Honeywell XNX User Manual

2018 Product Guide Americas
Industrial Fixed Gas and Flame Detection
Issue: 1V0
Page1.3
2.43.104.145.226.247.258.299.3210.3411.3512.3813.3914.4015.4616.5017.5618.5819.
59
20.6021.6522.6823.7124.7325.7426.7927.
80
28.8129.8430.8531.
107
32.
113
33.
116
34.
118
35.
120
36.
123
37.
124
38.
125
39.
131
40.
136
41.
139
140
141
142
144
42.
146
Honeywell Analytics Service..........................................................................................................
Accessories....................................................................................................................................
Horns & Strobes............................................................................................................................
PowerSupplies & Additional Accessories......................................................................................
Calibration Reference Guide.........................................................................................................
Calibration Kits, Components and Gas..........................................................................................
Satellite XT Gas Detector Transmitter...........................................................................................
Midas® Extractive Gas Detector....................................................................................................
SPM Flex........................................................................................................................................
Calibration Gases..................................................................................... .....................................
HA20 & HA40 Digital Gas Controllers............................................................................................
HA71 Digital Gas Controller...........................................................................................................
HA72 Digital Gas Controller...........................................................................................................
System 57 Control for Fire and Gas Detection..............................................................................
Unipoint DIN Rail Mounted Controller..........................................................................................
FSL100 Flame Detector.................................................................................................................
RAEGuard 2 PID.............................................................................................................................
Touchpoint Pro Digital Gas Controller...........................................................................................
Touchpoint Plus Digital Gas Controller..........................................................................................
FS7 Flame Detector.......................................................................................................................
SS4-A2, AS, & AUV Series..............................................................................................................
SS2-AM Series...............................................................................................................................
FS10 Fire Detection Systems.........................................................................................................
Searchline Excel XD.......................................................................................................................
Model FS24X.................................................................................................................................
Model FS20X.................................................................................................................................
Series 3000 MkII and MkIII............................................................................ ................................
Searchpoint Optima Plus...............................................................................................................
Searchpoint Optima Plus Calibrations...........................................................................................
Searchline Excel.............................................................................................................................
OELD Smart Junction Box..............................................................................................................
705 Combustible Gas Detector.....................................................................................................
Sensepoint XCD RTD.....................................................................................................................
Sensepoint Sensors.................................................................................... ...................................
Sensepoint with Junction Box.......................................................................................................
Safe Area XCD...............................................................................................................................
XNX™ Universal Transmitter.........................................................................................................
Sensepoint XCD.............................................................................................................................
Sensepoint XCD RFD......................................................................................................................

Table Of Contents

Explosion-Proof Transmitters: Quick Reference Chart..................................................................
Sensepoint XRL........................................................................................ ......................................
Infrared Transmitters: Quick Reference Chart..............................................................................
FSX Detectors: Quick Reference Chart..........................................................................................
FSX Detectors Applications Chart..................................................................................................
SS Series Flame Detectors: Quick Reference Chart........................................................................
Gas Detection Controllers: Quick Reference Chart........................................................................
Table of Contents
Safe Area and Intrinsically Safe Transmitters: Quick Reference Chart..........................................
Quick Reference Chart
Optima Excel Local Display
(OELD)
passthrough
Sensepoint XCD
YDCAL, SS
4-20 mA; Modbus
N
Sensepoint XCD RTD
YDCAL, SS
4-20 mA; Modbus
N
Sensepoint XCD RFD
YDCAL, SS
4-20 mA; Modbus
N
Sensepoint XRL
N (Light Ring Only)
NoAL4-20 mA; Modbus
Y
Series 3000 MKII/MKIII
YNoAL, SS
4-20 mA
N
705 Sensor
YNoSS
4-20 mA
N
Optima Plus
N (Y w/ XNX)
NoSS4-20 mA; HART
N (Y w/ OELD)
Toxic Gas Sensor
XNX™
XCD
XCD RTD
XRL
S3000
Ammonia (NH
)XXX*X
Arsine (AsH
)
Boron Trichloride (BCl
)
Bromine (Br
)
Carbon Monoxide (CO)
XXXXX
Carbon Dioxide (CO
)XXX*Chlorine (Cl
2
)XXX*X
Chlorine Dioxide (ClO
2
)XX
Diborane (B
2H6
)
Dichlorosilane (H
2
SiCl2)
Ethylene Oxide (EtO)
X
X
Fluorine (F
2
)
Germane (GeH
4
)
Hydrogen (H
2
)XXXXXHydrogen Bromide (HBr)
Hydrogen Chloride (HCl)
XXHydrogen Cyanide (HCN)
X
Hydrogen Fluoride (HF)
XXHydrogen Sulfide (H
2
S)XXXXXNitric Oxide (NO)
XXX
Nitrogen Dioxide (NO
2
)XXXXXOxygen (O
2
)XXXXXOzone (O
3
)X*Phosphine (PH
3
)XX
Silane (SiH
4
)
Sulfur Dioxide (SO
2
)XXX*X
*Will be added in 2018
LEL Sensor
XNX™
XCD/XRL¹
XCD RFD
705
OELD/Optima
Non-specific combustible
XXXXX
Butane (C
4H10
)XXXXXButyl Acetate (C
6H12O2
)XXXXXEthylene (C
2H4
)XXXXXHexane (C
6H14
)XXXXXHydrogen (H
2
)XXXXXMethane (CH
4
)XXXX
X
Pentane (C
5H12
)XXXXXPropane (C
3H8
)XXXXXToluene (C
7H8
)XXXX
X
1. Explosion-Proof Transmitters
3
Product Display Relays Material Communication Bluetooth®
4-20 mA; HART;
XNX™ Universal Transmitter N
Y DC AL, SS
Modbus; Foundation
Y No AL, SS
3
3
3
2
2
4-20 mA; HART
Y
Note:
1. XRL calibrated to Methane. Please contact HA customer service for other flammable gasses.
in ppm
- Large, backlit, easy-to-view LCD display offers multiSensory indicators
- One-man operation
- Non-intrusive, one-man operation
- Plug-in Sensor replacement
- Quick calibration with auto-inhibit
- All necessary accessories included
2
. XNX™ Universal Transmitter
4
C2H4, C3H8, C4H10, C5H12, C6H12O2, C6H14, C7H8, CH4, Cl2, ClO2,
CO, CO2, H2, H2S, HCl, HF, LEL, NH3, NO, NO2, O2, PH3, SO2
The XNX™ Universal Transmitter, now with HART EDDL/DTM, marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of Sensors on a common platform and offers a modular choice of inputs and outputs. XNX is designed for flexible integration, simple installation, user-friendly operation and straight-forward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. The introduction of our HART Enhanced Device Descriptor Language (EDDL) & Device Type Manager (DTM) software provides users with an at-a-glance indication of the health of their gas detectors in the field.
High performance Easy to Install
- Flammable gas detection 0 to 100% LFL/LEL - 3 or 4 wire operation, source, sink or isolated
- Point IR with heated optics provides immunity to poisoning and no hidden faults
- Open-path IR flammable gas detection in LEL­m measurement
- Electrochemical cell offers toxic gas detection
- IR cell provides CO2 and combustible gas monitoring
- Robust and reliable operation in explosive areas and harsh environments
Cost Effective
- Minimal training required - Self-test and fault indication features
- Simple plug-in Sensors and replaceable cells
- NEMA 4X IP66 rated for rugged indoor/outdoor use
- Five conduit entries for ease of installation
Easy to Use
(visual icons, colored buttons, text, etc.) to display gas and Sensor readings
- User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
Flexible Operation Certifications
- 3 Versions - supports (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
- Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
- 4-20 mA with HART® as standard - Class I Zone 1 Group IIC, Class II, Zone 20 & 21
- HART Enhanced Device Description Language (EDDL) & Device Type Manager (DTM) software*
- Multiple communications optionsinclude up to 3 relays, Modbus® and FOUNDATION® H1 Fieldbus
- Optional local IS port for handheld HART configurator
- UL, CSA, FM, DEMKO, DEKRA, InMetro, TUV, ABS, HART, IELDBus Foundation, GOST and KTL approved for Hazardous Locations, Gas Performance and SIL 2 ratings among others
- Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups F and G; Hazardous Locations
- Intrinsically safe barriers for HART and EC connections
- For additional information on certifications and approvals contact Honeywell Analytics
AFH
NNN
2
. XNX™ Universal Transmitter
> MPD Sensor
The MPD (Multi-Purpose Detector), a low-cost Infrared or Catalytic bead sensing cell for monitoring flammable industrial gases in hazardous areas. Through the XNX, the MPD can
5
2.1 XNX Order Number and Pricing Configurator
The XNX™ Universal Transmitter is designed for flexible integration, simple installation, user-friendly operation and straight-forward maintenance. The XNX supports a wide range of Sensors on a common platform and offers a modular choice of inputs and outputs.
