The HP 60 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 3.5 inch SAS,
Serial ATA (SATA) and SAS Midline (MDL) drives. This enclosure delivers industry-leading data performance, availability, storage
density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 3.5
inch Universal SAS, SATA or SAS MDL hard drive form factors. The MSA60 enclosure supports direct attach storage (DAS) to HP
ProLiant and HP Integrity Servers. The MSA60 supports the cascading of shelves in a 1+3 configuration to allow a maximum of 48
drives in an 8U configuration behind each of the two external ports on the HP Smart Array P800, the HP Smart Array E500, HP
Smart Array P411 or the HP Smart Array P812 Controllers for a total of 96 drives in 8 enclosures (this single controller port
incorporates four lanes for a total max throughput of 12Gb/s for SAS). On HP ProLiant servers Dual Domain support is available for
the HP Smart Array P800 attached to a MSA60 with the addition of the HP Dual Domain I/O Module Option (AG779A). (Single
initiator environment only). (
The MSA60 also supports the HP Smart Array P600 and the HP Smart Array P212 Controllers. Behind the single external port on the
HP Smart Array P600 or the P212 Controllers 1+3 cascading allows a maximum of 48 drives in an 8U configuration. (
Smart Array P212 Controller is supported on ProLiant servers only
For HP-UX and Open VMS environments on HP Integrity Servers the MSA60 supports the HP (AH303A) SC44Ge Host Bus Adapter
with the addition of the HP Dual Domain I/O Module Option (AG779A). Behind the single external port on the HP (AH303A)
SC44Ge Host Bus Adapter 1+3 cascading allows a maximum of 48 drives in an 8U configuration. The HP (AH303A) SC44Ge Host
Bust Adapter will only support HP-UX and Open VMS environments and will be available on all rack mounted HP Integrity Servers
with PCIe slots.
NOTE:
NOTE:
Smart Array P411 and P812 Controllers are supported on ProLiant servers only
NOTE:NOTE:
).
).
NOTE:
NOTE:
NOTE:NOTE:
The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will support
HP-UX and Open VMS on selected HP Integrity servers only. The MSA60 with the I/O Module and the HP SC44Ge Host Bus Adapter
will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only.
Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only.
HP Serviceguard monitors the health of each node and rapidly responds to failures in a way that minimizes or eliminates application
downtime.
NOTE:
NOTE:
HP Integrity servers that are supported:
NOTE:NOTE:
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)
What's New
What's New
What's NewWhat's New
Introducing support for the new HP Smart Array Controller for the MSA60 with ProLiant servers
HP Smart Array P812 Controller/1G Flash Backed Cache Controller
Introducing support for new drives
HP 2 TB 3G SATA 7.2K LFF (3.5 inch) MDL HDD
HP 1 TB 6G SAS 7.2K LFF (3.5 inch) DP MDL HDD
HP 2 TB 6G SAS 7.2K LFF (3.5 inch) DP MDL HDD
DA - 12627 North America — Version 37 — June 8, 2011
Page 1
QuickSpecs
Overview
HP 60 Modular Smart Array
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
Front panel LEDs and buttons
Front panel LEDs and buttons
Front panel LEDs and buttonsFront panel LEDs and buttons
1.
Heartbeat LED
2.
Fault LED
3.
UID button/LED
Rear Panel components
Rear Panel components
Rear Panel componentsRear Panel components
1.
Power Supply 1
2.
System fan 1
3.
Dual 7 segment display board (for future use)
4.
SAS in connector
5.
SAS out connector
6.
I/O module bay
7.
I/O module bay
8.
System fan 2
9.
