2018 Product Guide Americas
Industrial Fixed Gas and Flame Detection
Issue: 1V0
|
Table of Contents |
Page |
1. |
Explosion-Proof Transmitters: Quick Reference Chart.................................................................. |
3 |
2. |
XNX™ Universal Transmitter......................................................................................................... |
4 |
3. |
Sensepoint XRL.............................................................................................................................. |
10 |
4. |
Sensepoint XCD............................................................................................................................. |
14 |
5. |
Sensepoint XCD RFD...................................................................................................................... |
22 |
6. |
705 Combustible Gas Detector..................................................................................................... |
24 |
7. |
Sensepoint XCD RTD..................................................................................................................... |
25 |
8. |
Sensepoint Sensors....................................................................................................................... |
29 |
9. |
Sensepoint with Junction Box....................................................................................................... |
32 |
10. |
Safe Area XCD............................................................................................................................... |
34 |
11. |
Series 3000 MkII and MkIII............................................................................................................ |
35 |
12. |
Infrared Transmitters: Quick Reference Chart.............................................................................. |
38 |
13. |
OELD Smart Junction Box.............................................................................................................. |
39 |
14. |
Searchpoint Optima Plus............................................................................................................... |
40 |
15. |
Searchpoint Optima Plus Calibrations........................................................................................... |
46 |
16. |
Searchline Excel............................................................................................................................. |
50 |
17. |
Searchline Excel XD....................................................................................................................... |
56 |
18. |
FSX Detectors: Quick Reference Chart.......................................................................................... |
58 |
19. |
FSX Detectors Applications Chart.................................................................................................. |
59 |
20. |
Model FS24X................................................................................................................................. |
60 |
21. |
Model FS20X................................................................................................................................. |
65 |
22. |
FS10 Fire Detection Systems......................................................................................................... |
68 |
23. |
FS7 Flame Detector....................................................................................................................... |
71 |
24. |
SS Series Flame Detectors: Quick Reference Chart........................................................................ |
73 |
25. |
SS4-A2, AS, & AUV Series.............................................................................................................. |
74 |
26. |
SS2-AM Series............................................................................................................................... |
79 |
27. |
FSL100 Flame Detector................................................................................................................. |
80 |
28. |
RAEGuard 2 PID............................................................................................................................. |
81 |
29. |
Gas Detection Controllers: Quick Reference Chart........................................................................ |
84 |
30. |
Touchpoint Pro Digital Gas Controller........................................................................................... |
85 |
31. |
Touchpoint Plus Digital Gas Controller.......................................................................................... |
107 |
32. |
HA20 & HA40 Digital Gas Controllers............................................................................................ |
113 |
33. |
HA71 Digital Gas Controller........................................................................................................... |
116 |
34. |
HA72 Digital Gas Controller........................................................................................................... |
118 |
35. |
System 57 Control for Fire and Gas Detection.............................................................................. |
120 |
36. |
Unipoint DIN Rail Mounted Controller.......................................................................................... |
123 |
37. |
Safe Area and Intrinsically Safe Transmitters: Quick Reference Chart.......................................... |
124 |
38. |
Satellite XT Gas Detector Transmitter........................................................................................... |
125 |
39. |
Midas® Extractive Gas Detector.................................................................................................... |
131 |
40. |
SPM Flex........................................................................................................................................ |
136 |
41. |
Accessories.................................................................................................................................... |
|
|
Horns & Strobes............................................................................................................................ |
139 |
|
PowerSupplies & Additional Accessories...................................................................................... |
140 |
|
Calibration Reference Guide......................................................................................................... |
141 |
|
Calibration Kits, Components and Gas.......................................................................................... |
142 |
|
Calibration Gases.......................................................................................................................... |
144 |
42. |
Honeywell Analytics Service.......................................................................................................... |
146 |
1. Explosion-Proof Transmitters
Quick Reference Chart
Product |
Display |
Relays |
Material |
Communication |
Bluetooth® |
|
|
|
|
|
|
|
|
|
|
|
|
4-20 mA; HART; |
|
|
XNX™ Universal Transmitter |
Y |
DC |
AL, SS |
Modbus; |
N |
|
Foundation |
||||||
|
|
|
|
|
||
Optima Excel Local Display |
|
|
|
Fieldbus |
|
|
Y |
No |
AL, SS |
4-20 mA; HART |
Y |
||
(OELD) |
passthrough |
|||||
|
|
|
|
|||
Sensepoint XCD |
Y |
DC |
AL, SS |
4-20 mA; Modbus |
N |
|
Sensepoint XCD RTD |
Y |
DC |
AL, SS |
4-20 mA; Modbus |
N |
|
Sensepoint XCD RFD |
Y |
DC |
AL, SS |
4-20 mA; Modbus |
N |
|
Sensepoint XRL |
N (Light Ring Only) |
No |
AL |
4-20 mA; Modbus |
Y |
|
Series 3000 MKII/MKIII |
Y |
No |
AL, SS |
4-20 mA |
N |
|
705 Sensor |
Y |
No |
SS |
4-20 mA |
N |
|
Optima Plus |
N (Y w/ XNX) |
No |
SS |
4-20 mA; HART |
N (Y w/ OELD) |
Toxic Gas Sensor |
XNX™ |
XCD |
XCD RTD |
XRL |
S3000 |
Ammonia (NH3) |
X |
|
X |
X* |
X |
Arsine (AsH3) |
|
|
|
|
|
Boron Trichloride (BCl3) |
|
|
|
|
|
Bromine (Br2) |
|
|
|
|
|
Carbon Monoxide (CO) |
X |
X |
X |
X |
X |
Carbon Dioxide (CO2) |
X |
X |
|
X* |
|
Chlorine (Cl2) |
X |
|
X |
X* |
X |
Chlorine Dioxide (ClO2) |
X |
|
|
|
X |
Diborane (B2H6) |
|
|
|
|
|
Dichlorosilane (H2SiCl2) |
|
|
|
|
|
Ethylene Oxide (EtO) |
X |
|
|
|
X |
Fluorine (F2) |
|
|
|
|
|
Germane (GeH4) |
|
|
|
|
|
Hydrogen (H2) |
X |
X |
X |
X |
X |
Hydrogen Bromide (HBr) |
|
|
|
|
|
Hydrogen Chloride (HCl) |
X |
|
|
|
X |
Hydrogen Cyanide (HCN) |
|
|
|
|
X |
Hydrogen Fluoride (HF) |
X |
|
|
|
X |
Hydrogen Sulfide (H2S) |
X |
X |
X |
X |
X |
Nitric Oxide (NO) |
X |
|
X |
|
X |
Nitrogen Dioxide (NO2) |
X |
X |
X |
X |
X |
Oxygen (O2) |
X |
X |
X |
X |
X |
Ozone (O3) |
|
|
|
X* |
|
Phosphine (PH3) |
X |
|
|
|
X |
Silane (SiH4) |
|
|
|
|
|
Sulfur Dioxide (SO2) |
X |
|
X |
X* |
X |
*Will be added in 2018 |
|
|
|
|
|
LEL Sensor |
XNX™ |
XCD/XRL¹ |
XCD RFD |
705 |
OELD/Optima |
Non-specific combustible |
X |
X |
X |
X |
X |
Butane (C4H10) |
X |
X |
X |
X |
X |
Butyl Acetate (C6H12O2) |
X |
X |
X |
X |
X |
Ethylene (C2H4) |
X |
X |
X |
X |
X |
Hexane (C6H14) |
X |
X |
X |
X |
X |
Hydrogen (H2) |
X |
X |
X |
X |
X |
Methane (CH4) |
X |
X |
X |
X |
X |
Pentane (C5H12) |
X |
X |
X |
X |
X |
Propane (C3H8) |
X |
X |
X |
X |
X |
Toluene (C7H8) |
X |
X |
X |
X |
X |
Note: |
|
|
|
|
|
1. XRL calibrated to Methane. Please contact HA customer service for other flammable gasses.
3
C2H4, C3H8, C4H10, C5H12, C6H12O2, C6H14, C7H8, CH4, Cl2, ClO2,
CO, CO2, H2, H2S, HCl, HF, LEL, NH3, NO, NO2, O2, PH3, SO2
The XNX™ Universal Transmitter, now with HART EDDL/DTM, marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of Sensors on a common platform and offers a modular choice of inputs and outputs. XNX is designed for flexible integration, simple installation, user-friendly operation and straight-forward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. The introduction of our HART Enhanced Device Descriptor Language (EDDL) & Device Type Manager (DTM) software provides users with an at-a-glance indication of the health of their gas detectors in the field.
High performance
-Flammable gas detection 0 to 100% LFL/LEL
-Point IR with heated optics provides immunity to poisoning and no hidden faults
-Open-path IR flammable gas detection in LEL- m measurement
-Electrochemical cell offers toxic gas detection in ppm
-IR cell provides CO2 and combustible gas monitoring
-Robust and reliable operation in explosive areas and harsh environments
Cost Effective
-Minimal training required
-One-man operation
-Plug-in Sensor replacement
-All necessary accessories included
Flexible Operation
-3 Versions - supports (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
-Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
-4-20 mA with HART® as standard
-HART Enhanced Device Description Language (EDDL) & Device Type Manager (DTM) software*
-Multiple communications optionsinclude up to 3 relays, Modbus® and FOUNDATION® H1 Fieldbus
-Optional local IS port for handheld HART configurator
Easy to Install
-3 or 4 wire operation, source, sink or isolated
-Simple plug-in Sensors and replaceable cells
-NEMA 4X IP66 rated for rugged indoor/outdoor use
-Five conduit entries for ease of installation
Easy to Use
-Large, backlit, easy-to-view LCD display offers multiSensory indicators (visual icons, colored buttons, text, etc.) to display gas and Sensor readings
-User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
-Self-test and fault indication features
-Non-intrusive, one-man operation
-Quick calibration with auto-inhibit
Certifications
- UL, CSA, FM, DEMKO, DEKRA, InMetro, TUV, ABS, HART, IELDBus Foundation, GOST and KTL approved for Hazardous Locations, Gas Performance and SIL 2 ratings among others
-Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups F and G; Hazardous Locations
-Class I Zone 1 Group IIC, Class II, Zone 20 & 21
-Intrinsically safe barriers for HART
and EC connections
- For additional information on certifications and approvals contact Honeywell Analytics
4
2. XNX™ Universal Transmitter
2.1 XNX Order Number and Pricing Configurator
The XNX™ Universal Transmitter is designed for flexible integration, simple installation, user-friendly operation and straight-forward maintenance. The XNX supports a wide range of Sensors on a common platform and offers a modular choice of inputs and outputs.
