Infinity PS-10, PS-12 Service manual

PS-10
PS-12
PS Series Powered Subwoofers
SERVICE MANUAL
250 Crossways Park Dr.
Woodbury, New York 11797 Rev1 10/2004
PS-10/PS-12
BASIC SPECIFICATIONS . . . . . . . . . …………………………….... .. . . . . . 1
PS-10 DETAILED SPECIFICATIONS . . . . . . . . . . . . . . ..…. . .. .. .. . . . . . 2
PS-12 DETAILED SPECIFICATIONS . . . . . . . . . . . . . . .….. . .. .. .. . . . . . 4
CONTROLS & CONNECTIONS . . . . . . . . . . . …………………………. . . . 6
OPERATION……. . . . . .. . . . . . . . .. .. . . . .. .. . . . . ………… . . ... . . . . . . . 8
PS-10 BLOCK DIAGRAM……………... ………………… . … . .. .. . . .. . … . 9
PS-12 BLOCK DIAGRAM……………... ………………… . …. .. .. . . .. . … . 10
PS-10/12 TEST SET-UP AND PROCEDURE……………………………….…11
TECH TIP INFTT2003-02……………... ………………… . …. .. .. . . .. . … . 12
PS-10 EXPLODED VIEW . . . . . . . . …………………………….... .. .. . . . . 13
PS-12 EXPLODED VIEW . . . . . . . . …………………………….... .. .. . . . . 14
PS-10 PACKING…. . . . . .. . . . . . . . .. .. . . . .. .. . . . ………..………………15
CONTENTS
PS-12 PACKING…. . . . . .. . . . . . . . .. .. . . . .. .. . . . ….……….……………16
PS-10 ELECTRICAL PARTS LIST …………. .... . . . . .. …………….... . . . . 17
PS-12 ELECTRICAL PARTS LIST …………. .... . . ……………….. .. .. . . . . 21
PCB DRAWINGS. .. . . . . . . . . . . . . . .. . . . . ………………………….. . . . . . 25
IC – TRANSISTOR PINOUTS . … . . .. . . . . . …………………..…..…... . . . 28
PS-10 SCHEMATIC DIAGRAMS . . . . . . . . .. .. .. .. . . .….………...……. . . .29
PS-12 SCHEMATIC DIAGRAMS . . . . . . . . .. .. .. .. . . .………..…..……. . . .31
SPECIFICATIONS PS-10 PS-12
Frequency Response: 27Hz – 150Hz (±3dB) 25Hz – 150Hz (±3dB) Maximum Amplifier Output: 250 watts RMS 300 watts RMS
(20Hz – 150Hz with no more than 0.1% THD)
Crossover Frequencies: 50Hz – 150Hz, 50Hz – 150Hz
24dB/octave, continuously variable
Driver: 10" (254mm) MMD 12" (305mm) MMD Dimensions (H x W x D): 14 3/4" x 12-1/2" x 16" 16-1/2" x 14-3/8" x 17-1/2"
(375mm x 318mm x 406mm) (419mm x 365mm x 445mm)
Weight: 38 lb (17.3kg) 45 lb (20.5kg)
Infinity continually strives to update and improve existing products, as well as create new ones. The specifications and construction details in this and related Infinity publications are therefore subject to change without notice.
1
A
(
PS-10/PS-12
2
PS-10 Powered Sub/ Plate Amp
LINE VOLTAGE Yes/No Hi/Lo Line Nom. Unit Notes
US 120vac/60Hz Yes 108-132 120 Vrms Normal Operation EU 230vac/50-60Hz Yes 207-264 230 Vrms Normal operation, MOMS required
Parameter Specification Unit Amp Section
Type (Class AB, D, other) D n/a n/a Load Impedance (speaker) 5.6 Ohms n/a Nominal Rated Output Power (120VAC) 150 Watts 138 Domestic version only 120 VAC-60 Hz Rated Output Power (230VAC) 150 Watts 128 EU Version only 230 VAC-50 Hz
AVG RMS Dynamic Power 250 Watts 225
THD @ Rated Power 0.5 % 1 22K filter 145 Watts THD @ 1 Watt 0.1 % 0.5 22K filter DC Offset 10 mV-DC 30 Amplifier output
Damping factor >50 DF 20 Measured at amplifier board
Input Sensitivity
Input Frequency 35 Hz 35 Nominal Freq. L&R 300 mVrms ±2dB To 150 Watts, Ap Zo=600 Ohms Single input driven L or R input 300 mVrms ±2dB To 150 Watts , Ap Zo=600 Ohms Single input driven, LFE switch ON Speaker/Hi Level Input 2.6 Vrms ±2dB To 150 Watts Single input driven
Signal to Noise
SNR-A-Weighted 90 dBA 85 relative to rated power A-Weighting filter SNR-unweighted 85 dBr 75 relative to rated power 22K filter SNR rel. 1W-unweighted 65 dBr 60 relative to 1W Output 22K filter
Residual Noise Floor 1 mVrms 1.5
Residual Noise Floor 1.5 mVrms
Input Impedance
Line Input (L, R,LFE) 10K ohms n/a Nominal Speaker/Hi Level Input > 4.7K ohms n/a Nominal
QA Test
Limits
max)1.5
Volume @max, using RMS reading DMM/VOM (or A/P) BW=20 Khz.