> Sensor Personality >
Electrochemical E N None
Infrared (Optima/Excel) or 4-20 mA input (Sensepoint, etc.)
milliVolt V M Modbus
I R Relay
> Enclosure Material
Aluminum A
Painted Stainless Steel S N
> Agency Approval & Thread Type
ATEX/IEC M25 AM NNN
UL/CSA 3/4” NPT UT
INMETRO 3/4” NPT BT CB1
> XNX Base Unit IF1
XNX Base Unit XNX IV1
Order number:
XNX
UT
Interface Options
F
E
Foundation Fieldbus
> Local HART
H
and Range
IC1
None
Local HART® Port
None*
*for milliVolt versions only (must
select 'V' sensor personality)
Catalytic Bead %LEL
IR %LEL Flammable
IR CH4 0-5% Vol/100% LEL
IR CO2 0-5% Vol
*Always used for “I” and “E” Sensor personality.
For example, the order number for an XNX (XNX-) configured for UL/CSA Approval and 3/4" NPT thread type (UT), Aluminum enclosure (A), Electrochemical personality (E-), Foundation Fieldbus interface (F), and Local HART (H) would be XNX-UTAE-FHNNN.
sensor
Multi-Purpose Detector (MPD)
support a variety of communications protocol used in industrial communications systems.
> Agency Approval > Port Threads
ATEX A T UL/CSA U M
INMETRO B >MPD Base Unit
MPD Base Unit MPD
Order number:
For example, the order number for an MPD (MPD-) configured for UL/CSA Approval (U), 3/4” NPT thread type (T), and Catalytic Bead %LEL Sensor (CB1) would be MPD-
UTCB1.
MPD U
T
> Sensor
CB1 Catalytic Bead %LEL
CB1
3/4 NPT M25
IF1 IR %LEL Flammable IV1 IR CH4 0-5% Vol IC1 IR CO2 0-5% Vol
XNXXSO1SS
Oxygen (O
) 0-25% v/v
XNXXSC1SS
Carbon monoxide (CO) 0-300 ppm (100 to 500 ppm max scale for XNX, 100 ppm)
XNXXSC1FM
Carbon monoxide (CO) 100-1000 ppm (FM approved)
XNXXSH3SS
Hydrogen sulfide (H
2
S) 0-15 ppm
XNXXSH1FM
Hydrogen sulfide (H
2
S) 10-50 ppm (FM approved)
XNXXSH1SS
Hydrogen sulfide (H
2
S) 0-15.0 ppm (10.0 to 50.0 ppm, 1 ppm)
XNXXSH2SS
Hydrogen sulfide (H
2
S) 0-100 ppm (50 to 500 ppm, 10 ppm)
XNXXSL1SS
Chlorine (Cl
2
) 0-5.0 ppm (5.0 to 20.0 ppm, 5.0 ppm)
XNXXSL2SS
Chlorine (Cl
2
) 0-5.00 ppm fixed range
XNXXSS1SS
Sulfur dioxide (SO
2
) 0-15.0 ppm (5.0 to 20.0 ppm, 5.0 ppm)
XNXXSS2SS
Sulfur dioxide (SO
2
) 0-50.0 ppm (20.0 to 50 ppm, 10 ppm)
XNXXSX1SS
Chlorine dioxide (ClO
2
) 0-1.00 ppm
XNXXSM1SS
Nitric oxide (NO) 0-100 ppm
XNXXSN1SS
Nitrogen dioxide (NO
2
) 0-10.0 ppm (5.0 to 50.0 ppm, 5.0 ppm)
XNXXSG1SS
Hydrogen (H
2
) 0-1000 ppm
XNXXSG2SS
Hydrogen (H
2
) 0-10,000 ppm
XNXXSF1SS
Hydrogen fluoride (HF) 0-12.0 ppm
XNXXSA1SS
Ammonia (NH
3
) 0-200 ppm (50 to 200 ppm, 50 ppm)
XNXXSA2SS
Ammonia (NH
3
) 0-1000 ppm (200 to 1000 ppm, 50 ppm)
XNXXSP1SS
Phosphine (PH
3
) 0-1.2 ppm
XNXXSR1SS
Hydrogen chloride (HCl) 0-10 ppm (10 to 20 ppm, 1 ppm)
XNXXSY1SS
XNX Sensor hydrogen cyanide (HCN) 0-30 ppm (Fixed Scale)
XNXXSE1SS
XNX Sensor ethylene oxide (EtO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm)
MPD-UTCB1
XNX MPD UL/CSA catalytic bead Sensor 0-100% LEL
MPD-UTIF1
XNX MPD UL IR cartridge 0-100% LEL propane (C
3H8
) (flammables)
MPD-UTIV1
XNX MPD UL IR cartridge 0-100% LEL methane (CH4)
MPD-UTIC1
XNX MPD UL/cUL IR cartridge carbon dioxide (CO
2
) 0-5% VV
MPD-AMCB1
XNX MPD ATEX/IECEx catalytic bead Sensor 0-100% LEL
MPD-AMIF1
XNX MPD ATEX/IECEx IR cartridge 0-100% LEL propane (flammables)
MPD-AMIV1
XNX MPD ATEX/IECEx IR cartridge 0-100% LEL methane
MPD-AMIC1
XNX MPD ATEX/IECEx IR cartridge CO
2
0-5% VV
2
. XNX™ Universal Transmitter
6
2.2 Toxic and Oxygen Smart Sensors
A wide range of toxic and oxygen sensors, featuring patented Surecell™ and Reflex technology, are available for use with the XNX™ Universal Transmitter. Featuring a field replaceable sensor, these sensors are shipped pre-calibrated to the range listed below.
XNX™ Sensors
t Number Description
Par
XNXXSO1FM Oxygen (O2) 23% v/v fixed (FM approved)
2
MPD: Multi-Purpose Detector (mV) - UL/CSA (3/4 in. NPT)
Part Number Description
Note: When remote Mounting the MPD, Ferrite Bead (0060-1051) is required.
MPD: Multi-Purpose Detector (mV) - ATEX/IECEX (M25) Part Number Description
Part Number
Description
S3KDMK
Duct mount Kit
Part Number
Description
Note: S3KDMK and 1226A0382 should be order together
1226A0411
Calibration gas flow adaptor (for use with MPD)
02000-A-1645
Calibration gas flow adaptor (for use with Sensepoint Sensors)
00780-A-0035
Calibration gas flow adaptor (for use with 705 Sensors)
02000-A-1640
Weatherproof cap (for use with MPD and Sensepoint Sensors)
02000-A-1635
Weatherproof cap (for use with 705 Sensors)
Part Number
Description
Note: must be used with SPXCDWP weather protection housing.
