The Honeywell trademark is used by Kaz, Inc. under license from Honeywell Intellectual Properties, Inc.
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 2
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS
BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be
followed to reduce the risk of fire, electric shock, and injury to persons,
including the following:
1.Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly
on an uneven surface.
2.Place this humidifier in an area where it is not accessible to children.
3.Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
4.Do not use the humidifier outdoors.
5.Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be
damaged,
for repair.
6.This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock,
this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the
outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
this safety feature.
7.To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from
the wall outlet. Never pull by the cord.
8.A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the
plug. Contact a qualified electrician to replace loose or worn outlet.
9.The humidifier should always be unplugged and emptied when not in operation or while being
serviced or cleaned.
10. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the
humidifier before moving.
11. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean
the humidifier in any manner other than as instructed in this manual.
12. Do not direct moisture flow directly at individuals, walls or furniture.
13. When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation,
as excessive humidity can cause condensa
urn the humidifier OFF if you notice moisture on the inside of your windo
14. T
reading use a hygrometer
ordering one from the manufacturer.
DO NOT USE and return the humidifier to the manufacturer under the warranty agreement
DO NOT attempt to defeat
tion stains on walls.
or proper humidity
F
ws.
which is available in many hardware and department stores, or by
,
2
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 3
Introduction
HOW DOES IT WORK?
™
COOL MOISTURE SYSTEM:
Dry air is pulled through the humidifier and the QuietCare™fan blows out invisible, moisture-balanced air.
Unwanted minerals and bacteria from the water are trapped inside the filter.When the unit is running you
WILL NOT see or feel a “mist”.You will know your humidifier is putting moisture into the air as you watch
the water level in your tank decrease throughout the day.
COMPLETE
Your new QuietCare™humidifier has double Protec™Product Protection with the exclusive Protec
Cleaning Cartridge and Protec™treated filter.
Protec™Cleaning Cartridge: Your humidifier has been designed with the Protec™Cleaning Cartridge.
This unique cartridge features an advanced patented media which continually inhibits the growth of odorcausing bacteria and mold in the cartridge as well as prevents the buildup of minerals in your humidifier.
In addition, the Protec
Protec™Antimicrobial Treated Filter: Your filter has been treated with Protec™antimicrobial which helps
prevent surface growth and migration of mold, mildew, algae, fungus and odor-causing bacteria in the filter
for its life – approximately 1-3 months**. Keep in mind, depending on your water quality, mineral deposits
can still clog or discolor the filter, affecting its life and that of the humidifier.
Air Washing Technology: Unique air washing system which helps “wash the air as it humidifies.”
The unique pre-filter in combination with an ionizer helps capture dust, dirt, and pollen while freshening
the air. (HCM-631 Series and HCM-632 Series only)
Your humidifier is made up of these parts:
™
cartridge provides peace of mind that the mist is fresh and clean*.
™
PROTECTION
™
Motor Housing
Water Tank
Protec™Cleaning
Cartridge Holder
Fill Cap
*The Protec Cleaning Cartridge is antimicrobially treated to help prevent the growth of mold, fungus, algae and odor-causing bacteria on the cartridge only. It is
not intended nor does it act to provide any pesticidal effect to mold, fungus, algae or odor-causing bacteria in the humidifier or humidifier water.
**The antimicrobial agent contained in this product is intended to prolong filter life only by inhibiting the growth of unsightly mold, mildew and algae, as well as
controlling odor from odor-causing bacteria. The antimicrobial filter does not protect users or others against bacteria, viruses, germs or other disease-causing
organisms. Always follow the humidifier manufacturer's instructions regarding cleaning, maintenance and servicing of your humidifier.
Filter
Base
3
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 4
Set-Up
NOTE: We recommend that the humidifier be disinfected prior to first use.
Please see
Select a firm, level, flat location - at least six inches (15 cm) from any wall for proper air flow (Fig. 1). Place
the humidifier on a water-resistant surface, as water can damage furniture and some flooring.
Kaz will not accept responsibility for property damage caused by water spillage.
CLEANING INSTRUCTIONS.
Filling
• Remove the water tank by grasping handle and pulling straight up. Set
aside (Fig. 1).
• Lift up on the motor housing to remove and set aside (Fig. 2). Remove the
filter from the base before filling the unit with water. Soak filter in a sink
full of cool water to help reduce mineral buildup and place back in the
humidifier while wet.
help extend the life of your filter, repeat this step each time you fill your
humidifier.
