Disconnect of APM + PLC for diversity
Monitoring of APM+ Emergency Stop cancel request and the power supply.
The error is triggered for the combination 1/0 or 0/1. Activation limit 100 ms.
The Emergency Stop request is withdrawn via the CanBus, however there is no corresponding Emergency Disconnect feedback.
-Check information in the truck display;
-Assess wiring;
-Check CAN-Bus;
-Check information in the truck display;
-Assess wiring;
-Check CAN-Bus;
õUNGHEINRICH Event Messages
03.1526
G
F E XX SOperational
Status
_12618System start
_1271Operation
_1281Operation
_1282Operation
_1291Operation
_1292Operation
_1293Operation
DescriptionCause / Triggering EventAction
Monitoring of APM+ Emergency Stop cancel request and the power supply.
Main Lift lowers without activation signal
Main lift: free lift has lowered before proportional lift
Main lift: proportional lift has lowered before free lift
Main lift: Permissible lowering speed exceeded
Aux. lift: Permissible lowering speed exceeded
Sideshift: Permissible speed exceeded
The Emergency Stop request is set via the CanBus, however there is no corresponding Emergency Disconnect feedback.
Main Lift stage has lost height without request. The event message appears as soon as the lift height lowers by more than 50mm without request.
The free lift stage has moved hydraulically although the proportional lift stage was not fully retracted.
The proportional lift stage has moved hydraulically although the free lift stage was not fully retracted.
The permissible lowering speed has been exceeded.
The permissible lowering speed has been exceeded.
The permissible sideshift speed has been exceeded.
-Check information in the truck display;
-Assess wiring;
-Check CAN-Bus;
-Check mast mechanics;
-Check mast hydraulics;
-Check mast mechanics;
-Check mast hydraulics;
-Check mast mechanics;
-Check mast hydraulics;
-Check mast mechanics;
-Check mast hydraulics;
-Compare actual speed with data sheet values;
-If it is too high, adjust to data sheet value;
-Compare the actual sideshift speed with the data sheet values;
-If the sideshift speed has been exceeded, set it to the data sheet values;
_1294Operation
_1301Operation
Rotate: Permissible speed exceeded
Main lift does not reach pre­tension moment in prescribed time
The permissible rotating speed has been exceeded.
The pre-tension moment could not be established in the set time.
-Compare the actual rotating speed with the data sheet values;
-If the rotating speed has been exceeded, set it to the data sheet values;
-Check the pre-tension torque with JUDIT and adjust if necessary;
-Check mechanical system of the mast;
-Check mast hydraulics;
õUNGHEINRICH Event Messages
03.1527
G
F E XX SOperational
Status
_1302Operation
_1303Operation
_1304Operation
_1311System start
_1312System start
DescriptionCause / Triggering EventAction
Aux. lift does not reach pre­tension moment in prescribed time
Pallet clamp does not reach the "CLOSED" end position in the prescribed time
Pallet clamp does not reach the "OPEN" end position in the prescribed time
Emergency stop circuit power-up test: Emergency Stop switch activated, but CAN-BUS not OK
Emergency stop circuit power-up test: no activation of any pulse contact controllers
The pre-tension moment could not be established in the set time.
The pallet clamp "CLOSED" end position could not be reached in the set time.
The pallet clamp "OPEN" end position could not be reached in the set time.
CAN-BUS status damaged during booting. The event message can only be reset by an Emergency Stop reset. The activation limit is 1000msec.
No pulse contact controller has reported charge circuit activation. The charging of the pulse contact controllers must be finished within 10seconds. The activation limit is 1000msec.
-Check the pre-tension torque with JUDIT and adjust if necessary;
-Check mechanical system of the mast;
-Check mast hydraulics;
-Check the hydraulic setpoint and adjust if necessary;
-Check the pallet clamp mechanisms for sluggishness;
-Check the hydraulic setpoint and adjust if necessary;
-Check the pallet clamp mechanisms for sluggishness;
-Check wiring with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check the charging voltage on the controllers;
-Check wiring;
_1313System start
_1314System start
Emergency stop circuit power-up test: no lift controller activation
Emergency stop circuit power-up test: no traction controller activation
The hydraulic controller has not reported charge circuit activation. The charging of the pulse contact controllers must be finished within 10 seconds. The activation limit is 1000msec.