Power supply 2
DA - 12627 North America — Version 37 — June 8, 2011
Page 2
QuickSpecs
HP 60 Modular Smart Array
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
Overview
At A Glance
At A Glance
At A GlanceAt A Glance
2U rackmount form factor
3 Gb/s SAS host connectivity
Dual Domain support with HP Smart Array P800 Controller for HP ProLiant and Integrity servers (requires dual port SAS
drives)
Multi Initiator support with the SC44Ge Host Bus Adapter (AH303A) (HP-UX and Open VMS on selected HP Integrity Servers)
with dual port SAS drives only
Supports HP SAS single port and dual port 3G SAS disk drives, (72 GB, 146 GB, 300 GB & 450 GB 15K & 400 GB 10K
capacities) and 6G DP SAS disk drives (300GB, 450GB & 600GB 15K capacities)
Ability to support HP SAS dual port MDL (Midline) 6G disk drives (1 TB and 2 TB capacities)
Compatible with HP SATA 3G disk drives, (500 GB, 1 TB and 2 TB capacities)
Maximum storage capacity of 7.2 TB (with twelve HP SAS 6G 600 GB hard drives) or 24 TB (with twelve HP SATA 3G 2 TB
hard drives or 2 TB SAS MDL drives)
1+3 Cascade support (behind a single SAS port)
Supports boot from storage
Redundant hot-plug power supplies and fans standard
Addition of second I/O Module adds Dual Domain capability providing higher level of redundancy and reliability
DA - 12627 North America — Version 37 — June 8, 2011
Page 3
QuickSpecs
Standard Features
Modular Smart Array
Modular Smart Array
Modular Smart ArrayModular Smart Array
Family
Family
FamilyFamily
MSA60
MSA60
MSA60MSA60
Key Features
Key Features
Key FeaturesKey Features
The HP Modular Smart Array family delivers simple, affordable storage technology to meet today's
demanding and growing IT needs. These storage solutions offer the best price/performance and best
price/availability features for direct attach environments, small clusters, workgroups and entry-level SAN
environments. Each solution is designed for easy deployment, secure operation, and reduced
management costs while driving rapid return on investment.
The HP MSA60 Enclosure (hereafter referred to as "MSA60") is a disk drive storage enclosure with 3G
SAS host connectivity. These enclosures deliver industry-leading availability, storage density, and
upgradeability to meet customers' demanding and growing storage needs. The MSA60 delivers the ideal
mix of low-cost and high capacity, for minimum I/O workloads such as reference data, archival, and
disk-to-disk backup.
2U rackmount form factor
SAS host interface
Dual Domain support with HP Smart Array P800 Controller (requires dual port SAS drives)
Multi Initiator support with the SCG44e Host Bus Adapter (AH303A) (HP-UX and Open VMS on
selected HP Integrity Servers) with dual port SAS drives only
Supports twelve 3.5-inch hot pluggable drives
Ability to support, 72 GB ,146 GB, 300 GB & 450 GB 15K and 400 GB 10K 3.5 inch 3G SAS
single port and dual port drives, and 300GB, 450GB & 600GB 6G SAS dual port drives
Ability to support HP 6G SAS dual port MDL (Midline) disk drives (1 TB & 2 TB capacities)
Compatible with HP SATA 3G disk drives, (250 GB, 500 GB, 750 GB, 1 TB & 2 TB capacities)
Modular design
1+3 Cascade support (behind a single SAS port)
SATA 3G - Delivering data transfer rates greater than 100 MB/s
Provides storage capacity of up to 7.2 TB per enclosure using 6G , 600GB DP SAS disk drives
Provides storage capacity of up to 24 TB per enclosure using 2 TB SATA disk drives or 2 TB SAS
MDL HDD
Hot pluggable disk drives, power supplies, and fans
Redundant fans and power supplies ship as standard equipment with base enclosure
Each MSA60 enclosure comes with dual power supplies that are sufficient to provide power to the
enclosure and maintain normal operating levels
Integrated Environmental Monitoring - Monitors environmental conditions within the enclosure
and components such as the power supply, fans and temperature
Easy removal of parts provides better serviceability. No tools are required!
Supports MS Windows 2003, MS Windows 2008, Red Hat Linux, SUSE Linux, Novell NetWare,
HP-UX 11iv2 and 11iv3, Open VMS 8.3 1H
Supported with Smart Array P800, the Smart Array E500, the Smart Array P600, the Smart Array
P411, the Smart Array P212 or the HP Smart Array P812 Controller for HP ProLiant Servers and
HP Integrity Servers in a single initiator environment. (NOTE: Smart Array P411, P212 & P812
Controllers are supported on ProLiant servers only).
Attached to HP SC44Ge Host Bus Adapter for HP-UX and Open VMS support on selected HP
Integrity Servers (servers that support PCI-e cards)
Supported with ACU, ORCA and HP Systems Insight Manager through configuration utilities
provided via the Smart Array controller
RoHS compliant
3 year limited warranty (MSA60 enclosure only)
Pre-Failure warranty that covers SAS and SATA disk drives (See note below)
HP 60 Modular Smart Array
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
DA - 12627 North America — Version 37 — June 8, 2011
Page 4
QuickSpecs
Standard Features
NOTE:
NOTE:
Customer must be running HP Systems Insight Manager in order to qualify for Pre-Failure
NOTE:NOTE:
warranty. The enclosure is only covered for the warranty period of the drive (3 years for SAS and 1 year
for SAS Midline (MDL) and SATA drives).