> Sensor Personality
Electrochemical
Infrared (Optima/Excel) or 4-20 mA input (Sensepoint, etc.)
milliVolt
> Enclosure Material
Aluminum |
|
|
A |
|
|
|
|
Painted Stainless Steel |
|
|
S |
|
|
|
|
> Agency Approval & Thread Type |
|
|
|
|
|
|
|
ATEX/IEC M25 |
|
AM |
|
UL/CSA 3/4” NPT |
|
UT |
|
|
|
|
|
INMETRO 3/4” NPT |
|
BT |
|
> XNX Base Unit |
|
|
|
XNX Base Unit |
XNX |
|
|
|
|
|
|
E
I
V
> Interface Options
N |
|
None |
|
|
|
|
|
|
|
R |
|
Relay |
|
|
|
|
|
|
|
M |
|
Modbus |
|
|
|
|
|
|
|
F |
|
Foundation Fieldbus |
|
|
|
|
|
|
|
|
> Local HART |
|
|
|
|
N |
None |
|
|
|
H |
Local HART® Port |
||
|
|
|
|
|
|
|
NNN |
|
None* |
|
|
> MPD Sensor |
*for milliVolt versions only (must |
|
|
|
and Range |
select 'V' sensor personality) |
|
|
|
CB1 |
Catalytic Bead %LEL |
|
|
|
IF1 |
IR %LEL Flammable |
|
|
|
IV1 |
IR CH4 0-5% Vol/100% LEL |
|
|
|
|
|
|
|
|
IC1 |
IR CO2 0-5% Vol |
|
|
|
|
|
|
*Always used for “I” and “E” Sensor personality.
Order number: |
XNX |
|
|
UT |
A |
E |
|
|
F |
H |
NNN |
|
|
|
|
For example, the order number for an XNX (XNX-) configured for UL/CSA Approval and 3/4" NPT thread type (UT), Aluminum enclosure (A), Electrochemical sensor personality (E-), Foundation Fieldbus interface (F), and Local HART (H) would be XNX-UTAE-FHNNN.
Multi-Purpose Detector (MPD)
The MPD (Multi-Purpose Detector), a low-cost Infrared or Catalytic bead sensing cell for monitoring flammable industrial gases in hazardous areas. Through the XNX, the MPD can support a variety of communications protocol used in industrial communications systems.
> Agency Approval
ATEX |
|
A |
UL/CSA |
|
U |
INMETRO |
|
B |
|
|
|
>MPD Base Unit |
|
|
MPD Base Unit |
MPD |
|
> Port Threads
T |
3/4 NPT |
|
M |
M25 |
|
|
> Sensor |
|
|
CB1 |
Catalytic Bead %LEL |
|
IF1 |
IR %LEL Flammable |
|
IV1 |
IR CH4 0-5% Vol |
|
IC1 |
IR CO2 0-5% Vol |
Order number: |
MPD |
|
|
U |
T |
CB1 |
|
|
For example, the order number for an MPD (MPD-) configured for UL/CSA Approval (U), 3/4” NPT thread type (T), and Catalytic Bead %LEL Sensor (CB1) would be MPDUTCB1.
5
2.XNX™ Universal Transmitter
2.2Toxic and Oxygen Smart Sensors
A wide range of toxic and oxygen sensors, featuring patented Surecell™ and Reflex technology, are available for use with the XNX™ Universal Transmitter. Featuring a field replaceable sensor, these sensors are shipped pre-calibrated to the range listed below.
XNX™ Sensors
Part Number |
Description |
XNXXSO1FM |
Oxygen (O2) 23% v/v fixed (FM approved) |
|
|
XNXXSO1SS |
Oxygen (O2) 0-25% v/v |
XNXXSC1SS |
Carbon monoxide (CO) 0-300 ppm (100 to 500 ppm max scale for XNX, 100 ppm) |
XNXXSC1FM |
Carbon monoxide (CO) 100-1000 ppm (FM approved) |
XNXXSH3SS |
Hydrogen sulfide (H2S) 0-15 ppm |
XNXXSH1FM |
Hydrogen sulfide (H2S) 10-50 ppm (FM approved) |
XNXXSH1SS |
Hydrogen sulfide (H2S) 0-15.0 ppm (10.0 to 50.0 ppm, 1 ppm) |
XNXXSH2SS |
Hydrogen sulfide (H2S) 0-100 ppm (50 to 500 ppm, 10 ppm) |
XNXXSL1SS |
Chlorine (Cl2) 0-5.0 ppm (5.0 to 20.0 ppm, 5.0 ppm) |
XNXXSL2SS |
Chlorine (Cl2) 0-5.00 ppm fixed range |
XNXXSS1SS |
Sulfur dioxide (SO2) 0-15.0 ppm (5.0 to 20.0 ppm, 5.0 ppm) |
XNXXSS2SS |
Sulfur dioxide (SO2) 0-50.0 ppm (20.0 to 50 ppm, 10 ppm) |
XNXXSX1SS |
Chlorine dioxide (ClO2) 0-1.00 ppm |
XNXXSM1SS |
Nitric oxide (NO) 0-100 ppm |
XNXXSN1SS |
Nitrogen dioxide (NO2) 0-10.0 ppm (5.0 to 50.0 ppm, 5.0 ppm) |
XNXXSG1SS |
Hydrogen (H2) 0-1000 ppm |
XNXXSG2SS |
Hydrogen (H2) 0-10,000 ppm |
XNXXSF1SS |
Hydrogen fluoride (HF) 0-12.0 ppm |
XNXXSA1SS |
Ammonia (NH3) 0-200 ppm (50 to 200 ppm, 50 ppm) |
XNXXSA2SS |
Ammonia (NH3) 0-1000 ppm (200 to 1000 ppm, 50 ppm) |
XNXXSP1SS |
Phosphine (PH3) 0-1.2 ppm |
XNXXSR1SS |
Hydrogen chloride (HCl) 0-10 ppm (10 to 20 ppm, 1 ppm) |
XNXXSY1SS |
XNX Sensor hydrogen cyanide (HCN) 0-30 ppm (Fixed Scale) |
XNXXSE1SS |
XNX Sensor ethylene oxide (EtO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) |
MPD: Multi-Purpose Detector (mV) - UL/CSA (3/4 in. NPT)
Part Number |
Description |
MPD-UTCB1 |
XNX MPD UL/CSA catalytic bead Sensor 0-100% LEL |
MPD-UTIF1 |
XNX MPD UL IR cartridge 0-100% LEL propane (C3H8) (flammables) |
MPD-UTIV1 |
XNX MPD UL IR cartridge 0-100% LEL methane (CH4) |
MPD-UTIC1 |
XNX MPD UL/cUL IR cartridge carbon dioxide (CO2) 0-5% VV |
Note: When remote Mounting the MPD, Ferrite Bead (0060-1051) is required.
