Honeywell UDC3500 Selection guide

51-51-16U-81
Issue 15
Page 1 of 3
UDC3500 Universal Digital Controller
Model Selection Guide
Instructions
Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Tables I through VI using the column below the proper arrow. A dot ( ) denotes availability.
Key Number
- - - - _ _ _ _ _ - _
KEY NUMBER - UDC3500 Single & Dual Loop Controller If Applicable
Selection Stocking P/N
Digital Controller for use with 90 to 250Vac Power + Current Output #1 DC3500 Digital Controller for use with 24Vac/dc Power + Current Output #1 DC3501
TABLE I - Specify optional Output and/or Alarms
None
TABLE II - Communications and Software Selections
0 _ _ _ 1 _ _ _ 2 _ _ _ 3 _ _ _
_ 0 _ _
_ A _ _
_ B _ _ _ C _ _ _ D _ _
_ E _ _
_ F _ _ _ G _ _
Enhanced SPP (4 Programs, 20 Segments each)
_ H _ _
Enhanced SPP + Math (4 Programs, 20 Segments each)
_ J _ _
Enhanced SPP + HealthWatch (4 Programs, 20 Segments each)
_ K _ _
Enhanced SPP + Math + HealthWatch (4 Programs, 20 Segments each)
_ L _ _
_ _ 0 _
_ _2 _
_ _ _ 0 _ _ _ C
_ _ _ _ _ _
_ _
_ _ _ _
_ _ _
_ _
IIIIIIIVV
VI
Description
Availability
Output #2
0 _
Current Output (4 to 20mA, 0 to 20 mA) (Current Output #3)
C _
Electro Mechanical Relay (5 Amp Form C)
E _
Solid State 1 Amp (Zero-Crossing Type)
A _
Open Collector transistor output
T _
Dual 2 Amp Relays (Form A) (Heat/Cool, Pos Prop, TPSC, Relays 1 & 2)
R _
Relay Outputs #3, #4
and #5
None
_ 0
Three (3) E-M Relay (5 Amp Form C)
_ E
Communications
None
Current Output #2 + (4) Digital Inputs
Current Output #2 + (4) Digital Inputs + Modbus RS-485
10 Base-T Ethernet (Modbus RTU) + (4) Digital Inputs
HealthWatch
SPP + HealthWatch (1 Program, 20 Segments)
Math + HealthWatch
SPP + Math + HealthWatch (1 Program, 20 Segments)
Enhanced
Loops of Control
Single Loop
2 Loops + Internal Cascade
Software Selections
Standard Functions, Includes Accutune
Math Option
Set Point Programming (1 Program, 20 Segments)
Set Point Programming Plus Math (1 Program, 20 Segments)
Real-Time Clock
None
Real-Time Clock (RTC)
UDC3500 Controller
New! Easy To Use UDC3500 1/4 DIN Single & Dual Loop Controller
The UDC3500 Controller packs new powerful features while retaining all the simplicity and flexibility of the industry standard UDC3300 Controller. Many new features include:
- NEMA 4X, IP66 Front Face Protection
- Built-in infrared communications port for configuring with a Pocket PC or Laptop
- PC Based Configuration Tools
- Ethernet Communications
- 20 Segment Set Point Programming
- One or Two Loops of Control
- Real Time Clock
51-51-16U-81 Issue 15 Page 2 of 3
Availability
DC
3500 3501 If Applicable
TABLE III - Input types can be changed in the field Selection Stocking P/N
1 _ _ 2 _ _ 3 _ _ _ 0 _ _ 1 _ _ 2 _
Two HLAI instead of 1 LLAI
_ 3 _ _ 5 _
b b
_ 6 _
b b
_ _0 _ _1
_ _2 Two HLAI instead of 1 LLAI _ _3 Slidewire Input for Position Prop. (Requires Dual Relay Output)
_ _4
a a
TABLE IV - Options
0 _ _ _ _ 1 _ _ _ _ _ 0 _ _ _ _ T _ _ _ _ _ 0 _ _ _ _ 1 _ _ _ _ _ 0 _ _ _ _ _ 0
TABLE V - Product Manuals
Product Information on CD - (English) 0 _ English Manual (Hard Copy) E _ French Manual (Hard Copy) F _
German Manual (Hard Copy)
G _
Italian Manual (Hard Copy) I _
Spanish Manual (Hard Copy)
S _
_ 0
_ C
TABLE VI
None 0
Note 1:
The specific range and input actuation to be calibrated to 0.05% must be specified for each input. Form F3399 Supplemental Data must be completed. This form can be downloaded from the Honeywell SalesNet site
or Global Technical Services site: >http://content.honeywell.com/ipc/faq/<
Only one range type can be calibrated for each input. All other universal ranges will remain at 0.10%.
ORDERING INSTRUCTIONS: These are provided as guidance for ordering such as those listed
1. Part numbers are provided to facilitate Distributor Stock.
2. Orders may be placed either by model selection or by part number.
3. Part numbers are shown within the model selection tables to assist with compatibility information.
4. Orders placed by model selection are systematically protected against incompatibility.
5. Compatibility assessment is the responsibility of the purchaser for orders placed by part number.
6. Items labeled as N/A are not available via the stocking program and must be ordered by model selection.
RESTRICTIONS
Table
Input 1
TC, RTD, mV, 0-5V, 1-5V
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, -1-1V, 0-10V
Input 2
None
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, -1-1V, 0-10V
Relative Humidity (Requires Input 2)
Carbon, Oxygen or Dewpoint (Requires Input 2)
Tags
None
Stainless Steel Customer ID Tag - 3 lines w/22 characters/line
Special Options
None
Custom Calibration (0.05%) For one Range Type Only (Note 1)
Input 3
None
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA
TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, -1-1V, 0-10V
Approvals
CE (Standard)
CE, UL and CSA
Restriction Letters Available Only With
Not Available With
Selection
Table
Selection
Future Options
None
None
Manuals
Certificate
None
Certificate of Conformance (F3391)
a
I
R _
b
III