Volume @max, w/ A/P Swept Bandpass Measurement (Line freq.+ harmonics) (BW=20 Khz)
Conditions Notes
verage RMS power, 3/20 Cycles 50 Hz, Driven
6dB above its input sensitivity sensitivity
Measured at the amplifier board. 150 Watts @ 50 Hz, THD must be less tan 0.1%
Line level inputs must be terminated using 1KOHM
Line level inputs must be terminated using 1KOHM
Filters
LP filter 4th order fixed 50-150 Hz ± 10 2nd Order variable and 2nd order fix 2nd order variable + 2nd order fix-24 db/Octave HP Filter 2nd order Fixed F=32 Hz, Q=0.95
LFE Low pass 2nd order 200>LP<1K Hz LFE input driven only Notch filter (Friend circuit) F=61.6 Hz, Q=4, Av=-3.5dB HP speaker out connector Left & Right 200 Hz ± 10 Speaker input driven - 4 Ohms (Applies to 230VAC model only) Left & Right 100 Hz ± 10 Speaker input driven - 8 Ohms (Applies to 230VAC model only)
Limiter
THD at Max. Output Power n/a n/a functional Maximum Output Power Maximum THD as a result of limiting.
Features
Volume pot Taper (lin/log) LOG -- functional A Taper Speaker input connectors YES functional L&R Speaker input binding post connectors
HP Speaker out YES functional Phase switch 0-180 deg functional
LP Filter defeat switch YES functional Disables LP filter, intended for LFE
Input Configuration
Line In (L,R) & LFE YES -- functional Dual RCA jack Spkr/Hi Level In YES -- functional Binding post connector L&R
Signal Sensing (ATO)
Auto-Turn-On (yes/no) YES functional ATO Input test frequency 50 Hz functional " ATO Level LFE Input 2 mV functional " Maximum acceptable level. ATO Level Speaker in 40 mV functional " Maximum acceptable level.
ATO Turn-on time 5 ms functional
Auto Mute/ Turn-OFF Time 15 minutes 18
--
L&R Speaker out with HP applies only to 230VAC models
Amp connected and AC on, then input signal applied T before muting, after line or speaker level signal is removed
Auto turn of time (T) must be 5 > T < 18 Minutes
Power on Delay time
Transients/Pops
ATO Transient 5 mV-peak n/a @ Speaker Outputs
3 sec. 4 AC Power Applied
PS-10/PS-12
3
Turn-on Transient 50 mV-peak 2V-pk-pk @ Speaker Outputs AC Line cycled from OFF to ON Turn-off Transient 50 mV-peak 2V-pk-pk @ Speaker Outputs AC Line cycled from ON to OFF
Efficiency
Efficiency 65 % 65 Nominal Line voltage 120 VAC
Stand-by Input Power 18 Watts 20 @ nom. line voltage
Power Cons. @ rated power 230 Watts 240 @ nom. line voltage 150 Watts into 5.6 Ohms @ nominal line voltage
Maximum allowable input power under nominal Input voltage and frequency, HOT or COLD operation.
Protections
Short Circuit Protection YES functional Direct short at output
Thermal Protection YES functional
DC Offset Protection YES - DC present at Speaker Out leads
Line Fuse Rating USA-Domestic 2 Amps 2 Type-T or Slo Blo-250 V Internal fuse with UL/SEMKO rated holder
EU (230v) 1.25 Amps 1.25
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE.