MPD: Multi-Purpose Detector (mV) - ATEX/IECEX (M25)
Part Number |
Description |
MPD-AMCB1 |
XNX MPD ATEX/IECEx catalytic bead Sensor 0-100% LEL |
MPD-AMIF1 |
XNX MPD ATEX/IECEx IR cartridge 0-100% LEL propane (flammables) |
MPD-AMIV1 |
XNX MPD ATEX/IECEx IR cartridge 0-100% LEL methane |
MPD-AMIC1 |
XNX MPD ATEX/IECEx IR cartridge CO2 0-5% VV |
6
2.XNX™ Universal Transmitter
2.3XNX™ Accessories
XNX™ Accessories: For Use With All Versions of XNX
Part Number |
Description |
94000-A-1006 |
XNX Sunshade w/ Optima cut out |
|
|
1226A0358 |
Pipe mount Kit |
|
|
1226A0355 |
Ceiling mount bracket |
|
|
S3KDMK |
Duct mount Kit |
1226A0354 |
Remote gassing Kit |
|
|
2441-0022 |
UL/CSA aluminum 6 wire junction box assembly |
2430-0021 |
UL/CSA aluminum 3 wire junction box assembly |
|
|
00780-A-0100 |
ATEX/IECEx junction box assembly |
XNX™ Accessories: For Use With MPD Catalytic and IR Cartridge Sensors
Part Number |
Description |
1226A0382 |
MPD interface adaptor (required with duct mount Kit for MPD) |
|
Note: S3KDMK and 1226A0382 should be order together |
1226A0411 |
Calibration gas flow adaptor (for use with MPD) |
02000-A-1645 |
Calibration gas flow adaptor (for use with Sensepoint Sensors) |
00780-A-0035 |
Calibration gas flow adaptor (for use with 705 Sensors) |
02000-A-1640 |
Weatherproof cap (for use with MPD and Sensepoint Sensors) |
02000-A-1635 |
Weatherproof cap (for use with 705 Sensors) |
02000-A-1642 |
Collecting cone (for use with MPD, Sensepoint and 705 Sensors) |
0060-1051 |
Ferrite bead (for use with mV Sensors) |
|
|
XNX™ Accessories: For Use With Toxic and Oxygen Sensors
Part Number |
Description |
S3KRMK |
Remote EC Mounting Kit (50 Feet) |
S3KRMK45 |
Remote EC Mounting Kit (150 Feet) |
S3KRMK75 |
Remote EC Mounting Kit (250 Feet) |
SPXCDWP |
Enclosed weather protection housing with bump port |
|
|
S3KWP |
Weatherproof housing (for use with corrosives) |
|
|
S3KCAL |
Calibration gas flow adaptor (for use with EC Sensors) |
|
|
SPXCDCC |
Collecting cone for use with lighter than air gases |
|
Note: must be used with SPXCDWP weather protection housing. |
Replacement Toxic and Oxygen Sensor Cartridges
Part Number |
Description |
S3KO1SS |
Oxygen (O2) 0-25% v/v |
S3KC1SS |
Carbon monoxide (CO) 0-300 ppm (100 to 999 ppm, 100 ppm) |
S3KH1SS |
Hydrogen sulfide (H2S) 0-15 ppm (10 to 50 ppm, 1 ppm) |
S3KH2SS |
Hydrogen sulfide (H2S) 0-100 ppm (50 to 500 ppm, 10 ppm) |
S3KL1SS |
Chlorine (Cl2) 0-5.0 ppm (5.0 to 20.0 ppm, 5.0 ppm) |
S3KS1SS |
Sulfur dioxide (SO2) 0-15.0 ppm (5.0 to 20.0 ppm, 5 ppm); 0-50.0 ppm (20.0 to 50.0 ppm, 10 ppm) |
S3KX1SS |
Chlorine dioxide (ClO2) 0-1.00 ppm |
S3KM1SS |
Nitric oxide (NO) 0-100 ppm |
S3KN1SS |
Nitrogen dioxide (NO2) 0-10.0 ppm (5.0 to 50.0 ppm, 5.0 ppm) |
S3KG1SS |
Hydrogen (H2) 0-1000 ppm |
7
2. XNX™ Universal Transmitter
Replacement Toxic and Oxygen Sensor Cartridges continued
Part Number |
Description |
S3KG2SS |
Hydrogen (H2) 0-10,000 ppm |
S3KA1SS |
Ammonia (NH3) 0-200 ppm (50 to 200 ppm, 50 ppm) |
S3KA2SS |
Ammonia (NH3) 0-1000 ppm (200 to 1000 ppm, 50 ppm) |
S3KP1SS |
Phosphine (PH3) 0-1.2 ppm |
S3KR1SS |
Hydrogen chloride (HCl) 0-10 ppm (10 to 20 ppm, 1 ppm) |
XNXE1SS |
Ethylene Oxide (EtO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) |
Replaceable MPD Catalytic and IR Cartridges
Part Number |
Description |
|
1226A0359 |
Replacement catalytic bead Sensor 0-100% LEL |
|
1226-0300 |
Replacement IR cartridge 0-100% |
LEL propane (C3H8) (flammables) |
1226-0299 |
Replacement IR cartridge 0-100% |
LEL methane (CH4) |
1226-0301 |
Replacement IR cartridge carbon dioxide (CO2) 0-5% VV |
XNX™ Spares
Part Number |
Description |
1226-0257 |
M25 stopping plug with protective cap and O-ring (Stainless Steel) |
1226-0258 |
3/4 in. NPT stopping plug with protective cap and O-ring (Stainless Steel) |
0235-0238 |
Replacement O-ring for XNX front cover |
1226A0302 |
Terminal block assembly 6-pin for XNX EC |
1226A0304 |
Terminal block assembly 9-pin for XNX mV |
1226A0305 |
IR terminal block assembly Kit includes: 9-pin and 2 pin blocks |
1226A0306 |
Relay terminal block assembly Kit includes: 9-pin and 2-pin blocks |
1226A0307 |
Terminal block assembly 10-pin for XNX Modbus |
1226-0254 |
Magnetic wand/screwdriver |
1226-0408 |
Small screwdriver (for use with relay board and IR personality board) |
1226-0350 |
Sensor Retainer, includes set screw. (SS cover for EC sensor.) |
1226A0303 |
Terminal block assembly 6-pin XNX Foundation Fieldbus |
XNX™ PODs*
Part Number |
Description |
1226-9001 |
XNX POD IR personality |
|
|
1226-9002 |
XNX POD IR personality with relay option |
1226-9003 |
XNX POD IR personality with Modbus option |
1226-9004 |
XNX POD IR personality with FFB option |
1226-9005 |
XNX POD ECC personality |
1226-9006 |
XNX POD ECC personality with relay option |
1226-9007 |
XNX POD ECC personality with Modbus option |
1226-9008 |
XNX POD ECC personality with FFB option |
1226-9009 |
XNX POD MV personality |
1226-9010 |
XNX POD MV personality with relay option |
1226-9011 |
XNX POD MV personality with Modbus option |
1226-9012 |
XNX POD MV personality with FFB option |
*Terminal blocks are NOT included with PODs
8
2.XNX™ Universal Transmitter
2.4Calibration Kits and Components
XNX™ Calibrarion Kits and Components |
Product |
Contains |
Part Number |
Tubing, flow adaptor, regulator, carrying case |
XNX Toxic Kit |
998 100 004, S3KCAL, |
XNXTOXKit |
|
|
ZCALREG1 (.3 LPM), |
|
|
|
998 100 003 |
|
|
|
|
|
Tubing, flow adaptor, regulator, carrying case |
XNX Toxic Kit (HCN, Cl2, |
|
XNXTOXKIT2 |
|
HF, NH3, and HCl) |
|
|
|
|
|
|
Tubing, flow adaptor, regulator, carrying case |
XNX Combustibles Kit |
106459, 1226A0411, N600 |
XNXCOMBKit |
|
|
1001 33 (.5 LPM), |
|
|
|
998 100 003 |
|
|
|
|
|
XNX EC barrier service kit |
|
|
1226A0368 |
|
1226A0057 |
||
3/4 inch EC potted assembly |
|
|
1226A0369 |
Flow housing XNX S3K EC cell, teflon |
|
|
SVIP3766-007 |
Flow housing XNX S3K MPD, IR, cat bead |
|
|
SVIP3766-008 |
9
Sensepoint XRL is a fixed point gas leak detector that is designed to meet the needs of industrial applications. With over 50 years experience in gas leak detection, Honeywell offers a flexible range of highly-reliable sensing devices to meet those needs.
•Quick installation
•Rapid configuration
•Simple to operate
•Straightforward to maintain
Honeywell innovation enables customers to pair the gas detector with their mobile phone, and then use an app to perform many tasks related to installation, commissioning and maintenance.
3.1 Instruments
Each Sensepoint XRL is supplied with registration sheet, 3/4 NPT or M20 metal stopping plug, Hex Allen key and quick start guide. Sensepoint XRL is fully configurable via Bluetooth on your Android Smart Device.
