The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang Shenzhen 518129 People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
AP7050DE Hardware Installation and Maintenance Guide
Intended Audience
This document describes hardware features of the AP7050DE and provides basic installation methods.
This document is intended for:
l Network planning engineers

About This Document

About This Document
l Hardware installation engineers
l Commissioning engineers
l Onsite maintenance engineers
l System maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to personal injury.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii
NOTE
AP7050DE Hardware Installation and Maintenance Guide
Symbol Description
Change History
Changes between document issues are cumulative. The latest document issue contains all changes made in previous issues.
Issue 01 (2016-04-10)
Initial commercial release
About This Document
Calls attention to important information, best practices and tips.
NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii
AP7050DE Hardware Installation and Maintenance Guide Contents

Contents

About This Document.....................................................................................................................ii
1 Product Overview..........................................................................................................................1
1.1 Device Structure............................................................................................................................................................. 2
1.2 Indicator Description...................................................................................................................................................... 3
1.3 Basic Specifications........................................................................................................................................................5
1.4 Ordering Information......................................................................................................................................................6
2 AP Installation............................................................................................................................... 7
2.1 Preparing for Installation................................................................................................................................................ 8
2.2 Installation Flowchart..................................................................................................................................................... 9
2.3 Unpacking the Equipment............................................................................................................................................ 10
2.4 Determining the Installation Position........................................................................................................................... 11
2.5 Installing the AP........................................................................................................................................................... 12
2.5.1 Installing the Device on a Wall..................................................................................................................................12
2.5.2 Installing the Device on a Ceiling............................................................................................................................. 13
2.5.3 Installing the Device on a T-rail................................................................................................................................ 14
2.6 Cable Connection......................................................................................................................................................... 15
2.7 Connecting the Security Lock...................................................................................................................................... 18
2.8 Checking the Device After Installation........................................................................................................................ 19
2.9 Powering on the AP......................................................................................................................................................19
3 Logging In to the Device............................................................................................................ 20
3.1 Logging In to the Device Using STelnet/Telnet........................................................................................................... 21
3.2 Logging In to the Device Through the Console Port....................................................................................................21
4 Hardware Failures....................................................................................................................... 23
4.1 A Device Fails to Be Powered On................................................................................................................................24
5 Appendix.......................................................................................................................................26
5.1 On-site Cable Assembly and Installation..................................................................................................................... 27
5.1.1 Cable Assembly Precautions..................................................................................................................................... 27
5.1.2 Assembling Power Cables......................................................................................................................................... 28
5.1.3 Assembling Ethernet Cables......................................................................................................................................36
5.1.4 Installing Cable Accessories......................................................................................................................................50
5.1.5 Replacing the Mold of the Crimping Tool.................................................................................................................66
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iv
AP7050DE Hardware Installation and Maintenance Guide Contents
5.2 Environmental Requirements for Device Operation.................................................................................................... 69
5.2.1 Environmental Requirements for an Equipment Room............................................................................................ 69
5.2.2 Requirements for Power Supply................................................................................................................................77
5.3 Equipment Grounding Specifications...........................................................................................................................80
5.3.1 General Grounding Specifications.............................................................................................................................80
5.3.2 Grounding Specifications for an Equipment Room.................................................................................................. 80
5.3.3 Grounding Specifications for Devices.......................................................................................................................80
5.3.4 Grounding Specifications for Communications Power Supply.................................................................................81
5.3.5 Grounding Specifications for Signal Cables............................................................................................................. 82
5.3.6 Specifications for Laying Out Grounding Cables..................................................................................................... 82
5.4 Engineering Labels for Cables..................................................................................................................................... 83
5.4.1 Introduction to Labels................................................................................................................................................83
5.4.2 Engineering Labels for Optical Fibers.......................................................................................................................91
5.4.3 Engineering Labels for Network Cables................................................................................................................... 94
5.4.4 Engineering Labels for User Cables..........................................................................................................................95
5.4.5 Engineering Labels for Power Cables....................................................................................................................... 96
5.5 Guide to Using Optical Modules.................................................................................................................................. 99
5.6 Fault Tag..................................................................................................................................................................... 102
5.7 Installation Checklist.................................................................................................................................................. 103
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
v
AP7050DE Hardware Installation and Maintenance Guide
About This Chapter

