(formerly known as HP StorageWorks 4400 Enclosure)
The HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures (hereafter referred to as "MSA30 SB or
MSA30 DB") is an Ultra320 SCSI disk drive storage enclosure. These enclosures deliver industry-leading data performance,
availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. The drive carrier
is designed to support the fastest current Ultra320 hard drives on the same SCSI bus. The ease of upgrading the
StorageWorks 4200 or the StorageWorks 4300 Enclosure to the MSA30 proves that HP provides the lowest cost of
ownership. The MSA30 SB and DB enclosures support HP Integrity and HP ProLiant servers in addition to HP 9000 and HP
Alpha Servers. Proving that technology transitions can proceed smoothly without disrupting critical business environments
The MSA30 OVSM HA kit ships with a 60 day trial license of
includes two 72GB 15K rpm Ultra320 hard drives. When configured with a ProLiant server, IT administrators can perform
tasks such as OS Migration, disaster recovery and server consolidation. Administrators can move file servers to new servers
without incurring downtime and while using available bandwidth. This solution allows customers to keep the target and host
units in production mode while allowing the migration of data simultaneously. MSA30 OVSM HA kit will allow the
administrator to manage bandwidth during the migration process to maximize I/O on critical servers during off-peak hours.
NOTE:
For more information on OpenView Storage Mirroring please go to the following link:
The MSA30 design allows for specific configurations tailored to the needs of all HP server customers. The models are
available today:
Model MSA30 SB
Model MSA30 DB
Customer Benefits
Rack-mountable 14 drive enclosure with single bus, redundant power supplies
Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
Higher Performance
Storage Capacity
Upgradeability
Investment Protection
Reduced Spares
Inventory
Ultra320 SCSI transfer rates combined with the highest spindle count
per U of rack space allows the MSA30 to achieve the greatest I/Os per
second.
3U rack form factor allows customer to achieve the maximum storage
capacity per square foot in the data center.
Ultra320 single and dual I/O upgrade modules make upgrading the
StorageWorks 4200/4300 Enclosure to Ultra320 quick and easy.
NOTE:
noted in the product documentation.
With the ability to upgrade, as well as mix and match, existing
Ultra2and/or Ultra3 components with Ultra320, HP makes technology
transitions simple and cost effective, and has simplified the transition to
the next generation SCSI protocol.
Universal drives and drive carriers across HP's entire Ultra2, Ultra3, and
Ultra320 product offering allow the same drives to be used in servers
and external storage.
U320 performance requires a compatible U320 controller. This is
302969-B21
302970-B21
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 1
QuickSpecs
Overview
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
Key Features
NOTE:
All models of the MSA30 (Formerly StorageWorks 4400) Enclosure Family have the
following features:
Ultra320 (LVD) support - Delivering data transfer rates up to 320 MB/s per channel
NOTE:
documentation.
NOTE:
but must be deployed if an upgrade option kit is purchased for a StorageWorks 4200/4300
Enclosure.
U320 performance requires a compatible U320 controller. This is noted in the product
3U rack height.
Supports up to 14 (1-inch) Ultra320 (as well as legacy Ultra3 and Ultra2 drives) Universal
hard disk drives.
Provides storage capacity of up to 4.2TB per enclosure (using 300GB 1-inch disk drives)
Modular design allows the MSA30 to be used in any storage configuration from JBOD (Just
a Bunch of Disks) to Smart Array storage enclosures to external RAID arrays. Up to 14
enclosures can be mounted in one 42U rack for a single rack storage capacity of up to
28.4TB of disk storage (JBOD configuration) or up to 12 enclosures in an EMA16000
(HSG80 configuration) for a single rack storage capacity of 24.4TB.
A common storage platform allows for future storage consolidation to the SAN.
Award-winning innovative SCA (Single Connect Attach) direct connect drive carrier provides better cooling and reliability for 10K and 15K drives.
Hot pluggable disk drives, power supplies, and fans.
Redundant fans, dual power supplies and single or dual bus I/O module options.
Environmental Monitoring Unit (EMU) - Monitors environmental conditions within the
enclosure and components such as the power supplies and fans.
