Honeywell CM901 PRODUCT SPECIFICATION SHEET

Page 1
CM901
PROGRAMMABLE THERMOSTAT
PRODUCT SPECIFICATION SHEET
The CM901 thermostat is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments.
It can be used as part of a system in conjunction with combi­boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<8A).
The CM901 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy.
The CM901 extra large LCD display, dynamic text display, button layout based on the same simple programming philosophy used on our acclaimed CM60 products and the introduction of an ‘OK’ button makes it easier to install and more user friendly.
The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to
FEATURES
Attractive, slim, ultra-modern styling makes it ideal for
location in any type of home.
24 hour heating program.
A dynamic text display on the LCD that gives enhanced
feedback to the user / installer.
Up to 6 daily independent time and temperature level
changes let you set 6 time and temperatures pairs to suit your lifestyle.
LCD Backlighting to illuminate the display for easier viewing
in low light conditions.
Temporary programmed temperature override to override
the programmed temperature till the next switch point.
Holiday button that provides energy savings by reducing
to a constant temperature from 1 to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return.
Room Temperature Enquiry.
EEPROM memory holds the user program indefinitely.
OFF position has an integral frost protection setting at
minimum 5°C (installer adjustable) so that pipes in the house will never freeze in winter.
24...230V 8A resistive, 3A inductive SPDT relay provides
compatibility with most domestic central heating systems reducing the need to stock many different models.
Battery powered by 2 x AA size (LR6) alkaline cells.
Minimum battery life of 2 years with low battery warning
indicator.
Built-in default heating program.
Automatic Summer / Winter time change adjusts the time
automatically to daylight saving time.
Telephone interface can be fitted to allow remote switching
between program modes and a fixed set-point.
Surface or wall-box mounting options with trunking guides
and wiring breakouts to simplify installation.
No installer links or special installer switches on the back of
the unit mean no adjustment is required for combi-boilers and most domestic central heating systems.
User Set-Up Mode allows extra functions to be set at the
discretion of the user:
AM-PM or 24hr time display.
Resetting the heating profile to factory default.
Enable / disable of Auto Summer / Winter time change.
Languages selection of the user interface (on selected
models only).
Installer Set-Up Mode allows extra functions to be set at the
discretion of the installer to match the consumers applications and needs:
Optimisation.
Pump Exercise.
Upper / Lower Set point Limit Adjust.
Temperature offset.
Minimum ON time.
Cycle rate.
Heat / Cool Operation.
Proportional Band Width.
Diagnostic Mode to assist in faultfinding.
EN0H 8546 UK07 R3 09/06
Page 2
CONTROLS/DISPLAY LAYOUT
CM901 CHRONOTHERM
PRODUCT LAYOUT:
1. Day & Date Display
2. Time Display
3. Dynamic Text Display (DTD)
4. Burner On Indicator
5. Battery Low Indicator
6. Temperature Display
7. Temperature Change Buttons
8. Information Enquiry Button
9. Slider Switch
10. Green OK Button
11. Program Buttons
12. Battery Cover
13. Battery Compartment
14. Holiday Button
15. Time Change Buttons
SPECIFICATIONS
Batteries : 2 x 1.5 V IEC LR6 (AA) Alkaline cells
Battery life : Minimum 2 years
Battery replacement
Switch type : SPDT (potential free)
Electrical rating : 230 V~, 50...60 Hz, 0.5 A to 8 A resistive
Time display : 24 hour or 12 hour AM/PM format
Time keeping accuracy
Program : 6 daily time and temperature level
Time setting resolution
Sensing element : 100K (@ 25 oC ) NTC thermistor
Temperature setting range
: Program retained in EEPROM
0.5 A to 3 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 8 A resistive
0.5 A to 3 A inductive (0.6 pf)
: Typically better than 10 minutes per year
changes
: Time of day - 1 minute
Program - 10 minute steps
: Program : 5 to 35oC in 0.5 oC steps Frost : 5
o
C to 21 oC). Frost protection does not
(5
o
C or equal to lower limit
work in cooling mode.
Temperature control accuracy
Room
: ±0.5 K (nominal) @ 20oC, 50% load
3 K Δ/hour
o
: From 0
C to 50 oC Temperature display range
Control form : P + I (Proportional + Integral)
Minimum ON time
: 10% of cycle time (min one minute),
adjustable to 2 to 5 min (see installer set up)
Cycle rate : Selectable by application (see installer
set up)
Wiring : Terminal block capable of accepting
wires up to 2.5 mm
2
Wire access : Mains wiring – rear right.
Low voltage wiring – rear right.