HP 60 Modular Smart Array
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
DA - 12627 North America — Version 37 — June 8, 2011
Page 5
QuickSpecs
Product Highlights
High Levels of Storage
High Levels of Storage
High Levels of StorageHigh Levels of Storage
Density, Data Protection,
Density, Data Protection,
Density, Data Protection,Density, Data Protection,
and Functionality
and Functionality
and Functionalityand Functionality
Storage Capacity
Storage Capacity
Storage CapacityStorage Capacity
of 7.2 TB SAS drives or 24 TB with SATA or SAS MDL drives
Data Protection
Data Protection
Data ProtectionData Protection
fans and power supplies (standard), and support for various RAID level including RAID6 with ADG
(depending upon the Smart Array Controller used)
Dual Domain
Dual Domain
Dual DomainDual Domain
The redundant paths created by these configurations reduce or eliminate single points of failure
within the storage network. This provides increased levels of high availability with redundant paths
from the controller to the drives.
Storage Manageability
Storage Manageability
Storage ManageabilityStorage Manageability
as Array Configuration Utility (ACU) and HP Systems Insight Manager (SIM). Online Management
Features include: Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size
Migration, Online Spares (Global)
Choice of Computing Platform
Choice of Computing Platform
Choice of Computing PlatformChoice of Computing Platform
Integrity servers
Advanced Data Guarding
Advanced Data Guarding
Advanced Data GuardingAdvanced Data Guarding
across drives and allows simultaneous write operations. This level of fault tolerance can withstand
two simultaneous drive failures without downtime or data loss.
HP 60 Modular Smart Array
HP 60 Modular Smart Array
HP 60 Modular Smart ArrayHP 60 Modular Smart Array
- The MSA60 enclosure supports up to 12 SAS drives for a maximum capacity
- MSA60 is designed for a high level of data protection. It includes redundant
- Dual domain SAS creates redundant pathways from servers to storage devices.
- The MSA60 features familiar configuration and management tools such
- The MSA60 is designed and qualified for HP ProLiant and HP
(RAID 6 with ADG)
Fault Tolerance
Fault Tolerance
Fault ToleranceFault Tolerance
- It allocates two sets of parity data
Low Total Cost of
Low Total Cost of
Low Total Cost ofLow Total Cost of
Ownership
Ownership
OwnershipOwnership
The modular, scalable design of the MSA60 provides an extremely flexible platform. You can buy what
you need today and purchase additional capacity as your data storage needs grow, instead of making a
large up-front investment. Additional drives and enclosures can be easily added as your needs dictate.
Cascading
Cascading
CascadingCascading
a single SAS port (depends on the Smart Array Controller).
Tiered Storage
Tiered Storage
Tiered StorageTiered Storage
you to more effectively utilize mission critical storage where you need it most.
Universal SATA Hard Drive
Universal SATA Hard Drive
Universal SATA Hard DriveUniversal SATA Hard Drive
investment in disk drives is protected and cost is minimized as you add new drives.
Pre-Failure Warranty
Pre-Failure Warranty
Pre-Failure WarrantyPre-Failure Warranty
Manager are supported by a Pre-Failure (replacement) Warranty (3 years for SAS and 1 year for
SAS MDL and SATA drives). Pre-Failure Warranty allows for the replacement of designated drives
in MSA60 before they actually fail when using HP Systems Insight Manager on HP ProLiant or HP
Integrity servers.
NOTE:
NOTE:
NOTE:NOTE:
Integrated Configuration and Management Tools
Integrated Configuration and Management Tools
Integrated Configuration and Management ToolsIntegrated Configuration and Management Tools
set of Smart Array management and utility software for HP ProLiant Servers. These tools
consistently lower the cost of ownership by reducing training and technical expertise necessary to
install and maintain HP server storage. HP-UX and Open VMS uses HP Integrity ODE for storage
enclosure support.
- The MSA60 has the unique capability of cascading up to 4 - four enclosures behind
- MSA60 supports mixing SAS and SATA drives in the same enclosure, allowing
- Since the MSA60 supports HP Universal SATA drives, your
- Drives installed in a MSA60 and monitored under HP Systems Insight
Some operating systems may not support all of these features.
- The MSA60 utilizes the standard, integrated
DA - 12627 North America — Version 37 — June 8, 2011
Page 6
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.