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, cULus
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, cULus
Part Number |
Description |
SPLIO1BAXYNUZZ |
SPXRL-BT-cULus-O2 25.0%VOL-mA-YEL |
SPLIC1BAXYNUZZ |
SPXRL-BT-cULus-CO 300ppm-mA-YEL |
SPLIH1BAXYNUZZ |
SPXRL-BT-cULus-H2S 50ppm-mA-YEL |
SPLIH2BAXYNUZZ |
SPXRL-BT-cULus-H2S 100ppm-mA-YEL |
SPLIG1BAXYNUZZ |
SPXRL-BT-cULus-H2 1000ppm-mA-YEL |
SPLIN1BAXYNUZZ |
SPXRL-BT-cULus-NO2 20.0ppm-mA-YEL (Available Q4 2017) |
SPLIF6BAXYNUZZ |
SPXRL-BT-cULus-CH4 100%LEL-mA-YEL |
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, cULus
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, cULus
Part Number |
Description |
SPLIO1BAXCNUZZ |
SPXRL-BT-cULus-O2 25.0%VOL-mA-CHR |
SPLIC1BAXCNUZZ |
SPXRL-BT-cULus-CO 300ppm-mA-CHR |
SPLIH1BAXCNUZZ |
SPXRL-BT-cULus-H2S 50ppm-mA-CHR |
SPLIH2BAXCNUZZ |
SPXRL-BT-cULus-H2S 100ppm-mA-CHR |
SPLIG1BAXCNUZZ |
SPXRL-BT-cULus-H2 1000ppm-mA-CHR |
SPLIN1BAXCNUZZ |
SPXRL-BT-cULus-NO2 20.0ppm-mA-CHR (Available Q4 2017) |
SPLIF6BAXCNUZZ |
SPXRL-BT-cULus-CH4 100%LEL-mA-CHR |
|
|
10
3. Sensepoint XRL
Sensepoint XRL, Bluetooth, Yellow, Modbus, cULus
Sensepoint XRL, Bluetooth, Yellow, Modbus, cULus
Part Number |
Description |
SPLIO1BMXYNUZZ |
SPXRL-BT-cULus-O2 25.0%VOL-Modbus-YEL |
SPLIC1BMXYNUZZ |
SPXRL-BT-cULus-CO 300ppm-Modbus-YEL |
SPLIH1BMXYNUZZ |
SPXRL-BT-cULus-H2S 50ppm-Modbus-YEL |
SPLIH2BMXYNUZZ |
SPXRL-BT-cULus-H2S 100ppm-Modbus-YEL |
SPLIG1BMXYNUZZ |
SPXRL-BT-cULus-H2 1000ppm-Modbus-YEL |
SPLIN1BMXYNUZZ |
SPXRL-BT-cULus-NO2 20.0ppm-Modbus-YEL (Available Q4 2017) |
SPLIF6BMXYNUZZ |
SPXRL-BT-cULus-CH4 100%LEL-Modbus-YEL |
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, cULus
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, cULus
Part Number |
Description |
SPLIO1BMXCNUZZ |
SPXRL-BT-cULus-O2 25.0%VOL-Modbus-CHR |
SPLIC1BMXCNUZZ |
SPXRL-BT-cULus-CO 300ppm-Modbus-CHR |
SPLIH1BMXCNUZZ |
SPXRL-BT-cULus-H2S 50ppm-Modbus-CHR |
SPLIH2BMXCNUZZ |
SPXRL-BT-cULus-H2S 100ppm-Modbus-CHR |
SPLIG1BMXCNUZZ |
SPXRL-BT-cULus-H2 1000ppm-Modbus-CHR |
SPLIN1BMXCNUZZ |
SPXRL-BT-cULus-NO2 20.0ppm-Modbus-CHR (Available Q4 2017) |
SPLIF6BMXCNUZZ |
SPXRL-BT-cULus-CH4 100%LEL-Modbus-CHR |
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, ATEX/IECEx
Sensepoint XRL, Bluetooth, Yellow, 4-20mA, ATEX/IECEx
Part Number |
Description |
SPLIO1BAXYMAZZ |
SPXRL-BT-ATEX-O2 25.0%VOL-mA-YEL |
SPLIC1BAXYMAZZ |
SPXRL-BT-ATEX-CO 300ppm-mA-YEL |
SPLIH1BAXYMAZZ |
SPXRL-BT-ATEX-H2S 50ppm-mA-YEL |
SPLIH2BAXYMAZZ |
SPXRL-BT-ATEX-H2S 100ppm-mA-YEL |
SPLIG1BAXYMAZZ |
SPXRL-BT-ATEX-H2 1000ppm-mA-YEL |
SPLIN1BAXYMAZZ |
SPXRL-BT-ATEX-NO2 20.0ppm-mA-YEL (Available Q4 2017) |
SPLIF6BAXYMAZZ |
SPXRL-BT-ATEX-CH4 100%LEL-mA-YEL |
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, ATEX/IECEx
Sensepoint XRL, Bluetooth, Charcoal Grey, 4-20mA, ATEX/IECEx
Part Number |
Description |
SPLIO1BAXCMAZZ |
SPXRL-BT-ATEX-O2 25.0%VOL-mA-CHR |
SPLIC1BAXCMAZZ |
SPXRL-BT-ATEX-CO 300ppm-mA-CHR |
SPLIH1BAXCMAZZ |
SPXRL-BT-ATEX-H2S 50ppm-mA-CHR |
SPLIH2BAXCMAZZ |
SPXRL-BT-ATEX-H2S 100ppm-mA-CHR |
SPLIG1BAXCMAZZ |
SPXRL-BT-ATEX-H2 1000ppm-mA-CHR |
SPLIN1BAXCMAZZ |
SPXRL-BT-ATEX-NO2 20.0ppm-mA-CHR (Available Q4 2017) |
SPLIF6BAXCMAZZ |
SPXRL-BT-ATEX-CH4 100%LEL-mA-CHR |
|
|
11
3. Sensepoint XRL
Sensepoint XRL, Bluetooth, Yellow, Modbus, ATEX/IECEx
Sensepoint XRL, Bluetooth, Yellow, Modbus, ATEX/IECEx
Part Number |
Description |
SPLIO1BMXYMAZZ |
SPXRL-BT-ATEX-O2 25.0%VOL-Modbus-YEL |
SPLIC1BMXYMAZZ |
SPXRL-BT-ATEX-CO 300ppm-Modbus-YEL |
SPLIH1BMXYMAZZ |
SPXRL-BT-ATEX-H2S 50ppm-Modbus-YEL |
SPLIH2BMXYMAZZ |
SPXRL-BT-ATEX-H2S 100ppm-Modbus-YEL |
SPLIG1BMXYMAZZ |
SPXRL-BT-ATEX-H2 1000ppm-Modbus-YEL |
SPLIN1BMXYMAZZ |
SPXRL-BT-ATEX-NO2 20.0ppm-Modbus-YEL (Available Q4 2017) |
SPLIF6BMXYMAZZ |
SPXRL-BT-ATEX-CH4 100%LEL-Modbus-YEL |
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, ATEX/IECEx
Sensepoint XRL, Bluetooth, Charcoal Grey, Modbus, ATEX/IECEx
Part Number |
Description |
SPLIO1BMXCMAZZ |
SPXRL-BT-ATEX-O2 25.0%VOL-Modbus-CHR |
SPLIC1BMXCMAZZ |
SPXRL-BT-ATEX-CO 300ppm-Modbus-CHR |
SPLIH1BMXCMAZZ |
SPXRL-BT-ATEX-H2S 50ppm-Modbus-CHR |
SPLIH2BMXCMAZZ |
SPXRL-BT-ATEX-H2S 100ppm-Modbus-CHR |
SPLIG1BMXCMAZZ |
SPXRL-BT-ATEX-H2 1000ppm-Modbus-CHR |
SPLIN1BMXCMAZZ |
SPXRL-BT-ATEX-NO2 20.0ppm-Modbus-CHR (Available Q4 2017) |
SPLIF6BMXCMAZZ |
SPXRL-BT-ATEX-CH4 100%LEL-Modbus-CHR |
3.2 Accessories, Consumables & Spares
Accessories
Part Number |
Description |
SPXRLCAL |
SPXRL-Calibration Cap |
SPXRLFLW |
SPXRL-Flow Housing |
SPXRLDMK |
SPXRL-Duct Mount Kit |
2308B0923 |
Pipe Mounting Bracket Kit |
SPXCDWP |
Sensepoint XRL optional weather protection |
SPXCDCC |
Collecting cone for use with lighter than air gases, must be used with SPXCDWP |
|
|
12
3. Sensepoint XRL
Consumables (Spare Sensors)
Part Number |
Description |
SPXRLMAO1 |
SPXRL-Module Set-mA - O2 |
SPXRLMAC1 |
SPXRL-Module Set-mA - CO |
SPXRLMAH1 |
SPXRL-Module Set-mA - H2S Low Range |
SPXRLMAH2 |
SPXRL-Module Set-mA - H2S High Range |
SPXRLMAG1 |
SPXRL-Module Set-mA - H2 |
SPXRLMAN1 |
SPXRL-Module Set-mA - NO2 (Available Q4 2017) |
SPXRLMAF1 |
SPXRL-Module Set-mA - Flammable Cat |
SPXRLMMO2 |
SPXRL-Module Set-Modbus - O2 |
SPXRLMMC1 |
SPXRL-Module Set-Modbus - CO |
SPXRLMMH1 |
SPXRL-Module Set-Modbus - H2S Low Range |
SPXRLMMH2 |
SPXRL-Module Set-Modbus - H2S High Range |
SPXRLMMG1 |
SPXRL-Module Set-Modbus - H2 |
SPXRLMMN1 |
SPXRL-Module Set-Modbus - NO2 (Available Q4 2017) |
SPXRLMMF1 |
SPXRL-Module Set-Modbus - Flammable Cat |
SPXZZRLF6SS |
SPXRL-Replacement Sensor-Cat |
SPXCLZZO1SS |
Sensepoint XCL/XRL Replacement Sensor - O2 |
SPXCLRLC1SS |
Sensepoint XCL/XRL Replacement Sensor - CO |
SPXCLRLH1SS |
Sensepoint XCL/XRL Replacement Sensor - H2S (Low and High Range) |
SPXCLRLG1SS |
Sensepoint XCL/XRL Replacement Sensor - H2 |
SPXCLRLN1SS |
Sensepoint XCL/XRL Replacement Sensor - NO2 |
|
|
Spares (Miscellaneous) |
|
Part Number |
Description |
SPXRLSK1 |
SPXRL-Service Kit 2 |
SPXRLSCP |
SPXRL-Sensor Cover Spare |
SPXRLSCC |
SPXRL-Sensor Trim Ring Spare-CHR |
SPXRLSCY |
SPXRL-Sensor Trim Ring Spare-YEL |
SPXRLCOV |
SPXRL-Top Cover Spare |
SPXRLSPN |
SPXRL-Stopping Plug-3/4" NPT |
SPXRLSPM |
SPXRL-Stopping Plug-M20 |
13
LEL, C3H8, CH4, H2S, CO, CO2, H2, NO2, O2
The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnetic switches without ever needing to open the unit. This enables one-man, nonintrusive operation and reduces routine maintenance time and costs.
