No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trad emarks and Permis sions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
This document describes hardware features of the AP4130DN and provides basic installation
methods.
This document is intended for::
Network planning engineers
Hardware installation engineers
Commissioning engineers
Onsite maintenance engineers
System maintenance engineers
Symbol Conventions
The symbols that may be found in this docume nt are defined as follows.
Symbol Description
Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, could result in death
or serious injury.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury.
Indicates a potentially hazardous situation
which, if not avoided, could result in
equipment damage, data loss, performance
deterioration, or unanticipated results.
NOTICE is used to address practices not
related to personal injury.
Calls attention to important information,
best practices and tips.
1.4 Global Environmental Compliance............................................................................................................................... 9
2 AP Installation ............................................................................................................................. 11
2.1 Preparing for Installation ............................................................................................................................................ 1 1
2.2 Unpacking the Equipment ................................................................................................... ....................................... 12
2.3 Determining the Installation Position ......................................................................................................................... 13
2.4 Installing the AP ......................................................................................................................................................... 14
2.4.1 W a ll Mounting ......................................................................................................................................................... 14
2.7 Powering on the AP .................................................................................................................................................... 19
3 Logging In to the AP ................................................................................................................... 20
3.1 Logging In to the AP Through the Console Port ......................................................................................................... 20
3.2 Logging In to the AP Using STelnet ........................................................................................................................... 21
3.3 Logging In to the AP Using a Web Client ................................................................................................................... 23
The AP4130DN is deployed indoors and feature high reliability, high security, simple network
deployment, automatic AC discovery and configuration, and real-time management and
maintenance.
Huawei indoor APs are especially applicable to places with simple building structure, small
size, dense users, and high capacity demands, such as small-size conference rooms, bars, and
leisure centers. They can be flexibly deployed according to surrounding environment.
1.1 Device Structure
1.2 Indicator Description
1.3 Basic Specifications
1.1 Device Structure
Figure in Figure 1-1 shows the appearance of AP4130DN.
Table in Table 1-1 shows the interface of AP4130DN.
Table 1-1 Interfaces on AP4130DN
No. Name Description
1
2.4G/5G/Dual-band
antenna
Connects a 2.4G/5G/Dual-band GHz antenna to
the AP to transmit and receive service signals.
2 GE/PoE 10/100/1000M bit/s interface: connects to the
wired Ethernet. The interface can connect to
a PoE power supply to provide power for the
AP.
3 DC power adapter The AP supports the PoE power supply and DC
power supply.
To connect the AP to a DC power source, use
the power adapter delivered with the AP;
otherwise, the AP maybe damaged.
4 Security slot Fasten the cable of the security lock to an
immovable object around, and insert the
security lock into the security slot and lock it.
1.2 Indicator Description
The following information describes indicators on the AP4130DN.
The actual indicator color may vary according to temperature.
After an AP is powered on, you can run the led off command on the AC to turn off all AP indicators.
To restore the indicators to normal working status, run the led on command.