Dimensions : 133 x 89 x 26 mm (w x h x d)
133 x 175 x 26 mm (w x h x d) (flap open)
Environmental : Operating temperature range 0 to 40oC
Shipping and storage temperature range
-20 to 55
o
C
Humidity range 10 to 90% rh, non-
condensing
Approvals : Designed to meet European EN
approvals EN60730-1(Nov 2000), EN55014-1 (1997), EN55014-2 (2000)
EN0H 8546 UK07 R3 09/06
Page 3
INSTALLER SET-UP
To enter the installer set-up mode:
a) Move the slider switch to the OFF position.
b) Press and hold the INFO i button and the two program
buttons ‘< >’ together.
c) The unit will display the first parameter of installer
parameter group category 1 (from n.1 to n.19).
d) Press the TEMP
setting. The display will flash indicating that a change has been made.
e) Press the green OK button to confirm this change and the
display will stop flashing.
f) Press the
+ to go to the next parameter.
g) Press the program button > to go to category 2 in the
Installer mode (from n.1 to n.5).
h) To exit the installer mode, move the slider switch to the
AUTO or MAN positions.
or buttons to change the factory
Abbreviated Set-Up Description
e.g. Cl = Clock Format
Installer Set-up Number
(Press + or - to change)
e.g. 1 = Clock Format
CM901 CHRONOTHERM
Factory Setting or New Choice
Press TEMP or to change
e.g. 12 = AM/PM Format
24 = 24hr Format
In Installer set-up we can:
Set-up specific applications
Enable special features
Establish support for optional accessories
Specific Applications Setting What do you need to change?
Heating Gas Boilers
(<30KW)
Oil Boiler 3 4 1. Set Minimum ON Time to 4 minutes.
Thermal Actuator 12 1 Set Cycle/Hour to 12.
Zone valve 6 1 No action required.
Electric heating (for applications <8A)
Air conditioning
Heat Pump/ Air conditioner
Fan coil 6 1 No action required.
Cycle/ Hour
Minimum ON time
(in minutes)
6 1 No action required
12 1 1. Configure the thermostat for electric heating (set parameter n.3,
3 4 1. Set Minimum ON Time to 4 minutes.
Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2
in the installer set-up mode.
b. To change Minimum ON Time, please go to parameter n. 1,
category 2 in the installer set-up mode.
2. Set Cycle/Hour to 3.
category 2 in the installer set up mode to 1).
2. Set Cycle/Hour to 12.
1. Configure the thermostat to allow switching between heating and cooling modes (set parameter n.4, category 2 in the installer set-up mode to 1)
2. Set the thermostat accordingly to the required mode of operation (heating or cooling) by pressing the TEMP
buttons together for 5 seconds.
as required.
2. Set Cycle/Hour to 3.
Brief Description of the Parameter Function.
or
Modify the cooling program
3 EN0H 8546 UK07 R3 09/06
Page 4
CM901 CHRONOTHERM
Special Features Description What to do if we wish this
feature
Optimisation (Variable Start Time)
Adaptive Intelligence recovery TM
The thermostat will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period e.g. Time 7:00, Temp 21
o
C. The thermostat will monitor the accuracy of the start up and use this information to modify the calculation for the following day by changing the ramp rate (initial 3 K/hr) .The system will restrict the start time to a max of 2 hours. Note: Optimisation will not work in cooling mode.
Set parameter n.8, category 1 in the installer set-up mode to 1.
AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n.1, category 1 in the
installer set -up mode to 12.
Pump exercise When enabled the Pump Exercise will switch the relay
on for 1 minute at 12:00 if the relay has not been
Set parameter n.5, category 2 in the installer set -up mode to 1.
switched on since 12:00 the previous day. While in Holiday mode the Pump Exercise feature, if
enabled, will operate.
Upper Temperature Limit The normal upper temperature limit of 35 oC can be
reduced down to 21
o
C to save the homeowner energy.
Useful if the homeowner rents to tenants.
Lower Temperature Limit The normal lower temperature limit of 5 oC can be
increased up to 21
o
C to protect the inhabitants from
cold. Useful if the inhabitants include the elderly,
Set parameter n.6, category 1 in the installer set -up mode to the desired limit.
Set parameter n.7, category 1 in the installer set -up mode to the desired limit.
children or disabled.
Temperature Offset If the thermostat is located in a hot/cold location and
cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3
o
C.
Set parameter n.12, category 1 in the installer set -up mode to the desired
offset value. Useful if the homeowner wants the reading to match another appliance temperature display.
Proportional Band Width Can be adjusted up to 3 oC (default is 1.5 oC) to provide
better temperature control (less overshoot). Useful for:
Set parameter n.13, category 1 in the
installer set -up mode to the desired
value.
a. Well insulated homes with over-sized heating
systems.
b. Air systems with fast response.
Optional Accessories
Outside Temperature Sensor (F42010971 001)
Description What to do if we wish this
feature
An Outside Temperature Sensor can be fitted, allowing the homeowner to display the outside temperate on the thermostat display by pressing the INFO
i button. The
thermostat will read the outside temperature every 10 minutes. Outside temperature display range is from -30
o
C to +45 oC. The sensor can be connected up to 50
1. Fit the sensor (instructions included in the sensor package).
2. Set parameter n. 10, category 1 in the installer set-up mode to 1.
meters from the unit.