One-Stop Shop
•Flammable (catalytic or infrared), toxic and oxygen Versions available
•New and retrofit applications
•Suitable for indoor or outdoor use
•Stainless steel or aluminium explosion-proof housing options
•IP66 as standard
Proven and Reliable Sensor Technology
•Surecell™ electrochemical Sensors
•Poison immune infrared Sensors
•Poison resistant catalytic bead Sensors
•Long life Sensors
Global Approvals
•Global approvals for US, Canada, Latin America, Europe, China, Korea, and more
•Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
•User friendly and intuitive tri colour backlit display with digits, bar graph and icons
•Fully configurable via magnetic switches
•Selectable sink or source 4-20 mA output
•Auto-inhibit during maintenance
•Modbus RTU communications for remote diagnostics/configuration
Cost Effective
•Common transmitter platform
•Minimal training required
•Reduced spares
•Non-intrusive, one-man operation
•Plug-in Sensor replacement
•Modbus multi drop option offers cabling savings
Simple Installation
•Plug-in display module removes to give access to terminal area
•Integral Mounting bracket
•2 x M20 or 3/4 in. NPT Cable/conduit entries (certification dependent)
•Removable plug/socket type terminal blocks for ease of wiring
•Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
•Remote Sensor gassing Kit
•Duct Mounting Kit
•Calibration gas flow housing
•Collecting cone
Certifications
•UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G,
Class II, Division 2, Groups F & G. -40°C to +65°C
•ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta - 40ºC to +65ºC) Ex tb IIIC T85°C Db IP66
•IEC Ex d IIC Gb T6 (Ta -40ºC to +65ºC) Extb IIIC T85°C Db IP66
14
4. Sensepoint XCD
4.1 INSTRUMENT
UL/c-UL/INMETRO Approvals (LM25)
Part Number |
Description |
SPXCDULNFX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes catalytic sensor |
|
cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather |
|
protection |
|
|
SPXCDULNRX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared methane |
|
sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather |
|
protection |
|
|
SPXCDULNPX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared propane |
|
sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather |
|
protection |
SPXCDULNO1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes oxygen EC sensor |
|
cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDULNHX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen sulfide EC |
|
sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather |
|
protection |
|
|
SPXCDULNCX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes carbon monoxide EC |
|
sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather |
|
protection |
SPXCDULNNX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes nitrogen dioxide EC |
|
sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather |
|
protection |
SPXCDULNG1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen EC sensor |
|
cartridge 0 to 1000ppm, includes nylon weather protection |
|
|
SPXCDULNB1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared carbon dioxide |
|
sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
UL/c-UL/INMETRO Approvals (LM25) with Modbus |
|
Part Number |
Description |
SPXCDULNFXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes catalytic |
SPXCDULNRXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared |
|
methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon |
|
weather protection |
SPXCDULNPXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared |
|
propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon |
|
weather protection |
SPXCDULNO1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes oxygen EC |
|
sensor cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
15
4. Sensepoint XCD
|
|
SPXCDULNHXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen |
|
sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon |
|
weather protection |
SPXCDULNCXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes carbon |
|
monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes |
|
nylon weather protection |
SPXCDULNNXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes nitrogen |
|
dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon |
|
weather protection |
SPXCDULNG1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes hydrogen |
|
EC sensor cartridge 0 to 1000ppm, includes nylon weather protection |
SPXCDULNB1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted LM25, includes infrared |
|
carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
UL/c-UL/INMETRO Approvals (316SS) |
|
Part Number |
Description |
SPXCDUSNFX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes catalytic sensor |
SPXCDUSNRX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared methane |
SPXCDUSNPX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared propane |
|
sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather |
|
protection |
SPXCDUSNO1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes oxygen EC sensor |
|
cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDUSNHX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen sulfide EC |
|
sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather |
|
protection |
SPXCDUSNCX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes carbon monoxide EC |
|
sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon weather |
|
protection |
SPXCDUSNNX |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes nitrogen dioxide EC |
|
sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather |
|
protection |
SPXCDUSNG1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen EC sensor |
|
cartridge 0 to 1000ppm, includes nylon weather protection |
|
|
SPXCDUSNB1 |
XCD Gas Detector, 4 to 20 mA output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared carbon |
|
dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
|
|
16
4. Sensepoint XCD
UL/c-UL/INMETRO Approvals (316SS) with Modbus
Part Number |
Description |
SPXCDUSNFXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes catalytic |
SPXCDUSNRXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared |
|
methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon |
|
weather protection |
SPXCDUSNPXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared |
|
propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon |
|
weather protection |
SPXCDUSNO1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes oxygen |
|
EC sensor cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDUSNHXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen |
|
sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon |
|
weather protection |
SPXCDUSNCXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes carbon |
|
monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes |
|
nylon weather protection |
SPXCDUSNNXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes nitrogen |
|
dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon |
|
weather protection |
SPXCDUSNG1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes hydrogen |
|
EC sensor cartridge 0 to 1000ppm, includes nylon weather protection |
SPXCDUSNB1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, UL/c-UL/INMETRO, 2 x 3/4" NPT entries, painted 316SS, includes infrared |
|
carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
ATEX/IECEx/Asian Approvals (LM25) |
|
Part Number |
Description |
SPXCDALMFX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes catalytic sensor |
SPXCDALMRX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared methane |
SPXCDALMPX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared propane |
|
sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes nylon weather |
|
protection |
|
|
SPXCDALMO1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes oxygen EC sensor |
|
cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDALMHX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen sulfide |
|
EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes nylon weather |
|
protection |
|
|
SPXCDALMCX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes carbon monoxide |
|
EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), includes nylon |
|
weather protection |
|
|
SPXCDALMNX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes nitrogen dioxide |
|
EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm (5 ppm resolution), includes nylon weather |
|
protection |
|
|
17
4. Sensepoint XCD
|
|
SPXCDALMG1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes hydrogen EC |
|
sensor cartridge 0 to 1000ppm, includes nylon weather protection |
SPXCDALMB1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes infrared carbon |
|
dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
ATEX/IECEx/Asian Approvals (LM25) WITH Modbus |
|
Part Number |
Description |
SPXCDALMFXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
SPXCDALMRXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes |
|
nylon weather protection |
SPXCDALMPXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and 100%LEL (10%LEL resolution), includes |
|
nylon weather protection |
SPXCDALMO1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection |
SPXCDALMHXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm (1 ppm resolution), includes |
|
nylon weather protection |
SPXCDALMCXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and 1000ppm (100 ppm resolution), |
|
includes nylon weather protection |
SPXCDALMG1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection |
SPXCDALMB1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted LM25, includes |
|
infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
ATEX/IECEx/China Approvals (316SS) |
|
Part Number |
Description |
SPXCDASMFX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
SPXCDASMRX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
SPXCDASMPX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and |
|
100%LEL (10%LEL resolution), includes nylon weather protection |
|
|
SPXCDASMO1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDASMHX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between 10 and 100ppm |
|
(1 ppm resolution), includes nylon weather protection |
|
|
SPXCDASMCX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD between 100 and |
|
1000ppm (100 ppm resolution), includes nylon weather protection |
|
|
SPXCDASMNX |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes nitrogen dioxide EC sensor cartridge 0 to 10ppm, user selectable FSD between 10 and 50ppm |
|
(5 ppm resolution), includes nylon weather protection |
|
|
SPXCDASMG1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection |
|
|
SPXCDASMB1 |
XCD Gas Detector, 4 to 20 mA output, ATEX/IECEx/Asian approvals, 2 x M20 entries, painted 316SS, |
|
includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather protection |
|
|
|
|
18
4. Sensepoint XCD
ATEX/IECEx/Asian Approvals (316SS) with Modbus
Part Number |
Description |
SPXCDASMFXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes catalytic sensor cartridge 0 to 100%LEL, user selectable FSD between 20% and |
|
100%LEL (10%LEL resolution), includes nylon weather protection |
SPXCDASMRXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes infrared methane sensor cartridge 0 to 100%LEL, user selectable FSD between |
|
20% and 100%LEL (10%LEL resolution), includes nylon weather protection |
SPXCDASMPXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes infrared propane sensor cartridge 0 to 100%LEL, user selectable FSD between |
|
20% and 100%LEL (10%LEL resolution), includes nylon weather protection |
SPXCDASMO1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes oxygen EC sensor cartridge 0 to 25% v/v, includes nylon weather protection |
|
|
SPXCDASMHXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes hydrogen sulfide EC sensor cartridge 0 to 50ppm, user selectable FSD between |
|
10 and 100ppm (1 ppm resolution), includes nylon weather protection |
SPXCDASMCXM |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes carbon monoxide EC sensor cartridge 0 to 300ppm, user selectable FSD |
|
between 100 and 1000ppm (100 ppm resolution), includes nylon weather protection |
SPXCDASMG1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes hydrogen EC sensor cartridge 0 to 1000ppm, includes nylon weather protection |
|
|
SPXCDASMB1M |
XCD Gas Detector, 4 to 20 mA and Modbus output, ATEX/IECEx/Asian approvals, 2 x M20 entries, |
|
painted 316SS, includes infrared carbon dioxide sensor cartridge 0 to 2.0% v/v, includes nylon weather |
|
protection |
|
|
19
4. Sensepoint XCD
4.2 Accessories
Sensepoint XCD Accessoies
Part Number |
Description |
S3KCAL |
Calibration cap |
SPXCDCC |
Collecting cone for use with lighter than air gases, must be used with SPXCDWP |
SPXCDDMK |
Duct mounting kit |
SPXCDMTBR |
Mounting bracket (inc. bolts, nuts, brackets) |
SPXCDSDP |
Sunshade / deluge protection |
4.3 Sensepoint Replacement Toxic, Flammable and Oxygen Cartridges
Sensepoint XCD Replacement Toxic, Flammable and Oxygen Cartridges
Part Number |
Description |
SPXCDXSFXSS |
Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) |
SPXCDXSRXSS |
Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL) |
SPXCDXSO1SS |
Oxygen 25.0% v/v only |
SPXCDXSHXSS |
Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) |
SPXCDXSCXSS |
Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) |
SPXCDXSNXSS |
Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) |
SPXCDXSG1SS |
Hydrogen 0-1000ppm only |
SPXCDXSPXSS |
Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) |
SPXCDXSB1SS |
Carbon Dioxide IR 0-2.00% v/v only |
4.4 Spares (Miscellaneous)
XCD TRANSMITTER (WITHOUT SENSOR)
Part Number |
Description |
SPXCDWP |
Sensepoint XCD standard weather protection |
SPXCDSRLS |
Sensor retainer with locking screw |
SPXCDAKS |
Allen key for stopper |
SPXCDHWES |
Hex wrench for earth screw |
SPXCDEBS |
Earth bracket and screws |
SPXCDMAG |
Magnetic wand |
4.5 Spares (Replacement Display Module)
Each replacement Display Module includes pre-configured PCB (for Sensor and range), backlit LCD and plastic housing. The unit is a plug in replacement and simply requires configuration after fitting via the menu.