A U320 compatible EMU is required for a U320 I/O module. This is included with a MSA30
Easy removal of parts provides better serviceability. No tools are required!
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 2
QuickSpecs
Product Highlights
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
Upgradeability
Mix and Match
Hot Pluggable
Auto SCSI ID Selection
Upgrading a StorageWorks 4200/4300 Enclosure to a MSA30 is as easy as swapping out the I/O
module and the EMU on the back of the unit. The unit must be powered down to replace the I/O
unit.
NOTE:
documentation. A U320 compatible EMU is also required for upgrades to U320 I/O modules.
All Ultra320, Ultra3, and Ultra2 devices from HP are compatible with one another so customers
can mix and match components in the same storage enclosure or server. When Ultra2, Ultra3,
and Ultra320 devices are found on the same Ultra320 SCSI bus, each device will transfer data at
its individual interface transfer rate up to the transfer rate of the SCSI bus. (Requires an Ultra320
controller for each drive to reach maximum I/Os as listed here.)
NOTE:
inch Universal Ultra2, Utlra3, or Ultra320 disk drives requires the addition of 0.6-inch drive
extenders. For configurations using the PCI-X Dual Channel U320 SCSI HBA, (P/N A7173A),
mixing disks types (U160 and U320) is not supported in the same MSA30 enclosure.
Hot pluggable technology is designed into drives, redundant power supplies and redundant
cooling fans. Hot pluggable components can be replaced without powering down the storage
system or stopping I/O operations. This feature significantly enhances data availability.
SCSI ID is automatically set when a drive is inserted into a drive bay.
U320 performance requires a compatible U320 controller. This is noted in the product
For customers who operate legacy Models 4310R and 4350R enclosures, the use of 1-
LED Indicators
Rack Density
Environment
Monitoring Unit (EMU)
Single Bus I/O Module
Dual Bus I/O Module
Fault Tolerance
LED indicators provide a quick visual assessment of overall system storage status. The MSA30
has three LEDs in the front, for EMU Status, power and fault. LED status and fault indicators for
the fans and power supplies are located in the back of the enclosure.
The MSA30 models have a 3U height.
Each MSA30 model is equipped with a hot-pluggable EMU that constantly monitors the enclosure,
the power supplies, and fans to ensure suggested operating tolerances are maintained.
NOTE:
The single bus I/O module allows one SCSI channel to access all drives in the MSA30.
The dual bus I/O module allows two SCSI channels to access a single MSA30. This allows for
greater fault tolerance (controller duplexing) or provides access from two different servers to two
separate storage areas.
With the dual bus I/O module, redundant power supplies and fans, the MSA30 provides a high
level of system availability. Using an internal or external RAID Array, the MSA30 can be
configured for RAID levels 0, 1, 1+0, 5 and RAID 6 with ADG when using a HP Smart Array RAID
controller.
A U320 compatible EMU is required for a U320 I/O module.
Manageability
Depending on the host controller, the MSA30 is managed by HP Insight Manager or
StorageWorks Command Console.
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 3
QuickSpecs
Product Highlights
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
Compatibility and
Integration Testing
Product Kit Contents
Intensive compatibility and performance testing with HP ProLiant severs, HP Integrity, HP 9000
Servers and Alpha servers ensures the highest level of integration available in the industry on a
HP server. For a complete list of supported HP servers and workstations, please refer to the
QuickSpecs and/or User Guide of the array controller or Host Bus adapter that you are planning to
use. The list of supported array controllers and SCSI adapters is provided under "Related Options,
Controllers".
Model MSA30 SB
Model MSA30 DB
NOTE:
HSG80 controller in a Model 2200 controller enclosure or a host-based adapter on an Alpha
server. See the Related Options section of this document for cable ordering information.
NOTE:
NOTE:
operation.
A different SCSI cable may be required when the MSA30 is intended for connection to an
Power cord for Japan will be included in orders marked for Japan.
To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during
Redundant power supplies, single bus I/O module, 14 drive blanks,
warranty card, mounting hardware, Enclosure 4400 user guide, EMU
booklet, HP SmartStart CD Kit, documentation CD, one 12-ft VHDCI to
VHDCI SCSI cables and two Nema 5-15 to C13 and two IEC320-C14 to
-C13.