1 Product Overview

1 Product Overview
The AP7050DE supports HT80 on both the 2.4 GHz and 5 GHz frequency bands and MU­MIMO (4SU-4MU), provides comprehensive service support capabilities, and features high reliability, high security, simple network deployment, automatic AC discovery and configuration, as well as real-time management and maintenance, which meets network deployment requirements. The AP complies with the 802.11ac wave2 protocol and can provide up to 2.53 Gbit/s theoretical bandwidth for wireless users, greatly improving user experience.
The AP7050DE can provide high-performance wireless service for large- to medium-sized enterprises in high-density scenarios such as mobile office, elementary education, and higher education scenarios. The AP can be deployed flexibly based on site environments.
1.1 Device Structure
1.2 Indicator Description
1.3 Basic Specifications
1.4 Ordering Information
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
71 3
5
4
2 6 8
AP7050DE Hardware Installation and Maintenance Guide

1.1 Device Structure

Figure 1-1 shows the appearance of the AP7050DE.
Figure 1-1 Appearance of the AP7050DE
1 Product Overview
Table 1-1 describes interfaces on the AP7050DE.
Table 1-1 Descriptions of interfaces
No.
1 Default Reset button: restores factory settings and restarts the
2 USB port Connects to a USB flash drive or other storage devices to
3 Console Connects to a maintenance terminal for AP configuration
4 Ground screw Connects the AP to a ground cable.
5 GE1 10/100/1000M port: connects to the wired Ethernet.
6 GE0/PoE 10/100/1000M port: connects to the wired Ethernet. The
7 DC 12V Connects to PoE or DC power supply.
Name Description
device if you hold down the button more than 3 seconds.
extend the storage space of the AP. The USB port complies with the USB 2.0 specification.
and management.
port can connect to a PoE power supply device to provide power for APs.
NOTE
When the AP uses the DC power supply, use a power adapter for power supply; otherwise, the AP may be damaged.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
Indicator
AP7050DE Hardware Installation and Maintenance Guide
No. Name Description
8 Security slot Connects to a security lock.

1.2 Indicator Description

The AP7050DE provides only one indicator, as shown in Figure 1-2.
NOTE
Indicator colors may vary slightly at different temperature.
Figure 1-2 Indicator
1 Product Overview
Table 1-2 Indicator description
Type
Default status after power-on
Software startup status
Color Status Description
Green Steady on The AP is just
Green Steady on after
blinking once
powered on and the software is not started yet.
After the system is reset and starts uploading the software, the indicator blinks green once. Until the software is uploaded and started, the indicator remains steady green.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
AP7050DE Hardware Installation and Maintenance Guide
Type Color Status Description
1 Product Overview
Running status Green Blinking once every
2s (0.5 Hz)
Blinking once every 5s (0.2 Hz)
Alarm Green Blinking once
Alarm Green every
0.25s (4 Hz)
l The system is
running properly, the Ethernet connection is normal, and STAs are associated with the AP.
l The system
enters the Uboot CLI.
The system is running properly, the Ethernet connection is normal, and no STA is associated with the AP. The system is in low power consumption state.
l The software is
being upgraded.
l After the
software is uploaded and started, the AP requests to go online on the AC and maintains this state until it goes online successfully on the AC (before the CAPWAP link is established).
l The AP fails to
go online on the AC (the CAPWAP link disconnects).
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4
AP7050DE Hardware Installation and Maintenance Guide
Type Color Status Description
Fault Red Steady on A fault that affects

1.3 Basic Specifications

Table 1-3 provides basic specifications of the AP7050DE.
1 Product Overview
services has occurred, such as a DRAM detection failure or system software loading failure. The fault cannot be automatically rectified and must be rectified manually.
Table 1-3 Basic specifications
Item
Technical specifications
Power specifications
Environment specifications
Dimensions (H x W x D)
Weight 1.3 kg
System memory
Power input
Maximum power consumption
Operating temperature
Description
53 mm x 220 mm x 220 mm
l 256 MB DDR3L
l 4 MB NOR FLASH + 128 MB NAND FLASH
l DC: 12 V ± 10%
l PoE power supply: in compliance with IEEE
802.3at
25 W
NOTE
The actual maximum power consumption depends on local laws and regulations.
l -60 m to +1800 m: -10°C to +50°C
l 1800 m to 5000 m: Temperature decreases by 1°C
every time the altitude increases 300 m.
Storage temperature
Operating humidity
IP rating IP41
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
-40°C to +70°C
5% to 95% (non-condensing)
5
AP7050DE Hardware Installation and Maintenance Guide
Item Description
1 Product Overview
Atmospheric pressure

