Huawei AP4030DN, AP4130DN quick start Guide

AP Series Indoor Wireless LAN Access Points
1
1
2
3
4
2
2
1
UP
c
b
a
a
c
b
a
c
b
a
b
c
30 mm ~ 35 mm
1
3
2
PASS
Qualification Card
Connecting Cables
Quick Start Guide
10 (2019-06-19)
Packing List
AP device (with the product model on the nameplate)·Antenna
·
Sheet metal mounting bracket
·
Power adapter (optional)·MAC address label
·
NOTE
The packing list and gures in the document are for reference only and may be different from actual devices.
Warranty card
·
·
SN label
·
Safety Guidelines
Observe all safety regulations and precautions
To ensure personal and equipment safety, observe all the safety precautions on the equipment and in this document.
·
contents do not cover all the safety precautions and are only supplementary.
CAUTION
Follow all the safety precautions and instructions provided by Huawei. The safety precautions outlined in this document
·
are only those that Huawei can predict. Huawei is not liable for any consequence that results from violation of regulations pertaining to safe operations or safety codes pertaining to design, production, and equipment use.
CAUTION
Take ESD protection measures during equipment installation and maintenance. For example, wear ESD gloves or an ESD wrist strap.
·
During equipment transport and installation, prevent the equipment from colliding with objects like doors, walls, or shelves. Do not touch
·
unpainted surfaces of the parts or components with wet or contaminated gloves.
Default
5
1
3 4
2
The Cable Connections of indoor APs:
No. Cable Description
1 2.4G/5G dual-band antenna
Connects a 2.4G/5G Dual-band antenna to the AP to send and receive wireless
signals. This port is provided only on APs that support external antennas.
2 Console Connects to a maintenance terminal for AP conguration and management.
3 GE/PoE Connects to the wired Ethernet and supports PoE input.
The AP supports the PoE power supply and DC power supply.
·
4 DC 12V
To connect the AP to a DC power source, use the power adapter delivered with the
·
AP; otherwise, the AP maybe damaged.
5 Security slot
Fasten the cable of the security lock to an immovable object around, and insert the security lock into the security slot and lock it.
Site Environment
Install the device in an environment free of high temperature, dust, unstable voltage, vibration, strong noise, and noxious,
·
ammable, or explosive gases or smoke, as well as free of interference sources such as large radar stations, radio stations,
and electrical substations.
Install the AP in a dry environment away from sources of water, and take protective measures to prevent water from owing
·
into the equipment along the cable.
Install the device in a hidden places and ensure that the device do not disturb daily work and life of residents.
·
Make the engineering design by fully considering such factors as climate, hydrology, geology, earthquake, electric power, and
·
trafc. The selected site should comply with the environment design specications of communications equipment.
Select installation positions based on the site survey. Leave at least 200 mm clearance between the outlet and the wall.
·
The mounted position should be able to bear four times the total weight of the device and mounting bracket. When the total
·
weight of the device and mounting bracket is less than 1.25 kg, the load bearing capability of the wall must be greater than or equal to 5 kg
.
Installing the Device
Scenario 1: Wall Mounting Scenario 2: Ceiling Mounting
When fixing the sheet metal mounting bracket, ensure that the arrows point upwards on the label.
Attach the mounting bracket against the wall and adjust its position properly. Mark positions of the mounting holes with a marker.
56 mm
Remove a ceiling tile and determine locations of mounting holes based on the distance between two installation holes on the mounting bracket. Use a hammer drill to drill holes on the ceiling tile and fasten the mounting bracket with the ceiling tile.
47 mm
Pay attention to the following points when installing external antennas:
Antennas of the outdoor APs must comply with local laws and regulations.
·
Antennas need to be installed by qualied personnel. An AP can only use the antennas delivered with it.
·
Pay attention to the following points when installing cables:
Before connecting an Ethernet cable to the AP, use the cable test tool to check whether the cable is qualied. If the cable is
·
unqualied, replace it.
The service network cable and PoE input cable cannot be connected to the console port.
·
The cable cannot exceed 100 meters.
·
The network cable must be a Cat5e cable or higher specications.
·
NOTE
For details about cable connections, log in to Support-E and see "Cable Connection" in of this AP model.
Hardware Installation and Maintenance Guide
Logging In to the Device for the First Time
Wired Connection Mode:
By default, the IP address and subnet mask of the device are
·
password are
You are advised to change the user name and password on your rst login.
·
If the device works as a Fit AP and is already online on the AC, you can remotely log in to the AC and run the
·
check the IP address of the device.
admin
admin@huawei.com
and
. Congure an IP address on
169.254.1.1
NOTE
For details about cable connections, log in to Support-E and see "Logging In to the Device" in AP model.
255.255.0.0
and
169.254.x.x
, respectively. The default user name and
(excluding
169.254.1.1
Hardware Installation and Maintenance Guide
) for the PC.
display ap all
command to
of this
85 mm
Use a 6 mm drill bit to drill 30 mm to 35 mm deep holes in the marked positions. Hammer the expansion tubes into the holes until they are completely embedded into the wall.