XCD TRANSMITTER (WITHOUT SENSOR)
Part Number |
Description |
SPXCDDMT |
Replacement display module for oxygen (O2) & toxic |
SPXCDDMF |
Replacement display module for FL & IR |
SPXCDDMTM |
Replacement display module (O2 & Toxic) with MODBUS |
SPXCDDMFM |
Replacement display module (FL & IR) with MODBUS |
4.6 Spares (Replacement Terminal Module)
Each replacement terminal module includes pre-configured PCB (for Sensor and range), terminals, screws, ‘U’ clamp, plastic cover and fixing screws.
Sensepoint XCD Spares (Replacement Terminal Module)
Part Number |
Description |
SPXCDTMO |
Replacement terminal module for oxygen (O2) |
SPXCDTMT |
Replacement terminal module for toxic |
SPXCDTMF |
Replacement terminal module for FL and IR |
20
4. Sensepoint XCD
4.7 Calibration Kits and Components
Part Number |
Product |
Components |
|
|
Contains Part Numbers |
|
|
||
XCDTOXKit |
XCD Toxic Kit* |
Tubing, flow adaptor, regulator, |
998 |
100 |
|
004 |
S3KCAL |
||
|
|
carrying case |
N600 1001 33 |
998 |
100 |
003 |
|||
|
|
|
|
|
|
|
|
||
XCDCOMBKit |
XCD Combustibles |
Tubing, flow adaptor, regulator, |
998 |
100 |
|
004 |
S3KCAL |
||
|
Kit |
carrying case |
998 100 012 |
998 |
100 |
003 |
|||
|
|
|
|
|
|
|
|||
XCDRTDKit |
XCD RTD |
Calibration cover, potentiometer, |
02000 A 1645 |
998 |
100 |
004 |
|||
|
|
adjustment tool, flow housing, |
|
|
|
998 |
100 |
012 |
|
|
|
2106B2114 |
|||||||
|
|
regulator, tubing |
998 |
100 |
|
003 |
|
|
|
XCDRFDKit |
XCD RFD |
Tubing, flow adaptor, regulator, |
998 |
100 |
|
004 |
00780 A 0035 |
||
|
|
carrying case |
998 |
100 |
|
003 |
|
|
|
|
|
|
998 100 012 |
||||||
|
|
|
998 100 003 |
|
|
|
|||
* XCDTOXKit should be used with XCD-Flammable IR |
|
|
|
|
|
|
|
21
LEL (*1–*8)
The Sensepoint RFD is a remote flammable detection system for LEL monitoring applications. The XCD RFD combines the XCD transmitter with the 705 combustible Sensor, and is certified for use in Class I Div. 1 rated areas. The XCD RFD offers one man, non-intrusive, operation and reduces routine maintenance time and costs. The XCD transmitter includes two programmable alarm/fault relays as well as an industry standard 4-20 mA output, with optional Modbus RTU. Calibration and relay operation of the transmitter may be adjusted via the transmitters’ backlit LCD. Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance.
Sensepoint RFD is supplied with all necessary accessories for easy installation. It can be mounted on a wall or 2" round support pole using the universal bracket provided. The detector is ideal for use with either conduit or steel wire armored cable and glands and includes both
3/4 in. NPT and M20 entries to the junction box.
Sensepoint RFD offers easy installation and fast routine operation. Compatible with both standard and high temperature variants of the Sensepoint and 705 flammable Sensors from Honeywell Analytics the overall flexibility of the product range is increased. Meets Class I Div. 1 UL performance standards.
Note: Conduit and fittings not included
Certifications
-cCSAus approved for Class I, Division 1, Groups B, C & D Hazardous Locations.
-Performance approved to the following standards; C22.2-152, ANSI/ISA 121301
5.1 Sensepoint XCD RFD Transmitter
Transmitter - cCSAus Certified for North America (Class I, Div. 1, Groups B, C & D) - Transmitter only
Part Number |
Description |
|
|
SPXCDULNRFD |
Transmitter with LM25, 3/4 in. NPT entry, aluminum |
SPXCDULNRFDM |
Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum |
SPXCDUSNRFD |
Transmitter with 3/4 in. NPT entry, 316SS |
SPXCDUSNRFDM |
Transmitter with 3/4 in. NPT entry, Modbus, 316SS |
Transmitter - cCSAus Certified for North America (Class I, Div. 1, Groups B, C & D) - Transmitter only
Part Number |
Description |
|
|
SPXCDASMRFD |
ATEX/IECEX & AP approved SP XCD RFD Transmitter with 316SS |
SPXCDALMRFD |
ATEX/IECEX & AP approved SP XCD RFD Transmitter with LM25 |
SPXCDASMRFDM |
ATEX/IECEX & AP approved SP XCD RFD Transmitter, 316SS, 2x M20 and 1x M25 entries, with ModBus |
SPXCDALMRFDM |
ATEX/IECEX & AP approved SP XCD RFD Transmitter, LM25, 2x M20 and 1x M25 entries, with ModBus |
22
5.Sensepoint XCD RFD
5.2Sensors
Sensors
Part Number |
Description |
00705-A-1733 705 combustible sensor - aluminum - cat bead (SG16B) 0-100% LEL
00705-A-1735 705 high temperature combustible sensor - 150°C - UL / 3/4 in. NPT threads
SPXCDXSRFXSS Sensepoint XCD RFD remote plug-in sensor and socket, flammable CAT 0-100%LEL, ATEX only
SPXCDXSRRXSS Sensepoint XCD RFD remote plug-in sensor and socket, Methane IR 0-100%LEL, ATEX only
SPXCDXSRPXSS Sensepoint XCD RFD remote plug-in sensor and socket, Propane IR 0-100%LEL, ATEX only
SPXCDXSRB1SS Sensepoint XCD RFD remote plug-in sensor and socket, Carbon Dioxide IR 0-2.00%VOL only, ATEX only
2106B1202 Sensepoint 0-100% LEL combustible sensor
5.3 Kits
Kits
Part Number |
Description |
|
|
XCDRFDL |
Transmitter with LM25, 3/4 in. NPT entry, aluminum, 705 Sensor, and 3 wire junction box |
|
|
XCDRFDLH |
Transmitter with LM25, 3/4 in. NPT entry, aluminum, 705 high temp Sensor and 3 wire junction box |
|
|
XCDRFDLM |
Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 Sensor, and 3 wire junction box |
|
|
XCDRFDLMH |
Transmitter with LM25, 3/4 in. NPT entry, Modbus, aluminum, 705 High Temp Sensor, and 3 wire junction box |
|
|
XCDRFDS |
Transmitter with 3/4 in. NPT entry, 316SS, with 705 Sensor, and 3 wire junction box |
|
|
XCDRFDSH |
Transmitter with 3/4 in. NPT entry, 316SS, 705 high temp Sensor, and 3 wire junction box |
|
|
XCDRFDSM |
Transmitter with 3/4 in. NPT entry, Modbus, 316SS, 705 Sensor, and 3 wire junction box |
|
|
XCDRFDSMH |
Transmitter with 3/4 in. NPT entry, Modbus, 316SS, 705 high temp Sensor, and 3 wire junction box |
|
|
5.4 Accessories |
|
|
|
Kits |
|
|
|
Part Number |
Description |
|
|
SPXCDMTBR |
Pipe Mounting bracket (inc. fixings and hex wrench set) |
|
|
SPXCDSDP |
Sunshade / deluge protection |
00780-A-0076 |
Weather protection stainless steel for 705 HT |
02000-A-1640 |
Nylon weather protection for combustible Sensor |
02000-A-1635 |
Weather protection housing |
1283-1047 |
Duct mount adaptor assembly (requires 1283-1084) |
1283-1084 |
Sensepoint adaptor interface Kit (requires 1283-1047) |
00780-A-0035 |
Calibration gas flow adaptor (for use with 705 Sensors) |
|
|
5.5 Spares |
|
Spares |
|
Part Number |
Description |
|
|
SPXCDDMR |
XCD RFD Flam & IR Display Module |
SPXCDDMRM |
XCD RFD Flam & IR ModBus Display Module |
|
|
SPXCDTMR |
XCD RFD Replacement Terminal Module |
|
|
SPXCDDMR |
XCD RFD Flam & IR Display Module |
SPXCDDMRM |
XCD RFD Flam & IR ModBus Display Module |
SPXCDTMR |
XCD RFD Replacement Terminal Module |
23
6. 705
Combustable Gas Detector
The 705 Combustible Gas Sensor is a low cost, explosion proof Sensor assembly, fitted with poison-resistant combustible gas detection elements. Fully encapsulated, it is designed for use in hazardous locations. The Sensor is electro-catalytic and consists of 2 beads of refractory oxide, formed on a fine platinum wire coil. The active bead is coated with a catalyst material, while the reference bead is glass coated. In the presence of gas, the catalyst coated bead promotes the oxidation of the gas, causing it to heat up and increase in electrical resistance. This change of resistance, relative to the reference bead, can be measured and is in direct proportion to the concentration of combustible gas.