Part Number
Description
S3KO1SS
Oxygen (O
2
) 0-25% v/v
S3KC1SS
Carbon monoxide (CO) 0-300 ppm (100 to 999 ppm, 100 ppm)
S3KH1SS
Hydrogen sulfide (H
2
S) 0-15 ppm (10 to 50 ppm, 1 ppm)
S3KH2SS
Hydrogen sulfide (H
2
S) 0-100 ppm (50 to 500 ppm, 10 ppm)
S3KL1SS
Chlorine (Cl
2
) 0-5.0 ppm (5.0 to 20.0 ppm, 5.0 ppm)
S3KS1SS
S3KX1SS
Chlorine dioxide (ClO
2
) 0-1.00 ppm
S3KM1SS
Nitric oxide (NO) 0-100 ppm
S3KN1SS
Nitrogen dioxide (NO
2
) 0-10.0 ppm (5.0 to 50.0 ppm, 5.0 ppm)
S3KG1SS
Hydrogen (H
2
) 0-1000 ppm
2
. XNX™ Universal Transmitter
7
2.3 XNX™ Accessories
XNX™ Accessories: For Use With All Versions of XNX
94000-A-1006 XNX Sunshade w/ Optima cut out 1226A0358 Pipe mount Kit 1226A0355 Ceiling mount bracket
1226A0354 Remote gassing Kit 2441-0022 UL/CSA aluminum 6 wire junction box assembly
2430-0021 UL/CSA aluminum 3 wire junction box assembly 00780-A-0100 ATEX/IECEx junction box assembly
XNX™ Accessories: For Use With MPD Catalytic and IR Cartridge Sensors
1226A0382 MPD interface adaptor (required with duct mount Kit for MPD)
02000-A-1642 Collecting cone (for use with MPD, Sensepoint and 705 Sensors) 0060-1051 Ferrite bead (for use with mV Sensors)
XNX™ Accessories: For Use With Toxic and Oxygen Sensors
S3KRMK Remote EC Mounting Kit (50 Feet) S3KRMK45 Remote EC Mounting Kit (150 Feet) S3KRMK75 Remote EC Mounting Kit (250 Feet) SPXCDWP Enclosed weather protection housing with bump port
S3KWP Weatherproof housing (for use with corrosives) S3KCAL Calibration gas flow adaptor (for use with EC Sensors) SPXCDCC Collecting cone for use with lighter than air gases
Replacement Toxic and Oxygen Sensor Cartridges
Sulfur dioxide (SO2) 0-15.0 ppm (5.0 to 20.0 ppm, 5 ppm); 0-50.0 ppm (20.0 to 50.0 ppm, 10 ppm)
Part Number
Description
S3KG2SS
Hydrogen (H
2
) 0-10,000 ppm
S3KA1SS
Ammonia (NH
3
) 0-200 ppm (50 to 200 ppm, 50 ppm)
S3KA2SS
Ammonia (NH
3
) 0-1000 ppm (200 to 1000 ppm, 50 ppm)
S3KP1SS
Phosphine (PH
3
) 0-1.2 ppm
S3KR1SS
Hydrogen chloride (HCl) 0-10 ppm (10 to 20 ppm, 1 ppm)
XNXE1SS
Ethylene Oxide (EtO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm)
Part Number
Description
1226A0359
Replacement catalytic bead Sensor 0-100% LEL
1226-0300
Replacement IR cartridge 0-100% LEL propane (C
3H8
) (flammables)
1226-0299
Replacement IR cartridge 0-100% LEL methane (CH
4
)
1226-0301
Replacement IR cartridge carbon dioxide (CO
2
) 0-5% VV
Part Number
Description
1226-0257
M25 stopping plug with protective cap and O-ring (Stainless Steel)
1226-0258
3/4 in. NPT stopping plug with protective cap and O-ring (Stainless Steel)
0235-0238
Replacement O-ring for XNX front cover
1226A0302
Terminal block assembly 6-pin for XNX EC
1226A0304
Terminal block assembly 9-pin for XNX mV
1226A0305
IR terminal block assembly Kit includes: 9-pin and 2 pin blocks
1226A0306
Relay terminal block assembly Kit includes: 9-pin and 2-pin blocks
1226A0307
Terminal block assembly 10-pin for XNX Modbus
1226-0254
Magnetic wand/screwdriver
1226-0408
Small screwdriver (for use with relay board and IR personality board)
1226-0350
Sensor Retainer, includes set screw. (SS cover for EC sensor.)
1226A0303
Terminal block assembly 6-pin XNX Foundation Fieldbus
Part Number
Description
1226-9002
XNX POD IR personality with relay option
1226-9003
XNX POD IR personality with Modbus option
1226-9004
XNX POD IR personality with FFB option
1226-9005
XNX POD ECC personality
1226-9006
XNX POD ECC personality with relay option
1226-9007
XNX POD ECC personality with Modbus option
1226-9008
XNX POD ECC personality with FFB option
1226-9009
XNX POD MV personality
1226-9010
XNX POD MV personality with relay option
1226-9011
XNX POD MV personality with Modbus option
1226-9012
XNX POD MV personality with FFB option
2
. XNX™ Universal Transmitter
8
Replacement Toxic and Oxygen Sensor Cartridges continued
Replaceable MPD Catalytic and IR Cartridges
XNX™ Spares
XNX™ PODs*
1226-9001 XNX POD IR personality
*Terminal blocks are NOT included with PODs
2
. XNX™ Universal Transmitter
9
2.4 Calibration Kits and Components
XNX™ Calibrarion Kits and Components Product Contains Part Number
Tubing, flow adaptor, regulator, carrying case XNX Toxic Kit 998100004, S3KCAL,
ZCALREG1 (.3 LPM),
100003
998
Tubing, flow adaptor, regulator, carrying case XNX Toxic Kit (HCN, Cl2,
HF, NH3, and HCl)
XNXTOXKit
XNXTOXKIT2
Tubing, flow adaptor, regulator, carrying case XNX Combustibles Kit 106459, 1226A0411, N600
1001 33 (.5 LPM), 998100003
XNX EC barrier service kit 1226A0057 1226A0368
3/4 inch EC potted assembly 1226A0369
Flow housing XNX S3K EC cell, teflon SVIP3766-007
Flow housing XNX S3K MPD, IR, cat bead SVIP3766-008
XNXCOMBKit

3. Sensepoint XRL

Sensepoint XRL is fully configurable via Bluetooth on your Android Smart Device.
Part Number
Description
SPLIC1BAXYNUZZ
SPXRL-BT-cULus-CO 300ppm-mA-YEL
Part Number
Description
SPLIC1BAXCNUZZ
SPXRL-BT-cULus-CO 300ppm-mA-CHR
10
Sensepoint XRL is a fixed point gas leak detector that is designed to meet the needs of
ndustrial applications. With over 50 years experience in gas leak detection, Honeywell
i offers a flexible range of highly-reliable sensing devices to meet those needs.
• Quick installation
• Rapid configuration
• Simple to operate
• Straightforward to maintain
Honeywell innovation enables customers to pair the gas detector with their mobile phone, and then use an app to perform many tasks related to installation, commissioning and maintenance.
3.1 Instruments
Each Sensepoint XRL is supplied with registration sheet, 3/4 NPT or M20 metal stopping plug, Hex Allen key and quick start guide.