Ø6
Fix the mounting bracket to the wall, and use the Phillips
90
screwdriver to fasten three expansion screws into the expansion tubes.
M4
1.4 N•m
1. Ceiling tile 2. Adjustable buckle 3. M4x30 screw
NOTE
The screws provided for ceiling-mounting are 30 mm long and
can be used to fix the device on a ceiling not thicker than 15
mm.To install devices on thicker ceilings, customers need to
purchase longer screws.
Align the rubber feet of the device over the mounting slots on the mounting bracket and vertically push the AP to secure it. When the spring clip is popped up, push the AP horizontally until it snaps into place (you can hear a click).
Common Errors in Network Planning
No. Error Case Analysis Corrective Action
1 Fat APs are used to achieve
large-scale wireless network coverage.
2 Antennas are deployed too
close, or electromagnetic interference exists near the antennas.
3 An indoor settled AP is deployed
in a corridor to provide wireless coverage for the six rooms on both sides of the corridor.
Fat APs are applicable only to
small-scale SOHO ofce scenarios
and cannot implement inter-AP
roaming. Therefore, Fat APs are
not recommended in large-scale coverage scenarios.
Signal interference affects data transmission.
Generally, washing rooms or compartments exist in rooms. Radio signals attenuate significantly when penetrating walls, which affects service experience. Densely deployed APs in the corridor can also lead to co-channel interference. Such a plan is not recommended.
In large-scale wireless network coverage scenarios, use the AC+Fit AP networking.
Properly control the distance between antennas. It is recommended that you comply with the following requirements:
1. Ensure that antennas are deployed no less than 7 m. In semi-open indoor areas, ensure that APs are around 20 m away from each other.
2. Deploy antennas at least 5 m away from 4G antennas.
3. Keep antennas away from electronic equipment that may cause radio interference, such as microwave ovens.
In a scenario where rooms are on both sides of the corridor, you are advised to deploy agile distributed devices or wall plate APs in the rooms to implement indoor coverage. Alternatively, you can deploy indoor settled APs in the rooms in W-shaped mode. Do not deploy indoor settled APs in two rooms facing each other on both sides of the corridor.
ST3.5
1.2 N•m
Align the rubber feet of the device over the mounting slots on the mounting bracket and vertically push the AP to secure it. When the spring clip is popped up, push the AP downward until it snaps into place (you can hear a click).
Scenario 3: T-rail Mounting
Remove two ceiling tiles around the T-rail, use screws to
fix the adjustable buckle to the mounting bracket, hook
the adjustable buckle to the T-rail, and secure the screw
on the adjustable buckle to fasten the mounting bracket
and T-rail.
3
1
4
Obtaining Product Documentation and Technical Support
You can obtain the latest product documentation at http://support.huawei.com/enterprise. Log in to the website,
and select a specic product model and version to download its documentation. If the instructions contained
NOTE
Ensure that the device is securely installed on the mounting bracket and leave a certain space above and around the device for maintenance.
in the product documentation are insufficient to resolve problems that occur during device operation or
maintenance, contact Huawei Technical Assistance Center for technical support.
Enterprise network technical bulletin: http://support.huawei.com/ecommunity
Scan the QR code to download more documents.
Open Source Software Notice
The Open Source Software Notice lists notices on open source software components used by the product.
Open Source Software Notice
Qualication Card
at the lower right corner of the
Align the rubber feet of the device over the mounting slots on the mounting bracket and vertically push the AP to secure it. When the spring clip is popped up, push the AP horizontally until it snaps into place (you can hear a click).
You can open the web login page of the AC or Fat AP, and click page to view details about the open source software notice.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Copyright © Huawei Technologies Co., Ltd. 2019 All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means
without prior written consent of Huawei Technologies Co., Ltd.
M4
1.4 N•m
2
1. T-rail 2. M4x8
Screw
Adjustable
3.
buckle
Sheet metal
4.
mounting bracket
NOTE
Before fixing the adjustable buckle with a screw, you need to
adjust the buckle to a proper position based on the T-rail width.
Installation Precautions
After the AP is installed on the mounting bracket, to further
·
strengthen the fastening effect, tighten an M4x30 screw on the mounting bracket.
The T-rail, or the wall, or the ceiling needs to bear the weight
·
of four times the total weight of the device and mounting bracket without damage.
The following figure shows the T-rail dimensions
·
requirements (t: thickness; w: width).
NOTE
Ensure that the device is securely installed on the mounting bracket and leave a certain space above and around the device for maintenance.
Removing an AP
Flip the spring clip on the mounting bracket and slip the AP towards the spring clip. Release the spring clip until the rubber feet of the AP enter the mounting keyholes. Remove the AP from the mounting bracket.
NOTE
If a captive screw is installed, remove the screw and then follow the preceding steps to uninstall the AP.