The traction controller has not reported load circuit activation. The charging of the pulse contact controllers must be finished within 10 seconds. The activation limit is 1000msec.
-Check the charging voltage on the controllers;
-Check wiring;
-Check the charging voltage on the controllers;
-Check wiring;
õUNGHEINRICH Event Messages
03.1528
G
F E XX SOperational
Status
_1315System start
_1316System start
_1317System start
_1321System start
DescriptionCause / Triggering EventAction
Emergency stop circuit power-up test: no steering controller activation
Emergency stop circuit power-up test: no release of main contactor level 2
Emergency stop circuit power-up test: non-defined EMERGENCY STOP error
power circuit activated during charging
The steering controller has not reported load circuit activation. The charging of the pulse contact controllers must be finished within 10 seconds. The activation limit is 1000 msec.
Feedback contact of second main contactor level not closed within 10 seconds. The activation limit is 1000msec.
Other non-separated event message in main contactor circuit. This event message does not occur in normal operation. The activation limit is 1000msec.
Charge
The AC-3 Power Control (U8) has been activated while its internal capacitors were charging. The main contactor was opened during active control. Power circuit activated during charging. The activation limit is 20msec. The main contactor was disconnected during active control; The control system was activated before the main contactor was closed and the internal capacitors were charged; Installation of the AC-3 Power Control component is damaged; AC-3 Power Control component (voltage measurement) is damaged;
-Check the charging voltage on the controllers;
-Check wiring;
-Check the charging voltage on the controllers;
-Check wiring;
The event message should not occur.
Z
Otherwise contact troubleshooting specialists;
-Check power cables (main current connections, integrated charging circuit wiring,...);
-Check main current fuses and replace if necessary;
-Replace AC-3 Power Control interface card;
_1322Self test
Capacitor pre-charge cannot be switched off
The capacitor voltage should reduce by at least 1 V within 750 msec. of the pre-charge circuit being switched off.
-Replace controller;
õUNGHEINRICH Event Messages
03.1529
G
F E XX SOperational
Status
_1323Self test
_1331Operation
_1332Operation
_1333Operation
DescriptionCause / Triggering EventAction
Capacitor pre-charge (output stage pre-charge) not complete
Ground system track 1 left actual value sensor system: invalid channel A / channel B value relationship
Ground system track 2 left actual value sensor system: invalid channel A / channel B value relationship
Ground system track 3 left actual value sensor system: invalid channel A / channel B value relationship
The condition (V-key - V-cap.) < limit voltage is not met within a fixed time after activating the pre-charge circuit.
Switch status of ground sensors unequal. The activation limit is 20msec.
Switch status of ground sensors unequal. The activation limit is 20msec.
Switch status of ground sensors unequal. The activation limit is 20msec.
-Check battery voltage;
-Check key switch voltage;
-Check controller power connections for short circuits;
-Check harness for short circuit;
-Replace component;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace ifnecessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace ifnecessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
_1334Operation
_1335Operation
Ground system track 1 right actual value sensor system: invalid channel A / channel B value relationship
Ground system track 2 right actual value sensor system: invalid channel A / channel B value relationship
Switch status of ground sensors unequal. The activation limit is 20msec.
Switch status of ground sensors unequal. The activation limit is 20msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
õUNGHEINRICH Event Messages
03.1530
G
F E XX SOperational
Status
_1336Operation
_1341Operation
_1343Operation
_1345Operation
_1347Operation
DescriptionCause / Triggering EventAction
Ground system track 3 right actual value sensor system: invalid channel A / channel B value relationship
Brake force governor: invalid channel A / channel B value relationship
Traverse sensor system: invalid channel A / channel B value relationship
Rotate sensor system: invalid channel A / channel B value relationship
Left hand support mushroom: invalid channel A / channel B value relationship
Switch status of ground sensors unequal. The activation limit is 20msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
-Check wiring with multimeter;
-Check sensor system with multimeter;
-Check computer component inputs;
-Repair faulty components and replace if necessary;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
_1349Operation
_13411Operation
_13413Operation
Right hand support mushroom: invalid channel A / channel B value relationship
Steering actual value sensor systems: invalid channel A / channel B value relationship
Steering setpoint device: invalid channel A / channel B value relationship
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
Analog sensor value relationship deviates by more than
2.5°. The activation limit is 100 msec.
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;
-Check sensor wiring;
-Measure sensor signals with multimeter;
-Replace sensor;