• Turn the Water Tank upside down so that the Fill Cap is facing up;
unscrew the Fill Cap by turning it counter-clockwise and set aside.
• Fill the Water Tank with COOL tap water (Fig. 3). Distilled water is not
necessary but should be considered in hard water areas to prevent
mineral build-up.
humidifier.
• Replace the fill cap by turning it clockwise .
Turn the Water Tank right-side up.
NOTE: When carrying the filled Water Tank please use the handle and
place your other hand under the tank for additional support.
• Place the Motor Housing back into the base.
• Position the Water Tank in the humidifier and push into place. Some water
will empty into the base.
• Once the filled tank has been positioned, do not attempt to move the
humidifier. To avoid leaking, you should never move the humidifier while
filled with water.
CAUTION: DO NOT POUR WATER INTO THE GRILLE IN THE
FRONT OF THE HUMIDIFIER.
HUMIDIFIER OR C
DO NOT SQUEEZE OR WRING OUT THE FILTER. To
DO NOT USE HOT WATER. Doing so may damage the
DO NOT OVER-TIGHTEN.
AMAGE THE
DOING SO MA
AUSE PERSONAL INJUR
Y D
Y.
Fig. 1
WALL
6"
Fig. 2
Fig. 3
4
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 5
Manual Control Operation (Model HCM-630 Series and HCM-640BW)
POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH
WET HANDS AS AN ELECTRICAL SHOCK COULD
OCCUR.
• With the power switch in the OFF position, plug the filled
humidifier into a polarized 120V outlet. DO NOT FORCE THE
POLARIZED PLUG INTO THE OUTLET; it will only fit one way.
OUTPUT / FAN SPEED CONTROL
• Set the fan speed to the desired position (Fig. 4).
HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)
• Continuous Mode: Your unit will run continuously at your
selected speed until you shut it off or it runs out of water.
NOTE: Turn the humidifier OFF if the humidity level feels too moist or you notice condensation forming on
the walls and/or windows.
Fig. 4
Fan
Speed
K
nob
Power
Light
(Illuminated)
ADVANCED MIST™HUMIDISTAT
The Advanced Mist™Humidistat allows you to adjust and select the humidity level to your personal
preference. Your humidifier will turn on and off throughout the day and night to maintain the desired
humidity level you have selected.
Desired
Humidity
Light
Humidistat
Knob
HOW TO SET THE HUMIDISTAT
First, turn the humidifier on and select your output/speed level.
Set the Advanced Mist
™
Humidistat on High by turning the knob
Fig. 5
clockwise to the end (Fig. 4).
• Let the humidifier run on high for a least one hour
your room has reached a comfortable humidity level.
• At this point, slowly turn your Humidistat knob counter-
or until
Power
Light
(Illuminated)
Desired
Humidity
Light
(Illuminated)
clockwise until the humidifier shuts off and the Desired
Humidity light illuminates (Fig. 5).
• Now that your Humidistat knob is set, the humidifier will
automatically turn back on when your room drops below
your comfort setting and will
automatically turn off again
when the setting is reached.
NOTE: If the humidifier fan will not start or restart when you select a fan speed, the Advanced Mist
™
Humidistat may be set too low. Turn the dial clockwise to the end (Fig. 4). The Desired Humidity light
ve
will turn Off when the unit is producing moisture.
reached optimal humidity
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH
WET HANDS AS AN ELECTRICAL SHOCK COULD
OCCUR.
• With the power OFF, plug the filled humidifier into a polarized
120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE
OUTLET; it will only fit one way.
Fig. 6
Humidistat
Control
STEP 1: POWER
• Press the Power button to start the humidifier. Your humidifier
will automatically start on High power, Continuous Mode (Fig. 6).
• To turn your humidifier OFF simply press the Power button
again.
STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:
HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)
• Push the up button (
down button (
+) to increase output level and push the
-) to decrease output level. The LED's will
illuminate to reflect which speed you have selected (Fig. 7).
STEP 3: SET HUMIDITY
• Set your desired humidity anywhere between 35% and 55%.
• Push the up button (
the down button (
will illuminate to reflect which desired humidity level you have
selected (Fig. 8).
For example: If you set your humidity at 40%, the 35% and
40% LED’s will be illuminated.
• Once you have set your desired humidity, the unit will operate
under this setting until the unit is turned off or your selected
humidity is reached.
