THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL
ELECTRICAL EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD STARTUP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
Vulcan-Hart Drawer Warmers and Chip
Warmers are produced with quality
workmanship and material. Proper
installation, usage, and maintenance of your
warmer will result in many years of
satisfactory performance.
INSTALLATION
Before installing, verify that the electrical
service agrees with the specifications on
the rating plate located on the lower
back corner of the warmer. If the supply
and equipment requirements do not
agree, do not proceed with unpacking
and installation. Contact your VulcanHart Customer Service Department
immediately.
UNPACKING:
The Warmer was inspected before
leaving the factory. The transportation
company assumes full responsibility for
safe delivery upon acceptance of the
shipment. Immediately after unpacking,
check for possible shipping damage to
the warmer.
If the warmer is found to be
damaged, save the packaging
material and contact the carrier
within 15 days of delivery.
Carefully unpack warmer and place in a
work accessible area.
1. Remove banding holding the
carton to the pallet.
2. Carefully remove warmer from
carton and place on floor or table.
3. Remove legs from drawer of
warmer.
4. Secure legs to the bottom of
warmer by screwing legs into the
holes provided.
It is suggested that you thoroughly read this
entire manual and carefully follow all of the
instructions provided.
The VW Series Drawer Warmers provide an
efficient means of holding a variety of
prepared hot food products at proper
temperatures until serving
.
5. Remove any and all packaging
materials in drawers.
6. Peel off vinyl protection film.
7. Thoroughly clean the warmer as
described in the cleaning instruct-
ions on page 8 of this manual.
LOCATION:
For efficient operation, choose a
location that will provide easy loading
and unloading without interfering with
the final assembly of food orders.
The installation / operation location must
be level and allow adequate clearances
for servicing and proper operation.
LEVELING INSTRUCTIONS:
In order for the self-closing drawers to
function properly, the Drawer Warmer
Unit must be leveled.
1. Place a carpenter’s level on the
top of the unit. Check leveling of
the unit front to back, and side to
side.
(Note: superior performance can be
achieved by slightly tilting the unit
backwards, so the front of the unit is
slightly higher than the back.)
Adjustable Legs: Turn leg bottom half
in counter clockwise direction to
increase height. Turn leg bottom half in
clockwise direction to decrease height.
Without Legs: The Unit must be
placed on a level surface.
Built-in Drawer Warmers come with a
“trim kit.” Follow the general installation
instructions in the “Installation &
Operation Manual” regarding
Unpacking, Electrical Requirements,
Cleaning, and Removal of Vinyl
Protection Film.
1. Remove the drawer assemblies
from the cabinet.
a. Open drawer to full extension.
b. Lift up drawer and pull out
slightly.
3. Trim Kit has 4 mounting holes.
There are two holes on the
bottom and two holes on the top.
MOUNTING HOLES
4. Using #8 Tech Screws that
are included, fasten the four
screws into the mounting holes.
The screws are self-tapping and no
pilot holes are necessary.
c. Tilt down drawer and pull out.
2. Place Trim Kit flush with the front
of the Drawer Warmer.
5. Connect Drawer Warmer to
electrical power supply per your
local electrical code.
Please refer to Electrical
Requirements in the Installation &
Operation Manual.
6. Slide warmer into designated
level location space.
7. Reinstall drawer assemblies into
warmer – Top to Bottom.
4
VW, VSL & VCW SERIES F-31086 (01-16)
ELECTRICAL REQUIREMENTS
ELECTRICAL CODES & STANDARDS:
The warmer must be installed in
accordance with:
In the United States of America:
1. State and Local Codes.
2. National Electrical Code, ANSI/
NFPA-70 (latest edition.) Copies
may be obtained from: The
National Fire Protection
Association, Batterymarch Park,
Quincy, MA 02269.
In Canada:
1. Local Codes.
2. Canadian Electrical Code, CSA
C22.1 (latest edition.) Copies
may be obtained from: The
Canadian Standard Association,
178 Rexcale Blvd., Etobicoke,
Ontario, Canada M9W 1R3.
ELECTRICAL CONNECTIONS:
The warmer is factory wired for either
110/120 volt or 208/240 volt, single
phase operation. All 110/120 volt
warmers are equipped with an 8 foot
cord and NEMA 5-15 plug as standard
equipment. All 208/240 volt warmers
are equipped with an 8 foot cord and
NEMA 6-15 plug. Refer to wiring
diagrams in the back of this manual.
The cord and plug supplied is a suitable
durable cord with a molded three-prong
plug, and is provided with a proper
strain relief.
: All warmers are
equipped with a three-prong plug. It
is imperative that this plug must be
connected into a properly grounded
three-prong receptacle. If the
receptacle is not the proper
grounding type, contact an
electrician. Do not remove the
grounding prong from this plug.
Verify that the power source
matches the Serial Data Plate located
on the lower back corner of the
warmer and the plug configuration
before the connection is made. (Fig. 1)
SERIAL DATA PLATE
Fig. 1
5
VW, VSL & VCW SERIES F-31086 (01-16)
OPERATION
CONTROLS
POWER LIGHT
The Warmer and its
parts are hot. Be very careful when
operating, cleaning, or servicing the
warmer.
The warmer Control Panel contains an
operating indicator light and a full range
thermostat. (Fig.2)
THERMOSTAT DIAL:
The thermostat also acts as the On/Off
switch to the warmer system. Turning
the thermostat counter clock-wise until it
stops will turn the warmer off.
POWER LIGHT:
The power light turns on and off as the
heating elements cycle.
THERMOSTAT DIAL (Fig. 2) THERMOMETER
It is recommended that prior to placing the warmer into operation that it be preheated at the highest temperature setting for a period of 30 to 45 minutes
.
OPERATING INSTRUCTIONS
The Warmer and its
parts are hot. Be very careful when
operating, cleaning, or servicing the
warmer.
Once the warmer has been connected
to the appropriate power source, the
warmer is ready for operation.
The warmers have one, two, three, or
four drawers depending on the model
purchased. Each drawer has a
separate thermostat dial and
thermometer.
6
Begin by turning the thermostat dial to
the number 5. This will cause the
heating element to start heating. When
this occurs, the red operating indicator
light will illuminate. This red light will
stay on as long as the heating element
is engaged. Once the predetermined
temperature is achieved, the heating
element will begin to cycle. During this
period, the red operating indicator light
will turn on and off as the heating
elements cycle.
VW, VSL & VCW SERIES F-31086 (01-16)
The thermometer will begin to move and
indicate the interior temperature of the
drawer. (Fig. 3)
The thermostat setting is from 1 to 10.
A chart of the thermostat setting and
approximate temperatures is below.
(Fig. 4)
The greater the thermostat number
setting, the higher the temperature.
The lower the thermostat number
setting, the lower the temperature.
The operator should always monitor
the food product to ensure that it
remains at proper temperatures.
(Fig. 4)
CRISP & MOIST KNOB:
Each warmer drawer is equipped with a “CRISP & MOIST” knob. For example: If you
want the food crispy side knob to the left. If you want more moisture, slide knob to the
right. (Fig. 5)
Slide knob to left for crispy (vents are
open and excess moisture can escape.)
Slide knob to right for moist (vents are
closed and moisture is held in drawer.)
(Fig. 5)
7
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.