Redundant power supplies, dual bus I/O module, 14 drive blanks,
warranty card, mounting hardware, Enclosure 4400 user guide, EMU
booklet, HP SmartStart CD Kit, documentation CD, two 12-ft VHDCI to
VHDCI SCSI cables and two Nema 5-15 to C13 and two IEC320-C14 to
-C13.
Warranty
MSA30: Three-year limited warranty. Limited warranty includes 3 year parts, 0 years labor, 0 years
on-site support.
NOTE:
Hard drive Pre-Failure Warranty: When used with any one of the StorageWorks Smart Array
Family controllers and monitored under HP Insight Manager (v4.20 or later), HP hard drives are
supported by a Pre-Failure (replacement) Warranty.
NOTE:
v4.20 or later, and covers Pentium Pro processors, ECC memory, server hard drives, and external
storage enclosure hard drives (except the 535 MB Fast-SCSI-2 hard drive) using HP IDA, IDA-2,
HP SMART SCSI Array Controllers, HP SMART-2 Array Controllers or HP Smart Array
Controllers. Certain restrictions and exclusions apply.
Certain restrictions and exclusions apply.
Pre-Failure Warranty is available on all HP ProLiant servers using HP Insight Manager
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 4
HP StorageWorks Modular Smart Array 30 Single
QuickSpecs
Service and Support, HP Care Pack, and Warranty Information
Bus or Dual Bus Enclosures
Software Product
Services
Hardware Product
Services
Warranty Upgrade
Options
HP Care Pack
Installation
Standalone telephone support
Rights to new license version
Media and documentation updates
Installation services
On-site maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
RAID setup and performance consulting via statement of work
For additional hardware installation and maintenance information, please refer to the URL listed
below:
Response – Upgrade on-site response from next business day to same day 4 hours
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
Duration – Select duration of coverage for a period of 1, 3, or 5 years
Care Pack services provide a range of life cycle support options that let you choose the service
levels that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24
hours, 7 days call window with options including 4 hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials
and VMware-based IT solutions helping to deliver high level of application availability.
Response times range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution.
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales
offices, resellers or visit our worldwide website at:
NOTE:
For more complete information on HP Services offerings, customers and resellers, please
For additional information on Server Services, Rack and Power Options, please visit:
The information contained herein is subject to change without notice and is provided "as
The warranties for HP products and services are set forth in the express limited warranty
Nothing herein should be construed as constituting an additional warranty. HP shall not be
http://www.hp.com/hps/carepack
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 5
HP StorageWorks Modular Smart Array 30 Single
QuickSpecs
Service and Support, HP Care Pack, and Warranty Information
Bus or Dual Bus Enclosures
HP Care Pack
Information
Flexible Care Packs
Fixed Care Packs
HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific
duration and hours of coverage.
HP Care Pack is not available for less than the product's warranty duration.
HP Care Pack is available for sale anytime during the warranty period for most products, but the
commencement date will be the same as the Warranty Start Date (delivery date to end user
customer). Proof of purchase may be required.
HP Care Pack services are prepaid.
For additional HP Care Pack (hardware & software) information, as well as orderable part
numbers, please refer to the URL
1 Year Next Day HW
1 Year 4h 13x5 HW
1 Year 4h 24x7 HW
1 Year 6h CTR HW
1 Year Support Plus
1 Year Support Plus 24
3 Year Next Day HW
3 Year 4h 13x5 HW
3 Year 4h 24x7 HW
3 Year 6h CTR HW
3 Year Support Plus
3 Year Support Plus 24
Installation
3 Year NBD 9x5 (Electronic)
3 Year 4H 13x5 (Electronic)
3 Year 4H 24x7 (Electronic)
3 Year 6H CTR (Electronic)
1 Year NBD 9x5 (Electronic)
1 Year 4H 13x5 (Electronic)
1 Year 4H 24x7 (Electronic)
1 Year 6H CTR (Electronic)
Installation (Electronic)
http://www.hp.com/hps/carepack/
HA101A1-7GT
HA103A1-7GT
HA104A1-7GT
HA105A1-7GT
HA109A1-7GT
HA110A1-7GT
HA101A3-7GT
HA103A3-7GT
HA104A3-7GT
HA105A3-7GT
HA109A3-7GT
HA110A3-7GT
HA113A1-564
U8128E
U8129E
U8130E
U8131E
U8151E
U8152E
U8153E
U8154E
U8132E
Components
The following brick level options/components do not have individual HP Care Pack Services.
