Honeywell CO60PM User Manual

Portable Evaporative Air Cooler
for Outdoor, Indoor & Commercial Use
Enfriador de aire portátil por evaporación
Ideal para Uso Externo, Interno y Comercial
OFF
ON
3
0
2
1
OFF
ON
SWING
SPEED
COOL
For product inquiries or support, visit www.honeywellaircoolers.com
Para consultas sobre productos o soporte técnico visite: www.honeywellaircoolers.com
Customer Support : 1-800-474-2147 Centro de servicios al cliente: 1-800-474-2147
OWNER’S MANUAL
Read and save these instructions before use
MANUAL DEL USUARIO
Lea y guarde estas instrucciones antes de usar
Model: CO60PM
Modelo: CO60PM
Voltage rating: 120 Volt AC, 60Hz
Potencia: 220 Watt
Voltage: 120 Volt AC, 60Hz
Made in P.R.C.
Fabricado en China
QUICK START GUIDE
1
2
3
Fill with water and plug into a standard power outlet.
Note: Please make sure the household power voltage matches the product specifications.
Place near an open door or window.
Note : Evaporative air cooler requires cross ventilation.
Turn ON and enjoy the cooling breeze.
Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX
Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.
SECTION
1. THANK YOU .........................................................................................................
2. USER TIPS ...........................................................................................................
3. SAFETY ................................................................................................................
4. PARTS DESCRIPTION .........................................................................................
5. USE & OPERATION .............................................................................................
Control Panel ....................................................................................................
Control Knobs ..... ...............................................................................................
Filling with Water ...............................................................................................
6. CLEANING & MAINTENANCE .............................................................................
7. TROUBLESHOOTING GUIDE .............................................................................
8. TECHNICAL SPECIFICATIONS ...........................................................................
9. ELECTRICAL WIRING DIAGRAM ........................................................................
10. SERVICE AND WARRANTY ........ ........................................................................
PAGE
2 3 5 8 9
9 10 11
13 15 16 17 18
1
THANK YOU
Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler.
Cooler Location – Indoors (Important - Please Read!)
Place the cooler in front of an open door or window. Ensure that there is adequate cross­ventilation in the room by leaving a door or window open opposite the cooler. Following these guidelines will ensure your cooler will work as effectively as possible.
Not an Air Conditioner (Important - Please Read!)
The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner.
2
USER TIPS
Energy Efficient, No Compressor
Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively.
Honeycomb Cooling Media
Cool and humid air
Water
Evaporative Air Cooling Mechanism
Pump
Warm and dry air
3
USER TIPS
Indoor Use
The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low.
The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow. The evaporative air cooler works best when placed near an open window, so that outside air is drawn into the evaporative air cooler, circulates in the room, then exits via the door. The maximum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler.
Room with open windows & door (RECOMMENDED)
The evaporative air cooler can also be used to humidify dry air during cool weather. To be used for humidification the windows and doors should be closed to allow the humidified air to accumulate.
Room with closed windows & door (NOT-RECOMMENDED)
Outdoor Use
Unit should be placed a minimum 10 inches away from any wall.
NOTE
When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use.
4
OFF
COOL
ON
OFF
SWING
ON
0
3
2
1
Read and Save These Instructions:
When using electrical appliances, basic safety precautions should always be followed:
Your cooler runs on 120 Volt AC, 60 Hz current. Check the
• household voltage to ensure it matches the appliance's rate specification. Before operating the product remove it from its packaging
• and check that it is in good condition. DO NOT operate any product with a damaged cord or plug.
• We recommend not using an extension cord with this appli­ance. DO NOT run power cord under carpeting, or cover it with
• rugs or runners. Keep the cord away from areas where it may be tripped over. Always unplug the product before refilling the water tank.
• Always unplug the appliance from the power source before
• cleaning, servicing or relocating the unit. Remove the power cord from the electrical receptacle by
• grasping and pulling on the power cord plug-end only, never pull the cord. DO NOT use the product in areas where gasoline, paint or
• other flammable goods and objects are stored. When using the COOL setting, check the water tank to
• ensure that it is full. Operation of this cooler on the COOL
WATER LEVEL INDICATOR
setting with an empty tank may result in damage to the water pump. Warning: To reduce the risk of fire or electric shock, do not use this appliance with any solid-
• state speed control device.
120V - 60 Hz
SHOCK HAZARD
MAX
MIN
SAFETY
5
OFF
COOL
ON
OFF
SWING
ON
0
1
2
3
SAFETY
DO NOT attempt to repair or adjust any electrical or mechan­ical functions of the cooler, as this may void the warranty.
DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. DO NOT insert or allow objects to enter any ventilation or
exhaust opening as this may damage the product and could cause an electrical shock or fire. DO NOT operate with the Honeycomb media removed as this
will overload and damage the motor.
DO NOT leave the operating appliance unattended for any extended period of time.
DO NOT let children play with this appliance, packaging or plastic bags. If the unit is damaged or if it malfunctions, do not continue to
use it. Refer to the Troubleshooting Guide (page 15) and contact the service center. Place the unit on a level floor.
This product is not intended for use in wet or damp locations.
DO NOT use in bathrooms. Never locate the product where it may fall into a bathtub or other water container. Store in a dry area when not in use.
This appliance is not intended for use by persons (including
children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Always grip the side handles to move the cooler.
FLOOR LEVEL
6
SAFETY
Use Only on GFCI Protected Receptacles.
Power cords have to be contained. If they must run along the ground, make sure every inch of them is secured so they will not be tripped over. The wiring and connections must be waterproof. Be sure the connections (to the air cooler)
never get wet. Your unit is waterproof, but everything attached to it must be waterproof, too. Set up your unit so it cannot be tripped over or wobble loose. It must rest on a solid
support.
7
PARTS DESCRIPTION
16
14
17
13
12
1 Water Inlet and Ice Loading Compartment 2 Handle 3 Left Honeycomb Panel 4 Lever for Horizontal Louvers 5 Water Tank 6 Casters 7 Horizontal Louvers 8 Water Level Indicator
9
OFF
ON
3
0
15
2
1
OFF
ON
SWING
SPEED
COOL
10
8
11
7
9 Control Panel 10 Right Honeycomb Panel 11 Continuous Water Supply Connection 12 Drain Plug 13 Backside Honeycomb Panel 14 Power Cord & Plug 15 Rear Grill Removal Screws 16 Water Fill Door 17 Honeycomb Cooling Media
1
2
3
4
5
6
8
CONTROL PANEL
OFF ON
USE & OPERATION
0
3
OFF ON
2
1
COOL
SPEED
SWING
9
USE & OPERATION
CONTROL KNOBS
SPEED / ON - OFF Connect to the power supply and turn the Speed knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 High. To switch OFF the unit turn the Speed know to 0.
COOL To begin cooling the desired area turn the COOL switch ON. The water pump will operate. You can feel the cooler air after the Honeycomb media is completely wet.
0
SPEED
OFF ON
COOL
3
2
1
SWING Turn the SWING switch ON. The louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow.
Horizontal Louvers Manually adjust the horizontal louvers to change vertical airflow.
10
OFF ON
SWING
Loading...