JUMO 60.8520 User Manual

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Type 608520/2380
Type 608550/1080
Contact dial thermometer
Particularities
• Temperature controller with actual value display as panel-mounting or add-on device
• Stainless steel case with bayonet lock
•Class 1.5
• Protection class IP 53
• Case sizes : 60 mm, 80 mm and 100 mm Front frame: 72x72 mm and 96x96 mm
Brief description
Contact dial thermometer are devices with actual value display for temperature measurement, control and monitoring and can be used universally.
Data sheet 608520
Page 1/12
The temperature depending volume change in a measuring system filled with liquid or the tem­perature depending pressure change in a measuring system filled with gas is converted to a ro­tational movement of the actual value indicator by a bourdon tube, no transmission gear is required. The microswitch is actuated by the rotational movement of the indicator shaft via a tap system.
Technical Data
Case and front frame Stainless steel (1.4301)
Cover cap Plastic (PA6), gray, UV stabilized
Protection type IP 51 as per DIN EN 60529 (IP 53 with extra code 401)
Front pane Acryl glass (PMMA)
Chassis Aluminum (3.2582.05)
Scale white, labeled in black
Display Class 1.5 similar to DIN EN 13190
Anti-kink spring for devices with capillary on the case and the temperature probe
Set point value setting by set point controller in the front window
Display correction on the rear
Limit value temperatures for transport and storage -30°C...+70°C
Rated position any
(for display range -40...+40°C up to max. 50°C; -30...+50°C up to max. 60°C)
2011-04-14 / 00304658
Data sheet 608520 Page 2/12
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Technical Data
Display range (AB) Display range in °C Measuring range in °C Tolerance in °C
469 -40...+40 -30...+30 1.5
643 -20...+120 -20...+120 3.0
807 0...+60 +10...+50 1.5
814 0...+100 +10...+90 1.5
818 0...+120 +20...+100 3.0
832 0...+200 +20...+180 3.0
840 0...+300 +30...+270 6.0
848 0...+400 +50...+350 6.0
854 0...+500 +50...+450 8.0
848 0...+600 +100...+500 10.0
Liquid filling Gas filling
Measuring system Display range (AB) 350°C Display range (AB) ÷ 400°C
Time behavior approx. 12 s, measured in water,
with a probe Ø of 6 mm made of Cu.
Ambient temperature influence effect
In % of the display range (referring to the deviation from the reference value +23°C)
on case 0.15% of the display range
per K ambient temperature change
on capillary (per m) 0.03% of the display range
per K ambient temperature change
Higher ambient temperature – higher temperature display – lower switching point
Anti-kink spring for devices with capillary on the case and the tem-
perature probe
Set point value setting by set point controller in the front window
Display correction on the rear
Limit value temperatures for transport and storage -30°C...+70°C
(for display range -40...+40°C up to max. 50°C; -
30...+50°C up to max. 60°C)
Rated position any
with a probe Ø of 10 mm made of stainless steel.
approx. 4 s, measured in oil,
0.05% of the display range
per K ambient temperature change
no influence
standard Extra code (TZ) 650
Electric contact
Type of contact
Single-pole microswitch with mechanically actuate change-over contact
Contact rating AC 230V, +10/-15%, 48...63Hz, cos ϕ = 1 (0.6)
5 (1.5) A 10 (3) A
Hysteresis approx. 1.5% of the display range 1.5 to 3% of the display range
Switching point accuracy ± 0.5% of the display range referring to the switch-off point with rising temperature
Switching reliability To ensure a high switching reliability, we recommend a minimum voltage of
24 V and a minimum current of 100 mA
standard Design 02 and 22 Design 10, 23 and TZ 426 Case
Electrical connection Screw-type termi-
nals, connection
2011-04-14 / 00304658
cross section up to
2
2.5 mm
Connection cable 0.5 m
with screw-type terminals
Cover cap with cable
screw-connection, suitable
for cable Ø from 6.5 to
13 mm
60 mm
Cover cap with cable
screw-connection,
suitable for cable Ø
from 8 to 10 mm
Data sheet 608520 Page 3/12
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Note:
Physical and toxic features of the expansion means, which could emerge in the event of a measuring system break.
Control range with scale limit value
< +200°C
Hazardous
reactions
no
Fire and explosion hazard hazardous to
Ignition tem-
perature
Explosion lim-
it
waters
+ 355°C 0.6 - 8 V% yes yes
Information about toxicology
irritant dangerous to
health
a
a
toxic
no≥ 200°C ≤ +350 °C + 490°C - - yes yes
> 350°C +500°C no no no no no
a
There is currently no statement by the health authority concerning hazards to health in the event of short-term exposure and low concentration, e.g. measuring system break.
2011-04-14 / 00304658
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Dimensions
S
L
42
80 Ø
85 Ø
8,5
62,5 29
( 1 )
29
42
106 Ø
100 Ø
8,5
62,5
( 1 )
S
L
29
17,5
Ø
85
Ø
80
8,5
62,5
40S
L
36
44,5
( 2 )
Type:
608520/0280
Type:
608520/0210
Data sheet 608520 Page 4/12
( 1 ) Connection line 0.6 m long with screw terminal
( 1 ) Connection line 0.6 m long with screw terminal
Type:
608520/1080
( 2 ) active probe dimension
2011-04-14 / 00304658