5.- EURPOEAN VERSION MUST BE PROVIDED WITH PLASTIC PLUGS ON THE BINDING POST CONNECTORS
@1/8 max unclipped Power at 1.06 times the input voltage
Type-T or Slo Blo-250 V, Low Breaking capacity
Amplifier should resume operation after short circuit condition removal Temperature rise in accessible metal parts should not exceed 35K rise for domestic version or 30K rise for European versions (refer to requirements sheet). Design must insure no Offset at the speaker output under any operating condition including abnormal operation
Internal fuse with UL/SEMKO rated holder
PS-10/PS-12
4
PS-12 Powered Sub/ Plate Amp
LINE VOLTAGE Yes/No Hi/Lo Line Nom. Unit Notes
US 120vac/60Hz Yes 108-132 120 Vrms Normal Operation EU 230vac/50-60Hz Yes 207-264 230 Vrms Normal operation, MOMS required
Parameter Specification Unit
Amp Section
Type (Class AB, D, other) D n/a n/a Load Impedance (speaker) 5.6 Ohms n/a Nominal Rated Output Power (120VAC) 150 Watts 138 Domestic version only 120 VAC-60 Hz Rated Output Power (230VAC) 150 Watts 128 EU Version only 230 VAC-50 Hz
AVG RMS Dynamic Power 250 Watts 225
THD @ Rated Power 0.5 % 1 22K filter 140 Watts THD @ 1 Watt 0.1 % 0.5 22K filter DC Offset 10 mV-DC 30 Amplifier output
Damping factor >50 DF 20 Measured at amplifier board
Input Sensitivity
Input Frequency 35 Hz 35 Nominal Freq. L&R 250 mVrms ±2dB To 150 Watts, Ap Zo=600 Ohms Single input driven L or R input 250 mVrms ±2dB To 150 Watts , Ap Zo=600 Ohms Single input driven, LFE switch ON Speaker/Hi Level Input 2.3 Vrms ±2dB To 150 Watts Single input driven
Signal to Noise
SNR-A-Weighted 90 dBA 85 relative to rated power A-Weighting filter SNR-unweighted 85 dBr 75 relative to rated power 22K filter SNR rel. 1W-unweighted 65 dBr 60 relative to 1W Output 22K filter
Residual Noise Floor 1 mVrms 1.5
Residual Noise Floor 1.5 mVrms(max) 1.5
QA Test
Limits
Conditions Notes
Volume @max, using RMS reading DMM/VOM (or A/P) BW=20 Khz.
Volume @max, w/ A/P Swept Bandpass Measurement (Line freq.+ harmonics) (BW=20 Khz)
Average RMS power, 3/20 Cycles 50 Hz, Driven 6dB above its input sensitivity sensitivity
Measured at the amplifier board. 140 Watts @ 50 Hz, THD must be less than 0.1%
Line level inputs must be terminated using 1KOHM
Line level inputs must be terminated using 1KOHM
Input Impedance
Line Input (L, R,LFE) 10K ohms n/a Nominal Speaker/Hi Level Input > 4.7K ohms n/a Nominal
Filters
LP filter 4th order fixed 50-150 Hz ± 10 2nd Order variable and 2nd order fix 2nd order variable + 2nd order fix-24 db/Octave HP Filter 2nd order Fixed F=29 Hz, Q=1.5
LFE Low pass 2nd order 200>LP<1K Hz LFE input driven only Notch filter (Friend circuit) 54 Hz, Q=1.738, Av=-5.0dB HP speaker out connector Left & Right 200 Hz ± 10 Speaker input driven - 4 Ohms (Applies to 230VAC model only) Left & Right 100 Hz ± 10 Speaker input driven - 8 Ohms (Applies to 230VAC model only)
Limiter
THD at Max. Output Power n/a n/a functional Maximum Output Power Maximum THD as a result of limiting.
Features
Volume pot Taper (lin/log) LOG -- functional A Taper Speaker input connectors YES functional L & R Binding post connector
HP Speaker out YES functional Phase switch 0-180 deg functional
LP Filter defeat switch YES functional Disables LP filter, intended for LFE
Input Configuration
Line In (L,R) & LFE YES -- functional Dual RCA jack Spkr/Hi Level In YES -- functional Binding post connector L&R
Signal Sensing (ATO)
Auto-Turn-On (yes/no) YES functional ATO Input test frequency 50 Hz functional " ATO Level LFE Input 2 mV functional " Maximum acceptable level. ATO Level Speaker in 40 mV functional " Maximum acceptable level.