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, cULus
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, cULus
SPLIO1BAXYNUZZ
SPLIH1BAXYNUZZ SPLIH2BAXYNUZZ SPLIG1BAXYNUZZ SPLIN1BAXYNUZZ SPLIF6BAXYNUZZ
SPXRL-BT-cULus-O2 25.0%VOL-mA-YEL
SPXRL-BT-cULus-H2S 50ppm-mA-YEL SPXRL-BT-cULus-H2S 100ppm-mA-YEL SPXRL-BT-cULus-H2 1000ppm-mA-YEL SPXRL-BT-cULus-NO2 20.0ppm-mA-YEL (Available Q4 2017) S
PXRL-BT-cULus-CH4 100%LEL-mA-YEL
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, cULus
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, cULus
SPLIO1BAXCNUZZ
SPLIH1BAXCNUZZ SPLIH2BAXCNUZZ SPLIG1BAXCNUZZ SPLIN1BAXCNUZZ SPLIF6BAXCNUZZ
SPXRL-BT-cULus-O2 25.0%VOL-mA-CHR
SPXRL-BT-cULus-H2S 50ppm-mA-CHR SPXRL-BT-cULus-H2S 100ppm-mA-CHR SPXRL-BT-cULus-H2 1000ppm-mA-CHR SPXRL-BT-cULus-NO2 20.0ppm-mA-CHR (Available Q4 2017) S
PXRL-BT-cULus-CH4 100%LEL-mA-CHR
3. Sensepoint XRL
Part Number
Description
SPLIC1BMXYNUZZ
SPXRL-BT-cULus-CO 300ppm-Modbus-YEL
Part Number
Description
SPLIC1BMXCNUZZ
SPXRL-BT-cULus-CO 300ppm-Modbus-CHR
Part Number
Description
SPLIC1BAXYMAZZ
SPXRL-BT-ATEX-CO 300ppm-mA-YEL
Part Number
Description
SPLIC1BAXCMAZZ
SPXRL-BT-ATEX-CO 300ppm-mA-CHR
2
11
Sensepoint XRL, Bluetooth, Yellow, Modbus, cULus
Sensepoint XRL, Bluetooth, Yellow, Modbus, cULus
SPLIO1BMXYNUZZ
SPLIH1BMXYNUZZ SPLIH2BMXYNUZZ SPLIG1BMXYNUZZ SPLIN1BMXYNUZZ SPLIF6BMXYNUZZ
SPXRL-BT-cULus-O2 25.0%VOL-Modbus-YEL
SPXRL-BT-cULus-H2S 50ppm-Modbus-YEL SPXRL-BT-cULus-H2S 100ppm-Modbus-YEL S
PXRL-BT-cULus-H2 1000ppm-Modbus-YEL SPXRL-BT-cULus-NO2 20.0ppm-Modbus-YEL (Available Q4 2017) SPXRL-BT-cULus-CH4 100%LEL-Modbus-YEL
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, cULus
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, cULus
SPLIO1BMXCNUZZ
SPLIH1BMXCNUZZ SPLIH2BMXCNUZZ SPLIG1BMXCNUZZ SPLIN1BMXCNUZZ SPLIF6BMXCNUZZ
SPXRL-BT-cULus-O2 25.0%VOL-Modbus-CHR
SPXRL-BT-cULus-H2S 50ppm-Modbus-CHR SPXRL-BT-cULus-H2S 100ppm-Modbus-CHR SPXRL-BT-cULus-H2 1000ppm-Modbus-CHR S
PXRL-BT-cULus-NO2 20.0ppm-Modbus-CHR (Available Q4 2017) SPXRL-BT-cULus-CH4 100%LEL-Modbus-CHR
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, ATEX/IECEx
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, ATEX/IECEx
SPLIO1BAXYMAZZ
SPLIH1BAXYMAZZ SPLIH2BAXYMAZZ
SPLIG1BAXYMAZZ SPLIN1BAXYMAZZ SPLIF6BAXYMAZZ SPXRL-BT-ATEX-CH4 100%LEL-mA-YEL
SPXRL-BT-ATEX-O2 25.0%VOL-mA-YEL
SPXRL-BT-ATEX-H2S 50ppm-mA-YEL SPXRL-BT-ATEX-H2S 100ppm-mA-YEL SPXRL-BT-ATEX-H2 1000ppm-mA-YEL S
PXRL-BT-ATEX-NO2 20.0ppm-mA-YEL (Available Q4 2017)
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, ATEX/IECEx
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, ATEX/IECEx
SPLIO1BAXCMAZZ SPXRL-BT-ATEX-O2 25.0%VOL-mA-CHR
SPLIH1BAXCMAZZ SPXRL-BT-ATEX-H2S 50ppm-mA-CHR SPLIH2BAXCMAZZ SPXRL-BT-ATEX-H2S 100ppm-mA-CHR SPLIG1BAXCMAZZ SPXRL-BT-ATEX-H2 1000ppm-mA-CHR SPLIN1BAXCMAZZ SPXRL-BT-ATEX-NO SPLIF6BAXCMAZZ SPXRL-BT-ATEX-CH4 100%LEL-mA-CHR
20.0ppm-mA-CHR (Available Q4 2017)
3. Sensepoint XRL
Part Number
Description
SPLIC1BMXYMAZZ
SPXRL-BT-ATEX-CO 300ppm-Modbus-YEL
Part Number
Description
SPLIC1BMXCMAZZ
SPXRL-BT-ATEX-CO 300ppm-Modbus-CHR
3.2 Accessories, Consumables & Spares
Part Number
Description
SPXRLCAL
SPXRL-Calibration Cap
SPXRLFLW
SPXRL-Flow Housing
SPXRLDMK
SPXRL-Duct Mount Kit
2308B0923
Pipe Mounting Bracket Kit
SPXCDWP
Sensepoint XRL optional weather protection
SPXCDCC
Collecting cone for use with lighter than air gases, must be used with SPXCDWP
12
Sensepoint XRL, Bluetooth, Yellow, Modbus, ATEX/IECEx
Sensepoint XRL, Bluetooth, Yellow, Modbus, ATEX/IECEx
SPLIO1BMXYMAZZ
SPLIH1BMXYMAZZ SPLIH2BMXYMAZZ SPLIG1BMXYMAZZ SPLIN1BMXYMAZZ SPLIF6BMXYMAZZ
SPXRL-BT-ATEX-O2 25.0%VOL-Modbus-YEL
SPXRL-BT-ATEX-H2S 50ppm-Modbus-YEL SPXRL-BT-ATEX-H2S 100ppm-Modbus-YEL S
PXRL-BT-ATEX-H2 1000ppm-Modbus-YEL SPXRL-BT-ATEX-NO2 20.0ppm-Modbus-YEL (Available Q4 2017) SPXRL-BT-ATEX-CH4 100%LEL-Modbus-YEL
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, ATEX/IECEx
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, ATEX/IECEx
SPLIO1BMXCMAZZ
SPLIH1BMXCMAZZ SPLIH2BMXCMAZZ SPLIG1BMXCMAZZ SPLIN1BMXCMAZZ SPLIF6BMXCMAZZ
Accessories
SPXRL-BT-ATEX-O2 25.0%VOL-Modbus-CHR
SPXRL-BT-ATEX-H2S 50ppm-Modbus-CHR SPXRL-BT-ATEX-H2S 100ppm-Modbus-CHR SPXRL-BT-ATEX-H2 1000ppm-Modbus-CHR S
PXRL-BT-ATEX-NO2 20.0ppm-Modbus-CHR (Available Q4 2017) SPXRL-BT-ATEX-CH4 100%LEL-Modbus-CHR
3. Sensepoint XRL
Part Number
Description
SPXRLMAC1
SPXRL-Module Set-mA - CO
SPXRLMAF1
SPXRL-Module Set-mA - Flammable Cat
SPXRLMMC1
SPXRL-Module Set-Modbus - CO
SPXRLMMF1
SPXRL-Module Set-Modbus - Flammable Cat
SPXZZRLF6SS
SPXRL-Replacement Sensor-Cat
SPXCLRLC1SS
Sensepoint XCL/XRL Replacement Sensor - CO
Part Number
Description
SPXRLSK1
SPXRL-Service Kit 2
SPXRLSCP
SPXRL-Sensor Cover Spare
SPXRLSCC
SPXRL-Sensor Trim Ring Spare-CHR
SPXRLSCY
SPXRL-Sensor Trim Ring Spare-YEL
SPXRLCOV
SPXRL-Top Cover Spare
SPXRLSPN
SPXRL-Stopping Plug-3/4" NPT
SPXRLSPM
SPXRL-Stopping Plug-M20
Consumables (Spare Sensors)
13
SPXRLMAO1
SPXRLMAH1 SPXRLMAH2 SPXRLMAG1 SPXRLMAN1
SPXRLMMO2
SPXRLMMH1 SPXRLMMH2 SPXRLMMG1 SPXRLMMN1
SPXCLZZO1SS
SPXCLRLH1SS SPXCLRLG1SS SPXCLRLN1SS
Spares (Miscellaneous)
SPXRL-Module Set-mA - O
2
SPXRL-Module Set-mA - H2S Low Range S
PXRL-Module Set-mA - H2S High Range SPXRL-Module Set-mA - H
2
SPXRL-Module Set-mA - NO2 (Available Q4 2017)
SPXRL-Module Set-Modbus - O
2
SPXRL-Module Set-Modbus - H2S Low Range SPXRL-Module Set-Modbus - H2S High Range S
PXRL-Module Set-Modbus - H
2
SPXRL-Module Set-Modbus - NO2 (Available Q4 2017)
Sensepoint XCL/XRL Replacement Sensor - O
2
Sensepoint XCL/XRL Replacement Sensor - H2S (Low and High Range) Sensepoint XCL/XRL Replacement Sensor - H Sensepoint XCL/XRL Replacement Sensor - NO
2
2
• Removable plug/socket type terminal

4. Sensepoint XCD

B, C and D, Class I, Division 2, Groups B,
14
LEL, C3H8, CH4, H2S, CO, CO2, H2, NO2, O2
The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnetic switches without ever needing to open the unit. This enables one-man, non­intrusive operation and reduces routine maintenance time and costs.