1.4 Ordering Information

To place an order, contact technical support personnel.
Part Number
50082932 Wireless LAN Equipment,AP7050DE,11ac,Double
50082933 Wireless LAN Equipment,AP7050DE-USA,11ac,Double
50082934 Wireless LAN Equipment,AP7050DE-DC,11ac,Double
Description
Frequency,Built-in Antenna
Frequency,Built-in Antenna
Frequency,Built-in Antenna
70 kPa to 106 kPa
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6
AP7050DE Hardware Installation and Maintenance Guide
About This Chapter

2 AP Installation

2 AP Installation
2.1 Preparing for Installation
2.2 Installation Flowchart
2.3 Unpacking the Equipment
2.4 Determining the Installation Position
2.5 Installing the AP
2.6 Cable Connection
2.7 Connecting the Security Lock
2.8 Checking the Device After Installation
2.9 Powering on the AP
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
AP7050DE Hardware Installation and Maintenance Guide

2.1 Preparing for Installation

This section describes safety precautions and tool preparations for AP installation.
Safety Precautions
l Take proper measures to prevent injuries and device damage.
l Place the device in a dry and flat position away from any liquid and prevent the device
from slipping.
l Keep the device clean.
l Do not put the device and tools in the aisles.
CAUTION
Only the qualified personnel are permitted to install and remove the device and its accessories. Before installation and operation, read the safety precautions carefully.
2 AP Installation
Tool Preparation
To install APs, prepare tools listed in Table 2-1.
Table 2-1 Tools
Phillips screwdriver
Slip-proof glove Marker Hammer drill
Claw hammer Diagonal pliers Wire stripper
Protective gloves ESD gloves
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
AP7050DE Hardware Installation and Maintenance Guide
RJ45 crimping tool Cable cutter Network cable tester
Multimeter Ladder Safety helmet
Safety belt Anti-skid shoes -
2 AP Installation

2.2 Installation Flowchart

The following figure shows the process for installing an AP.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9
AP7050DE Hardware Installation and Maintenance Guide
Figure 2-1 Installation flowchart
2 AP Installation

2.3 Unpacking the Equipment

Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the equipment is rusted or soggy. Then, investigate causes and contact the supplier.
After unpacking, check items in the carton against the packing list. If any item is missing, contact the supplier or agent.
Usually, the packing list contains the following items.
l AP device
l Sheet metal mounting bracket
l OT terminal
l Power adapter (optional)
l Adjustable buckle
l Expansion screws
l Quick start guide
l Warranty card
l MAC address label
l SN label
NOTE
If a PoE adapter is required, you need to purchase it separately.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10
≥200mm
≥200mm
≥200mm
≥200mm
Floor
Celling
Wall
AP7050DE Hardware Installation and Maintenance Guide

2.4 Determining the Installation Position

Indoor APs are usually mounted on a wall or ceiling using sheet metal mounting brackets. The installation position is determined by the site survey. There must be at least 200 mm clearance between the cabling end of the AP and the wall. Figure 2-2 shows space requirements.
Figure 2-2 Mounting an AP
2 AP Installation
When determining the AP installation position, comply with the following rules:
l Try to reduce the number of obstacles, such as walls, between the AP and user terminals.
l Place the AP far away from electronic devices that may produce radio interference, such
as microwave ovens, other APs, antennas, and other radio communication devices. For
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
details, see Table 2-2.
l Install the AP in a hidden position that does not affect daily lives and work of residents.
l Install the AP in a site that is free from leaking or dripping water, heavy dew, and
humidity, and take protective measures to prevent water from flowing into the equipment along the cable.
l Do not install the AP in an environment with high temperature, dust, poisonous gases,
flammable or explosive objects, electromagnetic interference (from a radar station, radio station, or substation), unstable voltage, violent shakes, or strong noise.
Copyright © Huawei Technologies Co., Ltd.
11
AP7050DE Hardware Installation and Maintenance Guide
Table 2-2 General anti-interference requirements
Scenario Deployment Distance Requirement
2 AP Installation
Indoor installation
NOTE
If antennas are embedded into APs, the deployment distance requirements on the antennas are those on APs.
l There should be at least a 7 m distance between antennas.
l The antennas should be placed at least 2 m from the 4G antennas of
the carrier.
l The antennas should be placed far away from electronic devices that
may produce interference, such as microwave ovens.