ATO Turn-on time 5 ms functional
Auto Mute/ Turn-OFF Time 15 minutes 18
--
L & R Binding post connectors and High pass filter (Applies only to 230V model)
Amp connected and AC on, then input signal applied T before muting, after line or speaker level signal is removed
Auto turn of time (T) must be 5 > T < 18 Minutes
Power on Delay time
3 sec. 4 AC Power Applied
PS-10/PS-12
5
Parameter Specification Unit
Transients/Pops
ATO Transient 5 mV-peak n/a @ Speaker Outputs Turn-on Transient 50 mV-peak 2V-pk-pk @ Speaker Outputs AC Line cycled from OFF to ON Turn-off Transient 50 mV-peak 2V-pk-pk @ Speaker Outputs AC Line cycled from ON to OFF
Efficiency
Efficiency 65 % 65 Nominal Line voltage 120 VAC
Stand-by Input Power 18 Watts 20 @ nom. line voltage
Power Cons. @ rated power 230 Watts 240 @ nom. line voltage 150 Watts into 5.6 Ohms @ nominal line voltage
QA Test
Limits
Conditions Notes
Maximum allowable input power under nominal Input voltage and frequency, HOT or COLD operation.
Protections
Short Circuit Protection YES functional Direct short at output
Thermal Protection YES functional
DC Offset Protection YES - DC present at Speaker Out leads
Line Fuse Rating USA-Domestic 2 Amps 2 Type-T or Slo Blo-250 V Internal fuse with UL/SEMKO rated holder
EU (230v) 1.25 Amps 1.25
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE.
5.- EURPOEAN VERSION MUST BE PROVIDED WITH PLASTIC PLUGS ON THE BINDING POST CONNECTORS
@1/8 max unclipped Power at 1.06 times the input voltage
Type-T or Slo Blo-250 V, Low Breaking capacity
Amplifier should resume operation after short circuit condition removal Temperature rise in accessible metal parts should not exceed 35K rise for domestic version or 30K rise for European versions (refer to requirements sheet). Design must insure no Offset at the speaker output under any operating condition including abnormal operation
Internal fuse with UL/SEMKO rated holder
PS-10/PS-12
Rear Panel
CONTROLS AND CONNECTIONS
¡
Subwoofer-Level Control
LFE/Normal Selector
£
Phase Switch
¢
Crossover Adjustment
Line-Level/LFE Input
§
Speaker-Level Inputs
Power Switch
Status LED
PS-10/PS-12
6
Green: On
Red: Stand-By
CROSSOVER FREQUENCY
LINE LEVEL IN
§
¡
LEVEL
+ –
Min
LFE NORMAL
PHASE
80Hz
50Hz
L R
For LFE use L or R
L
HIGH
LEVEL
IN
R
Max
180º
150Hz
£
¢
ON
POWER
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRICAL 
SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
AVERTISSEMENT: POUR PRÉVENIR LES RISQUES D'INCENDIE OU DE CHOC 
ÉLECTRIQUE, ÉVITER D'EXPOSER CET APPAREIL A LA PLUIE OU A L'HUMIDITÉ.
OFF
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
120V
60Hz
NRTL/C CSA 22.2 UL1492
PS-10/PS-12
SYSTEM CONNECTIONS
If your receiver/processor does not contain a Dolby Digital or
DTS processor but has subwoofer outputs:
Set line-level/LFE switch to “Normal.”
NOTE: If your receiver/processor
has only one sub out,you may use either the L or R input.
If you have a Dolby* Digital or DTS
®
receiver/processor with a low-frequency-effects (LFE) or subwoofer output:
CROSSOVER FREQUENCY
LEVEL
LINE LEVEL IN
PHASE
Min
Max
L
R
L R
For LFE use L or R
LFE NORMAL
HIGH
LEVEL
IN
50Hz
180º
150Hz
RECEIVER/AMPLIFIER
Front Speaker Output
80Hz
Green: On
Red: Stand-By
+ –
CROSSOVER FREQUENCY
LEVEL
LINE LEVEL IN
PHASE
Min
Max
L
R
L R
For LFE use L or R
LFE NORMAL
HIGH
LEVEL
IN
+ –
50Hz
180º
150Hz
RECEIVER/PROCESSOR
80Hz
L R
Green: On
Red: Stand-By
CROSSOVER FREQUENCY
LEVEL
LINE LEVEL IN
PHASE
Min
Max
L R
For LFE use L or R
LFE NORMAL
50Hz
180º
150Hz
SUBWOOFER OR LFE OUTPUT
80Hz
Green: On
Red: Stand-By
Set LFE/Normal switch to “LFE.”
This figure shows how to connect bare wires to the terminals.
