Dual-port 10 Gigabit
Dual-port 10 GigabitDual-port 10 Gigabit
Dual-port 10 Gigabit
Ethernet Throughput
Ethernet ThroughputEthernet Throughput
Ethernet Throughput
The NC550m 20,000 Mbps full duplex Ethernet transfer rate per port (40 Gbps aggregate full duplex)
delivers outstanding network performance that improves response time and removes bottlenecks required
for the next generation data center.
HP Virtual Connect Flex-
HP Virtual Connect Flex-HP Virtual Connect Flex-
HP Virtual Connect Flex10 10Gb Ethernet
10 10Gb Ethernet10 10Gb Ethernet
10 10Gb Ethernet
Module for the c-Class
Module for the c-ClassModule for the c-Class
Module for the c-Class
BladeSystem
BladeSystemBladeSystem
BladeSystem
Evolve 10Gb at your own speed! When paired with the HP Virtual Connect Flex-10 10Gb Ethernet
Modules, take advantage of the Flex Nics, which are PCI Physical Function devices that are OS
independent.
Server ROM recognizes them as individual NICs
Speeds can be set per NIC from 100Mb to 10Gbs in 100Mb increments
Three fold increase in number of network connections per port.
Up to four physical function NICs per port
Jumbo Frames
Jumbo FramesJumbo Frames
Jumbo Frames
The NC550m support for jumbo frames (also known as extended frames) permit up to a 9K byte
transmission unit (MTU), which is over five times the size of standard 1500 byte Ethernet frame. The use
of jumbo frames is a way to achieve higher throughput and better CPU utilization. Jumbo frames are
particularly useful for database transfers and tape backups.
802.1p QoS Tagging
802.1p QoS Tagging802.1p QoS Tagging
802.1p QoS Tagging
IEEE quality of service (QoS) 802.1p tagging allows the adapter to mark or tag frames with a priority
level across a QoS-aware network for improved traffic flow.
TCP/IP Stateless
TCP/IP StatelessTCP/IP Stateless
TCP/IP Stateless
Offloading
OffloadingOffloading
Offloading
For overall improved system response, the NC550m supports standard TCP/IP stateless offloading
techniques including:
TCP/IP checksum offload (TCO) moves the TCP and IP checksum offloading from the CPU to the
network adapter.
Large send offload (LSO), also known as TCP segmentation offload (TSO), allows TCP
segmentation to be handled by the adapter rather than the CPU.
802.1Q VLANs
802.1Q VLANs802.1Q VLANs
802.1Q VLANs
IEEE 802.1Q virtual local area network (VLAN) protocol allows each physical port of the NC550m to be
separated into multiple virtual NICs for added network segmentation and enhanced security and
performance. VLANs increase security by isolating traffic between users. Limiting the broadcast traffic to
within the same VLAN domain also improves performance.
TOE
TOETOE
TOE
TCP/IP Offload Engine (TOE) moves the processing of data in the TCP protocol stack from the server
CPU to the network card, freeing CPU cycles for other duties.
RDMA
RDMARDMA
RDMA
Not Supported
iSCSI
iSCSIiSCSI
iSCSI
The NC550m does not support accelerated iSCSI or iSCSI boot.
QuickSpecs
HP NC550m 10GbE 2-port PCIe x8 Flex-10 Ethernet
HP NC550m 10GbE 2-port PCIe x8 Flex-10 EthernetHP NC550m 10GbE 2-port PCIe x8 Flex-10 Ethernet
HP NC550m 10GbE 2-port PCIe x8 Flex-10 Ethernet
Adapter
AdapterAdapter
Adapter
Performance
DA - 13561 Worldwide — Version 4 — April 8, 2011
Page 3