One-Stop Shop
• Flammable (catalytic or infrared), toxic and oxygen Versions available
• New and retrofit applications
• Suitable for indoor or outdoor use
• Stainless steel or aluminium explosion-proof housing options
• IP66 as standard
Proven and Reliable Sensor Technology
• Surecell™ electrochemical Sensors
• Poison immune infrared Sensors
• Poison resistant catalytic bead Sensors
• Long life Sensors
Global Approvals
• Global approvals for US, Canada, Latin America, Europe, China, Korea, and more
• Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
• User friendly and intuitive tri display with digits, bar graph and icons
• Fully configurable via magnetic switches
• Selectable sink or source 4-20 mA output
• Auto-inhibit during maintenance
• Modbus RTU communications for remote diagnostics/configuration
colour backlit
Cost Effective
• Common transmitter platform
• Minimal training required
• Reduced spares
• Non-intrusive, one-man operation
• Plug-in Sensor replacement
• Modbus multi drop option offers cabling savings
Simple Installation
• Plug-in display module removes to give access to terminal area
• Integral Mounting bracket
• 2 x M20 or 3/4 in. NPT Cable/conduit entries (certification dependent)
blocks for ease of wiring
• Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
• Remote Sensor gassing Kit
• Duct Mounting Kit
• Calibration gas flow housing
• Collecting cone
Certifications
• UL/c-UL - Class I, Division 1, Groups
C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
• ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta ­40ºC to +65ºC) Ex tb IIIC T85°C Db IP66
• IEC Ex d IIC Gb T6 (Ta -40ºC to +65ºC) Extb IIIC T85°C Db IP66
4. Sensepoint XCD
Part Number
Description
Part Number
Description
SPXCDULNFXM
UL/c-UL/INMETRO Approvals (LM25) with Modbus
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes catalytic
UL/c-UL/INMETRO Approvals (LM25)
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared carbon dioxide
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes oxygen EC
15
4.1 INSTRUMENT
SPXCDULNFX
SPXCDULNRX
SPXCDULNPX
SPXCDULNO1
SPXCDULNHX
SPXCDULNCX
SPXCDULNNX
SPXCDULNG1
SPXCDULNB1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDULNRXM
SPXCDULNPXM
SPXCDULNO1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
sensor cartridge 0 to 25% v/v, includes nylon weather protection
4. Sensepoint XCD
Part Number
Description
SPXCDUSNFX
SPXCDUSNRX
protection
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared methane
protection
protection
protection
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes catalytic sensor
UL/c-UL/INMETRO Approvals (316SS)
weather protection
nylon weather protection
weather protection
16
SPXCDULNHXM
SPXCDULNCXM
SPXCDULNNXM
SPXCDULNG1M
SPXCDULNB1M
SPXCDUSNPX
SPXCDUSNO1
SPXCDUSNHX
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather
SPXCDUSNCX
SPXCDUSNNX
SPXCDUSNG1
SPXCDUSNB1
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
4. Sensepoint XCD
Part Number
Description
SPXCDUSNFXM
Part Number
Description
SPXCDALMFX
SPXCDALMRX
carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes catalytic sensor
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared methane
weather protection
EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
UL/c-UL/INMETRO Approvals (316SS) with Modbus
ATEX/IECEx/Asian Approvals (LM25)
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes catalytic
weather protection
weather protection
weather protection
nylon weather protection
17
SPXCDUSNRXM
SPXCDUSNPXM
SPXCDUSNO1M
SPXCDUSNHXM
SPXCDUSNCXM
SPXCDUSNNXM
SPXCDUSNG1M
SPXCDUSNB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared
SPXCDALMPX
SPXCDALMO1
SPXCDALMHX
SPXCDALMCX
SPXCDALMNX
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
4. Sensepoint XCD
Part Number
Description
SPXCDALMFXM
Part Number
Description
SPXCDASMFX
SPXCDASMRX
hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes
nylon weather protection
nylon weather protection
nylon weather protection
includes nylon weather protection
ATEX/IECEx/Asian Approvals (LM25) WITH Modbus
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS,
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS,
includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm
ATEX/IECEx/China Approvals (316SS)
18
SPXCDALMG1
SPXCDALMB1
SPXCDALMRXM
SPXCDALMPXM
SPXCDALMO1M
SPXCDALMHXM
SPXCDALMCXM
SPXCDALMG1M
SPXCDALMB1M
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution),
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
SPXCDASMPX
SPXCDASMO1
SPXCDASMHX
SPXCDASMCX
SPXCDASMNX
SPXCDASMG1
SPXCDASMB1
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS,
(1 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather protection
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
4. Sensepoint XCD
Part Number
Description
20% and 100%LEL (10%LEL resolution), includes nylon weather protection
20% and 100%LEL (10%LEL resolution), includes nylon weather protection
ATEX/IECEx/Asian Approvals (316SS) with Modbus
100%LEL (10%LEL resolution), includes nylon weather protection
19
SPXCDASMFXM
SPXCDASMRXM
SPXCDASMPXM
SPXCDASMO1M
SPXCDASMHXM
SPXCDASMCXM
SPXCDASMG1M
SPXCDASMB1M
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection
4. Sensepoint XCD
Part Number
Description
S3KCAL
SPXCDCC
SPXCDDMK
SPXCDMTBR
SPXCDSDP
Part Number
Description
SPXCDXSFXSS
SPXCDXSRXSS
SPXCDXSO1SS
SPXCDXSHXSS
SPXCDXSCXSS
SPXCDXSNXSS
SPXCDXSG1SS
SPXCDXSPXSS
SPXCDXSB1SS
Part Number
Description
SPXCDWP
SPXCDSRLS
SPXCDAKS
SPXCDHWES
SPXCDEBS
SPXCDMAG
Part Number
Description
SPXCDDMT
SPXCDDMF
SPXCDDMTM
SPXCDDMFM
Part Number
Description
SPXCDTMO
SPXCDTMT
SPXCDTMF
Calibration cap
Collecting cone for use with lighter than air gases, must be used with SPXCDWP
Duct mounting kit
Mounting bracket (inc. bolts, nuts, brackets)
Sunshade / deluge protection
Each replacement terminal module includes pre-configured PCB (for Sensor and range), terminals, screws, ‘U’ clamp, plastic cover and fixing
Sensepoint XCD Spares (Replacement Terminal Module)
XCD TRANSMITTER (WITHOUT SENSOR)
Sensepoint XCD standard weather protection
Sensor retainer with locking screw
Allen key for stopper
Hex wrench for earth screw
Earth bracket and screws
Magnetic wand
Replacement display module for oxygen (O2) & toxic
Replacement display module for FL & IR
Replacement display module (O2 & Toxic) with MODBUS
Replacement display module (FL & IR) with MODBUS
Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)
Hydrogen 0-1000ppm only
Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
Carbon Dioxide IR 0-2.00% v/v only
XCD TRANSMITTER (WITHOUT SENSOR)
Replacement terminal module for oxygen (O2)
Replacement terminal module for toxic
Replacement terminal module for FL and IR
Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)
Sensepoint XCD Accessoies
Sensepoint XCD Replacement Toxic, Flammable and Oxygen Cartridges
Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
Oxygen 25.0% v/v only
20
4.2 Accessories
4.3 Sensepoint Replacement Toxic, Flammable and Oxygen Cartridges
4.4 Spares (Miscellaneous)
4.5 Spares (Replacement Display Module)
Each replacement Display Module includes pre-configured PCB (for Sensor and range), backlit LCD and plastic housing. The unit is a plug in replacement and simply requires configuration after fitting via the menu.