These items will be included in product HP Care Pack Services into which they are installed.
Disk Drives
Bus Converters
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Tape Drives
Backplane RAID
Controllers
CD/DVD ROM
Power Supplies
SCSI Hubs in
SBBs
Cabling
Adapters
Fans
Page 6
QuickSpecs
Configuration Information
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
NOTE:
MSA30
Ultra320 Single Bus
Upgrade I/O Module
Ultra320 Dual Bus
Upgrade I/O Module
Redundant Power
Supply, 499 watts
Controllers & Adapters
Supported
Some of the options listed below may be discontinued.
Shipping Dimensions
34.38 x 34.375 x 12 in (87.33 x 87.313 x 30.48 cm) (SB)
34.38 x 34.375 x 12 in (87.33 x 87.313 x 30.48 cm) (DB)
19.63 x 17.25 x 3.75 in (49.86 x 43.81 x 9.53 cm)
12.75 x 8 x 3.75 in (32.13 x 20.16 x 9.45 cm)
12.75 x 8 x 3.75 in (32.13 x 20.16 x 9.45 cm)
Smart Array 6404/256 Controller
Smart Array 6402/128 Controller
Smart Array 5304/256 Controller
Smart Array 642 Controller
64-Bit/66Mhz Dual Channel Wide Ultra3 SCSI Adapter, Alternative OS
1 channel Ultra2 (LVD) Adapter (Alpha Server systems)
PCI-X TO SCSI UWD (FAST20 Differential) Adapter
NOTE:
Requires: 3X-DWZCV-BA or 3X-DWZCV-CA HVD-to-LVD converter
PCI 2 Port 100Base-T & 2 Port Ultra2 SCSI
OS Support: HP-UX 11i v1; HP-UX 11i v2.
Ultra160 SCSI Adapter
OS Support: Windows 2003 server on Integrity servers
2 port Ultra160 SCSI HBA
OS Support: Windows 2003 server on Integrity servers
Part Number
302969-B21
302970-B21
287484-B21
287483-B21
338296-B21
Part Number
273914-B21
(A9891A)
273915-B21
(A9890A)
283551-B21
(A9826A)
291967-B21
284688-B21
3X-KZPCA-AA
3X-KZPBA-CC
3X-KZPCA-AA
3X-KZPEA-DB
DS-KZPCC-AC
DS-KZPCC-CE
3X-KZPDC-BE
3X-KZPDC-DF
3X-DEPVZ-AA
A7173A
A6829A
A6828A
A5838A
A7059A
A7060A
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 7
QuickSpecs
Configuration Information
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
Power Options
HP Rack 5000 Series
(Metallic Carbonite)
PCI-X 2-Port U320 SCSI and 2-Port Gigabit Ethernet Combination Card
OS Support: HP-UX 11.11, 11.23PI, Linux (RH AS3, RH AS4, SLES9) on
Integrity servers, Windows 2003 server on Integrity servers
NOTE:
controller and server compatibility.
HP 9000 and HP Integrity Server-Storage Support Matrices:
B22 (shock pallet) used to ship racks with equipment installed (by custom
systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of
empty racks.
NOTE:
equipment installed.
NOTE:
Technical Specifications such as height, width, depth, weight, and color:
Each Modular Storage Cabinet (42U, 41U, 36U, and 22U) comes with
.
xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. xxxxxx-
It is mandatory to use a shock pallet in order to ship racks with
Please see the Rack 10000 QuickSpecs for additional part number and
For additional information regarding Rack Cabinets, please see the
http://www.hp.com/go/rackandpower
.
180312-B22
180313-B21
180314-B22
180315-B21
180316-B22
180317-B21
180318-B22
Legacy Racks
Supported
Rack 7142
Rack 9142
Rack 9136
Rack 9122
NOTE:
maximum number of Model 4314R or Model 4354R enclosures in one of the
supported HP racks. Please refer to
http://h18006.www1.hp.com/storage/index.html
Certain power support and cooling restrictions apply when housing a
for more information.