• When the desired room humidity has been reached the fan will
automatically shut off. (The humidity LED's will remain
illuminated)
• The fan will turn back on when your room decreases beyond
your set level.
NOTE: Your room humidity can often fluctuate. It is normal for
your unit to turn itself on and off throughout the day as it is
monitoring your changing environment.
To go back to Continuous Mode,
on and select your desired output setting (see Step 2).
+) to increase desired humidity and push
-) to decrease desired humidity. The LED's
turn your unit off and then back
Fig. 7
Fig. 8
Power
Button
Fan Speed
Control
6
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 7
Digital EasySet™Control Operation (Model HCM-650)
POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET
HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.
• With the power OFF, plug the filled humidifier into a polarized
120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE
OUTLET; it will only fit one way.
STEP 1: POWER
• Press the Power button to start the humidifier. Your humidifier
will automatically start on High power, Continuous Mode. The
display will be illuminated and will reflect the current room
humidity (Fig. 9).
• To turn your humidifier OFF simply press the Power button again.
Continuous Mode: Your unit will run continuously at your selected
output level until you shut it off or it runs out of water.
STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:
HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)
• To change your fan speed press the fan speed button () up or
down (Fig. 10).
• Once you have selected your desired speed the display will go
back to showing the current room humidity after 3 seconds.
NOTE: If you wish to change or check your output/speed setting
simply press the fan speed button () once and it will show you
your setting. If you would like to change it, continue to push the
button up or down until you have reached your desired setting.
Again, after 3 seconds the display will revert to showing the current
room humidity.
Fig. 9
Desired
Humidity
Light
Fan Speed
Control
Fig. 10
Fig. 11
Humidistat
Control
Timer
Control
STEP 3: TIMER CONTROL
• You can set your timer for up to 18 hours. This function should
only be used if you desire that the humidifier be automatically
shut off after a certain period of time.
• Press the Timer button () up or down to set how many hours
you would like the humidifier to run (Fig. 11).
• When the display indicates your desired time, wait 3 seconds.
• After 3 seconds, your desired time is set and the display will
revert back to showing the current room humidity.
NOTE: If you wish to change your timer setting or check to see how much time is left, simply press the
Timer button () once and it will sho
continue to push the button up or down until you have reached your desired time. Again, after 3 seconds
the display will revert to showing the current room humidity. If you set a timer but no longer wish to have
it set, turn the unit off and then repea
w you the time left. If you want to change the time remaining,
t steps 1 and 2.
7
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 8
Digital EasySet™Control Operation (Model HCM-650)
STEP 4: SET HUMIDITY
• You can set your desired humidity in 1% increments anywhere
from 25% to 65%.
• To set your desired humidity, press the humidity button ()
up or down (Fig. 12).
• When the display indicates your desired humidity setting wait 3
seconds.
• After 3 seconds your desired humidity is set and the display
will revert back to showing the current room humidity.
NOTE: If you wish to change your humidity setting or check to
see what you set, simply press the humidity button once and it
will show you the set humidity. If you want to change it,
continue to push the button up or down until you have reached
your new desired humidity.Again, after 3 seconds the display
will revert to showing the current room humidity.
• Once you have set your humidity the unit will operate under
this setting until the unit is turned off or your selected humidity
is reached.
• When your desired room humidity has been reached the fan
will shut off and the house icon ( ) on the top of your display
will illuminate (Fig. 13). It will stay illuminated until your desired
humidity decreases at which time the fan will turn back on.
NOTE: Your room humidity can often fluctuate. It is normal for your
unit to turn itself on and off throughout the day as it is monitoring
your changing environment.
Fig. 12
Fig. 13
Protec™Cleaning Cartridge
The Protec™Cleaning Cartridge will last 30 days or longer, depending on your usage. To install or replace
your cartridge, simply remove the holder on the inside of your tank cap by turning it counter-clockwise .
Replace the cartridge holder by by turning it clockwise (Fig. 14 & Fig. 15).
Fig. 14
Tank Cap
Cartridge
Holder
Protec
Cleaning
Cartridge
™
8
Fig. 15
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 9
Cleaning
Your Protec
™
Cleaning Cartridge helps reduce mineral build-up in your humidifier and will help extend the
life of your filter. However, you should still continue to clean your humidifier regularly as needed.
Cleaning involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the
proper order to avoid harmful chemical interactions.