Features |
Approvals |
• Fast response |
• CSA & UL approved (705 HT UL only) |
• High resistance to catalytic |
• Class I, Div 1, Groups B, C & D |
poisoning |
|
•Low cost, high performance design
•Low Powerconsumption
•Accurate, trouble free gas detection
•Corrosion resistant aluminum construction
•Five year warranty
6.1 INSTRUMENT
High Temperature Version
Part Number |
Description |
2430K0001 |
705 Flammable Detector, SG16B Junction Box, WP |
6.2 ACCESSORIES
Accessories
Part Number |
Description |
|
2441-0022 |
UL/CSA Aluminium Junction Box Assembly |
|
02000-A-1640 |
Weatherproof cap for use with combustible detector including remote gassing |
|
|
nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series |
|
|
|
|
00780-A-0035 |
Flow Housing (full stainless steel, for high temp applications) |
|
00780-A-0076 |
Stainless steel weather housing for Sensepoint HT or 705 HT (for use with in high |
|
|
temperature applications or with duct mounting kits) |
|
|
|
|
02000-A-1635 |
Weatherproof cap for use with toxic detector including remote gassing nozzle (for |
|
|
Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) |
|
|
|
|
02000-A-1642 |
Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, |
|
|
Satellite (with adapter), XNX MPD and Series 2000) |
|
1283-1047 |
Duct mount adaptor assembly (requires 1283-1084) |
|
1283-1084 |
Sensepoint adaptor interface Kit (requires 1283-1047) |
|
705CALKIT |
Calibration Kit: |
Contains: |
|
Tubing, flow adaptor, regulator, |
998 100 004 |
|
carrying case |
00780 A 0035 |
|
|
|
|
|
998 100 012 (1.5LPM) |
|
|
998 100 003 |
6.3 SPARES |
|
|
Spares |
|
|
Part Number |
Description |
|
00705-A-1733 |
705 Flammable DetectorAluminiumUL- 3/4NPT- 0-100% LEL |
|
00705-A-1735 |
705 High Temperature Flammable DetectorAluminum150 deg C- UL- 3/4NPT |
|
|
|
|
24
Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2
Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas.
You can mount the unit away from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the Sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored. XCD RTD offers unrivaled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and Mounting options, and onboard diagnostics.
Reduce Cost of Ownership Over Life of the Product
- Cut stocking and procurement costs with a common transmitter platform
- Reduce maintenance time and expense with non-intrusive, one-man operation
- Simplify maintenance with plug in, removable Sensor
- Reduce inspection and training time with tri-color ‘traffic light’ display conveying safety status at a glance
- Simplify set-up and configuration with non-intrusive magnetic switches
Certifications
- cCSAus Ex d IIB+H2; Class I, Zone 1, AEx d IIB+H2; Class I, Div 2, Groups B, C & D
- Class I, Zone 1, AEx d ia IIC Gb; Class I, Div. 2, Groups B, C and D
- InMetro Ex d IIC T6 Gb, Ex tb IIIC T85ºC Db, IP66, -40ºC < ta < +65ºC
Gain Added Flexibility, Reliability and
Performance
-Mount in the most difficult to access areas
-Reduce likelihood of human error via on-board diagnostics and easy-to-read display
-Protect against dust/water ingress with IP66/67 rated stainless steel or aluminum enclosure
-Prevent false alarms with auto inhibit during
-Select sink or source 4-20 mA output; integral or remote configuration
-Full range of accessories and purchase options let you choose the remote monitoring system that’s right for your application
-Optional Modbus RTU communications for remote configurationmaintenance
Sensor Fitted to
Remote Junction Box
Note: Conduit and fittings not included
25
7. Sensepoint XCD RTD
7.1 Instrument
Sensepoint XCD RTD: Class I, Div. 2 Explosion Proof Transmitter 4-20 mA, 3 Relays) and Sensepoint Toxic Sensor
Part Number |
Description |
SPXCDULNO2 |
Oxygen (O2) 0-25% v/v, aluminum enclosure |
|
|
SPXCDUSNO2 |
Oxygen (O2) 0-25% v/v, stainless steel enclosure |
SPXCDULNO2M |
Oxygen (O2) 0-25% v/v, aluminum enclosure, Modbus |
|
|
SPXCDUSNO2M |
Oxygen (O2) 0-25% v/v, stainless steel enclosure, Modbus |
SPXCDULNH2 |
Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure |
|
|
SPXCDUSNH2 |
Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure |
|
|
SPXCDULNH2M |
Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure, Modbus |
SPXCDUSNH2M |
Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure, Modbus |
SPXCDULNC2 |
Carbon monoxide (CO) 0-200 ppm, aluminum enclosure |
|
|
SPXCDUSNC2 |
Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure |
SPXCDULNC2M |
Carbon monoxide (CO) 0-200 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNC2M |
Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNG2 |
Hydrogen (H2) 0-1,000 ppm, aluminum enclosure |
SPXCDUSNG2 |
Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure |
|
|
SPXCDULNG2M |
Hydrogen (H2) 0-1,000 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNG2M |
Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNN2 |
Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure |
SPXCDUSNN2 |
Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure |
|
|
SPXCDULNN2M |
Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus |
SPXCDUSNN2M |
Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus |
SPXCDULNA2 |
Ammonia (NH3) 0-50 ppm, aluminum enclosure |
SPXCDUSNA2 |
Ammonia (NH3) 0-50 ppm, stainless steel enclosure |
SPXCDULNA2M |
Ammonia (NH3) 0-50 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNA2M |
Ammonia (NH3) 0-50 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNL2 |
Chlorine (Cl2) 0-5 ppm, aluminum enclosure |
|
|
SPXCDUSNL2 |
Chlorine (Cl2) 0-5 ppm, stainless steel enclosure |
|
|
SPXCDULNL2M |
Chlorine (Cl2) 0-5 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNL2M |
Chlorine (Cl2) 0-5 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNS2 |
Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure |
SPXCDUSNS2 |
Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure |
SPXCDULNS2M |
Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNS2M |
Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULND2 |
Nitric oxide (NO) 0-100 ppm, aluminum enclosure |
|
|
SPXCDUSND2 |
Nitric oxide (NO) 0-100 ppm, stainless steel enclosure |
|
|
SPXCDULND2M |
Nitric oxide (NO) 0-100 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSND2M |
Nitric oxide (NO) 0-100 ppm, stainless steel enclosure, Modbus |
|
|
26
7. Sensepoint XCD RTD
Sensepoint XCD RTD: Class I, Div. 2: XP Explosion Proof Transmitter (4-20 mA, 3 Relays), Sensepoint Toxic Sensor and
Junction Box
Part Number |
Description |
SPXCDULNO2R |
Oxygen (O2) 0-25%, aluminum enclosure |
|
|
SPXCDUSNO2R |
Oxygen (O2) 0-25%, stainless steel enclosure |
SPXCDULNO2RM |
Oxygen (O2) 0-25%, aluminum enclosure, Modbus |
|
|
SPXCDUSNO2RM |
Oxygen (O2) 0-25%, stainless steel enclosure, Modbus |
SPXCDULNH2R |
Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure |
SPXCDUSNH2R |
Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure |
|
|
SPXCDULNH2RM |
Hydrogen sulfide (H2S) 0-50 ppm, aluminum enclosure, Modbus |
SPXCDUSNH2RM |
Hydrogen sulfide (H2S) 0-50 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNC2R |
Carbon monoxide (CO) 0-200 ppm, aluminum enclosure |
SPXCDUSNC2R |
Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure |
SPXCDULNC2RM |
Carbon monoxide (CO) 0-200 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNC2RM |
Carbon monoxide (CO) 0-200 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNG2R |
Hydrogen (H2) 0-1,000 ppm, aluminum enclosure |
SPXCDUSNG2R |
Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure |
|
|
SPXCDULNG2RM |
Hydrogen (H2) 0-1,000 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNG2RM |
Hydrogen (H2) 0-1,000 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNN2R |
Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure |
SPXCDUSNN2R |
Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure |
|
|
SPXCDULNN2RM |
Nitrogen dioxide (NO2) 0-10 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNN2RM |
Nitrogen dioxide (NO2) 0-10 ppm, stainless steel enclosure, Modbus |
SPXCDULNA2R |
Ammonia (NH3) 0-50 ppm, aluminum enclosure |