4.6 Spares (Replacement Terminal Module)
screws.
4. Sensepoint XCD
Part Number
Product
Components
* XCDTOXKit should be used with XCD-Flammable IR
Contains Part Numbers
21
4.7 Calibration Kits and Components
XCDTOXKit XCD Toxic Kit*
XCDCOMBKit XCD Combustibles
Kit
XCDRTDKit XCD RTD
XCDRFDKit XCD RFD
Tubing, flow adaptor, regulator, carrying case Tubing, flow adaptor, regulator, carrying case Calibration cover, potentiometer, adjustment tool, flow housing, regulator, tubing Tubing, flow adaptor, regulator, carrying case
998
100004 N600 1001 33 998100004 998100012
02000A1645
2106B2114 998100003 998100004 998100003 998100003
S3KCAL
998100003
S3KCAL 998100003 998100004 998100012
00780A0035
998100012
The Sensepoint RFD is a remote flammable detection system for LEL
control panel during maintenance.
- cCSAus approved for Class I, Division 1, Groups B, C & D
- Performance approved to the following standards; C22.2-152,
SPXCDULNRFD
SPXCDULNRFDM
SPXCDUSNRFD
SPXCDUSNRFDM
SPXCDASMRFD
SPXCDALMRFD
SPXCDASMRFDM
SPXCDALMRFDM

5. Sensepoint XCD RFD

22
monitoring applications. The XCD RFD combines the XCD transmitter with the 705 combustible Sensor, and is certified for use in Class I Div. 1 rated areas. The XCD RFD offers one man, non-intrusive, operation and reduces routine maintenance time and costs. The XCD transmitter includes two programmable alarm/fault relays as well as an industry standard 4-20 mA output, with optional Modbus RTU. Calibration and relay operation of the transmitter may be adjusted via the transmitters’ backlit LCD. Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the
Sensepoint RFD is supplied with all necessary accessories for easy installation. It can be mounted on a wall or 2" round support pole using the universal bracket provided. The detector is ideal for use with either conduit or steel wire armored cable and glands and includes both 3/4 in. NPT and M20 entries to the junction box.
Sensepoint RFD offers easy installation and fast routine operation. Compatible with both standard and high temperature variants of the Sensepoint and 705 flammable Sensors from Honeywell Analytics the overall flexibility of the product range is increased. Meets Class I Div. 1 UL performance standards.
Note: Conduit and fittings not included
Certifications
Hazardous Locations.
LEL (*1–*8)
ANSI/ISA 121301
5.1 Sensepoint XCD RFD Transmitter
Transmitter - cCSAus Certified for North America (Class I, Div. 1, Groups B, C & D) - Transmitter only
Part Number Description
Transmitter with LM25, 3/4 in. NPT entry, aluminum Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum Transmitter with 3/4 in. NPT entry, 316SS Transmitter with 3/4 in. NPT entry, Modbus, 316SS
Transmitter - cCSAus Certified for North America (Class I, Div. 1, Groups B, C & D) - Transmitter only
Part Number Description
ATEX/IECEX & AP approved SP XCD RFD Transmitter with 316SS ATEX/IECEX & AP approved SP XCD RFD Transmitter with LM25 ATEX/IECEX & AP approved SP XCD RFD Transmitter, 316SS, 2x M20 and 1x M25 entries, with ModBus ATEX/IECEX & AP approved SP XCD RFD Transmitter, LM25, 2x M20 and 1x M25 entries, with ModBus
5. Sensepoint XCD RFD
23
5.2 Sensors
Sensors
Part Number Description
00705-A-1733 705 combustible sensor - aluminum - cat bead (SG16B) 0-100% LEL
00705-A-1735 705 high temperature combustible sensor - 150°C - UL / 3/4 in. NPT threads
SPXCDXSRFXSS Sensepoint XCD RFD remote plug-in sensor and socket, flammable CAT 0-100%LEL, ATEX only
SPXCDXSRRXSS Sensepoint XCD RFD remote plug-in sensor and socket, Methane IR 0-100%LEL, ATEX only
SPXCDXSRPXSS Sensepoint XCD RFD remote plug-in sensor and socket, Propane IR 0-100%LEL, ATEX only
SPXCDXSRB1SS Sensepoint XCD RFD remote plug-in sensor and socket, Carbon Dioxide IR 0-2.00%VOL only, ATEX only
2106B1202 Sensepoint 0-100% LEL combustible sensor
5.3 Kits
Kits
Part Number Description
CDRFDL Transmitter with LM25, 3/4 in. NPT entry, aluminum, 705 Sensor, and 3 wire junction box
X
XCDRFDLH Transmitter with LM25, 3/4 in. NPT entry, aluminum, 705 high temp Sensor and 3 wire junction box
XCDRFDLM Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 Sensor, and 3 wire junction box
XCDRFDLMH Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 High Temp Sensor, and 3 wire junction box
XCDRFDS Transmitter with 3/4 in. NPT entry, 316SS, with 705 Sensor, and 3 wire junction box
XCDRFDSH Transmitter with 3/4 in. NPT entry, 316SS, 705 high temp Sensor, and 3 wire junction box
XCDRFDSM Transmitter with 3/4 in. NPT entry, Modbus, 316SS, 705 Sensor, and 3 wire junction box
XCDRFDSMH Transmitter with 3/4 in. NPT entry, Modbus, 316SS, 705 high temp Sensor, and 3 wire junction box
5.4 Accessories
Kits
Part Number Description
PXCDMTBR Pipe Mounting bracket (inc. fixings and hex wrench set)
S SPXCDSDP Sunshade / deluge protection 00780-A-0076 Weather protection stainless steel for 705 HT 02000-A-1640 Nylon weather protection for combustible Sensor 02000-A-1635 Weather protection housing 1283-1047 Duct mount adaptor assembly (requires 1283-1084) 1283-1084 Sensepoint adaptor interface Kit (requires 1283-1047) 00780-A-0035 Calibration gas flow adaptor (for use with 705 Sensors)
5.5 Spares
Spares
Part Number Description
SPXCDDMR XCD RFD Flam & IR Display Module SPXCDDMRM XCD RFD Flam & IR ModBus Display Module
SPXCDTMR XCD RFD Replacement Terminal Module
SPXCDDMR XCD RFD Flam & IR Display Module
SPXCDDMRM XCD RFD Flam & IR ModBus Display Module SPXCDTMR XCD RFD Replacement Terminal Module
Part Number
Description
2430K0001
705 Flammable Detector, SG16B Junction Box, WP
Part Number
Description
2441-0022
UL/CSA Aluminium Junction Box Assembly
00780-A-0035
Flow Housing (full stainless steel, for high temp applications)
1283-1047
1283-1084
Part Number
Description
00705-A-1733
705 Flammable Detector- Aluminium- UL- 3/4NPT- 0-100% LEL
00705-A-1735
705 High Temperature Flammable Detector- Aluminum- 150 deg C- UL- 3/4NPT
The 705 Combustible Gas Sensor is a low cost, explosion proof Sensor
998100003
Spares
6. 705
Combustable Gas Detector
High Temperature Version
Accessories
Satellite (with adapter), XNX MPD and Series 2000)
Duct mount adaptor assembly (requires 1283-1084)
Sensepoint adaptor interface Kit (requires 1283-1047)
24
assembly, fitted with poison-resistant combustible gas detection elements. Fully encapsulated, it is designed for use in hazardous locations. The Sensor is electro-catalytic and consists of 2 beads of refractory oxide, formed on a fine platinum wire coil. The active bead is coated with a catalyst material, while the reference bead is glass coated. In the presence of gas, the catalyst coated bead promotes the oxidation of the gas, causing it to heat up and increase in electrical resistance. This change of resistance, relative to the reference bead, can be measured and is in direct proportion to the concentration of combustible gas.