• First, turn off and unplug the humidifier.
• Remove the Water Tank and Motor Housing.
Remove the filter from the Base.
•
• Empty any water from the Base.
NOTE: REMOVE FILTER AND PROTEC™CLEANING CARTRIDGE BEFORE CLEANING.
Failure to remove filter during cleaning will destroy the filter.
STEP ONE:
SCALE REMOVAL
BASE
1. Fill the Base with:
• 1 cup (8 ozs.) of undiluted white vinegar
2. Let solution stand for 20 minutes.
3. With the vinegar in the Base, clean all interior
surfaces with a soft cloth or brush to help
remove scales.
WATER TANK/BASE
1. Fill the Water Tank with:
• 1 teaspoon of household bleach
• 1 gallon of water
Pour some of this solution into the Base.
2. Let solution stand for 20 minutes. Make sure to
cover all surfaces.
STEP TWO:
DISINFECTING
and
4. Rinse the Base thoroughly with water to
remove scale and cleaning solution.
3. Rinse with water until the smell of bleach is
gone.
NOTES:
• The use of other water treatment products and chemicals may cause deterioration of the filter or
damage the humidifier, thereby hindering the humidifier's effectiveness.
• If you are experiencing more buildup than when you first purchased your humidifier, you may need to
replace your Protec
™
Cleaning Cartridge. Changing your cartridge every 30 days will provide continuous
protection.
9
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 10
End-of-Season Care and Storage
• Follow the CLEANING instructions when the humidifier will not be used for at least one week or more,
or at the end of the season.
• At the end of the season, remove and throw away the filter and Protec™Cleaning Cartridge; do not store
with a used filter.
• Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
™
• Before next use, remember to clean your humidifier, install a new filter and new Protec
Call us toll-free at: 1-800-477-0457
E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Purchase replacement filter part number
HAC-504AW and Protec™Cleaning Cartridge part number
PC-1 (1 pack) or PC-2 (2 pack)
Electrical Ratings
The Honeywell QuietCare™Series models are rated at 120V, 60 Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE
OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING
YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR
PERSONAL INJURY.
10
QuietCare_OM_Rev2.qxd 10/25/06 2:11 PM Page 11
Troubleshooting
Q: I hear the fan turning, but I don’t see any mist. Is my humidifier operating
properly?
Dry air is pulled through the system and a fan disperses invisible, moisture balanced air. There is no
A:
“mist” emitted. When operating normally you will feel only cool air coming from the unit. Monitor the
water level in your Tank/ Base. If you notice a decrease in the Water Tank over 24 hours then the unit
is operating normally.
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice the
water level in the tank decreasing.
A: First, check the filter to ensure it is wet. If the pad appears dry, remove it from the Base and gently
rinse under cool water. Reposition wet filter in the Base. You may also want to note the current
moisture level in your home. If the humidity level is over 60% the unit will not put out much moisture
as your air is already saturated.
Q: The humidifier is not running (the fan is not even spinning), but all (or some) of the lights are
on. (Model HCM-630)
A: If the Desired Humidity light is ON: The Advanced Mist™Humidistat knob may be set too low. Moving
the knob clockwise to the end should restart the unit.
Q: The Advanced Mist™Humidistat knob was set according to the manual, but the humidifier
never seems to turn back on. Is something wrong? (Model HCM-630)
The Humidistat knob may be set too low. Moving the Humidistat knob to the end clockwise should
A:
restart the unit.
Q: The Advanced Mist™Humidistat knob was set according to the manual, but the humidifier
never seems to turn off. Is something wrong? (Model HCM-630)
The Humidistat knob may be set too high. Reset the Advanced Mist™Humidistat knob following the
A:
instructions under FEATURES.
Q: My filter has turned light brown and rust colored. Do I need a new filter?
Probably not. Since your filter has been made with Protec™antimicrobial the change in color indicates
A:
only a mineral deposit. Soak filter in a sink full of cool water to help break up deposits. The
discoloration may remain but will not affect the humidifier’s performance.
Q: My humidifier doesn’t appear to be as clean as when I first purchased and/or I’m smelling an
unpleasant odor. What should I do?
You probably need to replace your Protec™Cleaning Cartridge. This cartridge helps your humidifier
A:
stay cleaner, longer and helps freshen the mist. If you have been using your humidifier regularly for
over 30 days replace the Protec™cartridge and follo
w the cleaning instructions.
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.