2.5 Installing the AP

NOTE
Remove the protective film on the surface before installation to prevent electrostatic discharge.

2.5.1 Installing the Device on a Wall

Mounting APs on a wall requires sheet metal mounting brackets and expansion screws. The procedures are as follows:
1. Fix a mounting bracket against the wall and mark the drilling positions through holes of the bracket.
2. Use a 6 mm drill bit to drill 25 mm to 30 mm deep holes in the drilling positions. Hammer the expansion tubes into the holes until the expansion tubes are completely embedded into the wall.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12
b
a
AP7050DE Hardware Installation and Maintenance Guide
3. Fix the mounting bracket to the wall and use the Phillips screwdriver to fasten three expansion screws into the expansion tubes.
4. Connect the cables. For details, see 2.6 Cable Connection.
5. Align the mounting screws at the rear of the AP with the mounting holes on the sheet metal mounting bracket and then press the AP downwards to secure the AP on the bracket.
2 AP Installation

2.5.2 Installing the Device on a Ceiling

1. Remove a ceiling tile, determine locations of mounting holes based on the distance between two installation holes on the mounting bracket, use a hammer drill to drill holes on the ceiling tile, and fix the mounting bracket to the ceiling tile.
The screws provided for ceiling-mounting of APs are 30 mm long and can be used to fix an AP on a ceiling not thicker than 15 mm. To install APs on thicker ceilings, you need to purchase longer screws.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13
a
b
AP7050DE Hardware Installation and Maintenance Guide
1. Ceiling tile 2. Adjustable buckle 3. M4x30 screw
2. Connect the cables. For details, see 2.6 Cable Connection.
3. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting holes on the bracket and push the AP horizontally to secure the AP.
2 AP Installation
NOTE
Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above and around the AP for maintenance.

2.5.3 Installing the Device on a T-rail

1. Remove two ceiling tiles around the T-rail, use screws to fix the adjustable buckle to the mounting bracket, hook the adjustable buckle to the T-rail, and secure the screw on the adjustable buckle to fasten the mounting bracket and T-rail.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14
a
b
AP7050DE Hardware Installation and Maintenance Guide
2. Connect the cables. For details, see 2.6 Cable Connection.
3. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting holes on the bracket and push the AP horizontally to secure the AP.
2 AP Installation
NOTE
l Before fixing the adjustable buckle with a screw, you need to adjust the buckle to a proper position
based on the T-rail width.
l Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space
above and around the AP for maintenance.

