Hobart Not Found User Manual

Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
LXeR and LXePR
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
Racks per hour Light Normal Heavy LXeR 30 24 13 LXePR 38 29 14
.62 gallons of water per rack – LXeR
1.14 gallons of water per rack – LXePR
Hot water or chemical sanitation units available
Steam Elimination and Energy Recovery (LXeR
model only)
PuriRinse cycle (Potable water rinse to remove
chemical residue) (LXePR model only)
NSF Certied pot and pan cycle on heavy cycle (LXeR model only)
Low chemical alert indicators
Sense-A-Temp™ booster heater capable of
70 rise, provided on LXeR models
Chemical pump “auto-prime”
Advanced Service diagnostics
Clogged wash arm sensing
Custom cycle selection – light, normal, heavy
Automated delime cycle – includes booster
deliming
Deep drawn stainless steel tank
Microcomputer, top mounted controls with
advanced digital cycle/temperature display
Revolving upper and lower anti-clogging wash arms
Snap in revolving upper and lower rinse arms
Removable stainless steel scrap screen
Corrosion resistant pump
Energy Saver mode
Automatic pumped drain
17" door opening
Dirty water indicator
Automatic ll
Detergent, rinse aid and delime pumps standard
(plus sanitizer pump on chemical machine)
Electric tank heat
Two dishracks – one peg and one combination
type
Customizable “advansys” button to select favorites function
Auto clean cycle washes down inside of machine at shutdown
HOT AND COLD
MODELS
LXeR – Energy Recovery LXePR – PuriRinse
STANDARD VOLTAGES
120/208-240(3W)/60/1 (LXeR model only) 120/60/1 (LXePR model only)
OPTIONS AT EXTRA COST
208-240(2W)/60/1 (LXeR model only) 208-240/60/3 (LXeR model only)
ACCESSORIES
Power cord kits Stainless steel base with 6" legs 17" stainless steel stand with storage External caster kit DWT-L Xe drain water tempering kit
Specications, Details and Dimensions on Back.
F40336 – LXeR and LXePR Hot and Cold Page 1 of 4
LXeR
HOT
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 2 of 4 F40336 – LXeR and LXePR Hot and Cold
LXePR
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
COLD
F40336 – LXeR and LXePR Hot and Cold Page 3 of 4
LXeR and LXePR
HOT AND COLD
SPECIFICATIONS
DESIGN: Front opening, equipped for installation in either free-
standing or undercounter-type operations.
CONSTRUCTION: 300 series stainless steel tank, door and top panel.
PUMP: Centrifugal-type, integral with motor, horizontally mounted. Pump capacity 38 gpm.
MOTOR: Single phase, furnished for all electrical specications. Factory sealed lubrication. Inherent overload protection with auto reset.
WASH AND RINSE CYCLE: Complete automatic type, controlled by solid-state electronics. Cycle may be interrupted any time by opening door. Cycle continues when door is closed.
• Initial cycle lls wash tank, to be recirculated each wash cycle. Some wash water is drained off before rinse cycle. Rinse cycle refreshes wash water and tank heat.
RINSE PUMP: Powered by a single phase motor, the rinse pump is made of high strength engineered composite material.
BLOWER: The blower is a 60mm x 300mm tangential wheel powered by a 2-pole single phase motor for quiet and reliable operation, LXeR only.
CONDENSER COIL: The condensing system uses a tube and n coil constructed of copper and corrosion resistant aluminum. The condenser coil allows for energy recovery from waste heat in the moisture laden air that would normally escape into the environment after a dishwashing cycle, LXeR only.
RINSE AND SANITATION:
LXeR: Sanitation is accomplished by means of a built-in booster heater designed to raise temperature of water to a minimum of 180°F from an incoming water temperature of 55°F.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
LXePR: Sanitation is accomplished by injection of proper amount of sodium hypochlorite solution (liquid bleach) into nal rinse water to achieve a minimum of 50PPM sanitizing solution. Injection of sodium hypochlorite is accomplished by a built-in sanitizing chemical pump. Minimum required hot water temperature is 120°F.
– Potable water rinse to remove chemical residue. – To be used with sanitizer approved for use with post
sanitizing rinse
CHECK SANITIZER CONCENTRATION: PuriRinse must be off (hold Wash button for 5 seconds). Verify that there is suf- cient chemical supply. Run cycle and use test trips on wetted surface of glasses after cycle is complete. If concentration is below minimum required, contact your local Hobart Service ofce.
ENERGY RECOVERY: Heat energy is recovered from the con­densation of vapors in the chamber at the end of each cycle. This pre-heats the water for the next rinse cycle from 55°F up to 140°F.
PUMPED DRAIN: Machine automatically drains water through a built-in pump. Maximum 38" drain height permitted.
ELECTRIC BOOSTER HEATER: 4.9 KW electric booster with
Sense-A-Temp™ technology adequately sized to raise 55°F inlet water to 180°F, with the aid of the energy recovery system.
RACKING: Machines accommodate racks from 10" x 20" to 20" x 20". Also accepts 16" x 18" cafeteria trays.
NOTE: Certain materials, including silver, aluminum and pewter are attacked by Sodium Hypochlorite solution in the chemical sanitizing mode of operation.
SPECIFICATIONS: Listed by Underwriters Laboratories Inc. and NSF International.
MACHINE RATINGS
Racks per Hour Rate 38 29 14 30 24 13
Dishes per Hour (25 per Rack Avg.) 950 725 350 750 600 325
Glasses per Hour (36 per Rack Avg.) 136 8 1044 504 1080 864 468
Controls Microcomputer
Tank Capacity - Gallons 2.9
Overall Dimensions - H x W x D 321⁄2 " x 2315⁄16" x 259⁄16" 321⁄2 " x 2315⁄16" x 2613⁄16"
Cycle Time - Seconds 94 124 254 120 146 275
Tan k H e at 1.8 KW
Electric Booster Heater N/A 4.9 KW
Water Usage Per Rack - Gallons 1.14 .62
Drain Design Pumped
Door Opening Height 17"
Detergent Pump Standard
Rinse-Aid Pump Standard
Delime Pump Standard
Sanitizer Pump Standard N/A
Chemical Prime (auto prime) Standard
Peak Drain Flow - GPM 4.0
Advanced Service Diagnostics Standard
Advanced Cleaning Cycle Standard
70°Rise Sense-A-Temp™ Booster Heater N/A Standard
Incoming Water Temperature Required (minimum) 120° 55°
Light Normal Heavy Light Normal Heavy
LXePR LXeR
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 4 of 4 F40336 – LXeR and LXePR Hot and Cold
F40336 (REV. 03/13) LITHO IN U.S.A. (H-01)