Remote Temperature Sensor (F42010972 001)
A Remote Temperature Sensor can be fitted, allowing the thermostat to control the temperature from another room or space where it is inconvenient to locate the thermostat. It will read the remote sensor every 1 minute. The sensor can be connected up to 50 meters
1. Fit the sensor (instructions
included in the sensor package).
2. Set parameter n. 10, category 1 in
the installer set-up mode to 2.
from the unit. Useful for commercial premises where the public may tamper with the product.
EN0H 8546 UK07 R3 09/06 4
Page 5
CM901 CHRONOTHERM
Parameter Installer Set-
Up Number / Abbreviation (Press + or – keys to select)
Display Description Display/Setting Description
Category 1: Thermostat Parameters
Factory Setting
Optional Setting
Installer Set­Up Category
(Press PROG keys ‘< or >’ to select)
AM-PM / 24hr
1:Cl 24 24 hr clock display 12 12 hr AM / PM clock display 1
Display
RESET Time / Temperature Program
2:rP 1 Time / Temperature
profile set to factory default Changes to 0 when
0
1
Time / Temperature are as programmed To restore the factory
profile set to 1 one of the time/temp profiles are changed
Automatic Summer/Winter Time Change
3:tC 1 Automatic
Summer/Winter Time Change Enabled
Backlight Display 5:bL 1 Backlight Display
Enabled
Upper Temperature Limit
Lower Temperature Limit
6:uL 35 35°C Upper Temp.
Limit
7:LL 5 5°C Lower Temp.
Limit
0 Automatic
Summer/Winter Time
Change Disabled
0 Backlight Display
Disabled
21 to 34 21°C to 34°C
adjustment in 1°C steps
6 to 21 6°C to 21°C adjustment
in 1°C steps
Optimisation 8:0P 0 Optimisation disabled 1 Optimisation enabled 1
Remote Control
9:tS 0 Disabled 1 Enabled 1 Setpoint (e.g. via telephone module)
Second Temperature Sensor
10:SS 0 No sensor fitted 1, 2 1 - Outside Temperature
Sensor fitted 2 - Remote Temp. Sensor fitted
1
1
1
1
1
1
Temperature Offset
Proportional Band Width
12:tO 0 No offset -3 to +3 -3°C to +3°C adjustment
in 0.1°C steps
13:Pb 1.5 1.5°C Proportional
Band
1.6 to 3.0 1.6°C to 3.0°C adjustment in 0.1°C
1
1
steps
Reset Parameters to Factory Defaults
19:FS 1 All settings held are
the factory defaults. Changes to 0 when one of the parameter
0
Settings are as modified above
1
To restore the factory profile set to 1
1
values are changed
‘Category 2: System Parameters (You must press the ‘>’ program key to enter this section)
Minimum boiler ON Time
1:Ot 1 1 minute minimum ON
time
2 to 5 2 - 2 minutes
3 - 3 minutes
2
4 - 4 minutes 5 - 5 minutes
Cycle Rate 2:Cr 6 6 cycles per hour
(cph) for gas boilers, zone valves and fan-
3, 9, 12 3 - 3 cph
9 - 9cph 12 - 12 cph
2
coil
Electric Heat
3:Eh 0 Applications < 3A 1 Applications 3 - 5A 2
Heat / Cool
4:HC 0 Disabled 1 Enabled 2
Change
EN0H 8546 UK07 R3 09/06 5
Page 6
DIMENSIONS
INSTALLATION
CM901 CHRONOTHERM
LOCATION
The CM901 thermostat is the control element of the heating / cooling system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall 1.5 metres above the floor level. Do not position the CM901 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight.
MOUNTING
The CM901 thermostat can be mounted directly on the wall surface or on an electrical wall-box.
WIRING
The CM901 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.E.E. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 8 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles).
IMPORTANT
1. The installer must be a trained service engineer
2. Disconnect the power supply before beginning installation
EN0H 8546 UK07 R3 09/06 6
Page 7
WIRING
CM901 CHRONOTHERM
ORDERING SPECIFICATION
Description Model Logo Literature Availability Spec Sheet
1-day programmable thermostat
1-day programmable thermostat
1-day programmable thermostat
1-day programmable thermostat
1-day programmable thermostat
Description Model Logo Literature Availability Spec Sheet
CM900 Remote Temp Sensor
CM900 Outdoor Temp Sensor
CM900 Telephone Interface
Terminal Block
Honeywell Control Systems Limited http://europe.hbc.honeywell.com Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom
CMT901A1044
CMT901A1028
CMT901A1010
CM901i
CMT901A1036
F42010972 001
F42010971 001
F42010977 001
Honeywell
Honeywell
Honeywell
Honeywell
Honeywell
Honeywell
N/A
N/A
English (UK).
French.
French & Dutch.
Italian.
Spanish.
Multi-lingual
Multi-lingual
Multi-lingual
Dec 05
Dec 05
Jan 06
Jan 06
Jan 06
Sep 06
Sep 06
Sep 06
EN0H 8546 UK07 R3 09/06
ENOH8546
ENOH8546
ENOH8546
ENOH8546
ENOH8546
ENOH8554
ENOH8553
N/A
Loading...