If your receiver/processor does not have subwoofer outputs for the left and right channels or an LFE output,connect speaker wire from your receiver/amplifier to your speakers and subwoofer using two sets of speaker wire:
PS-10/PS-12
7
RED =
+
–
BLACK =
1.
LOOSEN TERMINALS
2.
INSERT BARE END;  TIGHTEN TERMINALS
NO STRIPE = –STRIPE =
+
PS-10/PS-12
OPERATION
Power On
Plug your subwoofer’sAC cord into a wall outlet.Do not use the outlets on the back of the receiver.
Initially set the Subwoofer-Level Control
¡
to the “min”position.
Turn on your sub by pressing the Power Switch
on the rear panel.
Turn on your entire audio system and start a CD or movie soundtrack at a moderate level.
Auto On/Stand-By
With the Power Switch ¶in the ON position,the Status LED •on the back panel will remain lit in red or green to indicate the On/Standby mode of the subwoofer.
RED = STANDBY (No signal detected,Amp Off) GREEN = ON (Signal detected,Amp On) The subwoofer will automatically enter the Standby mode after approxi-
mately 10 minutes when no signal is detected from your system.The sub­woofer will then power ON instantly when a signal is detected.During periods of normal use,the Power Switch
can be left on.You may turn
off the Power Switch
for extended periods of nonoperation,e.g.,when
you are away on vacation.
Adjust Gain
Turn your Subwoofer-Level Control ¡up to the halfway position.If no sound emanates from the subwoofer,check the AC-line cord and input cables.Are the connectorson the cables making proper contact? Is the AC plug connected to a “live”receptacle? Has the Power Switch
been pressed to the “On”position? Once you have confirmed that the subwoofer is active,proceed by playing a CD,record or cassette. Use a selection that has ample bass information.
Set the overall volume control of the preamplifier or stereo to a comfort­able level.Adjust the Subwoofer-Level Control
¡
until you obtain a pleas­ing blend of bass.Bass response should not overpower the room but rather be adjusted so there is a harmonious blend across the entire musi­cal range.Many users have a tendency to set the subwoofer volume too loud,adhering to the belief that a subwoofer is there to produce lots of bass.This is not entirely true.A subwoofer is there to enhance bass, extending the response of the entire system so the bass can be felt as well as heard.However, overall balance must be maintained or the music will not sound natural.An experienced listener will set the volume of the subwoofer so its impact on bass response is always there but never obtrusive.
Phase Control
The Phase Switch £determines whether the subwoofer speaker’s piston­like action moves in and out with the main speakers,0˚,or opposite the main speakers,180˚.P roper phase adjustment depends on several variables such as room size,subwoofer placement and listener position. Adjust the phase switch to maximize bass output at the listening position.
Crossover Adjustment
The Crossover Adjustment Control ¢ determines the highest frequency at which the subwoofer reproduces sounds.If your main speakers can comfort­ably reproducesome low-frequency sounds,set this control to a lower frequency setting,between 50Hz and 100Hz.This will concentrate the subwoofer’s efforts on the ultradeep bass sounds required by today’s films and music.If you are using smaller bookshelf speakers that do not extend to the lower bass frequencies,set the Crossov er Adjustment control to a higher setting, between 120Hz and 150Hz.
NOTE:This control will have no effect if the LFE/Normal Selector
is set
to LFE.If you have a Dolby Digital or DTS processor/receiver, the Low-Pass Frequency is set by the processor/receiver. Consult your owner’s manual to learn how to view or change this setting.
MAINTENANCE AND S
ERVICE
The enclosure may be cleaned using a soft cloth to remove fingerprints or to wipe off dust.
The grille may be gently vacuumed.Stains may be removed with an aerosol cleaner, following its instructions.Do not use any solvents on the grille.
All wiring connections should be inspected and cleaned or remade peri­odically.The frequency of maintenance depends on the metals involved in the connections,atmospheric conditions,and other factors,but once per year is the minimum.
If a problem occurs,make sure that all connections are properly made and clean.If a problem exists in one loudspeaker,reverse the connection wires to the left and right system.If the problem remains in the same speaker,then the fault is with the loudspeaker.If the problem appears in the opposite speaker,the cause is in another component or cable. In the event that your subwoofer ever needs service,contact your local Infinity dealer or Infinity directly at 1.516.674.4INF or www.infinitysystems.com for a service center near you.
PS-10/PS-12
8
PS-10 BLOCK DIAGRAM
9
PS-10/PS-12
Loading...
+ 23 hidden pages