![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg1.png)
Refer to Installation manual for full instructions.
On-Premise
Laundry
Planning
Handbook
120 and 170 Pound Tumblers
4-08-45R4
June 2011
Through Serial No. 0907000048
![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg2.png)
Table of
Contents
Tumblers – 120 and 170 ..................................................................... 2
Introduction...................................................................................... 2
Model Identification .................................................................. 2
Specifications and Dimensions ........................................................ 4
120 Pound Tumbler Dimensions and
Exhaust Outlet Locations ......................................................... 5
170 Pound Tumbler Dimensions and
Exhaust Outlet Locations ......................................................... 6
Electric and Gas Connection Locations for
Gas Models............................................................................... 7
Electric and Steam Connection Locations for
Steam Models........................................................................... 8
Installation........................................................................................ 9
Pre-Installation Inspection ......................................................... 9
Tumbler Enclosure..................................................................... 10
Exhaust Requirements ..................................................................... 11
Layout ........................................................................................ 11
Make-Up Air.............................................................................. 11
Venting ...................................................................................... 11
Individual Venting..................................................................... 12
Manifold Venting....................................................................... 14
Electrical Requirements ................................................................... 17
© Published by permission of the copyright owner.
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
4-08-45
![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg3.png)
Introduction
Tumblers – 120 and 170
Model Identification
Gas Steam/Thermal Oil
120 Pound
170 Pound
Includes models with the following control suffixes:
RD – reversing DMP OPL RQ – reversing dual digital timer
IPD120G2-IT120L IPD120G2-IT120N IPD120S2-IT120S IPD120S2-IT120T
IPD170G2-IT170L IPD170G2-IT170N IPD170S2-IT170S IPD170S2-IT170T
TMB1268C
4-08-45
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2
![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg4.png)
Tumblers – 120 and 170
120 POUND TUMBLER
1
1
170 POUND TUMBLER
1 Serial Plate
TMB1298N
Conversion Table
Multiply By To Obtain Multiply By To Obtain
Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars
Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm
Inch 25.4 Millimeters Pounds (lbs.) 0.454 Kilograms
Inches W.C. 0.036 Pounds/sq. inch Boiler Horsepower 33,479 Btu/hr.
Inches W.C. 0.249 kPa Boiler Horsepower 34.5 lbs. steam/hr.
lb./inch
ft.
2
(psi) 6.895 kPa CFM 0.471 liters/second
3
28.32 Liters kW 3414 Btu/hr.
3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
4-08-45
![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg5.png)
Specifications and Dimensions
Specifications 120 Pound 170 Pound
Noise level measured during operation
at operator position of 3.3 feet (1 meter)
in front of machine and 5.2 feet
(1.6 meters) from floor.
Tumblers – 120 and 170
66 dBA 66 dBA
Cylinder Size:
Inches (mm)
Cylinder Capacity dry weight:
Pounds (kg)
Cylinder Motor Horsepower
Fan Motor Horsepower
Air Outlet Diameter:
Inches (mm)
Maximum Static Back Pressure:
W.C.I. (mbar)
Maximum Airflow:
C.F.M (L/sec.)
Net Weight (approximate):
Pounds (kg)
Gas Connection
Gas Burner Rating:
Btu/hr. (Mj/hr.)
(1118 x 1041)
Gas Models
3/4 in. NPT 1 in. NPT
44 x 41
120
(54.4)
0.75 0.75
13
10
(254)
0.3
(0.8)
1600
(755)
1275
(580)
300,000
(316)
50.75 x 42.5
(1289 x 1080)
170
(77.1)
12
(300)
0.3
(0.8)
2450
(1156)
1575
(716)
395,000
(421)
Net Weight (approximate):
Pounds (kg)
Steam Connection
Steam Coil Rating at 100 psig:
Boiler Horsepower (Btu/hr.)
(recommended operating pressure
80-100 psig)
N/A = Not Applicable
Steam Models
(625)
3/4 in. NPT inlet
3/4 in. NPT outlet
(405,000)
1375
11.7
1675
(761)
3/4 in. NPT inlet
1 in. NPT outlet
18.8
(648,000)
4-08-45
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
4
![](/html/f8/f81e/f81e803e7c377c3fda371c7147bfcaccb3751797c8133c7f6f84e420d95166ab/bg6.png)
Tumblers – 120 and 170
A
B
C
D
U
V
X
H
F
Z
Y
I
W
TOP VIEW OF
EXHAUST
DUCT
E
G
120 Pound Tumbler Dimensions and
Exhaust Outlet Locations
Cabinet Dimensions
ModelsABCDEFGH I
120L/N
120S
31.38 in.
(797 mm)
31.38 in.
(797 mm)
32.5 in.
(826 mm)
32.5 in.
(826 mm)
48.91 in.
(1242 mm)
48.91 in.
(1242 mm)
49.91 in.
(1268 mm)
49.91 in.
(1268 mm)
67.92 in.
(1725 mm)
67.92 in.
(1725 mm)
45.38 in.
(1153 mm)
45.38 in.
(1153 mm)
46.38 in.
(1178 mm)
46.38 in.
(1178 mm)
85.7 in.
(2177 mm)
83.5 in.
(2121 mm)
(1778 mm)
(1778 mm)
Refer to Position and Level the Tumbler to temporarily reduce the heights of these models.
Exhaust Outlet Dimensions and Locations
Models U V W X Y Z
120L/N
120S
63.45 in.
(1612 mm)
60.7 in.
(1542 mm)
8.44 in.
(214 mm)
8.44 in.
(214 mm)
5 in.
(127 mm)
5 in.
(127 mm)
8.18 in.
(208 mm)
8.18 in.
(208 mm)
6.82 in.
(173 mm)
6.82 in.
(173 mm)
8.18 in.
(208 mm)
8.18 in.
(208 mm)
TMB2333N
70 in.
70 in.
5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
4-08-45