Ivoclar Vivadent VP3 User Manual

Operating Instructions
VP3 Vacuum Pump
3
List of Parts 4
1. Introduction / Signs and Symbols 5
1.1 Preface
1.2 Introduction
2. Safety First 6
2.1 Indications
2.2 Health and safety instructions
3. Product Description 8
3.1 Components
3.2 Functional description
3.3 Hazardous areas and safety equipment
4. Installation 9
4.1 Unpacking and checking the contents
4.2 Selecting the location
4.3 Making the connections
4.4 Mounting the sound absorber
5. Start-Up 9
6. Operation 9
7. Maintenance, Cleaning, and Diagnosis 10
7.1 Monitoring and Maintenance
7.2 Cleaning
7.3 Notes on maintenance
8. What If... 11
8.1 Technical malfunctions
8.2 Repairs
9. Product Specifications 12
9.1 Delivery from
9.2 Technical data
9.3 Acceptable operating conditions
9.4 Acceptable transportation conditions
Operating Instructions
4
3
10
4
1
9
15
15
4
5
1
6
8
14
12
13
11
7
List of Parts:
1 Rubber feet 2 Pump power plug 3 Power cord 4 Sound absorber 5 Protective cap 6 Rating plate 7 Vacuum hose connection 8 Air vents 9 Housing 10 Connection tube 11 Connection cover 12 Fuse holder 13 Fuse 14 Condenser 15 Sound absorber connection
1.1 Preface
Dear Customer
Thank you for having purchased the Programat
®
Vacuum Pump. This apparatus is a high-quality, tech­nical product. Please read the Operating Instructions carefully and use the apparatus according to the Instructions. Should your have any further questions, please do not hesitate to contact your local distributor or Ivoclar Vivadent AG directly.
1.2 Introduction
Apparatus: VP3 Vacuum Pump Target group:
Dental lab personnel
This vacuum pump is suitable for evacuating the firing chamber of the Programat ceramic furnace and the IPS Empress
®
press furnace. It is a quietly-running double-diaphragm pump with high vacuum performance.
These Operating Instructions are designed to assure the correct, safe, and economic use of the VP3 Vacuum Pump. They are divided into several, clearly structured chapters to help you find specific topics quickly and easily.
Signs and symbols (pictographs) are used to inform you quickly and clearly about health risks, important details, and contraindications.
We recommend keeping the Instructions in a safe place near the pump so that they are immediately accessisble if necessary. Should you lose the Operating Instructions, extra copies can be ordered at a nominal fee from your local Ivoclar Vivadent Service Center.
1.3 Signs and symbols
The signs and symbols in these Operating Instructions and on the pump facilitate the finding of important points and have the following meanings:
Operating Instructions:
Risks and dangers
Information
Contraindication
Pump:
Alternating current
5
1. Introduction
Loading...