Honeywell T7412E PRODUCT DATA

GENERAL
The temperature sensor is used for room temperature measurement in Excel 500 heating, ventilating and air control systems. It is suited for wall mounting and incorporates an occupancy extend button. As a passive product, this sensor is not subject to the requirements of CE.
INSTALLATION
Observe the following mounting and installation advice:
Mount these units at the inside wall of the room to be
heated or air conditioned, away from doors, windows and heat sources.
Do not mount in niches, book shelves, behind cabinets or
curtains or where it could be exposed to solar radiation.
Seal the conduit opening to avoid false temperature
measurement due to draught from the conduit.
NOTE: Use shielded wiring in areas with high EMI. Keep
15 cm (5.9’’) minimum distance between sensor lines and 230 Vac power lines.
T7412E
ROOM TEMPERATURE SENSOR
PRODUCT DATA
FEATURES
NTC-Thermistor sensing element
Sensing range 0...+40 C (+32...+104 F)
Occupancy extend push-button
LED indication
Attractive housing
SPECIFICATION
Room Temperature Sensor T7412E1027 Occ. Extend button normally-open contact LED For mode indication:
ON = 10 Vdc / 1 mA OFF < 1 Vdc
Dimensions 130 x 80 x 34 mm
(H x W x D)
(5.12 x 3.15 x 1.34”) Weight 80 g Case plastic (ABS), flame retardant
Mounting wall, surface, or European wall
Ambient operating limits 0...+50 C (+32...+122 F)
Ambient storage limits -25...+70 C (-13...+158 F)
Connections terminals for 2x1.5mm²
Protection Standards IP 30 as per EN60529 terminal
Temperature Sensor:
Sensing element NTC - Thermistor Resistance 20 kOhm at 25C Characteristic see EN0B-0476GE51 for
Sensing range 0...+40 C (+32...+104 F)
as per UL94-V0
outlet box
5...95% rh, non-condensing
5...95% rh, non-condensing
conductors
box
characteristic
® U.S. Registered Trademark EN0B-0304GE51 R0110 Copyright © 2010 Honeywell Inc. • All rights reserved
CONNECTIONS
T7412E ROOM TEMPERATURE SENSOR
1
LED
2
COM
3
4
1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10
5
6
WIRING RUN
TEMP. SENSOR
EXTEND BUTTON
T7412E
LED
MOUNTING AND DIMENSIONS
80 (3.15”)
TEMPERATURE SENSOR
OCCUPANCY EXTEND PUSH-BUTTON
COM
TEMPERATURE SENSOR
Terminals 2 and 6 internally connected.
TYPE MAX. LENGTH
For wiring length and cable type to controller, follow the wiring guidelines of the controller specification.
2
1 1
20
(0.79”)
2 X 1.5 mm2
2 X 1.5 mm2
2 X 1.5 mm2
11
(0.43”)
30 (1.18”)
60 (2.36”)
130 (5.12”)
34 (1.34”)
Fig. 1. Mounting and dimensions
Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative:
Automation and Control Solutions
Honeywell GmbH Böblinger Strasse 17 71101 Schönaich, Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com
Subject to change without notice. Printed in Germany
EN0B-0304GE51 R0110
FIVE MOUNTING HOLES WITH A DIAMETER OF 4 mm (0.16”) FOR THREE (TWO) 3.5-mm (0.14”) SCREWS MOUNTED IN POSITIONS 1 (PREFERRED) OR 2.
2
1, 2
60 (2.36”)
107 (4.21”)