6.1 INSTRUMENT
6.2 ACCESSORIES
02000-A-1640
00780-A-0076
02000-A-1635
02000-A-1642
Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series
Stainless steel weather housing for Sensepoint HT or 705 HT (for use with in high temperature applications or with duct mounting kits)
Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
Collecting cone for use with flammable detector (for Sensepoint, Signalpoint,
Features
• Fast response
• High resistance to catalytic poisoning
• Low cost, high performance design
• Low Powerconsumption
• Accurate, trouble free gas detection
• Corrosion resistant aluminum construction
• Five year warranty
Approvals
• CSA & UL approved (705 HT UL only)
• Class I, Div 1, Groups B, C & D
705CALKIT
Calibration Kit: Tubing, flow adaptor, regulator, carrying case
6.3 SPARES
Contains:
100004
998 00780A0035 998100012 (1.5LPM)
Sensor Fitted to
Remote Junction Box
Note: Conduit and fittings not included

7. Sensepoint XCD RTD

Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2
- Reduce maintenance time and expense with non-intrusive,
25
Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas.
You can mount the unit away from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the Sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored. XCD RTD offers unrivaled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and Mounting options, and onboard diagnostics.
Reduce Cost of Ownership Over Life of the Product Gain Added Flexibility, Reliability and
Performance
- Cut stocking and procurement costs with a common transmitter platform
one-man operation
- Simplify maintenance with plugin, removable Sensor
- Mount in the most difficult to access areas
- Reduce likelihood of human error via on-board diagnostics and easy-to-read display
- Protect against dust/water ingress with IP66/67 rated stainless steel or aluminum enclosure
- Reduce inspection and training time with tri-color ‘traffic light’ display conveying safety status at a glance
- Simplify set-up and configuration with non-intrusive magnetic switches
Certifications
- cCSAus Ex d IIB+H2; Class I, Zone 1, AEx d IIB+H2; Class I, Div 2, Groups B, C & D
- Class I, Zone 1, AEx d ia IIC Gb; Class I, Div. 2, Groups B, C and D
- InMetro Ex d IIC T6 Gb, Ex tb IIIC T85ºC Db, IP66, -40ºC < ta < +65ºC
- Prevent false alarms with autoinhibit during maintenance
- Select sink or source 4-20 mA output; integral or remote configuration
- Full range of accessories and purchase options let you choose the remote monitoring system that’s right for your application
- Optional Modbus RTU communications for remote configuration
7. Sensepoint XCD RTD
7.1 Instrument
26
Sensepoint XCD RTD: Class I, Div. 2 Explosion Proof Transmitter 4-20 mA, 3 Relays) and Sensepoint Toxic Sensor
Part Number Description
SPXCDULNO2 Oxygen (O2) 0-25% v/v, aluminum enclosure
XCDUSNO2 Oxygen (O2) 0-25% v/v, stainless steel enclosure
SP SPXCDULNO2M Oxygen (O2) 0-25% v/v, aluminum enclosure, Modbus SPXCDUSNO2M Oxygen (O2) 0-25% v/v, stainless steel enclosure, Modbus SPXCDULNH2 Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure SPXCDUSNH2 Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure SPXCDULNH2M Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure, Modbus SPXCDUSNH2M Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure, Modbus SPXCDULNC2 Carbon monoxide (CO) 0-200 ppm, aluminum enclosure SPXCDUSNC2 Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure SPXCDULNC2M Carbon monoxide (CO) 0-200 ppm, aluminum enclosure, Modbus SPXCDUSNC2M Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure, Modbus SPXCDULNG2 Hydrogen (H2) 0-1,000 ppm, aluminum enclosure SPXCDUSNG2 Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure SPXCDULNG2M Hydrogen (H2) 0-1,000 ppm, aluminum enclosure, Modbus SPXCDUSNG2M Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure, Modbus SPXCDULNN2 Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure SPXCDUSNN2 Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure SPXCDULNN2M Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus SPXCDUSNN2M Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus
PXCDULNA2 Ammonia (NH3) 0-50 ppm, aluminum enclosure
S SPXCDUSNA2 Ammonia (NH3) 0-50 ppm, stainless steel enclosure SPXCDULNA2M Ammonia (NH3) 0-50 ppm, aluminum enclosure, Modbus SPXCDUSNA2M Ammonia (NH3) 0-50 ppm, stainless steel enclosure, Modbus SPXCDULNL2 Chlorine (Cl2) 0-5 ppm, aluminum enclosure
SPXCDUSNL2 Chlorine (Cl2) 0-5 ppm, stainless steel enclosure SPXCDULNL2M Chlorine (Cl2) 0-5 ppm, aluminum enclosure, Modbus SPXCDUSNL2M Chlorine (Cl2) 0-5 ppm, stainless steel enclosure, Modbus
SPXCDULNS2 Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure SPXCDUSNS2 Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure
SPXCDULNS2M Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure, Modbus SPXCDUSNS2M Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure, Modbus SPXCDULND2 Nitric oxide (NO) 0-100 ppm, aluminum enclosure SPXCDUSND2 Nitric oxide (NO) 0-100 ppm, stainless steel enclosure SPXCDULND2M Nitric oxide (NO) 0-100 ppm, aluminum enclosure, Modbus SPXCDUSND2M Nitric oxide (NO) 0-100 ppm, stainless steel enclosure, Modbus
7. Sensepoint XCD RTD
Sensepoint XCD RTD: Class I, Div. 2: XP Explosion Proof Transmitter (4-20 mA, 3 Relays), Sensepoint Toxic Sensor and
27
Junction Box
Part Number Description
SPXCDULNO2R Oxygen (O2) 0-25%, aluminum enclosure SPXCDUSNO2R Oxygen (O2) 0-25%, stainless steel enclosure SPXCDULNO2RM Oxygen (O2) 0-25%, aluminum enclosure, Modbus SPXCDUSNO2RM Oxygen (O2) 0-25%, stainless steel enclosure, Modbus SPXCDULNH2R Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure SPXCDUSNH2R Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure SPXCDULNH2RM Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure, Modbus SPXCDUSNH2RM Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure, Modbus SPXCDULNC2R Carbon monoxide (CO) 0-200 ppm, aluminum enclosure SPXCDUSNC2R Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure SPXCDULNC2RM Carbon monoxide (CO) 0-200 ppm, aluminum enclosure, Modbus SPXCDUSNC2RM Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure, Modbus SPXCDULNG2R Hydrogen (H2) 0-1,000 ppm, aluminum enclosure SPXCDUSNG2R Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure SPXCDULNG2RM Hydrogen (H2) 0-1,000 ppm, aluminum enclosure, Modbus SPXCDUSNG2RM Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure, Modbus SPXCDULNN2R Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure SPXCDUSNN2R Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure SPXCDULNN2RM Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus SPXCDUSNN2RM Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure, Modbus SPXCDULNA2R Ammonia (NH3) 0-50 ppm, aluminum enclosure SPXCDUSNA2R Ammonia (NH3) 0-50 ppm, stainless steel enclosure SPXCDULNA2RM Ammonia (NH3) 0-50 ppm, aluminum enclosure, Modbus SPXCDUSNA2RM Ammonia (NH3) 0-50 ppm, stainless steel enclosure, Modbus SPXCDULNL2R Chlorine (Cl2) 0-5 ppm, aluminum enclosure
SPXCDUSNL2R Chlorine (Cl2) 0-5 ppm, stainless steel enclosure SPXCDULNL2RM Chlorine (Cl2) 0-5 ppm, aluminum enclosure, Modbus SPXCDUSNL2RM Chlorine (Cl2) 0-5 ppm, stainless steel enclosure, Modbus