165753-001
120663-B21
120664-B21
120665-B21
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 9
QuickSpecs
Configuration Information
Universal SCSI Drives
Ultra 320 Drives
HP 300GB U320 15K Universal HDD
HP 300GB U320 10K Universal HDD
HP 146GB U320 10K Universal HDD
HP 72GB U320 10K Universal HDD
HP 146GB U320 15K Universal HDD
HP 72GB U320 15K Universal HDD
HP 36GB U320 15K Universal HDD
0.6-inch (1.52 cm) Drive Extenders (package of 4)
1. Ultra 2 and Ultra3 drives are also supported in 4300 configurations.
2. For pre-existing 10-bay solutions, drive height extenders are attached to 1 in
drives for use in 1.6 in drive bay.
NOTE:
compatibility information (
hard drives in unsupported configurations will result in voiding the warranty and
could result in damage to the drive and/or loss of data.
Go to the
HP StorageWorks Modular Smart Array 30 Single
HP SCSI Hard Drive Compatibility
http://www.hp.com/products/harddiskdrives
Bus or Dual Bus Enclosures
411089-B22
350964-B22
286716-B22
286714-B22
347708-B22
286778-B22
286776-B22
148649-B21
table for complete drive
). Using
SCSI Cable Options
Cables for use with Smart Array controllers
12 ft VHDCI to 68-pin SCSI Cable
24-ft VHDCI to VHDCI SCSI Cable
39-ft VHDCI to VHDCI SCSI Cable
Cables for use with the KZPCA-AA host bus adapter
1M SCSI 68HD Cable
2M SCSI 68HD Cable
3M SCSI 68HD Cable
5M SCSI 68HD Cable
10M SCSI 68HD Cable
341177-B21
164604-B21
150214-B21
BN38C-01
BN38C-02
BN38C-03
BN38C-05
BN38C-10
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 10
QuickSpecs
Technical Specifications
HP StorageWorks Modular Smart Array 30 Single
Bus or Dual Bus Enclosures
Protocol Support
O/S Support
Dimensions
Shipping Dimensions
(HxWxD)
Weight
LED Indicators
panel)
Drive LED Indicators
(on drive trays)
Enclosure LED
Indicators
Input Requirements
Relative Humidity
condensing)
I/O Module Connector
Power
BTU
(220 volts)
Temperature Range
(HxWxD)
(on front
(back of unit)
(non-
Wide Ultra320 (LVD)
Wide Ultra3 (LVD)
Wide Ultra2 (LVD)
Defined by specific HP array controller or SCSI adapter used; please refer to the QuickSpecs
and/or User Guide of the specific array controller or SCSI adapter
Rack
Rack
Rack
EMU Status LED (left)
Enclosure Power LED (middle)
Fault LED (right)
Drive LED (top)
On Line LED (middle)
Drive Failure LED (bottom)
I/O Module (top)
EMU (middle)
Power supplies (bottom)
Nominal Line Voltage
Range Line Voltage
Line Frequency
Typical Input Current
Operating
Shipping
Very High Density Cable Interconnect (VHDCI)
377 Watts per supply (load)
Single power supply 14
drives
Single power supply 5
drives
Single power supply 1
drive
Dual power supply 14
drives
Dual power supply 5
drives
Dual power supply 1
drive
Operating
Shipping
NOTE:
operation.
To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during
5.2 x 19 x 20.5 in (13.1 x 47.88 x 51.66 cm)
34.25 x 14.5 x 31.25 in (86.31 x 36.54 x 78.75 cm)
68 lb (30.9 kg)
110 to 240 V AC
90 to 264 V AC
47 to 63 Hz
2.3A at 120 V AC
10% to 90%
5% to 90%
1164 BTUs/hour
536 BTUs/hour
273 BTUs/hour
1232 BTUs/hour
625 BTUs/hour
352 BTUs/hour
50° to 94° F (10° to 35° C°)
-40° to 151° F (-40° to 66° C)
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007
Page 12