2.6 Cable Connection

Figure 2-3 describes the cable connections.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15
43
1
2
AP7050DE Hardware Installation and Maintenance Guide
Figure 2-3 Appearance of the AP7050DE
Table 2-3 Cable connections
2 AP Installation
No.
Cable or Device Description
1 USB flash drive Connects to a USB flash drive to extend the storage space
of the AP. The USB2.0 standard is supported.
2 Ground cable Connects the AP to the ground.
3 Network cable
l CAT5E cables or higher must be used.
l The service network cable cannot be connected to the
console port; otherwise, the AP may be damaged when using PoE power supply. The network cable length cannot exceed 100 m.
l If the AP needs to connect to the Ethernet, ensure that
the Ethernet cable is working properly. If the Ethernet cable is not working properly, for example, RJ45 connectors are short-circuited, the AP may fail to be powered on or fail to work. Before connecting an Ethernet cable to the AP, use the cable test tool to check whether the cable is qualified. If the cable is unqualified, replace it.
4 DC power adapter When the AP uses the DC power supply, use a power
adapter for power supply; otherwise, the AP may be damaged.
NOTE
The AP is powered by either the DC power supply or PoE power supply that backs up each other.
Pay attention to the following points when bundling the cables:
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
16
AP7050DE Hardware Installation and Maintenance Guide
l Different types of cables must be separately routed with the minimum spacing of 30 mm
and cannot be entangled or crossed. Cables should be parallel or separated using dedicated separators.
l Bundled cables are closely arranged, straight, tidy, and undamaged.
l Cable ties are bound neatly facing the same direction, and those at the same horizontal
line must be in a straight line. Cable tie tails should be cut smoothly and evenly.
l Labels or nameplates must be attached to the cables after they are installed.
Connecting USB Flash Drivers
To ensure compatibility between USB flash drives and devices, use Huawei-certified USB flash drives (listed in Table 2-4) to configure the Huawei devices.
Table 2-4 Huawei-certified USB flash drives
2 AP Installation
Capacity
4 GB Netac U208 You can buy Netac USB 4 GB flash
8 GB Netac U208 Huawei does not offer this USB flash
Vendor Model Remarks
drives from Huawei or other vendors.
SanDisk Cruzer Blade Huawei does not offer this USB flash
drive, and you need to buy it from other vendors.
Hewlett­Packard
PNY M1 Huawei does not offer this USB flash
Hewlett­Packard
STEC SLUFD8GU2TUIHuawei does not offer this USB flash
v218G Huawei does not offer this USB flash
drive, and you need to buy it from other vendors.
drive, and you need to buy it from other vendors.
drive, and you need to buy it from other vendors.
v225w Huawei does not offer this USB flash
drive, and you need to buy it from other vendors.
drive, and you need to buy it from other vendors.
Connecting the Ground Cable
Use ground screws and ground cables to ground the AP. The ground cables need to be prepared on site. The M6 OT terminal is used to connect to the AP and M8 OT terminals to the ground bar. The type of OT terminals can also be determined according to site surveys. Cut the cable into the required length according to site conditions.
Tighten the OT terminal for the AP with a torque of 3 N•m. The tightening torque for the ground bar varies according to the OT terminals used.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17
Lock holeSecurity lock
AP7050DE Hardware Installation and Maintenance Guide
l M4: 1.4 N•m
l M6: 4.8 N•m
l M8: 12 N•m
Ground cable deployment requirements are as follows:
l The ground cables must be connected to a group of ground bars.
l The bend radius of the ground cables must be larger than or equal to five times the cable
diameter.
l The ground cables must be buried underground or routed indoors and cannot be led into
the equipment room aerially.
l Both ends of the external conductor of the coaxial cable and those of the shield layer of
the shielded cable should have good electric contact with the metal shell of the equipment they connect to.
l Ground cables must be separated from signal cables to reduce interference between
them.
l Do not add any switch or fuse on the ground cable.
2 AP Installation
l Do not use another device for an electrical connection with the ground cable.
l All metal components in the shell must be securely connected to the ground terminal.

2.7 Connecting the Security Lock

There is a security slot on the device. You can lock the device to an immovable object to prevent theft. The detailed procedures are as follows:
1. Fasten the cable of the security lock to an immovable object around.
2. Insert the security lock into the security slot and lock it.
NOTE
You need to purchase the security lock separately.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18
AP7050DE Hardware Installation and Maintenance Guide

2.8 Checking the Device After Installation

Table 2-5 shows the items to be checked after installation is complete. For more details, see
Installation Checklist in the appendix.
Table 2-5 Installation checklist
2 AP Installation
No.
1 The device is installed by strictly following the design draft. The
2 The device is securely installed.
3 The power cables and PGND cables are intact and not spliced.
4 Terminals of the power cables and PGND cables are welded or cramped
5 All power cables or PGND cables are not short-circuited or reversely
6 The power cables and ground cables are separated from other cables and
7 The working ground, protection ground, and surge protection ground
8 Connectors of signal cables are complete, intact, and tightly connected.
9 Labels on cables, feeders, or jumpers are clear and correct.
Check Item
installation position meets space requirements, with maintenance space reserved.
firmly.
connected and must be intact with no damage.
bundled separately.
share the same group of ground bars.
The signal cables are not damaged or broken.