SPXCDULNS2R Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure SPXCDUSNS2R Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure
SPXCDULNS2RM Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure, Modbus SPXCDUSNS2RM Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure, Modbus SPXCDULND2R Nitric oxide (NO) 0-10 ppm, aluminum enclosure SPXCDUSND2R Nitric oxide (NO) 0-10 ppm, stainless steel enclosure SPXCDULND2RM Nitric oxide (NO) 0-10 ppm, aluminum enclosure, Modbus SPXCDUSND2RM Nitric oxide (NO) 0-10 ppm, stainless steel enclosure, Modbus
Part Number
Description
Part Number
Description
Part Number
Description
7. Sensepoint XCD RTD
28
7.2 Replacement Sensors
XCD RTD Replacement Sensors: Sensepoint Toxic Sensors Class I, Div. 2 (3/4 in. NPT)
2106B1830 Oxygen (O2) 0-25% v/v Sensor
2106B1801 Hydrogen sulfide (H2S) 0-50 p 2106B1806 Carbon monoxide (CO) 0-200 ppm, Sensor 2106B1816 Hydrogen (H2) 0-1,000 ppm, replacement Sensor
2106B1822 Nitrogen dioxide (NO2) 0-10 ppm, replacement Sensor
2106B1813 Ammonia (NH3) 0-50 ppm, replacement Sensor
2106B1810 Chlorine (Cl2) 0-5 ppm, replacement Sensor
2106B1820 Sulfur dioxide (SO2) 0-15 ppm, replacement Sensor
2106B1818 Nitric oxide (NO) 0-100 ppm, replacement Sensor
7.3 Replacement Spares
XCD RTD Spares Class I, Div. 2
SPXCDULNTX4 Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays
SPXCDUSNTX4 Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, stainless steel
SPXCDULNTX4M Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus
SPXCDUSNTX4M Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus stainless steel
2106B1545 Oxygen (O2) electrochemical cell exchange Kit
2106B1546 Sulfur dioxide (SO2) electrochemical cell exchange Kit
2106B1547 Chlorine (Cl2) electrochemical cell exchange Kit
2106B1548 Carbon monoxide (CO) electrochemical cell exchange Kit
2106B1549 Hydrogen sulfide (H2S) electrochemical cell exchange Kit
106B1594 Nitric oxide (NO) electrochemical cell exchange Kit
2
2106B1596 Ammonia (NH3) 0-50 ppm, electrochemical cell exchange Kit
2106B1597 Hydrogen (H2) 0-1,000 ppm, electrochemical cell exchange Kit
2106B1599 Nitrogen dioxide (NO2) 0-10 ppm, electrochemical cell exchange Kit
2430-0021 Sensepoint XCD RTD remote junction box, 3 terminal
SPXCDDM4 Replacement display module for RTD (4~20mA)
SPXCDDMR Replacement display module for RFD (4~20mA)
SPXCDDM4M Replacement display module for RTD (4~20mA), with MODBUS
SPXCDDMRM Replacement display module for RFD (4~20mA), with MODBUS
1283-1047 Duct mount adaptor assembly (requires 1283-1084)
1283-1084 Sensepoint adaptor interface Kit (requires 1283-1047)
pm, Sensor
7.4 Accessories
Accessories
SPXCDMTBR Pipe mounting bracket (inc. fixings and hex wrench set)
SPXCDSDP Sunshade / deluge protection
02000-A-1635 Series 2000 weather housing use with toxic Sensor
02000-A-1645 Series 2000 flow housing assembly
2106B2114
For all XCD calibration kits and components, please consult the XCD product page or Calibration Kits and Calibration gas pages.
Toxic calibration kit with calibration cover, removal tool, potentiometer adjustment tool Note: Flow housing (02000-A-1645) is required and must be ordered separately.
Part Number
Description
2106B1200
2106B1201
2106B1204
Part Number
Description
2106B2310
2106B2311
2106B2312
Note: For a complete sensor order correct number of FEEL Exe J.Box 2052D0001 and Weather Housing 00780-A-0076
Part Number
Description
2106B1700
2106B1701
2106B1702
2106B1801
2106B1400
2106B1401

8. Sensepoint Flammable and Toxic Hazardous Area

Approved Gas Detectors
Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2
29
Sensepoint is a range of hazardous area certified combustible and toxic gas detectors suitable for indoor and outdoor environments. The combustible version is disposable whereas the toxic version allows users to replace the sensing element.
Certifications include
North America: cCSAus Class I Div. 2 (Toxic only) European: ATEX Australian: SAA
Performance approvals include
European combustible EN50054/57 European toxic pr EN45544 Casing manufactured from PPS plastic
Wiring
Combustible 3 wire mV Toxic 2 wire 4-20 mA
Mounting thread
M20, M25, 3/4 in. NPT
Ordering information
Select gas range and thread from the following tables.
8.1 Instruments
Combustible Sensor (ATEX Only)
Sensepoint 0-100% LEL Flam. Sensor M20 Sensepoint 0-100% LEL Flam. Sensor M25 Sensepoint 0-100% LEL Flam. Sensor 3/4NPT
* please refer to the manual for gas specific unit and range Note: For a complete sensor order correct number of BARTEC J.Box 00780-A-0100 and Weather Housing 02000-A-1640
Combustible Sensor - High Temperature (150°C with 3rd Party Performance Approval)
Sensepoint HT Flammable Sensor (ATEX) M20 Sensepoint HT Flammable Sensor (ATEX) M25 Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT
Sensepoint Toxic Sensor (ATEX)Sensepoint Toxic Sensor (cCSAus Class I, Div. 2)
Sensepoint H2S 0-20 ppm Toxic Sensor 3/4NPT Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT Sensepoint H2S 0-100 ppm Toxic Sensor 3/4NPT Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT CSA Sensepoint H2S 0-20 ppm Toxic Sensor M20 Sensepoint H2S 0-50 ppm Toxic Sensor M20
8. Sensepoint Flammable and Toxic Hazardous Area
Approved Gas Detectors
2106B1402
2106B1706
2106B1707
2106B1806
2106B1405
2106B1406
2106B1407
2106B1711
2106B1810
2106B1410
2106B1411
2106B1713
2106B1714
2106B1715
2106B1813
2106B1413
2106B1414
2106B1415
2106B1816
2106B1817
2106B1416
2106B1417
2106B1818
2106B1418
2106B1820
2106B1420
2106B1421
2106B1822
2106B1422
2106B1730
2106B1830
2106B1430
Note: For a complete sensor order correct number of BARTEC J.Box 00780-A-0100 and Weather Housing 02000-A-1635
Sensepoint H2S 0-100 ppm Toxic Sensor M20
30
Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT Sensepoint CO 0-500 ppm Toxic Sensor 3/4NPT Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT CSA Sensepoint CO 0-100 ppm Toxic Sensor M20 Sensepoint CO 0-200 ppm Toxic Sensor M20 Sensepoint CO 0-500 ppm Toxic Sensor M20 Sensepoint Cl2 0-15 ppm Toxic Sensor 3/4NPT Sensepoint Cl2 0-5 ppm Toxic Sensor 3/4NPT CSA Sensepoint Cl2 0-5 ppm Toxic Sensor M20 Sensepoint Cl2 0-15 ppm Toxic Sensor M20 Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT Sensepoint NH3 0-1000 ppm Toxic Sensor 3/4NPT Sensepoint NH3 0-100 ppm Toxic Sensor 3/4NPT Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT CSA Sensepoint NH3 0-50 ppm Toxic Sensor M20 Sensepoint NH3 0-1000 ppm Toxic Sensor M20 Sensepoint NH3 0-100 ppm Toxic Sensor M20 Sensepoint H2 0-1000 ppm Toxic Sensor 3/4NPT CSA Sensepoint H2 0-10000ppm Toxic Sensor 3/4NPT CSA Sensepoint H2 0-1000 ppm Toxic Sensor M20 Sensepoint H2 0-10000 ppm Toxic Sensor M20 Sensepoint NO 0-100 ppm Toxic Sensor 3/4NPT CSA Sensepoint NO 0-100 ppm Toxic Sensor M20 Sensepoint SO2 0-15 ppm Toxic Sensor 3/4NPT CSA Sensepoint SO2 0-15 ppm Toxic Sensor M20 Sensepoint SO2 0-50 ppm Toxic Sensor M20 Sensepoint NO2 0-10 ppm Toxic Sensor 3/4NPT CSA Sensepoint NO2 0-10 ppm Toxic Sensor M20 Sensepoint O2 25% V/V Toxic Sensor 3/4NPT Sensepoint 0-25 V/V O2 Toxic Sensor 3/4NPT CSA Sensepoint O2 25% V/V Toxic Sensor M20
Loading...
+ 118 hidden pages