SPXCDUSNA2R |
Ammonia (NH3) 0-50 ppm, stainless steel enclosure |
|
|
SPXCDULNA2RM |
Ammonia (NH3) 0-50 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNA2RM |
Ammonia (NH3) 0-50 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNL2R |
Chlorine (Cl2) 0-5 ppm, aluminum enclosure |
|
|
SPXCDUSNL2R |
Chlorine (Cl2) 0-5 ppm, stainless steel enclosure |
|
|
SPXCDULNL2RM |
Chlorine (Cl2) 0-5 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNL2RM |
Chlorine (Cl2) 0-5 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULNS2R |
Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure |
SPXCDUSNS2R |
Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure |
SPXCDULNS2RM |
Sulfur dioxide (SO2) 0-15 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSNS2RM |
Sulfur dioxide (SO2) 0-15 ppm, stainless steel enclosure, Modbus |
|
|
SPXCDULND2R |
Nitric oxide (NO) 0-10 ppm, aluminum enclosure |
|
|
SPXCDUSND2R |
Nitric oxide (NO) 0-10 ppm, stainless steel enclosure |
|
|
SPXCDULND2RM |
Nitric oxide (NO) 0-10 ppm, aluminum enclosure, Modbus |
|
|
SPXCDUSND2RM |
Nitric oxide (NO) 0-10 ppm, stainless steel enclosure, Modbus |
|
|
27
7.Sensepoint XCD RTD
7.2Replacement Sensors
XCD RTD Replacement Sensors: Sensepoint Toxic Sensors Class I, Div. 2 (3/4 in. NPT)
Part Number |
Description |
2106B1830 |
Oxygen (O2) 0-25% v/v Sensor |
|
|
2106B1801 |
Hydrogen sulfide (H2S) 0-50 ppm, Sensor |
|
|
2106B1806 |
Carbon monoxide (CO) 0-200 ppm, Sensor |
|
|
2106B1816 |
Hydrogen (H2) 0-1,000 ppm, replacement Sensor |
|
|
2106B1822 |
Nitrogen dioxide (NO2) 0-10 ppm, replacement Sensor |
|
|
2106B1813 |
Ammonia (NH3) 0-50 ppm, replacement Sensor |
|
|
2106B1810 |
Chlorine (Cl2) 0-5 ppm, replacement Sensor |
|
|
2106B1820 |
Sulfur dioxide (SO2) 0-15 ppm, replacement Sensor |
|
|
2106B1818 |
Nitric oxide (NO) 0-100 ppm, replacement Sensor |
|
|
7.3 Replacement Spares |
|
|
|
XCD RTD Spares Class I, Div. 2 |
|
|
|
Part Number |
Description |
SPXCDULNTX4 |
Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays |
|
|
SPXCDUSNTX4 |
Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, stainless steel |
|
|
SPXCDULNTX4M |
Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus |
|
|
SPXCDUSNTX4M |
Sensepoint XCD RTD transmitter, 4-20 mA, 3 relays, Modbus stainless steel |
|
|
2106B1545 |
Oxygen (O2) electrochemical cell exchange Kit |
|
|
2106B1546 |
Sulfur dioxide (SO2) electrochemical cell exchange Kit |
|
|
2106B1547 |
Chlorine (Cl2) electrochemical cell exchange Kit |
|
|
2106B1548 |
Carbon monoxide (CO) electrochemical cell exchange Kit |
|
|
2106B1549 |
Hydrogen sulfide (H2S) electrochemical cell exchange Kit |
|
|
2106B1594 |
Nitric oxide (NO) electrochemical cell exchange Kit |
|
|
2106B1596 |
Ammonia (NH3) 0-50 ppm, electrochemical cell exchange Kit |
|
|
2106B1597 |
Hydrogen (H2) 0-1,000 ppm, electrochemical cell exchange Kit |
|
|
2106B1599 |
Nitrogen dioxide (NO2) 0-10 ppm, electrochemical cell exchange Kit |
|
|
2430-0021 |
Sensepoint XCD RTD remote junction box, 3 terminal |
SPXCDDM4 |
Replacement display module for RTD (4~20mA) |
|
|
SPXCDDMR |
Replacement display module for RFD (4~20mA) |
|
|
SPXCDDM4M |
Replacement display module for RTD (4~20mA), with MODBUS |
|
|
SPXCDDMRM |
Replacement display module for RFD (4~20mA), with MODBUS |
|
|
1283-1047 |
Duct mount adaptor assembly (requires 1283-1084) |
|
|
1283-1084 |
Sensepoint adaptor interface Kit (requires 1283-1047) |
|
|
7.4 Accessories |
|
|
|
Accessories |
|
|
|
Part Number |
Description |
SPXCDMTBR |
Pipe mounting bracket (inc. fixings and hex wrench set) |
|
|
SPXCDSDP |
Sunshade / deluge protection |
|
|
02000-A-1635 |
Series 2000 weather housing use with toxic Sensor |
|
|
02000-A-1645 |
Series 2000 flow housing assembly |
|
|
|
Toxic calibration kit with calibration cover, removal tool, potentiometer adjustment tool |
2106B2114
Note: Flow housing (02000-A-1645) is required and must be ordered separately.
For all XCD calibration kits and components, please consult the XCD product page or Calibration Kits and Calibration gas pages.
28
Approved Gas Detectors
Cl2, CO, H2, H2S, NH3, NO, NO2, O2, SO2
Sensepoint is a range of hazardous area certified combustible and toxic gas detectors suitable for indoor and outdoor environments. The combustible version is disposable whereas the toxic version allows users to replace the sensing element.
Certifications include
North America: cCSAus Class I Div. 2 (Toxic only)
European: ATEX
Australian: SAA
Performance approvals include
European combustible EN50054/57
European toxic pr EN45544
Casing manufactured from PPS plastic
Wiring
Combustible 3 wire mV
Toxic 2 wire 4-20 mA
Mounting thread
M20, M25, 3/4 in. NPT
Ordering information
Select gas range and thread from the following tables.
8.1 Instruments
Combustible Sensor (ATEX Only)
Part Number |
Description |
2106B1200 |
Sensepoint 0-100% LEL Flam. Sensor M20 |
2106B1201 |
Sensepoint 0-100% LEL Flam. Sensor M25 |
2106B1204 |
Sensepoint 0-100% LEL Flam. Sensor 3/4NPT |
* please refer to the manual for gas specific unit and range
Note: For a complete sensor order correct number of BARTEC J.Box 00780-A-0100 and Weather Housing 02000-A-1640
Combustible Sensor - High Temperature (150°C with 3rd Party Performance Approval)
Part Number |
Description |
2106B2310 |
Sensepoint HT Flammable Sensor (ATEX) M20 |
2106B2311 |
Sensepoint HT Flammable Sensor (ATEX) M25 |
2106B2312 |
Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT |
Note: For a complete sensor order correct number of FEEL Exe J.Box 2052D0001 and Weather Housing 00780-A-0076
Sensepoint Toxic Sensor (ATEX)Sensepoint Toxic Sensor (cCSAus Class I, Div. 2)
Part Number |
Description |
2106B1700 |
Sensepoint H2S 0-20 ppm Toxic Sensor 3/4NPT |
2106B1701 |
Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT |
2106B1702 |
Sensepoint H2S 0-100 ppm Toxic Sensor 3/4NPT |
2106B1801 |
Sensepoint H2S 0-50 ppm Toxic Sensor 3/4NPT CSA |
2106B1400 |
Sensepoint H2S 0-20 ppm Toxic Sensor M20 |
2106B1401 |
Sensepoint H2S 0-50 ppm Toxic Sensor M20 |
29
8. Sensepoint Flammable and Toxic Hazardous Area
Approved Gas Detectors
2106B1402 |
Sensepoint H2S 0-100 ppm Toxic Sensor M20 |
2106B1706 |
Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT |
2106B1707 |
Sensepoint CO 0-500 ppm Toxic Sensor 3/4NPT |
2106B1806 |
Sensepoint CO 0-200 ppm Toxic Sensor 3/4NPT CSA |
2106B1405 |
Sensepoint CO 0-100 ppm Toxic Sensor M20 |
2106B1406 |
Sensepoint CO 0-200 ppm Toxic Sensor M20 |
2106B1407 |
Sensepoint CO 0-500 ppm Toxic Sensor M20 |
2106B1711 |
Sensepoint Cl2 0-15 ppm Toxic Sensor 3/4NPT |
2106B1810 |
Sensepoint Cl2 0-5 ppm Toxic Sensor 3/4NPT CSA |
2106B1410 |
Sensepoint Cl2 0-5 ppm Toxic Sensor M20 |
2106B1411 |
Sensepoint Cl2 0-15 ppm Toxic Sensor M20 |
2106B1713 |
Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT |
2106B1714 |
Sensepoint NH3 0-1000 ppm Toxic Sensor 3/4NPT |
2106B1715 |
Sensepoint NH3 0-100 ppm Toxic Sensor 3/4NPT |
2106B1813 |
Sensepoint NH3 0-50 ppm Toxic Sensor 3/4NPT CSA |
2106B1413 |
Sensepoint NH3 0-50 ppm Toxic Sensor M20 |
2106B1414 |
Sensepoint NH3 0-1000 ppm Toxic Sensor M20 |
2106B1415 |
Sensepoint NH3 0-100 ppm Toxic Sensor M20 |
2106B1816 |
Sensepoint H2 0-1000 ppm Toxic Sensor 3/4NPT CSA |
2106B1817 |
Sensepoint H2 0-10000ppm Toxic Sensor 3/4NPT CSA |
2106B1416 |
Sensepoint H2 0-1000 ppm Toxic Sensor M20 |
2106B1417 |
Sensepoint H2 0-10000 ppm Toxic Sensor M20 |
2106B1818 |
Sensepoint NO 0-100 ppm Toxic Sensor 3/4NPT CSA |
2106B1418 |
Sensepoint NO 0-100 ppm Toxic Sensor M20 |
2106B1820 |
Sensepoint SO2 0-15 ppm Toxic Sensor 3/4NPT CSA |
2106B1420 |
Sensepoint SO2 0-15 ppm Toxic Sensor M20 |
2106B1421 |
Sensepoint SO2 0-50 ppm Toxic Sensor M20 |
2106B1822 |
Sensepoint NO2 0-10 ppm Toxic Sensor 3/4NPT CSA |
2106B1422 |
Sensepoint NO2 0-10 ppm Toxic Sensor M20 |
2106B1730 |
Sensepoint O2 25% V/V Toxic Sensor 3/4NPT |
2106B1830 |
Sensepoint 0-25 V/V O2 Toxic Sensor 3/4NPT CSA |
2106B1430 |
Sensepoint O2 25% V/V Toxic Sensor M20 |
Note: For a complete sensor order correct number of BARTEC J.Box 00780-A-0100 and Weather Housing 02000-A-1635
30