2.9 Powering on the AP

After the AP installation is complete, observe indicator on the AP to determine the system running status. For details, see 1.2 Indicator Description.
NOTE
Do not frequently power on and off the device.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
19
AP7050DE Hardware Installation and Maintenance Guide
About This Chapter

3 Logging In to the Device

3 Logging In to the Device
3.1 Logging In to the Device Using STelnet/Telnet
3.2 Logging In to the Device Through the Console Port
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20
AP7050DE Hardware Installation and Maintenance Guide
3 Logging In to the Device

3.1 Logging In to the Device Using STelnet/Telnet

You can log in to the device using STelnet V2 or Telnet to configure, manage, and maintain the device in the CLI.
NOTE
l By default, only the STelnet V2 service is enabled on the device.
l Telnet has security vulnerabilities. You are not advised to enable the Telnet service.
Before logging in to the device, complete the following tasks:
l Power on the device.
l Prepare network cables used to connect device interfaces.
The following table lists the default configuration of the device. You are advised to change the default user name and password on your first login.
Table 3-1 Default configuration of the device
Parameter
User name admin
Password admin@huawei.com
IP address 169.254.1.1
Subnet mask 255.255.0.0
NOTE
If the device is already online on the AC, you can remotely log in to the AC on a local terminal and run the display ap all command to check the IP address of the device.
The following example uses the default parameters and is used for reference only.
Step 1 Use network cables and a LAN switch to connect the PC to the network interface of the
device.
Step 2 Assign the PC with an IP address on the same network segment as the default IP address of
the device so that the PC and device are reachable to each other.
If the device uses the default settings, the IP address of the PC must be in the network segment 169.254.0.0/16 but cannot be 169.254.1.1. 169.254.1.100 is recommended.
Default Setting
Step 3 Start the CLI on the PC and access the IP address 169.254.1.1 of the device using STelnet V2.
Step 4 Enter the user name and password as prompted to log in to the user interface.
----End

3.2 Logging In to the Device Through the Console Port

Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
21
AP7050DE Hardware Installation and Maintenance Guide
Before logging in to the device, complete the following tasks:
l Power on the device.
l Prepare a console cable.
l Prepare terminal simulation software.
NOTE
If your PC's operating system provides terminal simulation software (like HyperTerminal in Windows 2000/ XP), you do not need to install additional terminal simulation software. If the PC runs on an operating system without terminal simulation software (like Windows 7), install third-party terminal simulation software on the PC by referring to the user manual or online help.
Step 1 Use a console cable to connect the PC to the console port of the device.
Step 2 Start terminal emulation software on the PC, create a connection, and set communication
parameters as follows:
l Bits per second: 9600
l Data bits: 8
l Parity: None
l Stop bits: 1
l Flow control (F): None
3 Logging In to the Device
Step 3 Press Enter and enter the default user name admin and password admin@huawei.com as
prompted to log in to the user view. (The following information is only for reference.)
Login authentication
Username: Password: Info: You are advised to change the password to ensure security.
You are advised to change the default user name and password on your first login.
----End
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22
AP7050DE Hardware Installation and Maintenance Guide
About This Chapter

4 Hardware Failures

4 Hardware Failures
This section describes common methods for troubleshooting typical hardware faults.
4.1 A Device Fails to Be Powered On
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
23
AP7050DE Hardware Installation and Maintenance Guide

4.1 A Device Fails to Be Powered On

Fault Description
The SYS indicator of a device is off.
Possible Causes
4 Hardware Failures
Power Supply Mode
Power supply using a power module
PoE power supply
Possible Cause
l The device is powered off.
l The power cable is not securely
connected to the device.
l The power supply unit has failed.
– If the device connects to an external
power source, its power adapter may fail.
– If the device has a built-in power
supply, the device itself may be faulty.
l The power sourcing equipment does not
support the PoE function or is faulty.
l The power sourcing equipment is
incorrectly configured (the PoE function is disabled or the power-off time range is improperly set).
l The line is faulty (the network cable or
distribution frame is damaged).
l The device is faulty.
Issue 01 (2016-04-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
24